959 resultados para Industrial power trucks


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Journalists in the “new media” era confront important questions as to whether, or how, they adapt their professional practices to a new interactive on-line form that allows citizens to become involved in the news-making process. This paper seeks to re-establish the relevance of traditional journalism practices in the modern era and suggests that they will remain very much a part of the “new journalism” beyond the digital divide. It does so through examining how broadcast journalism interviews challenge authorities in the “public interest”, and suggests, in conclusion, that such practices remain undiminished by the technical, and accompanying social, changes that are driving the “new media”.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Queensland’s legal labour disputes history does not exhibit the current trend seen in Canada and Switzerland (Gravel & Delpech, 2008) where cases citing International Labour Standards (ILS) are often successful (which is not presently the case in Queensland either). The two Queensland cases (Kuhler v. Inghams Enterprises P/L & Anor, 1997 and Bale v. Seltsam Pty Ltd, 1996) that have used ILSs were lost. Australia is a member state of the International Labour Organization (ILO) and a signatory of many ILSs. Yet, ILSs are not used in their legal capacity when compared to other international standards in other areas of law. It is important to recognize that ILSs are uniquely underutilized in labour law. Australian environmental, criminal, and industrial disputes consistently draw on international standards. Why not for the plight of workers? ILSs draw their power from supranational influence in that when a case cites an ILS the barrister or solicitor is going beyond legal precedence and into international peer pressure. An ILS can be appropriately used to highlight that Australian or Queensland legislation does not conform to a Convention or Recommendation. However, should the case deal with a breach of existing law based or modified by an ILS, citing the ILS is a good way to remind the court of its origin. It’s a new legal paradigm critically lacking in Queensland’s labour law practice. The following discusses the research methodology used in this paper. It is followed by a comparative discussion of results between the prevalence of ILSs and other international standards in Queensland case history. Finally, evidence showing the international trend of labour disputes using ILSs for victory is discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Multi-output boost (MOB) converter is a novel DC-DC converter unlike the regular boost converter, has the ability to share its total output voltage and to have different series output voltage from a given duty cycle for low and high power applications. In this paper, discrete voltage control with inner hysteresis current control loop has been proposed to keep the simplicity of the control law for the double-output MOB converter, which can be implemented by a combination of analogue and logical ICs or simple microcontroller to constrain the output voltages of MOB converter at their reference voltages against variation in load or input voltage. The salient features of the proposed control strategy are simplicity of implementation and ease to extend to multiple outputs in the MOB converter. Simulation and experimental results are presented to show the validity of control strategy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A high voltage power converter is presented in this paper and is based on a Capacitor-Diode Voltage Multiplier (CDVM) supplied through an inverter. This power converter has the capabilities of generating variable high DC voltage with improved transient response. The simulation results which are presented in this paper verify that due to its fast transient response, this converter can be used as a high DC voltage source in many applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In photovoltaic, fuel cells and storage batteries, the low output DC voltage should be boosted. Therefore, a step-up converter is necessary to boost the low DC voltage for the DC link voltage of the inverter. The main contribution of this chapter is to electrical energy conversion in renewable energy systems based on multilevel inverters. Different configuration of renewable energy systems based on power converters will be discussed in detail. Finally, a new single inductor Multi-Output Boost (MOB) converter is proposed, which is compatible with the diode-clamped configuration. Steady state and dynamic analyses have been carried out in order to show the validity of the proposed topology. Then the joint circuit of the proposed DC-DC converter with a three-level diode-clamped converter is presented in order to have a series regulated voltage at the DC link voltage of the diode-clamped inverter. MOB converter can boost the low input DC voltage of the renewable energy sources and at the same time adjust the voltage across each capacitor to the desired voltage levels, thereby solving the main problem associated with capacitor voltage imbalance in this type of multilevel converter.