936 resultados para High frame rate display
Resumo:
Abstract Objective: To perform a comparative dosimetric analysis, based on computer simulations, of temporary balloon implants with 99mTc and balloon brachytherapy with high-dose-rate (HDR) 192Ir, as boosts to radiotherapy. We hypothesized that the two techniques would produce equivalent doses under pre-established conditions of activity and exposure time. Materials and Methods: Simulations of implants with 99mTc-filled and HDR 192Ir-filled balloons were performed with the Siscodes/MCNP5, modeling in voxels a magnetic resonance imaging set related to a young female. Spatial dose rate distributions were determined. In the dosimetric analysis of the protocols, the exposure time and the level of activity required were specified. Results: The 99mTc balloon presented a weighted dose rate in the tumor bed of 0.428 cGy.h-1.mCi-1 and 0.190 cGyh-1.mCi-1 at the balloon surface and at 8-10 mm from the surface, respectively, compared with 0.499 and 0.150 cGyh-1.mCi-1, respectively, for the HDR 192Ir balloon. An exposure time of 24 hours was required for the 99mTc balloon to produce a boost of 10.14 Gy with 1.0 Ci, whereas only 24 minutes with 10.0 Ci segments were required for the HDR 192Ir balloon to produce a boost of 5.14 Gy at the same reference point, or 10.28 Gy in two 24-minutes fractions. Conclusion: Temporary 99mTc balloon implantation is an attractive option for adjuvant radiotherapy in breast cancer, because of its availability, economic viability, and similar dosimetry in comparison with the use of HDR 192Ir balloon implantation, which is the current standard in clinical practice.
Resumo:
One of the primary goals for food packages is to protect food against harmful environment, especially oxygen and moisture. The gas transmission rate is the total gas transport through the package, both by permeation through the package material and by leakage through pinholes and cracks. The shelf life of a product can be extended, if the food is stored in a gas tight package. Thus there is a need to test gas tightness of packages. There are several tightness testing methods, and they can be broadly divided into destructive and nondestructive methods. One of the most sensitive methods to detect leaks is by using a non destructive tracer gas technique. Carbon dioxide, helium and hydrogen are the most commonly used tracer gases. Hydrogen is the lightest and the smallest of all gases, which allows it to escape rapidly from the leak areas. The low background concentration of H2 in air (0.5 ppm) enables sensitive leak detection. With a hydrogen leak detector it is also possible to locate leaks. That is not possible with many other tightness testing methods. The experimental work has been focused on investigating the factors which affect the measurement results with the H2leak detector. Also reasons for false results were searched to avoid them in upcoming measurements. From the results of these experiments, the appropriate measurement practice was created in order to have correct and repeatable results. The most important thing for good measurement results is to keep the probe of the detector tightly against the leak. Because of its high diffusion rate, the HZ concentration decreases quickly if holding the probe further away from the leak area and thus the measured H2 leaks would be incorrect and small leaks could be undetected. In the experimental part hydrogen, oxygen and water vapour transmissions through laser beam reference holes (diameters 1 100 μm) were also measured and compared. With the H2 leak detector it was possible to detect even a leakage through 1 μm (diameter) within a few seconds. Water vapour did not penetrate even the largest reference hole (100 μm), even at tropical conditions (38 °C, 90 % RH), whereas some O2 transmission occurred through the reference holes larger than 5 μm. Thus water vapour transmission does not have a significant effect on food deterioration, if the diameter of the leak is less than 100 μm, but small leaks (5 100 μm) are more harmful for the food products, which are sensitive to oxidation.
Resumo:
Vehicle operations in underwater environments are often compromised by poor visibility conditions. For instance, the perception range of optical devices is heavily constrained in turbid waters, thus complicating navigation and mapping tasks in environments such as harbors, bays, or rivers. A new generation of high-definition forward-looking sonars providing acoustic imagery at high frame rates has recently emerged as a promising alternative for working under these challenging conditions. However, the characteristics of the sonar data introduce difficulties in image registration, a key step in mosaicing and motion estimation applications. In this work, we propose the use of a Fourier-based registration technique capable of handling the low resolution, noise, and artifacts associated with sonar image formation. When compared to a state-of-the art region-based technique, our approach shows superior performance in the alignment of both consecutive and nonconsecutive views as well as higher robustness in featureless environments. The method is used to compute pose constraints between sonar frames that, integrated inside a global alignment framework, enable the rendering of consistent acoustic mosaics with high detail and increased resolution. An extensive experimental section is reported showing results in relevant field applications, such as ship hull inspection and harbor mapping
Resumo:
It is widely recognized that pharmacokinetic optimization needs to be addressed early in drug discovery to reduce the high failure rate in bringing drugs to market. Poor absorption, too short duration of action due to high elimination rate, or the presence of active metabolites are examples of properties that can potentially lead to unsuccessful clinical programmes. Here I describe a brief overview of advantages and molecular strategies for improving metabolic and pharmacokinetic properties applied to the discovery of fluconazol, beta-blockers, ritonavir and ezetimibe and to the development of the prodrugs enalapril and bambuterol.
