918 resultados para High-speed digital imaging
Resumo:
In this paper we present the methodological procedures involved in the digital imaging in mesoscale of a block of travertines rock of quaternary age, originating from the city of Acquasanta, located in the Apennines, Italy. This rocky block, called T-Block, was stored in the courtyard of the Laboratório Experimental Petróleo "Kelsen Valente" (LabPetro), of Universidade Estadual de Campinas (UNICAMP), so that from it were performed Scientific studies, mainly for research groups universities and research centers working in brazilian areas of reservoir characterization and 3D digital imaging. The purpose of this work is the development of a Model Solid Digital, from the use of non-invasive techniques of digital 3D imaging of internal and external surfaces of the T-Block. For the imaging of the external surfaces technology has been used LIDAR (Light Detection and Range) and the imaging surface Interior was done using Ground Penetrating Radar (GPR), moreover, profiles were obtained with a Gamma Ray Gamae-spectômetro laptop. The goal of 3D digital imaging involved the identification and parameterization of surface geological and sedimentary facies that could represent heterogeneities depositional mesoscale, based on study of a block rocky with dimensions of approximately 1.60 m x 1.60 m x 2.70 m. The data acquired by means of terrestrial laser scanner made available georeferenced spatial information of the surface of the block (X, Y, Z), and varying the intensity values of the return laser beam and high resolution RGB data (3 mm x 3 mm), total points acquired 28,505,106. This information was used as an aid in the interpretation of radargrams and are ready to be displayed in rooms virtual reality. With the GPR was obtained 15 profiles of 2.3 m and 2 3D grids, each with 24 sections horizontal of 1.3 and 14 m vertical sections of 2.3 m, both the Antenna 900 MHz to about 2600 MHz antenna. Finally, the use of GPR associated with Laser Scanner enabled the identification and 3D mapping of 3 different radarfácies which were correlated with three sedimentary facies as had been defined at the outset. The 6 profiles showed gamma a low amplitude variation in the values of radioactivity. This is likely due to the fact of the sedimentary layers profiled have the same mineralogical composition, being composed by carbonate sediments, with no clay in siliciclastic pellitic layers or other mineral carrier elements radioactive
Resumo:
Objective: To evaluate the influence of alternative erasing times of DenOptix (R) (Dentsply/Gendex, Chicargo, IL) digital plates oil subjective image quality and the probability of double exposure image not Occurring.Methods: Human teeth were X-rayed with phosphor plates using tell different erasing times. Two observers evaluated the images for subjective Image quality (sharpness, brightness, contrast, enamel definition, dentin definition and dentin-enamal Junction definition) and for the presence or absence of double exposure image. Spearman's correlation analysis and ANOVA was performed to verify the existence ora linear association between the subjective image quality parameters and the alternative erasing times. A contingency table was constructed to evaluate the agreement among the observers, and a binominal logistic regression was performed to verify the correlation between the erasing time and the probability of double exposure image not occurring.Results: All 6 parameters or image quality were rated high by the examiners for the erasing times between 25 s and 130 s. The same erasing time range, from 25 to 130 s, was considered a safe erasing time interval, with no probability of a double exposure image Occurring.Conclusions: The alternative erasing times from 25 s to 130 s showed high quality and no probability of double image Occurrence. Thus, it is possible to reduce the operating time or the DenOptix (R) digital system Without jeopardizing the diagnostic task.Dentomaxillofacial Radiology (2010) 39, 23-27. doi: 10.1259/dmfr/49065239.
Resumo:
P>AimTo compare the efficacy of different digital radiographic imaging systems for determining the length of endodontic files.MethodologyK-type endodontic files were introduced into the canals of 40 extracted human permanent single-rooted teeth and fixed in place at random lengths. The teeth were radiographed using Digora Optime (R), CygnusRay MPS (R) and CDR Wireless (R) digital imaging systems. Six observers measured every file length in all the images and repeated this procedure in 50% of the image samples, and assigned a score to the level of difficulty found. Analysis of variance for differences between digital systems and Tukey's test were performed. The level of intraobserver agreement was measured by intraclass correlation. The assigned scores were evaluated by Kruskal-Wallis and Dunn's tests.ResultsThe CDR Wireless values did not differ significantly from the actual lengths and the CygnusRay MPS values. The Digora Optime system was significantly different from the others and overestimated the values (P < 0.05). The Digora Optime was significantly easier to use for taking measurements and the CygnusRay MPS the most difficult (P < 0.05). All digital radiographic imaging systems showed excellent agreement with the Intraclass Correlation Coefficient > 0.95.ConclusionsThe three digital radiographic imaging systems were precise. The CDR Wireless system was significantly more accurate in determining endodontic file lengths, and similarly to Digora Optime, was considered the least difficult to use when assessing endodontic file lengths.