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A high voltage pulsed power supply is proposed in this paper based on oscillation between an inductor and a capacitor in an LC circuit. A two-leg resonant circuit, supplied through an inverter with an alternative voltage waveform, can generate output voltage up to four times an input voltage magnitude. Bipolar and unipolar modulations are used in a single phase inverter to analyse their effects on the proposed resonant converter. Simulations have been carried out to evaluate the proposed topology and control.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a high voltage pulsed power system based on low voltage switch-capacitor units connected to a current source for several applications such as plasma systems. A buck-boost converter topology is used to utilize the current source and a series of low voltage switch-capacitor units is connected to the current source in order to provide high voltage with high voltage stress (dv/dt) as demanded by loads. This pulsed power converter is flexible in terms of energy control, in that the stored energy in the current source can be adjusted by changing the current magnitude to significantly improve the efficiency of various systems with different requirements. Output voltage magnitude and stress (dv/dt) can be controlled by a proper selection of components and control algorithm to turn on and off switching devices.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Electromagnetic compatibility of power electronic systems becomes an engineering discipline and it should be considered at the beginning stage of a design. Thus, a power electronics design becomes more complex and challenging and it requires a good communication between EMI and Power electronics experts. Three major issues in designing a power electronic system are Losses, EMI and Harmonics. These issues affect system cost, size, efficiency and quality and it is a tradeoff between these factors when we design a power converter.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An algorithm based on the concept of Kalman filtering is proposed in this paper for the estimation of power system signal attributes, like amplitude, frequency and phase angle. This technique can be used in protection relays, digital AVRs, DSTATCOMs, FACTS and other power electronics applications. Furthermore this algorithm is particularly suitable for the integration of distributed generation sources to power grids when fast and accurate detection of small variations of signal attributes are needed. Practical considerations such as the effect of noise, higher order harmonics, and computational issues of the algorithm are considered and tested in the paper. Several computer simulations are presented to highlight the usefulness of the proposed approach. Simulation results show that the proposed technique can simultaneously estimate the signal attributes, even if it is highly distorted due to the presence of non-linear loads and noise.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents an analysis of phasor measurement method for tracking the fundamental power frequency to show if it has the performance necessary to cope with the requirements of power system protection and control. In this regard, several computer simulations presenting the conditions of a typical power system signal especially those highly distorted by harmonics, noise and offset, are provided to evaluate the response of the Phasor Measurement (PM) technique. A new method, which can shorten the delay of estimation, has also been proposed for the PM method to work for signals free of even-order harmonics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a new DC-DC Multi-Output Boost (MOB) converter which can share its total output between different series of output voltages for low and high power applications. This configuration can be utilised instead of several single output power supplies. This is a compatible topology for a diode-clamed inverter in the grid connection systems, where boosting low rectified output-voltage and series DC link capacitors is required. To verify the proposed topology, steady state and dynamic analysis of a MOB converter are examined. A simple control strategy has been proposed to demonstrate the performance of the proposed topology for a double-output boost converter. The topology and its control strategy can easily be extended to offer multiple outputs. Simulation and experimental results are presented to show the validity of the control strategy for the proposed converter.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper proposes a method for power flow control between utility and microgrid through back-to-back converters, which facilitates desired real and reactive power flow between utility and microgrid. In the proposed control strategy, the system can run in two different modes depending on the power requirement in the microgrid. In mode-1, specified amount of real and reactive power are shared between the utility and the microgrid through the back-to-back converters. Mode-2 is invoked when the power that can be supplied by the DGs in the microgrid reaches its maximum limit. In such a case, the rest of the power demand of the microgrid has to be supplied by the utility. An arrangement between DGs in the microgrid is proposed to achieve load sharing in both grid connected and islanded modes. The back-to-back converters also provide total frequency isolation between the utility and the microgrid. It is shown that the voltage or frequency fluctuation in the utility side has no impact on voltage or power in microgrid side. Proper relay-breaker operation coordination is proposed during fault along with the blocking of the back-to-back converters for seamless resynchronization. Both impedance and motor type loads are considered to verify the system stability. The impact of dc side voltage fluctuation of the DGs and DG tripping on power sharing is also investigated. The efficacy of the proposed control ar-rangement has been validated through simulation for various operating conditions. The model of the microgrid power system is simulated in PSCAD.