Resumo:
Sensor-based robot control allows manipulation in dynamic environments with uncertainties. Vision is a versatile low-cost sensory modality, but low sample rate, high sensor delay and uncertain measurements limit its usability, especially in strongly dynamic environments. Force is a complementary sensory modality allowing accurate measurements of local object shape when a tooltip is in contact with the object. In multimodal sensor fusion, several sensors measuring different modalities are combined to give a more accurate estimate of the environment. As force and vision are fundamentally different sensory modalities not sharing a common representation, combining the information from these sensors is not straightforward. In this thesis, methods for fusing proprioception, force and vision together are proposed. Making assumptions of object shape and modeling the uncertainties of the sensors, the measurements can be fused together in an extended Kalman filter. The fusion of force and visual measurements makes it possible to estimate the pose of a moving target with an end-effector mounted moving camera at high rate and accuracy. The proposed approach takes the latency of the vision system into account explicitly, to provide high sample rate estimates. The estimates also allow a smooth transition from vision-based motion control to force control. The velocity of the end-effector can be controlled by estimating the distance to the target by vision and determining the velocity profile giving rapid approach and minimal force overshoot. Experiments with a 5-degree-of-freedom parallel hydraulic manipulator and a 6-degree-of-freedom serial manipulator show that integration of several sensor modalities can increase the accuracy of the measurements significantly.
Resumo:
The purpose of the thesis is to examine the added value of combining value and momentum indicators in the Swiss stock exchange. Value indicators employed are P/E, EV/EBITDA, P/CF, P/B ja P/S. Momentum indicators examined are 52-week high, acceleration rate, 12-month past return and 6-month past return. The thesis examines whether the composite value measures based on the above mentioned ratios can add value and whether the inclusion of momentum can further improve the risk return profile of the value portfolios. The data is gathered from the Swiss equity market during the sample period from May 2001 to May 2011. Previous studies have shown that composite value measures can somewhat add value to the value portfolio strategy. Similarly, recent academic literature have found evidence that momentum works well as a timing indicator for time to entry to value stocks. This study indicates that the added value of composite value measures exists. It also shows that momentum combined to acceleration rate can significantly improve the risk adjusted performance of value-only portfolios.
Resumo:
BACKGROUND: A new procedure for the treatment of esophageal fistula, mainly associated to the ebb esophagojejunal in patients submitted to the total gastrectomy and reconstruction with loop jejunal Rouxen-Y anastomosis is present. METHODS: The method is based in the use of "probe standard enteral prolongated with drain to laminate adapted in extremity", which results in advanced positioning inside the jejunum, making the administration of enteral nutrition possible and impeding ebb esophagojejunal. RESULTS: The authors discuss the theoretical advantages of the procedure and they suggest that the treatment of esofagic fistula with probe prolonged enteral would be suitable in the treatment of the fistula esophagojejunal by preventing the ebb esophagojejunal, which would result in smaller period of duration of the fistula esophagojejunal and it would prevent the high mortality rate. CONCLUSIONS: Preliminary studies demonstrated that this is a technically easy, low cost procedure through the endoscopic use. A prospective evaluation for morbility and mortality related to the method is needed.
Resumo:
Injuries to the main hepatic veins carry a very high mortality rate, regardless of the technique used for repair. Isolated reports of survivors have, for the most part, been managed by hepatic vascular exclusion (EVE) techniques, usually with an atriocaval shunt. Herein we report a case of a severe intrahepatic major hepatic vein injury successfully managed with EVE.
Resumo:
Juxtahepatic veins, retrohepatic vena cava or major hepatic veins injuries carry a very high mortality rate regardless the technique used for its repair. Isolated survivor reports have for the most part been managed by vascular isolation techniques, usually with atriocaval shunt. We report one case with a unique management technique in a patient who sustained gunshot wound to the retrohepatic vena cava. Hemorrhage control had been obtained by intrahepatic balloon tamponade after others maneuvers have failed. The balloon was left in situ for two days as damaged control laparotomy principles and planned reoperation has been chosen.
