999 resultados para Método do fluxo de caixa descontado


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The expansion of cultivated areas with genetically modified crops (GM) is a worldwide phenomenon, stimulating regulatory authorities to implement strict procedures to monitor and verify the presence of GM varieties in agricultural crops. With the constant growing of plant cultivating areas all over the world, consumption of aflatoxin-contaminated food also increased. Aflatoxins correspond to a class of highly toxic contaminants found in agricultural products that can have harmful effects on human and animal health. Therefore, the safety and quality evaluation of agricultural products are important issues for consumers. Lateral flow tests (strip tests) is a promising method for the detection both proteins expressed in GM crops and aflatoxins-contaminated food samples. The advantages of this technique include its simplicity, rapidity and cost-effective when compared to the conventional methods. In this study, two novel and sensitive strip tests assay were developed for the identification of: (i) Cry1Ac and Cry8Ka5 proteins expressed in GM cotton crops and; (ii) aflatoxins from agricultural products. The first strip test was developed using a sandwhich format, while the second one was developed using a competitive format. Gold colloidal nanoparticles were used as detector reagent when coated with monoclonal antibodies. An anti-species specific antibody was sprayed at the nitrocellulose membrane to be used as a control line. To validate the first strip test, GM (Bollgard I® e Planta 50- EMBRAPA) and non-GM cotton leaf (Cooker 312) were used. The results showed that the strip containing antibodies for the identification of Cry1Ac and Cry8Ka5 proteins was capable of correctly distinguishing between GM samples (positive result) and non-GM samples (negative result), in a high sensitivity manner. To validate the second strip test, artificially contaminated soybean with Aspergillus flavus (aflatoxin-producing fungus) was employed. Food samples, such as milk and soybean, were also evaluated for the presence of aflatoxins. The strip test was capable to distinguish between samples with and without aflatoxins samples, at a sensitivity concentration of 0,5 μg/Kg. Therefore, these results suggest that the strip tests developed in this study can be a potential tool as a rapid and cost-effective method for detection of insect resistant GM crops expressing Cry1Ac and Cry8Ka5 and aflatoxins from food samples.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The expansion of cultivated areas with genetically modified crops (GM) is a worldwide phenomenon, stimulating regulatory authorities to implement strict procedures to monitor and verify the presence of GM varieties in agricultural crops. With the constant growing of plant cultivating areas all over the world, consumption of aflatoxin-contaminated food also increased. Aflatoxins correspond to a class of highly toxic contaminants found in agricultural products that can have harmful effects on human and animal health. Therefore, the safety and quality evaluation of agricultural products are important issues for consumers. Lateral flow tests (strip tests) is a promising method for the detection both proteins expressed in GM crops and aflatoxins-contaminated food samples. The advantages of this technique include its simplicity, rapidity and cost-effective when compared to the conventional methods. In this study, two novel and sensitive strip tests assay were developed for the identification of: (i) Cry1Ac and Cry8Ka5 proteins expressed in GM cotton crops and; (ii) aflatoxins from agricultural products. The first strip test was developed using a sandwhich format, while the second one was developed using a competitive format. Gold colloidal nanoparticles were used as detector reagent when coated with monoclonal antibodies. An anti-species specific antibody was sprayed at the nitrocellulose membrane to be used as a control line. To validate the first strip test, GM (Bollgard I® e Planta 50- EMBRAPA) and non-GM cotton leaf (Cooker 312) were used. The results showed that the strip containing antibodies for the identification of Cry1Ac and Cry8Ka5 proteins was capable of correctly distinguishing between GM samples (positive result) and non-GM samples (negative result), in a high sensitivity manner. To validate the second strip test, artificially contaminated soybean with Aspergillus flavus (aflatoxin-producing fungus) was employed. Food samples, such as milk and soybean, were also evaluated for the presence of aflatoxins. The strip test was capable to distinguish between samples with and without aflatoxins samples, at a sensitivity concentration of 0,5 μg/Kg. Therefore, these results suggest that the strip tests developed in this study can be a potential tool as a rapid and cost-effective method for detection of insect resistant GM crops expressing Cry1Ac and Cry8Ka5 and aflatoxins from food samples.