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes control methods for proper load sharing between parallel converters connected in a microgrid and supplied by distributed generators (DGs). It is assumed that the microgrid spans a large area and it supplies loads in both in grid connected and islanded modes. A control strategy is proposed to improve power quality and proper load sharing in both islanded and grid connected modes. It is assumed that each of the DGs has a local load connected to it which can be unbalanced and/or nonlinear. The DGs compensate the effects of unbalance and nonlinearity of the local loads. Common loads are also connected to the microgrid, which are supplied by the utility grid under normal conditions. However during islanding, each of the DGs supplies its local load and shares the common load through droop characteristics. Both impedance and motor loads are considered to verify the system response. The efficacy of the controller has been validated through simulation for various operating conditions using PSCAD. It has been found through simulation that the total Harmonic Distortion (THD) of the of the microgrid voltage is about 10% and the negative and zero sequence component are around 20% of the positive sequence component before compensation. After compensation, the THD remain below 0.5%, whereas, negative and zero sequence components of the voltages remain below 0.02% of the positive sequence component.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In 1999 I convened Industrial Relations, the annual ADSA Conference hosted by QUT in Brisbane. This event was promoted as ‘a conference exploring the links between theatre scholarship and professional theatre practice’. As well as academics, there was to be substantial representation by ‘industry professionals’, although interest from the latter category turned out to be modest. One day of the conference was designated a special ‘Links with Industry’ day, during which the Association launched its now defunct ADSAIL (ADSA Industry Links) initiative. Keynote speaker Wesley Enoch commented on ‘the very strong resistance in “the industry” to acknowledging any role of academics’. ‘What is the practical role of having them?’ he asked the ‘them’ gathered before him. In a letter declining our invitation to speak (he later changed his mind), David Williamson remarked that he always felt ‘uneasy at such conferences’: My view of my work is that I’ve successfully filled theatres for 30 years now, something dramatists are supposed to do. I suppose there’s part of me that hopes this will be celebrated. It often is, but rarely in academic drama departments …. Perhaps in fifty years time someone in academe will realise that I wasn’t just reinforcing the attitudes of the Anglo Celtic ruling class. Several years on it seems timely to revisit Industrial Relations; to look again at the extent to which problems of intercultural communication between industry and academy are being addressed. And what are the implications of this for the ADSA History project, which seeks to investigate ADSA’s contribution to the development of theatre / performance studies in Australasia? What are the ‘external’ impacts of ADSA’s ongoing conference enterprise, and how might these be measured? Reflections from delegates on these and other questions will be warmly encouraged.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

These papers were presented at “Industrial Relations”, the Australasian Drama Studies Association conference hosted by Theatre & Teaching Studies in the Academy of the Arts, Queensland University of Technology, from the 5th to the 9th of July, 1999. Conference delegates included scholars and artists from across the tertiary education and professional theatre sectors, including, of course, many individuals who work across and between both those worlds. More than a hundred delegates from Australia, New Zealand, England, Belgium and Canada attended the week’s events, which included: • Over sixty conference papers covering a variety of topics from project reports to academy/industry partnerships, theatre history, audience reception studies, health & safety, cultural policy, performance theory, theatre technology and more; • Performances ranging from drama to dance, music and cabaret; • Workshops, panel discussions, forums and interviews; • Keynote addresses from Wesley Enoch, Josette Feral and Keith Johnstone; and • A special “Links with Industry” day, which included the launch of ADSA’s “Links with Industry” brochure, an interview between Mark Radvan and David Williamson, and a panel session featuring Jules Holledge, Zane Trow, Katharine Brisbane, John Kotzas, Gay McAuley and David Watt.