957 resultados para Laterally Loaded Pile


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A combined experimental and analytical study of a hat-stiffened carbon-fibre composite panel loaded in uniaxial compression was investigated. A buckling mode transition was observed in the panel's skin bay which was not captured using non-linear finite-element analysis. Good correlation between experimental and numerical strain and displacement results was achieved in the prebuckling and initial postbuckling region of the loading history. A Marguerre-type Rayleigh-Ritz energy method was applied to the skin bay using representative displacement functions of permissible mode shapes to explain the mode transition phenomenon. The central criterion of this method was based on the assumption that a change in mode shape occurred such that the total potential energy of the structure was maintained at a minimum. The ultimate strength of the panel was limited by the column buckling strength of the hat-stiffeners.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A plethora of studies have described the in vitro assessment of dissolving microneedle (MN) arrays for enhanced transdermal drug delivery, utilising a wide variety of model membranes as a representation of the skin barrier. However, to date, no discussion has taken place with regard to the choice of model skin membrane and the impact this may have on the evaluation of MN performance. In this study, we have, for the first time, critically assessed the most common types of in vitro skin permeation models - a synthetic hydrophobic membrane (Silescol(®) of 75 µm) and neonatal porcine skin of definable thickness (300-350 µm and 700-750 µm) - for evaluating the performance of drug loaded dissolving poly (methyl vinyl ether co maleic acid) (PMVE/MA) MN arrays. It was found that the choice of in vitro skin model had a significant effect on the permeation of a wide range of small hydrophilic molecules released from dissolving MNs. For example, when Silescol(®) was used as the model membrane, the cumulative percentage permeation of methylene blue 24h after the application of dissolvable MNs was found to be only approximately 3.7% of the total methylene blue loaded into the MN device. In comparison, when dermatomed and full thickness neonatal porcine skin were used as a skin model, approximately 67.4% and 47.5% of methylene blue loaded into the MN device was delivered across the skin 24h after the application of MN arrays, respectively. The application of methylene blue loaded MN arrays in a rat model in vivo revealed that the extent of MN-mediated percutaneous delivery achieved was most similar to that predicted from the in vitro investigations employing dermatomed neonatal porcine skin (300-350 µm) as the model skin membrane. On the basis of these results, a wider discussion within the MN community will be necessary to standardise the experimental protocols used for the evaluation and comparison of MN devices.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nitric oxide (NO) is important for the regulation of a number of diverse biological processes, including vascular tone, neurotransmission, inflammatory cell responsiveness, defence against invading pathogens and wound healing. Transition metal exchanged zeolites are nanoporous materials with high-capacity storage properties for gases such as NO. The NO stores are liberated upon contact with aqueous environments, thereby making them ideal candidates for use in biological and clinical settings. Here, we demonstrate the NO release capacity and powerful bactericidal properties of a novel NO-storing Zn2+-exchanged zeolite material at a 50 wt.% composition in a polytetrafluoroethylene polymer. Further to our published data showing the anti-thrombotic effects of a similar NO-loaded zeolite, this study demonstrates the antibacterial properties of NO-releasing zeolites against clinically relevant strains of bacteria, namely Gram-negative Pseudomonas aeruginosa and Gram-positive methicillin-sensitive and methicillin-resistant Staphylococcus aureus and Clostridium difficile. Thus our study highlights the potential of NO-loaded zeolites as biocompatible medical device coatings with anti-infective properties. (C) 2009 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The behaviour and ultimate load capacity of laterally-restrained reinforced concrete slabs can be considerably enhanced by the development of arching or compressive membrane action. This paper presents a simple method for predicting the enhanced ultimate load capacity of laterally-restrained slab strips. The method is based on deformation theory and utilizes an elastic-plastic stress-strain criterion for concrete. The loads carried by bending and arching action are calculated separately and then added to give the total ultimate load capacity. A simple equivalent strip approach, based on a three-hinged arch analogy, allows for the degree of lateral restraint. The method of prediction has been validated by correlation with a wide range of test results from various sources.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Scour around bridge foundations is one of the leading causes of bridge failure. Up until recently, the monitoring of this phenomenon was primarily based around using underwater instrumentation to monitor the progression of scour holes as they develop around foundation systems. Vibration-based damage detection techniques have been used to detect damage in bridge beams. The application of these vibration based methods to the detection of scour has come to the fore in research in recent years. This paper examines the effect that scour has on the frequency response of a driven pile foundation system, similar to those used to support road and rail bridges. The effect of scour on the vibration characteristics of the pile is examined using laboratory and field testing. It is clear that there is a very clear reduction in the natural frequency of the pile as the severity of scour increases. It is shown that by combining state-of-the-art geotechnical techniques with relatively simple finite element modelling approaches, it is possible to accurately predict the natural frequency of the pile for a given scour depth. Therefore, the paper proposes a method that would allow the estimation of scour depth for a given observed pile frequency.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