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conasfaltos S.A es una empresa posicionada en el mercado en la venta de materiales pétreos y construcción de obras de infraestructura e ingeniería a nivel regional, con grandes expectativas de crecimiento y fortalecimiento en el sector de obras a nivel nacional. Basados en la propuesta de crecimiento y expansión, se considera prudente realizar una valoración de la unidad de negocio de obras, de manera que permita identificar oportunidades de mejora, e implementar estrategias que aporten al mejoramiento del VPN de la empresa, como se observa en el desarrollo de la trabajo. La metodología utilizada para el desarrollo del trabajo, consta del análisis realizado a partir del año 2006 de la industria de la construcción, principales indicadores económicos y del sector, además de los estados financieros de la empresa y sus principales competidores a nivel nacional y regional, de manera que se identifiquen comportamientos que permitan realizar las proyecciones necesarias para la valoración de la compañía a través del método de Flujo de caja libre descontado. En la valoración se encontró que la compañía debe tener especial cuidado con el capital de trabajo neto operativo, debido a su relación directa con las ventas, además es importante evaluar y controlar las inversiones, de acuerdo a la capacidad de la compañía, pues se identifica que los altos niveles de inversión proyectados en los periodos 2013 y 2015 son superiores a los flujos de caja bruto, generando destrucción de valor y en efecto un menor VPN.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

No Brasil o biodiesel é utilizado em misturas com óleo diesel em proporções de 5%, sem que haja modificações nos motores. Com o intuito de diversificar a utilização de oleaginosas não comestíveis no ramo dos biocombustíveis, e ainda vincular a produção com agricultura sustentável, uma alternativa para o RS é a utilização do óleo de tungue para a produção de biodiesel. A caracterização e quantificação de ácidos graxos do biodiesel de tungue, torna-se importante devido à seu exclusivo perfil graxo. Neste trabalho, foi estudado o desenvolvimento e validação de método para a determinação do perfil graxo do biodiesel metílico de tungue e blendas com soja utilizando GC-MS. Os parâmetros de validação considerados foram: curva analítica, linearidade, seletividade, limite de detecção e quantificação, robustez, precisão e exatidão. Para determinar as melhores condições cromatográficas, foram testadas diferentes programações de temperatura no forno cromatográfico; fluxo de gás; temperatura do injetor, detector e interface; e modo de injeção. As condições do GCMS após a otimização foram: injeção de 1 µL com injeção em alta pressão (300 kPa), T do injetor: 250 ºC, injeção split 1:30, fluxo de 1 mL min-1, coluna Rtx-5MS com dimensões 30 m x 0,25 mm x 0,25 µm, T forno: isoterma de 2 min a 130 ºC, aumento de 20 ºC/min até 220 ºC, aumento de 0,5ºC/min até 223ºC, aumento de 7 ºC/min até 250 ºC e isoterma em 250 ºC por 3 min, resultando em 20 min de análise. A temperatura da fonte e interface foram de 200 ºC e 250 ºC, respectivamente, com o MS no modo full scan, ionização por impacto eletrônico a 70 eV, e intervalo de massas de 30 a 500 u.m.a. A identificação do α-eleosteárico foi baseada na fragmentação característica do composto, pela comparação com o espectro do ácido linolênico, e ainda pelo tempo de retenção do composto. Na validação, as curvas analíticas apresentaram valores de r maiores que 0,99. O LD e LQ foram adequados, permitindo a quantificação de ésteres na concentração mínima de 0,6%. Os valores de exatidão ficaram entre 86 e 117%, com RSD% menores que 8%. O efeito matriz também foi avaliado, sendo que esse efeito foi considerado médio para a maioria dos compostos, ficando entre ± 20 e 50%. Durante a aplicação do método, o mesmo se mostrou adequado para amostras de biodiesel metílico de tungue e blendas com soja, nas proporções de 15:85, 20:80 e 25:75 (T:S, v/v). A aplicabilidade do método também foi testada para o biodiesel de soja, obtendo resultados satisfatórios, mostrando-se assim, além de tudo, ser um método robusto.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