Resumo:
The influence of the type of rotary cutting instrument on bone repair after osteotomy in swine jaw, was evaluated using digital and densitometric radiographic examinations, at controlled times. Two cross-sectional dissections were made through the base of the right jaw, one using a high speed rotary instrument and the other using low speed, both with liquid cooling. After established periods the animals were sacrificed and their jaws removed for direct and indirect digital radiographic and densitometric studies using the CROMOX, DIGORA and ODR systems. In the initial periods (7 and 28 days) the bone density was higher in osteotomy areas performed with high rotation speeds, and in the final periods (60 and 90 days) the bone density was higher in the osteotomies performed with low rotation, indicating a better final bone repair with the use of low rotation. The qualitative analysis of the repair process was made by the ODR system which obtained three-dimensional and coloured digital images, which enable the bone thickness to be measured using an aluminium wedge. This showed that by twenty-eight days the bone repair was already apparently complete. © 2010 SECOM.
Resumo:
Includes bibliography
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
There is a demand for technologies able to assess the perfusion of surgical flaps quantitatively and reliably to avoid ischemic complications. The aim of this study is to test a new high-speed high-definition laser Doppler imaging (LDI) system (FluxEXPLORER, Microvascular Imaging, Lausanne, Switzerland) in terms of preoperative mapping of the vascular supply (perforator vessels) and postoperative flow monitoring. The FluxEXPLORER performs perfusion mapping of an area 9 x 9 cm with a resolution of 256 x 256 pixels within 6 s in high-definition imaging mode. The sensitivity and predictability to localize perforators is expressed by the coincidence of preoperatively assessed LDI high flow spots with intraoperatively verified perforators in nine patients. 18 free flaps are monitored before, during, and after total ischemia. 63% of all verified perforators correspond to a high flow spot, and 38% of all high flow spots correspond to a verified perforator (positive predictive value). All perfused flaps reveal a value of above 221 perfusion units (PUs), and all values obtained in the ischemic flaps are beneath 187 PU. In summary, we conclude that the present LDI system can serve as a reliable, fast, and easy-to-handle tool to detect ischemia in free flaps, whereas perforator vessels cannot be detected appropriately.
Resumo:
BACKGROUND: Digital imaging methods are a centrepiece for diagnosis and management of macular disease. A recently developed imaging device is composed of simultaneous confocal scanning laser ophthalmoscopy (SLO) and optical coherence tomography (OCT). By means of clinical samples the benefit of this technique concerning diagnostic and therapeutic follow-up will be assessed. METHODS: The combined OCT-SLO-System (Ophthalmic Technologies Inc., Toronto, Canada) allows for confocal en-face fundus imaging and high resolution OCT scanning at the same time. OCT images are obtained from transversal line scans. One light source and the identical scanning rate yield a pixel-to-pixel correspondence of images. Three-dimensional thickness maps are derived from C-scan stacking. RESULTS: We followed-up patients with cystoid macular edema, pigment epithelium detachment, macular hole, venous branch occlusion, and vitreoretinal tractions during their course of therapy. The new imaging method illustrates the reduction of cystoid volume, e.g. after intravitreal injections of either angiostatic drugs or steroids. C-scans are used for appreciation of lesion diameters, visualisation of pathologies involving the vitreoretinal interface, and quantification of retinal thickness change. CONCLUSION: The combined OCT-SLO system creates both topographic and tomographic images of the retina. New therapeutic options can be followed-up closely by observing changes in lesion thickness and cyst volumes. For clinical use further studies are needed.