It is demonstrated that the electromagnetic (EM) transmission through a subwavelength or non-resonant aperture in a conductive screen can be dramatically enhanced by loading it with folded metallic strips exhibiting resonant properties. When illuminated by an EM plane wave these loaded apertures enable very tight, subwavelength, collimation of the EM power in the near field zone. We propose planar and quasi-planar resonant insertion geometries that should allow, for the first time, two-dimensional dual-polarization subwavelength field confinement along with ability to focus both electric and magnetic fields. The proposed technique for resonance transmission enhancement and near field confinement forms a basis for a new class of microwave near field imaging probe with subwavelength resolution capable of operating over a wide range of imaging distances (0.05–$0.25lambda$). Measurement results demonstrate the possibility of high contrast (more than 3 dB in amplitude and 40 degrees in phase) near field subwavelength imaging of 2D and 3D resonant and non-resonant metallic and dielectric targets in free space and in moderately lossy layered media.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes an experimental investigation on the pressure dip phenomenon in a conical pile of granular solids. The roles of different deposition processes such as the pouring rate, pouring height and deposition jet size on the pressure dip formation were studied. Test results confirmed that the pressure dip is a robust phenomenon in a pile formed by top deposition. When the deposition jet radius is significantly smaller than the final pile radius (i.e. concentrated deposition), a dip developed in the centre as shown in previous studies. However, when the deposition jet radius is comparable to the final pile radius (i.e. diffuse deposition), the location of the dip moves towards the edge of deposition jet, with a local maximum pressure developed in the centre. For concentrated deposition, an increase in the pouring rate may enhance the depth of the dip and reduce its width, while an increase in the pouring height has only a negligible effect in the studied range. The results suggest the pressure dip is closely related to the initial location, intensity and form of downslope flows. © 2013 Elsevier Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cervical cancer is the third most prevalent cancer in women and disproportionately affects those in low resource settings due to limited programs for screening and prevention. In the developed world treatment for the disease in the non-metastasised state usually takes the form of surgical intervention and/or radiotherapy. In the developing world such techniques are less widely available. This paper describes the development of an intravaginal ring for the localised delivery of a chemotherapeutic drug to the cervix that has the potential to reduce the need for surgical intervention and will also provide a novel anti-cancer therapy for women in low resource settings. Disulfiram has demonstrated antineoplastic action against prostate, breast and lung cancer. Both PEVA and silicone elastomer were investigated for suitability as materials in the manufacture of DSF eluting intravaginal rings. DSF inhibited the curing process of the silicone elastomer, therefore PEVA was chosen as the material to manufacture the DSF-loaded vaginal rings. The vaginal rings had an excellent content uniformity while the DSF remained stable throughout the manufacturing process. Furthermore, the rings provided diffusion controlled release of DSF at levels well in excess of the IC50 value for the HeLa cervical cancer cell line.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study presents the design of a thin electromagnetic absorber which exhibits radar backscatter suppression that is independent of the wave polarisation at large incidence angles. The structure consists of a metal backed printed frequency selective surface (FSS), with resistors placed across narrow gaps inserted in the middle of each of the four sides of the conductor loops. The geometry of the periodic array and the value of the vertical and horizontal resistor pairs are carefully chosen to present a real impedance of 377 Ω at the centre operating frequency for both TE and TM polarised waves. Angular sensitivity and reflectivity bandwidth have been investigated for FSS absorber designs with thicknesses of 1, 2 and 3 mm. Each of the three structures was optimised to work at a centre frequency of 10 GHz and an incident angle of 45°. The design methodology is verified by measuring the radar backscatter suppression from a 3 mm (l / 10) thick screen in the frequency range 8–12 GHz. The absorber construction was simplified by filling the four metal gaps in each unit cell with shielding paint, and selecting the ink thickness to give the two required surface resistance values.