O desenvolvimento de métodos adequados que permitam o monitoramento de resíduos e contaminantes em alimentos é de suma importância pois é a única forma de garantir a segurança dos alimentos evitando danos à saúde do consumidor. Para isso, fazse necessário que estes métodos sejam rápidos, fáceis e de baixo custo, capazes de detectar a presença de resíduos em concentrações baixas e em diferentes matrizes. Este trabalho consistiu no desenvolvimento de método para determinação de 5 sedativos e 14 β-bloqueadores em amostras de rim suíno e posterior análise por Cromatografia Líquida Acoplada à Espectrometria de Massas em Série (LC-MS/MS). O procedimento de extração que melhor se adequou para análise destes compostos consistiu na pesagem de 2 g de amostra e adição de 10 mL de acetonitrila seguida de homogeneização com auxílio de Ultra-Turrax e mesa agitadora. Após extração, as amostras foram submetidas a duas técnicas de clean-up, sendo elas, congelamento do extrato à baixa temperatura e extração em fase sólida dispersiva (d-SPE) utilizando como sorvente Celite® 545. Uma etapa de concentração foi realizada com auxílio de concentrador de amostras sob fluxo de N2 e temperatura controlada. As amostras secas foram retomadas com metanol e analisadas utilizando sistema LC-MS/MS com Ionização por Eletrospray (ESI), operando no modo MRM positivo, coluna Poroshell 120 EC-C18 (3,0 x 50 mm, 2,7 μm) para separação dos analitos, e gradiente de fase móvel composta por (A) solução aquosa acidificada com 0,1% de ácido fórmico (v/v) e (B) metanol 0,1% ácido fórmico (v/v). Os parâmetros de validação avaliados foram linearidade, seletividade, efeito matriz, precisão, veracidade, recuperação, limite de decisão, capacidade de detecção, incerteza da medição, robustez, limite de detecção e de quantificação. Além disso foram observados os critérios de desempenho aplicáveis à detecção por espectrometria de massas e estabilidade dos compostos. A recuperação foi avaliada em 10 μg kg-1 e a veracidade em 5, 10 e 15 μg kg-1 apresentando resultados satisfatórios entre 70 - 85% e 90 - 101%, respectivamente. O limite de quantificação determinado foi de 2,5 μg kg-1 , exceto para carazolol que foi de 1,25 μg kg- 1 . O estudo de linearidade foi realizado entre 0 e 20 μg kg-1 apresentando coeficientes de determinação superiores a 0,98. Estes procedimentos foram realizados através de análise de matriz branca fortificada. Além disso, o presente método foi utilizado para analisar carazolol, azaperone e azaperol em amostras de ensaio colaborativo de rim suíno, apresentando resultados muito próximos aos reais. Portanto, é possível concluir que o método desenvolvido é adequado para análise de sedativos e β-bloqueadores através de extração dos compostos e limpeza do extrato eficientes utilizando procedimentos rápidos, fáceis e de baixo custo, garantindo resultados seguros e confiáveis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Continuous Synthesis by Solution Combustion was employed in this work aiming to obtain tin dioxide nanostructured. Basically, a precursor solution is prepared and then be atomized and sprayed into the flame, where its combustion occurs, leading to the formation of particles. This is a recent technique that shows an enormous potential in oxides deposition, mainly by the low cost of equipment and precursors employed. The tin dioxide (SnO2) nanostructured has been widely used in various applications, especially as gas sensors and varistors. In the case of sensors based on semiconducting ceramics, where surface reactions are responsible for the detection of gases, the importance of surface area and particle size is even greater. The preference for a nanostructured material is based on its significant increase in surface area compared to conventional microcrystalline powders and small particle size, which may benefit certain properties such as high electrical conductivity, high thermal stability, mechanical and chemical. In this work, were employed as precursor solution tin chloride dehydrate diluted in anhydrous ethyl alcohol. Were utilized molar ratio chloride/solvent of 0,75 with the purpose of investigate its influence in the microstructure of produced powder. The solution precursor flux was 3 mL/min. Analysis with X-ray diffraction appointed