Resumo:
OBJECT: Ultrasound may be a reliable but simpler alternative to intraoperative MR imaging (iMR imaging) for tumor resection control. However, its reliability in the detection of tumor remnants has not been definitely proven. The aim of the study was to compare high-field iMR imaging (1.5 T) and high-resolution 2D ultrasound in terms of tumor resection control. METHODS: A prospective comparative study of 26 consecutive patients was performed. The following parameters were compared: the existence of tumor remnants after presumed radical removal and the quality of the images. Tumor remnants were categorized as: detectable with both imaging modalities or visible only with 1 modality. RESULTS: Tumor remnants were detected in 21 cases (80.8%) with iMR imaging. All large remnants were demonstrated with both modalities, and their image quality was good. Two-dimensional ultrasound was not as effective in detecting remnants<1 cm. Two remnants detected with iMR imaging were missed by ultrasound. In 2 cases suspicious signals visible only on ultrasound images were misinterpreted as remnants but turned out to be a blood clot and peritumoral parenchyma. The average time for acquisition of an ultrasound image was 2 minutes, whereas that for an iMR image was approximately 10 minutes. Neither modality resulted in any procedure-related complications or morbidity. CONCLUSIONS: Intraoperative MR imaging is more precise in detecting small tumor remnants than 2D ultrasound. Nevertheless, the latter may be used as a less expensive and less time-consuming alternative that provides almost real-time feedback information. Its accuracy is highest in case of more confined, deeply located remnants. In cases of more superficially located remnants, its role is more limited.
Resumo:
Atomic force microscopy (AFM) is a powerful imaging technique that allows recording topographical information of membrane proteins under near-physiological conditions. Remarkable results have been obtained on membrane proteins that were reconstituted into lipid bilayers. High-resolution AFM imaging of native disk membranes from vertebrate rod outer segments has unveiled the higher-order oligomeric state of the G protein-coupled receptor rhodopsin, which is highly expressed in disk membranes. Based on AFM imaging, it has been demonstrated that rhodopsin assembles in rows of dimers and paracrystals and that the rhodopsin dimer is the fundamental building block of higher-order structures.
Resumo:
In this article research into the uniaxial tensile strength of Al2O3 monolithic ceramic is presented. The experimental procedure of the spalling of long bars is investigated from different approaches. This method is used to obtain the tensile strength at high strain rates under uniaxial conditions. Different methodologies proposed by several authors are used to obtain the tensile strength. The hypotheses needed for the experimental set-up are also checked, and the requirements of the set-up and the variables are also studied by means of numerical simulations. The research shows that the shape of the projectile is crucial to achieve successfully tests results. An experimental campaign has been carried out including high speed video and a digital image correlation system to obtain the tensile strength of alumina. Finally, a comparison of the test results provided by three different methods proposed by different authors is presented. The tensile strength obtained from the three such methods on the same specimens provides contrasting results. Mean values vary from one method to another but the trends are similar for two of the methods. The third method gives less scatter, though the mean values obtained are lower and do not follow the same trend as the other methods for the different specimens.
Resumo:
FTTH (fibra hasta el hogar) es actualmente, junto con la banda ancha móvil, la principal evolución tecnológica en Redes y Servicios de Telecomunicaciones. Se prevé que en los próximos años, el despliegue de las redes FTTH se vea incrementado de manera significativa, gracias al interés creciente tanto de Operadores de Telecomunicaciones como de Organismos Gubernamentales. Este despliegue (que en el año 2013 ya se está haciendo realidad) llevará servicios de muy alta velocidad (superiores a 100 Mbps, incluso 1 Gbps) de manera masiva a los hogares, exigiendo nuevos requisitos y prestaciones en la red del hogar de los clientes. Se abre aquí, por tanto, un campo de exploración novedoso, incipiente y de requerimientos cada vez más exigentes. De hecho, sin duda, la red del hogar es uno de los elementos fundamentales para el éxito de las redes y servicios en FTTH. Debido a todo lo anterior, se convierte en una necesidad para el sector de las Telecomunicaciones el encontrar soluciones a los problemas anteriormente mencionados. Con objeto de contribuir al análisis de soluciones, este proyecto se enfoca en dos temas, ambos relacionados con la problemática ya mencionada en la red del hogar: Prospección e identificación de soluciones tecnológicas avanzadas para la red del hogar. Descrito en capítulos 2, 3 y 4. En ellos se realiza un estudio detallado de la situación actual y tendencias futuras de los dispositivos utilizados en la red del hogar. Este estudio está enfocado en la distribución de señales de muy alto ancho de banda (en torno a los 100 Mbps por segundo) en el hogar. Diseño y desarrollo de una aplicación que permita determinar la calidad de experiencia de cliente (QoE) de un servicio de televisión IP (IPTV). Descrito en capítulos 5 y 6. Se ha seleccionado este tipo de servicios debido a que son los que requieren mayores prestaciones tanto de la red de transporte como de la red del hogar y, al mismo tiempo, son los más complicados de medir debido a la fuerte componente de subjetividad del usuario final. Una red del hogar correctamente diseñada debe cumplir de manera equilibrada los requisitos demandados