Resumo:
The pectus excavatum treatment has two different approaches: non-surgical techniques (modified dynamic thoracic compressor, exercises and the vacuum bell) or surgical techniques (silastic or solid silicone implant, open surgical repair like sternochondroplasty and minimally invasive repair). The introduction of Nuss procedure improved the pectus excavatum treatment, but its low acceptance was due to the high complication rate (e.g. cardiac perfuration). The thoracoscopy use for bar mediastinal passage reduced the complication rate. In comparison with sternochondroplasty, the Nuss procedure has smaller incision, less blood loss and less operative time. However, it has more reoperations, complications, longer hospital stay and more readmission rates, more time of thoracic epidural catheter for postoperative analgesia and more need for analgesic after being discharged. Although Nuss procedure has been used in children, patients under ten years must be only observed. The Nuss procedure is applicable to moderate or light symmetrical pectus excavatum, without costal protrusion, in young and adolescents patients. Furthermore, the sternochondroplasty is applicable to severe or asymmetric pectus excavatum, with or without inferior costal protrusion. Therefore, Nuss procedure and sternocondroplasty are not antagonistic procedures, and they must be used in accordance with a treatment organogram and the technique choice must be by functional and aesthetic outcome.
Resumo:
Lanthanides represent the chemical elements from lanthanum to lutetium. They intrinsically exhibit some very exciting photophysical properties, which can be further enhanced by incorporating the lanthanide ion into organic or inorganic sensitizing structures. A very popular approach is to conjugate the lanthanide ion to an organic chromophore structure forming lanthanide chelates. Another approach, which has quickly gained interest, is to incorporate the lanthanide ions into nanoparticle structures, thus attaining improved specific activity and binding capacity. The lanthanide-based reporters usually express strong luminescence emission, multiple narrow emission lines covering a wide wavelength range, and exceptionally long excited state lifetimes enabling timeresolved detection. Because of these properties, the lanthanide-based reporters have found widespread applications in various fields of life. This study focuses on the field of bioanalytical applications. The aim of the study was to demonstrate the utility of different lanthanide-based reporters in homogeneous Förster resonance energy transfer (FRET)-based bioaffinity assays. Several different model assays were constructed. One was a competitive bioaffinity assay that utilized energy transfer from lanthanide chelate donors to fluorescent protein acceptors. In addition to the conventional FRET phenomenon, a recently discovered non-overlapping FRET (nFRET) phenomenon was demonstrated for the first time for fluorescent proteins. The lack of spectral overlap in the nFRET mechanism provides sensitivity and versatility to energy transfer-based assays. The distance and temperature dependence of these phenomena were further studied in a DNA-hybridization assay. The distance dependence of nFRET deviated from that of FRET, and unlike FRET, nFRET demonstrated clear temperature dependence. Based on these results, a possible excitation mechanism operating in nFRET was proposed. In the study, two enzyme activity assays for caspase-3 were also constructed. One of these was a fluorescence quenching-based enzyme activity assay that utilized novel inorganic particulate reporters called upconverting phosphors (UCPs) as donors. The use of UCPs enabled the construction of a simple, rather inexpensive, and easily automated assay format that had a high throughput rate. The other enzyme activity assay took advantage of another novel reporter class, the lanthanidebinding peptides (LBPs). In this assay, energy was transferred from a LBP to a green fluorescent protein (GFP). Using the LBPs it was possible to avoid the rather laborious, often poorly repeatable, and randomly positioned chemical labeling. In most of the constructed assays, time-resolved detection was used to eliminate the interfering background signal caused by autofluorescence. The improved signal-to-background ratios resulted in increased assay sensitivity, often unobtainable in homogeneous assay formats using conventional organic fluorophores. The anti-Stokes luminescence of the UCPs, however, enabled the elimination of autofluorescence even without time-gating, thus simplifying the instrument setup. Together, the studied reporters and assay formats pave the way for increasingly sensitive, simple, and easily automated bioanalytical applications.
