971 resultados para High Field Mri


Relevância:

40.00% 40.00%

Publicador:

Resumo:

A non-weak link joining technique has been developed for YBCO pseudo-crystals fabricated by seeded peritectic solidification based on the formation of a liquid phase which segregates from the platelet boundaries at temperatures above = 920 °C. Electrical and magnetic measurements on these boundaries suggest that their irreversibility field can be as high as 7 T at 77 K in fully oxygenated pseudo-crystals joined along their crystallographic ab-planes which is comparable to the irreversibility behaviour of the adjacent YBCO grains. © 1999 IEEE.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

As we known, the high temperature (77 K) superconducting (HTS) motor is considered as a competitive electrical machine by more and more people. There have been various of designs for HTS motor in the world. However, most of them focus on HTS tapes rather than bulks. Therefore, in order to investigate possibility of HTS bulks on motor application, a HTS magnet synchronous motor which has 75 pieces of YBCO bulks surface mounted on the rotor has been designed and developed in Cambridge University. After pulsed field magnetization (PFM) process, the rotor can trap a 4 poles magnetic field of 375 mT. The magnetized rotor can provide a maximum torque of 49.5 Nm and a maximum power of 7.8 kW at 1500 rpm. © 2010 IEEE.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Computational fluid dynamics (CFD) simulations are becoming increasingly widespread with the advent of more powerful computers and more sophisticated software. The aim of these developments is to facilitate more accurate reactor design and optimization methods compared to traditional lumped-parameter models. However, in order for CFD to be a trusted method, it must be validated using experimental data acquired at sufficiently high spatial resolution. This article validates an in-house CFD code by comparison with flow-field data obtained using magnetic resonance imaging (MRI) for a packed bed with a particle-to-column diameter ratio of 2. Flows characterized by inlet Reynolds numbers, based on particle diameter, of 27, 55, 111, and 216 are considered. The code used employs preconditioning to directly solve for pressure in low-velocity flow regimes. Excellent agreement was found between the MRI and CFD data with relative error between the experimentally determined and numerically predicted flow-fields being in the range of 3-9%. © 2012 American Institute of Chemical Engineers (AIChE).