tanto por el operador como por el cliente o usuario final del servicio. Los requisitos del operador se centran principalmente en el control de la inversión (CAPEX) y del gasto de mantenimiento de la red del hogar (OPEX). El usuario, por otra parte, requiere sencillez en la instalación y mínimo número de elementos a instalar (cero intrusismo, ausencia de cableado). Para adaptarse a estos requerimientos, existe una serie de dispositivos y tecnologías que buscan encontrar el punto de equilibrio entre necesidades de operadores y de clientes finales. Las soluciones actualmente utilizadas pueden dividirse en soluciones cableadas e inalámbricas. También existen soluciones híbridas. Todas ellas se describen en detalle en los capítulos 3 y 4. Al final del estudio se concluye que, con la tecnología actual, es preferible el uso de soluciones cableadas tipo Ethernet o POF. Es recomendable no usar soluciones PLC de manera extensiva (G.hn puede ser una alternativa a futuro) y, en caso de no requerir cableado, utilizar WiFi 11n con frecuencias de 5 GHz, así como sus evoluciones, WiFi 11ac y 11ad. La aplicación desarrollada, explicada en los capítulos 5 y 6, permite capturar y medir en tiempo real la señal de televisión IP que se entrega al usuario. Esta aplicación estimará, a partir de dichas medidas, la calidad de la señal entregada. Para ello tendrá en cuenta el tipo de descodificador utilizado por el usuario así como la red empleada (red FTTH de Telefónica). Esta aplicación podría ser utilizada en los centros de atención técnica de las operadoras de telecomunicaciones, determinando así la relación existente entre reclamaciones recibidas y calidad de servicio medida por la aplicación. Asimismo, aparte de realizar medidas en tiempo real, la aplicación vuelca las medidas realizadas y alarmas detectadas en ficheros log, facilitando el análisis técnico de los problemas e incidencias registrados por dichos centros técnicos. Igualmente, esta aplicación puede ser utilizada para el proceso de certificación de equipamiento de red del hogar o incluso como herramienta para profundizar en parámetros teóricos y criterios de medida de calidad de servicio en IPTV. ABSTRACT. FTTH (Fiber To The Home) and mobile broadband are currently the main technological trend in the Network and Telecommunications Services area. In the next few years, the deployment of FTTH networks will experiment a significant increase, due to the growing interest of both telecommunications operators and government agencies. This deployment (that is becoming a reality) which will massively carry high-speed services to households (speeds of more than 100 Mbps, even 1 Gbps) will demand new requirements and features in the customer’s home network. It can be found here a new and emerging field of exploration, with increasingly demanding requirements. In fact, the home network is one of the key elements for the success of FTTH network and services. Due to the aforementioned, it is a necessity for the telecommunications industry to find solutions to these problems. In order to contribute into the solution analysis, this project focuses on two subjects, both related to the problems of home networking: Exploratory research and identification of advanced technology solutions for the home network. Described in chapters 2, 3 and 4. These chapters show a detailed study of the current situation and future trends of the devices used at the home network. It focuses on the distribution of very high bandwidth signals (around 100 Mbps per second) in the customer’s home. Design and development of an application to evaluate customer’s quality of experience (QoE) of an IP television service (IPTV). Described in chapters 5 and 6. IPTV service has been selected because it requires higher performance both from the transport and the home networks and, at the same time, it is the most difficult to measure due to the strong component of subjectivity of the end user. A correct design of the home network must meet the requirements demanded both by the network operator and the customer (end user of the service). Network operator requirements mainly focus on reduced capital expenditures (CAPEX) and operational expenditures (OPEX). Additionally, the final user requires a simple and easy installation and also the minimum number of items to install (zero intrusion, lack of wiring, etc.). Different devices and technologies seek to find a balance between these two requirements (network operators and final users requirements). Solutions available in the market can be divided into wired and wireless. There are also hybrid solutions. All of them are described thoroughly in the first part of the project. The conclusion at the end of the study recommends the use of wired technologies like Ethernet or POF. Additionally, the use of PLC is not advised (G.hn can be an alternative in the future) and, in the case of not requiring wiring, the use of 11ac and 11ad WiFi is advised. The application developed in the second part of the project allows capturing and measuring the real-time IPTV signal delivered to the user. This application will estimate the delivered signal quality from the captured measurements. For this purpose, it will also consider the type of decoder installed on the customer’s premises and the transport network (Telefonica’s FTTH network). This application could be used at the operator’s technical service centres, determining in this way the relationship between user’s complaints and the quality of service measured. Additionally, this application can write all the measurements and alarms in log files, making easier the technical analysis of problems and impairments recorded by the technical centres. Finally, the application can also be used for the certification process of home networking equipment (i.e. decoders) or even as a tool to deepen theoretical parameters and measuring criteria of quality of service in IPTV.
