998 resultados para LOCALIZED VOLUME DEFICIENCIES
Resumo:
Ultrasound scans in the mid-trimester of pregnancy are now a routine part of antenatal care in most European countries. Using data from registries of congenital anomalies a study was undertaken in Europe. The objective of the study was to evaluate prenatal detection of limb reduction deficiencies (LRD) by routine ultrasonographic examination of the fetus. All LRDs suspected prenatally and all LRDs (including chromosome anomalies) confirmed at birth were identified from 20 Congenital Malformation Registers from the following 12 European countries: Austria, Croatia, Denmark, France, Germany, Italy, Lithuania, Spain, Switzerland, The Netherlands, UK and Ukrainia. These registries are following the same methodology. During the study period (1996-98) there were 709,030 births, and 7,758 cases with congenital malformations including LRDs. If more than one LRD was present the case was coded as complex LRD; 250 cases of LRDs with 63 (25.2%) termination of pregnancies were identified including 138 cases with isolated LRD, 112 with associated malformations, 16 with chromosomal anomalies and 38 non chromosomal recognized syndromes. The prenatal detection rate of isolated LRD was 24.6% (34 out of 138 cases) compared with 49.1% for associated malformations (55 out of 112; p<0.01). The prenatal detection of isolated terminal transverse LRD was 22.7% (22 out of 97), 50% (3 out of 6) for proximal intercalary LRD, 8.3% (1 out of 12) for longitudinal LRD and 0 for split hand/foot; for multipli-malformed children with LRD those percentages were 46.1% (30 out of 65), 66.6% (6 out of 9), 57.1% (8 out of 14) and 0 (0 out of 2), respectively. The prenatal detection rate of LRDs varied in relation with the ultrasound screening policies from 20.0% to 64.0% in countries with at least one routine fetal scan.
Resumo:
Objectifs : Evaluer une méthode simple et rapide de mesure du volume atrial gauche. Matériels et méthodes : Cinquante patients ont été examinés avec un CT gaté pour mesure du score calcique. Trois méthodes ont été utilisées pour calculer le volume atrial gauche : 1) une méthode orthogonale avec mesure des surfaces/diamètres dans les plans axiaux/coronaux/sagittaux, 2) une méthode biplan inspirée de l'échocardiographie et 3) une méthode volumétrique. Les mesures ont été faites par le même observateur un mois plus tard et ont été répétées par trois autres observateurs. L'axe cardiaque a aussi été mesuré. La méthode Bland-Altmann et les corrélations de Spearman ont été utilisées. Résultats : La méthode volumétrique montre les variations intra/interobservateur les plus basses avec une variabilité de 6,1/7,4 ml, respectivement. Pour les mesures avec la méthode orthogonale (surfaces/diamètres), les variations intra/interobservateur sont 12,3/13,5 ml et 14,6/11,6 ml, respectivement. Pour la méthode biplan, les variations intra/interobservateur sont plus hautes : 23,9/19,8 ml. Comparée à la méthode de référence volumétrique, la méthode orthogonale avec les surfaces est mieux corrélée (R=0,959, p<0,001) que les autres méthodes. Il y a une faible influence de l'axe du coeur sur la méthode orthogonale avec les surfaces. Conclusion : La méthode volumétrique est le gold standard en terme de variabilité. Cependant elle est longue à metttre en oeuvre. La méthode orthogonale avec les surfaces est une alternative simple, sauf chez les patients obèses avec un coeur horizontalisé.
Resumo:
INTRODUCTION. Patient-ventilator asynchrony is a frequent issue in non invasivemechanical ventilation (NIV) and leaks at the patient-mask interface play a major role in itspathogenesis. NIV algorithms alleviate the deleterious impact of leaks and improve patient-ventilator interaction. Neurally adusted ventilatory assist (NAVA), a neurally triggered modethat avoids interferences between leaks and the usual pneumatic trigger, could further improvepatient-ventilator interaction in NIV patients.OBJECTIVES. To evaluate the feasibility ofNAVAin patients receiving a prophylactic postextubationNIV and to compare the respective impact ofPSVandNAVAwith and withoutNIValgorithm on patient-ventilator interaction.METHODS. Prospective study conducted in 16 beds adult critical care unit (ICU) in a tertiaryuniversity hospital. Over a 2 months period, were included 17 adult medical ICU patientsextubated for less than 2 h and in whom a prophylactic post-extubation NIV was indicated.Patients were randomly mechanically ventilated for 10 min with: PSV without NIV algorithm(PSV-NIV-), PSV with NIV algorithm (PSV-NIV+),NAVAwithout NIV algorithm (NAVANIV-)and NAVA with NIV algorithm (NAVA-NIV+). Breathing pattern descriptors, diaphragmelectrical activity, leaks volume, inspiratory trigger delay (Tdinsp), inspiratory time inexcess (Tiexcess) and the five main asynchronies were quantified. Asynchrony index (AI) andasynchrony index influenced by leaks (AIleaks) were computed.RESULTS. Peak inspiratory pressure and diaphragm electrical activity were similar in thefour conditions. With both PSV and NAVA, NIV algorithm significantly reduced the level ofleak (p\0.01). Tdinsp was not affected by NIV algorithm but was shorter in NAVA than inPSV (p\0.01). Tiexcess was shorter in NAVA and PSV-NIV+ than in PSV-NIV- (p\0.05).The prevalence of double triggering was significantly lower in PSV-NIV+ than in NAVANIV+.As compared to PSV,NAVAsignificantly reduced the prevalence of premature cyclingand late cycling while NIV algorithm did not influenced premature cycling. AI was not affectedby NIV algorithm but was significantly lower in NAVA than in PSV (p\0.05). AIleaks wasquasi null with NAVA and significantly lower than in PSV (p\0.05).CONCLUSIONS. NAVA is feasible in patients receiving a post-extubation prophylacticNIV. NAVA and NIV improve patient-ventilator synchrony in different manners. NAVANIV+offers the best patient-ventilator interaction. Clinical studies are required to assess thepotential clinical benefit of NAVA in patients receiving NIV.
Resumo:
While chronic hypoglycaemia has been reported to increase unidirectional glucose transport across the blood-brain barrier (BBB) and to increase GLUT1 expression at the endothelium, the effect on steady-state brain d-glucose and brain glycogen content is currently unknown. Brain glucose and glycogen concentrations were directly measured in vivo using localized 13C magnetic resonance spectroscopy (MRS) following 12-14 days of hypoglycaemia. Brain glucose content was significantly increased by 48%, which is consistent with an increase in the maximal glucose transport rate, Tmax, by 58% compared with the sham-treated animals. The localized 13C NMR measurements of brain glucose were directly validated by comparison with biochemically determined brain glucose content after rapid focused microwave fixation (1.4 s at 4 kW). Both in vivo MRS and biochemical measurements implied that brain glycogen content was not affected by chronic hypoglycaemia, consistent with brain glucose being a major factor controlling brain glycogen content. We conclude that the increased glucose transporter expression in chronic hypoglycaemia leads to increased brain glucose content at a given level of glycaemia. Such increased brain glucose concentrations can result in a lowered glycaemic threshold of counter-regulation observed in chronic hypoglycaemia.