Resumo:
Allometry, growth and leaf demography of two Cecropia species, one with ant mutualist (C. glazioui) and another without it (C. hololeuca), were studied in an Atlantic Rain Forest area in the State of Rio de Janeiro, SE Brazil. Stem diameter was allometrically related to height in both species. Cecropia glazioui showed higher annual growth rates and longer internodes than C. hololeuca. Leaf phenology showed a seasonal pattern in both species, but the number of leaves on each plant was more variable along the year in C. hololeuca than in C. glazioui. Survivorship curves for leaves were intermediate between Deevey's Type I and Type II curves, with young leaves of C. glazioui showing a greater survival rate and life expectancy than those of C. hololeuca. Low variability in leaf production throughout the year and high survival rate for young leaves of C. glazioui may be characteristics related to its association with ants.
Resumo:
Differences in age and sex distribution as well as FAB (French-American-British classification) types have been reported for acute leukemias in several countries. We studied the demographics and response to treatment of patients with acute myeloid leukemia (AML) and acute lymphoblastic leukemia (ALL) between 1989 and 2000 in Teresina, Piauí, and compared these results with reports from Brazil and other countries. Complete data concerning 345 patients (230 ALL, 115 AML) were reviewed. AML occurred predominantly in adults (77%), with a median age of 34 years, similar to that found in the southeast of Brazil but lower than the median age in the United States and Europe (52 years). FAB distribution was similar in children and adults and FAB-M2 was the most common type, as also found in Japan. The high frequency of FAB-M3 described in most Brazilian studies and for Hispanics in the United States was not observed. Overall survival for adults was 40%, similar to other studies in Brazil. A high mortality rate was observed during induction. No clinical or hematological parameter influenced survival in the Cox model. ALL presented the characteristic peak of incidence between 2-8 years. Most of the cases were CD10+ pre-B ALL. In 25%, abnormal expression of myeloid antigens was observed. Only 10% of the patients were older than 30 years. Overall survival was better for children. Age and leukocyte count were independent prognostic factors. These data demonstrate that, although there are regional peculiarities, the application of standardized treatments and good supportive care make it possible to achieve results observed in other countries for the same chemotherapy protocols.
Resumo:
Sentinel node (SN) status is the most important prognostic factor for localized melanoma. Usually, patients with Breslow thickness of less than 1.0 mm are not included in SN protocols. However, the literature presents a rate ranging from 3 to 7% of nodal recurrence in thin melanoma. Ulceration, regression and high mitotic rate have been considered to be indications for an SN biopsy. The metastatic potential of the vertical growth phase is uncertain. To correlate pathological features in thin melanoma with SN metastasis, we reviewed 358 patients submitted to SN biopsy. Seventy-seven patients with lesions of 1 mm or smaller were included in the study group. Histological evaluation of the primary tumor included thickness, Clark level, mitotic rate, ulceration, regression, and growth phase. Lymphoscintigraphy was performed on all patients. Lymphatic mapping and gamma probe detection were both used for SN biopsy. Histological examination of SN consisted of hematoxylin-eosin and immunohistochemical staining. Median follow-up was 37 months. Six patients had micrometastases. Statistical analysis by the Fisher test showed that ulceration (P = 0.019), high mitotic rate (P = 0.008) and vertical growth phase (P = 0.002) were positively correlated with micrometastases. If other studies confirm these results, more melanoma patients must be submitted to SN biopsy.
Resumo:
Pelvic floor disorders, such as urinary incontinence (UI) and pelvic organ prolapse (POP), are common disorders in women. Because of the prolonged life expectancy the prevalence of UI and POP and the probability of ending up in surgery are increasing. However, the pathophysiology behind these disorders is still unsolved. The aim of this thesis is to study possible alterations in the connective tissue in the vaginal wall in patients with and without POP. The long-term outcome and complications of mid-urethral slings (MUS) and mesh-augmented POP surgery were studied in heterogenic patient populations. More elastin and a slight increase in immunostaining of type III and V collagens in tissue samples were obtained from patients with POP compared to controls in whom type I collagen was more prominent. The studies assessing the mesh-augmented procedures revealed good efficacy and high patient satisfaction after a long-term follow-up. Patients operated on because of mixed incontinence and with BMI >30 kg/m² reported significantly more urinary symptoms and a lower quality of life than the patients operated on because of stress urinary incontinence and the ones with BMI ≤30 kg/m². The objective outcome was equal between the groups. Mesh exposure through vaginal mucosa occurred in 23 % of the patients after POP surgery, most of these being asymptomatic. There are alterations in connective tissues in patients with POP. Mid-urethral sling procedures produced good long-term cure rates and patient satisfaction. As to the prolapse surgery, in spite of relatively high exposure rate, mesh-augmented procedure proved to be safe and effective method for the correction of POP.