996 resultados para Head, Isabella.


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The stimulatory effect of vasomodulatory natriuretic peptide hormones on macrophages and peripheral blood leucocytes in mammals is well-established. However, the relationship in lower vertebrates has not been characterised. Expression of atrial natriuretic peptide, ventricular natriuretic peptide and C-type natriuretic peptide-1, and the guanylyl cyclase-linked (GC) natriuretic peptide receptor-A and -B-type receptors (NPR-A and NPR-B, respectively) was determined by PCR from the mRNA of rainbow trout head kidney leucocytes yielding gene fragments with 100% homology to the same respective natriuretic peptide and NPR-A and -B sequences obtained from other rainbow trout tissues. A mixed population of isolated rainbow trout head kidney leucocytes was stimulated in vitro with trout atrial natriuretic peptide (specific NPR-A agonist) and trout C-type natriuretic peptide (NPR-A and -B agonist) as well as the cGMP agonist 8-bromo-cGMP or the GC inhibitor 8-bromo-phenyl-eutheno-cGMP. Respiratory burst was stimulated by trout atrial natriuretic peptide, trout C-type natriuretic peptide-1 and 8-bromo-cGMP in a dose dependant manner with the highest activity as a result of stimulation with trout C-type natriuretic peptide-1 in excess of that achieved by phorbol myristate acetate (PMA). Equimolar concentrations of the inhibitor, inhibited the respiratory burst caused by the natriuretic peptides and 8-bromo-cGMP. The natriuretic peptide receptors on rainbow trout head kidney leucocytes appear to have a stimulatory function with regard to respiratory burst that is activated through a cGMP second messenger pathway and the natriuretic peptides expressed in the head kidney leucocytes may well act in a paracrine/autocrine manner.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Neck injuries are common in high performance combat pilots and have been attributed to high gravitational forces and the non-neutral head postures adopted during aerial combat maneuvers. There is still little known about the pathomechanics of these injuries.

Methods: Six Royal Australian Air Force Hawk pilots flew a sortie that included combinations of three +Gz levels (1, 3, and 5) and four head postures (Neutral, Turn, Extension, and Check-6). Surface electromyography from neck and shoulder muscles was recorded in flight. Three-dimensional measures of head postures adopted in flight were estimated postflight with respect to end-range of the cervical spine using an electromagnetic tracking device.

Results: Mean muscle activation increased significantly with both increasing +Gz and non-neutral head postures. Check-6 at +5 Gz (mean activation of all muscles = 51% MVIC) elicited significantly greater muscle activation in most muscles when compared with Neutral, Extension, and Turn head postures. High levels of muscle co-contraction were evident in high acceleration and non-neutral head postures. Head kinematics showed Check-6 was closest to end-range in any movement plane (86% ROM in rotation) and produced the greatest magnitude of rotation in other planes. Turn and Extension showed a large magnitude of rotation with reference to end-range in the primary plane of motion but displayed smaller rotations in other planes.