Resumo:
Considerable evidence exists to support the hypothesis that the hippocampus and related medial temporal lobe structures are crucial for the encoding and storage of information in long-term memory. Few human imaging studies, however, have successfully shown signal intensity changes in these areas during encoding or retrieval. Using functional magnetic resonance imaging (fMRI), we studied normal human subjects while they performed a novel picture encoding task. High-speed echo-planar imaging techniques evaluated fMRI signal changes throughout the brain. During the encoding of novel pictures, statistically significant increases in fMRI signal were observed bilaterally in the posterior hippocampal formation and parahippocampal gyrus and in the lingual and fusiform gyri. To our knowledge, this experiment is the first fMRI study to show robust signal changes in the human hippocampal region. It also provides evidence that the encoding of novel, complex pictures depends upon an interaction between ventral cortical regions, specialized for object vision, and the hippocampal formation and parahippocampal gyrus, specialized for long-term memory.
Resumo:
Plasmodium parasites, the causative agents of malaria, first invade and develop within hepatocytes before infecting red blood cells and causing symptomatic disease. Because of the low infection rates in vitro and in vivo, the liver stage of Plasmodium infection is not very amenable to biochemical assays, but the large size of the parasite at this stage in comparison with Plasmodium blood stages makes it accessible to microscopic analysis. A variety of imaging techniques has been used to this aim, ranging from electron microscopy to widefield epifluorescence and laser scanning confocal microscopy. High-speed live video microscopy of fluorescent parasites in particular has radically changed our view on key events in Plasmodium liver-stage development. This includes the fate of motile sporozoites inoculated by Anopheles mosquitoes as well as the transport of merozoites within merosomes from the liver tissue into the blood vessel. It is safe to predict that in the near future the application of the latest microscopy techniques in Plasmodium research will bring important insights and allow us spectacular views of parasites during their development in the liver.
Resumo:
The electrical and optical characteristics of a cylindrical alumina insulator (94% Al203) have been measured under ultra-high vacuum (P < 10-8 mBar) conditions. A high-resolution CCD camera was used to make real-time optical recordings of DC prebreakdown luminescence from the ceramic, under conditions where DC current magnitudes were limited to less than 50μA. Two concentric metallized rings formed a pair of co-axial electrodes, on the end-face of the alumina tube; a third 'transparent' electrode was employed to study the effect of an orthogonal electric field upon the radial conduction processes within the metallized alumina specimen. The wavelength-spectra of the emitted light was quantified using a high-speed scanning monochromator and photo-multiplier tube detector. Concurrent electrical measurements were made alongside the recording of optical-emission images. An observed time-dependence of the photon-emission is correlated with a time-variation observed in the DC current-voltage characteristics of the alumina. Optical images were also recorded of pulsed-field surface-flashover events on the alumina ceramic. An intensified high-speed video technique provided 1ms frames of surface-flashover events, whilst 100ns frames were achieved using an ultra high-speed fast-framing camera. By coupling this fast-frame camera to a digital storage oscilloscope, it was possible to establish a temporal correlation between the application of a voltage-pulse to the ceramic and the evolution of photonic emissions from the subsequent surface-flashover event. The electro-optical DC prebreakdown characteristics of the alumina are discussed in terms of solid-state photon-emission processes, that are believed to arise from radiative electron-recombination at vacancy-defects and substitutional impurity centres within the surface-layers of the ceramic. The physical nature of vacancy-defects within an alumina dielectric is extensively explored, with a particular focus placed upon the trapped electron energy-levels that may be present at these defect centres. Finally, consideration is given to the practical application of alumina in the trigger-ceramic of a sealed triggered vacuum gap (TVG) switch. For this purpose, a physical model describing the initiation of electrical breakdown within the TVG regime is proposed, and is based upon the explosive destabilisation of trapped charge within the alumina ceramic, triggering the onset of surface-flashover along the insulator. In the main-gap prebreakdown phase, it is suggested that the electrical-breakdown of the TVG is initiated by the low-field 'stripping' of prebreakdown electrons from vacancy-defects in the ceramic under the influence of an orthogonal main-gap electric field.