that a solution precursor with molar ratio chloride/solvent of 0,75 leads to crystalline powder with single phase and all peaks are attributed to phase SnO2. Parameters as distance from the flame with atomizer distance from the capture system with the pilot, molar ratio and solution flux doesn t affect the presence of tin dioxide in the produced powder. In the characterization of the obtained powder techniques were used as thermogravimetric (TGA) and thermodiferential analysis (DTA), particle size by laser diffraction (GDL), crystallographic analysis by X-ray diffraction (XRD), morphology by scanning electron microscopy (SEM), transmission electron microscopy (TEM), specific surface area (BET) and electrical conductivity analysis. The techniques used revealed that the SnO2 exhibits behavior of a semiconductor material, and a potentially promising material for application as varistor and sensor systems for gas

Relevância:

30.00% 30.00%

Publicador:

Resumo:

O presente Trabalho de Investigação Aplicada encontra-se subordinado ao tema “Fluxo de Informação Financeira entre o Território Nacional e os Teatros de Operações: Abordagem Sociocrítica em contexto de mudança.”. Tendo em conta o contexto económico que o país atravessa, e que indiretamente afeta as organizações do Estado, através das consequentes reduções orçamentais, torna-se imprescindível que exista um aproveitamento dos recursos muito mais eficiente e eficaz. Neste contexto e face à existência em Território Nacional do Sistema Integrado de Gestão nas Instituições do Ministério de Defesa Nacional, nomeadamente no Exército, revelou-se indispensável a implementação desta ferramenta de gestão nas Forças Nacionais Destacadas dos Teatros de Operações. Desta forma, o objetivo geral desta investigação é identificar as limitações e potencialidades que a recente implementação do Sistema Integrado de Gestão nos Teatros de Operações provocou no desempenho das funções dos Oficiais de Finanças. Neste trabalho procuramos ainda identificar o impacto da harmonização dos procedimentos contabilísticos na execução orçamental, as melhorias do processo de tomada de decisão, a harmonização na realização do relato financeiro, e consequentes alterações nos procedimentos de mudança de contingente, bem como as alterações na execução das diferentes fases do Registo Contabilístico do Fundo de Maneio. Para a elaboração desta investigação aplicou-se o método hipotético-dedutivo, sendo desenvolvida segundo objetivos descritivos e exploratórios com o intuito de identificar, explorar e descrever as limitações e potencialidades da implementação do Sistema Integrado de Gestão na Força Nacional Destacada do Kosovo, recorrendo ao estudo exploratório/descritivo, enquadrando-se ainda na categoria do Estudo de Caso. No sentido de atingir os objetivos propostos inicialmente foram elaborados e aplicados diferentes inquéritos por entrevista. Após a análise e discussão dos resultados foi possível concluir que a informação contabilística disponível em tempo real, de forma imediata e oportuna, permite aos Oficiais de Finanças serem mais eficazes e assertivos no aconselhamento ao Comandante, assim como origina uma melhor e mais célere tomada de decisão em Teatro de Operações e para toda cadeia de comando em Território Nacional. Outra grande mais-valia foi a possibilidade de reduzir significativamente o Fundo de Maneio. Alcançado o final desta investigação, foi possível concluir que não existem limitações do Sistema Integrado de Gestão nos Teatros de Operações que não existam em Território Nacional, sendo dessa forma possível constatar que as possíveis melhorias são a implementação da contabilidade analítica e a integração de todas as áreas desta ferramenta, permitindo tirar total partido da mesma.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Water injection is the most widely used method for supplementary recovery in many oil fields due to various reasons, like the fact that water is an effective displacing agent of low viscosity oils, the water injection projects are relatively simple to establish and the water availability at a relatively low cost. For design of water injection projects is necessary to do reservoir studies in order to define the various parameters needed to increase the effectiveness of the method. For this kind of study can be used several mathematical models classified into two general categories: analytical or numerical. The present work aims to do a comparative analysis between the results presented