Discussion:
High levels of neck muscle activation and co-contraction due to high +Gz and head postures close to end range were evident in this study, suggesting the major influence of these factors on the pathomechanics of neck injuries in high performance combat pilots.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new generation of blood glucose meters is now available for use by people with diabetes and health professionals, but little independent evaluation data is available. Previous models are prone to a variety of errors. We compared the accuracy, precision and features of the six latest meters available in Australia as of 1996. Meters studied were the Mini-Accutrend and Advantage (Boehringer Mannheim), Precision QID and Companion 2 (MediSense), Glucometer Elite (Bayer) and Lynx (National Diagnostic Products). We measured the blood glucose levels of 50 people with diabetes with these meters, and compared them to a reference method (YSI glucose analyser). Error grid analysis confirmed that accuracy of all meters was sufficient for their intended use as patient monitors. Precision was assessed using 25 samples from control solutions provided for each meter, and the coefficient of variation calculated. Improvements in strip and meter technology in some models have increased ease of use and reduced the likelihood of user error. This study, when considered with individual preferences for various features and price should assist patients in choosing a new blood glucose meter.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of the present study was to investigate the efficacy of a memory and metamemory training program on memory performance and metamemory judgement accuracy in adults with a closed head injury. A multiple baseline across subjects design was used with six subjects. All subjects were seen at least two years post-injury. Training included general metamemory information about the nature of memory, use of a specific memory strategy to assist verbal recall (to Preview, Question, Read, State and Test- PQRST), specific metamemory information about the strategy, and a self instruction procedure (WTSC- What is the task, Select a strategy to use, Try out strategy, Check to evaluate strategy effectiveness). During the training period all subjects recalled greater than fifty percent of paragraph ideas while using PQRST. Follow-up tests showed that five of the six subjects maintained recall levels but a gradual decrease in slope was observed over eight weeks post-training. Tests of recall, recognition and metamemory judgements on Sentence and Action Tasks were used to evaluate generalisation of training. Two subjects showed improved recall and two subjects showed improved recognition performance. In addition, four subjects demonstrated greater metamemory judgement accuracy about recognition performance following training. Improved performance post-training was also observed for three subjects on the Rivermead Behavioral Memory Test and the Logical Memory subtest of the Wechsler Memory Scale-Revised, greater than that expected for repeated testing. Several factors were identified as having a role in subjects’ ability to benefit from training.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, we investigated the Langmuir film and Langmuir–Blodgett (LB) monolayer film of a nonionic amphiphilic molecule, 4-(6-p-pyridyloxyl)hexyloxyl-4′-dodecyloxylazobenzene (C12AzoC6Py) and its mixture with poly(d,l-lactide-co-glycolide) (PLG) at different subphase pH values (2.0, 2.6, 3.3, 4.4, and 6.5, respectively) by surface pressure–area (π–A) isotherms, in situ interface Brewster angle microscopy (BAM), and ex situ atomic force microscopy (AFM). For pure C12AzoC6Py, its π–A isotherms display a plateau when the subphase pH value is lower than 3.0. The pressure of the plateau increases with the decrease of pH until 2.0. Over the plateau, the π–A isotherms become almost identical to the one under neutral conditions. The appearance of such a plateau can be explained as the coexistence of protonation and unprotonation of pyridyl head groups of the employed amphiphile. In contrast to the homogeneous surface morphology of pure C12AzoC6Py near the plateau by BAM observation, the surface in the case of its mixing with PLG exhibits a dendritic crystalline state under low surface pressure at subphase pH lower than 3.0. The crystalline state becomes soft and gradually melts into homogeneous aggregates with surface pressure increasing to a higher value than that of the plateau. Meanwhile, the hydrolysis of PLG in the mixture system at the interface has been affirmed to be restrained to a very large extent. And the PLG was believed to be compelled to the up layer of the LB film due to the phase separation, which is examined by AFM. Based on the experimental results, the corresponding discussion was also performed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This research investigates whether club head speed is a valid determinant of golfing performance and the effects of a golf-specific warm-up program on club-head speed in male golfers in the immediate and short term (five-week)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The thesis found results supporting the involvement of the Right Frontal area of the brain in the subjective wellbeing (SWB) of individuals. Additional results suggested SWB is dependent upon Core Affect, itself dependent upon the Right Parietal area of the brain. These results provide evidence that SWB and Core Affect are based upon a neurological substrate. The portfolio investigated the association between chronic medical conditions and anxiety disorders, and how the occurence of anxiety issues can affect overall psychological adjustment to illness.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Deep brain stimulation has emerged as an effective method to treat certain medical conditions. Electrical charges are injected into the target tissue through a conducting electrode exciting the tissue. A variety of DBS devices have been developed based on different operation principles. Majority of these devices, however, employ complex circuitry and are bulky. In clinical trials, laboratory animals need to freely move around and perform activities whilst receiving brain stimulation for days. This paper presents a simple lightweight head mountable deep brain stimulation device that can be carried by the animal during the course of a clinical trial. The device produces continuous current pulses of specific characteristics. It employs passive charge balancing to minimize undesirable effects on the target tissue. The device is constructed and its performance tested.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: The Broberg and Morrey modification of the Mason classification of radial head fractures has substantial interobserver variation. This study used a large web-based collaborative of experienced orthopaedic surgeons to test the hypothesis that three-dimensional reconstructions of computed tomography (CT) scans improve the interobserver reliability of the classification of radial head fractures according to the Broberg and Morrey modification of the Mason classification.