by flow lines simulator and conventional finite differences simulator; both types of simulators are based on numerical methods designed to model light oil reservoirs subjected to water injection. Therefore, it was defined two reservoir models: the first one was a heterogeneous model whose petrophysical properties vary along the reservoir and the other one was created using average petrophysical properties obtained from the first model. Comparisons were done considering that the results of these two models were always in the same operational conditions. Then some rock and fluid parameters have been changed in both models and again the results were compared. From the factorial design, that was done to study the sensitivity analysis of reservoir parameters, a few cases were chosen to study the role of water injection rate and the vertical position of wells perforations in production forecast. It was observed that the results from the two simulators are quite similar in most of the cases; differences were found only in those cases where there was an increase in gas solubility ratio of the model. Thus, it was concluded that in flow simulation of reservoirs analogous of those now studied, mainly when the gas solubility ratio is low, the conventional finite differences simulator may be replaced by flow lines simulator the production forecast is compatible but the computational processing time is lower.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A agricultura é a atividade humana que mais afeta o meio ambiente. Imensas quantidades de insumos agrícolas são aplicados sobre o solo e grande parte destes degrada os recursos hídricos. Para uma investigação adequada do efeito destes insumos, estudam-se as propriedades hidráulicas do solo, que influem no transporte de solutos neste meio. Medir tais propriedades e modelar os parâmetros correlatos são tarefas extremamente complexas, devido ao tempo requerido, dinheiro, instrumentação e escala. As metodologias convencionais inferem as propriedades hidráulicas em amostras que estão em equilíbrio, através de técnicas invasivas e sob restrições especiais. esta tes contribui com a Ciência do Ambiente, via Ciência do Solo, propondo um novo método de estudo da infiltração da água na região não-saturada do solo, utilizando a tomografia computadorizada (TC). O tomógrafo foi aqui desenvolvido e construído. A TC, neste trabalho, mediu a umidade durante o fluxo não-saturado e, através da solução numérica da equação de Richards e do modelo Rossi-Nimmo, obtiveram-se a curva de retenção, a sortividade, e a difusividade. Resultados qualitativos, como imagens 2D e 3D, e resultados quantitativos demonstraram a boa correlação do método proposto com o método tradicional de medida da curva de retenção. Amostras de solo estruturado foram analisadas em laboratório e em camp.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

O presente trabalho teve o objetivo de analisar a repercussão sobre o tratamento de esgoto e o uso do método anaeróbico. Neste, mostraremos a relação entre a eficiência da remoção do fósforo e a implantação do sistema de flotação pós-reator anaeróbio. A Estação de Tratamento de Esgoto Ipanema está instalada as margens do Córrego Terra Branca, afluente do Rio Araguari, no município de Uberlândia, Minas Gerais, tendo o Departamento de Água e Esgoto de Uberlândia como responsável pela operação desta unidade. Esta estação de tratamento de esgoto atende uma população aproximadamente de 7000 habitantes residentes nos bairros Aclimação e Ipanema e, inicialmente era composta por grades grossas, uma caixa de areia, um reator anaeróbio de fluxo ascendente (RAFA), um filtro biológico e um tanque de decantação. Para a melhoria da eficiência da estação, foi implementado um tratamento complementar pós-reator de forma que este faça a adequação necessária para promoção da qualidade ambiental do efluente pós-tratamento no que se refere ao parâmetro fósforo para o lançamento no copo receptor, enquadrado na Classe 2, da Resolução do CONAMA 357/2005. O canal de tratamento por flotação em fluxo variável para receber o efluente pós-reator substituiu o polimento realizado atualmente através de filtro biológico e o tanque de decantação.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Two hundred and six patients with severe head injury (Glasgow Coma Scale of 8 points or less after nonsurgical resuscitation on admission), managed at Intensive Care Unit-Hospital das Clínicas - Universidade Estadual de Campinas were prospectively analysed. All patients were assessed by CT scan and 72 required neurosurgical intervention. All patients were continuously monitored to evaluate intracranial pressure (ICP) levels by a subarachnoid device (11 with subarachnoid metallic bolts and 195 with subarachnoid polyvinyl catheters). The ICP levels were continuously observed in the bedside pressure monitor display and their end-hour values were recorded in a standard chart. The patients were managed according to a standard protocol guided by the ICP levels. There were no intracranial haemorrhagic complications or hematomas due the monitoring method. Sixty six patients were punctured by lateral C1-C2 technique to assess infectious complications and 2 had positive cerebrospinal fluid samples for Acinetobacter sp. The final results measured at hospital discharge showed 75 deaths (36,40%) and 131 (63,60%) survivors. ICP levels had significantly influenced the final results (p<0,001). The subarachnoid method to continuously assess the ICP levels was considered aplicable, safe, simple, low cost and useful to advise the management of the patients. The ICP record methodology was practical and useful. Despite the current technical advances the subarachnoid method was considered viable to assess the ICP levels in severe head injury.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study is to introduce a method to evaluate visual functions in infants in the first three months of life. An adaptation of the Guide for the Assessment of Visual Ability in Infants (Gagliardo, 1997) was used. The instrument was a ring with string. It was implemented a pilot study with 33 infants, selected according to the following criteria: neonates well enough to go home within two days of birth; 1 to 3 months of chronological age; monthly evaluation with no absence; subjects living in Campinas/SP metropolitan area. In the first month we observed: visual fixation (93,9%); eye contact (90,9%); horizontal tracking (72,7%); inspects surroundings (97,0%). In the third month, we observed: inspects own hands (42,4%) and increased movements of arms (36,4%). This method allowed the evaluation of visual functions in infants, according to the chronological age. Alterations in this function will facilitate immediate referral to medical services for diagnoses.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Gaseous mercury sampling conditions were optimized and a dynamic flux chamber was used to measure the air/surface exchange of mercury in some areas of the Negro river basin with different vegetal coverings. At the two forest sites (flooding and non-flooding), low mercury fluxes were observed: maximum of 3 pmol m-2 h-1 - day and minimum of -1 pmol m-2 h-1 - night. At the deforested site, the mercury fluxes were higher and always positive: maximum of 26 pmol m-2 h-1 - day and 17 pmol m-2 h-1 - night. Our results showed that deforestation could be responsible for significantly increasing soil Hg emissions, mainly because of the high soil temperatures reached at deforested sites.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The ONIOM method was used to calculate the proton affinities (PA) of n-alkylamines (CnH2n+1NH2, n = 3 to 6, 8, 10, 12, 14, 16 and 18). The calculations were carried out at several levels (HF, MP2, B3LYP, QCISD(T), ...) using Pople basis sets and at the QCISD(T) level using basis sets developed by the generator coordinate method (GCM) and adapted to effective core potentials. PAs were also obtained through the GCM and high level methods, like ONIOM[QCISD(T)/6-31+G(2df,p):MP2/6-31G+G(d,p))//ONIOM[MP2/6-31+G(d,p):HF/6-31G]. The average error using the GCM, with respect to experimental data, was 3.4 kJ mol-1.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work a simple and sensitive procedure to extract organic mercury from water and sediment samples, using methylene chloride in acidic media followed by CVAFS quantification has been developed. The method was evaluated for possible interferents, using different inorganic mercury species and humic acid, no effects being observed. The detection limit for organic mercury was 160 pg and 396 pg for water and sediment samples respectively. The accuracy of the method was evaluated using a certified reference material of methylmercury (BCR-580, estuarine sediment). Recovery tests using methylmercury as surrogate spiked with 1.0 up to 30.0 ng L-1 ranged from 90 up to 109% for water samples, whereas for sediments, recoveries ranged from 57 up to 97%.