Methods: Eighty-five orthopaedic surgeons evaluated twelve radial head fractures. They were randomly assigned to review either radiographs and two-dimensional CT scans or radiographs and three-dimensional CT images to determine the fracture classification, fracture characteristics, and treatment recommendations. The kappa multirater measure (κ) was calculated to estimate agreement between observers.

Results: Three-dimensional CT had moderate agreement and two-dimensional CT had fair agreement among observers for the Broberg and Morrey modification of the Mason classification, a difference that was significant. Observers assessed seven fracture characteristics, including fracture line, comminution, articular surface involvement, articular step or gap of ≥2 mm, central impaction, recognition of more than three fracture fragments, and fracture fragments too small to repair. There was a significant difference in kappa values between three-dimensional CT and two-dimensional CT for fracture fragments too small to repair, recognition of three fracture fragments, and central impaction. The difference between the other four fracture characteristics was not significant. Among treatment recommendations, there was fair agreement for both three-dimensional CT and two-dimensional CT.

Conclusions: Although three-dimensional CT led to some small but significant decreases in interobserver variation, there is still considerable disagreement regarding classification and characterization of radial head fractures. Three-dimensional CT may be insufficient to optimize interobserver agreement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents design and simulation of a circular meander dipole antenna at the industrial, scientific, and medical band of 915 MHz for energy scavenging in a passive head-mountable deep brain stimulation device. The interaction of the proposed antenna with a rat body is modeled and discussed. In the antenna, the radiating layer is meandered, and a FR-4 substrate is used to limit the radius and height of the antenna to 14 mm and 1.60 mm, respectively. The resonance frequency of the designed antenna is 915 MHz and the bandwidth of 15 MHz at a return loss of -10 dB in free space. To model the interaction of the antenna with a rat body, two aspects including functional and biological are considered. The functional aspect includes input impedance, resonance frequency, gain pattern, radiation efficiency of the antenna, and the biological aspect involves electric field distribution, and SAR value. A complete rat model is used in the finite difference time domain based EM simulation software XFdtd. The simulated results demonstrate that the specific absorption rate distributions occur within the skull in the rat model, and their values are higher than the standard regulated values for the antenna receiving power of 1W.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A circular planar inverted-F antenna (PIFA) is designed and simulated at the industrial, scientific, and medical (ISM) band of 915 MHz for energy harvesting in a head-mountable deep brain stimulation device. Moreover, a rectifier is designed, and also the interaction of the PIFA with a rat head model is investigated. In the proposed PIFA, the top radiating layer is meandered, and a substrate of FR-4 is used. The radius and the height of the antenna are 10 mm and 1.8 mm, respectively. The bottom conductive layer works as a ground plate, and a superstrate of polyethylene reduces the electromagnetic penetration into the rat head. The resonance frequency of the designed antenna is 915 MHz with a bandwidth of 18 MHz at the return loss of -10 dB in free space. The antenna parameters (e.g. reflection coefficient, gain, radiation efficiency), electric field distribution, and SAR value are evaluated within a seven-layer rat head model by using the finite difference time domain EM simulation software XFdtd. The interactions of the antenna and the rat head model are studied in both functional and biological aspects.