892 resultados para HVDC Multilevel Converters


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Multilevel algorithms are a successful class of optimisation techniques which address the mesh partitioning problem. They usually combine a graph contraction algorithm together with a local optimisation method which refines the partition at each graph level. To date these algorithms have been used almost exclusively to minimise the cut-edge weight, however it has been shown that for certain classes of solution algorithm, the convergence of the solver is strongly influenced by the subdomain aspect ratio. In this paper therefore, we modify the multilevel algorithms in order to optimise a cost function based on aspect ratio. Several variants of the algorithms are tested and shown to provide excellent results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract not available

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper examines the policy effects of multilevel regulation in Europe. It finds that the extent to which negative integration effectively narrows the range of policy options available domestically tends to be overstated. Drawing on empirical evidence from EU-induced reform in electricity supply and postal delivery, the paper illustrates that liberalisation and institutional reorganisation may lead to relatively little policy change. Although a lack of centralised regulatory capacity at the European level is identified as a key explanatory factor for the cases studied, the findings also point to the relevance of sector specificities and the role of exogenous drivers of change.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study examines the simultaneous effect of individual (selfefficacy) and group variables (cohesion and gender diversity) on satisfaction. A laboratory study was conducted involving 373 college students randomly distributed across 79 small groups, who performed a laboratory task in about five hours. Two-level Hierarchical Linear Modeling (HLM) method was used. Results show the main effect from individual selfefficacy to satisfaction (both level 1), the cross-level effect from group cohesion (level 2) to individual satisfaction (level 1), and the interaction effect between self-efficacy and gender diversity to satisfaction. These results suggest that in a work group, satisfaction has a background in individual and group variables. Group cohesion and gender diversity have important effects on satisfaction. The article concludes with practical strategies and with limitations and suggestions for future research.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Matrix power converters are used for transforming one alternating-current power supply to another, with different peak voltage and frequency. There are three input lines, with sinusoidally varying voltages which are 120◦ out of phase one from another, and the output is to be delivered as a similar three-phase supply. The matrix converter switches rapidly, to connect each output line in sequence to each of the input lines in an attempt to synthesize the prescribed output voltages. The switching is carried out at high frequency and it is of practical importance to know the frequency spectra of the output voltages and of the input and output currents. We determine in this paper these spectra using a new method, which has significant advantages over the prior default method (a multiple Fourier series technique), leading to a considerably more direct calculation. In particular, the determination of the input current spectrum is feasible here, whereas it would be a significantly more daunting procedure using the prior method instead.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Assessing the fit of a model is an important final step in any statistical analysis, but this is not straightforward when complex discrete response models are used. Cross validation and posterior predictions have been suggested as methods to aid model criticism. In this paper a comparison is made between four methods of model predictive assessment in the context of a three level logistic regression model for clinical mastitis in dairy cattle; cross validation, a prediction using the full posterior predictive distribution and two “mixed” predictive methods that incorporate higher level random effects simulated from the underlying model distribution. Cross validation is considered a gold standard method but is computationally intensive and thus a comparison is made between posterior predictive assessments and cross validation. The analyses revealed that mixed prediction methods produced results close to cross validation whilst the full posterior predictive assessment gave predictions that were over-optimistic (closer to the observed disease rates) compared with cross validation. A mixed prediction method that simulated random effects from both higher levels was best at identifying the outlying level two (farm-year) units of interest. It is concluded that this mixed prediction method, simulating random effects from both higher levels, is straightforward and may be of value in model criticism of multilevel logistic regression, a technique commonly used for animal health data with a hierarchical structure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Regulated Transformer Rectifier Units contain several power electronic boards to facilitate AC to DC power conversion. As these units become smaller, the number of devices on each board increases while their distance from each other decreases, making active cooling essential to maintaining reliable operation. Although it is widely accepted that liquid is a far superior heat transfer medium to air, the latter is still capable of yielding low device operating temperatures with proper heat sink and airflow design. The purpose of this study is to describe the models and methods used to design and build the thermal management system for one of the power electronic boards in a compact, high power regulated transformer rectifier unit. Maximum device temperature, available pressure drop and manufacturability were assessed when selecting the final design for testing. Once constructed, the thermal management system’s performance was experimentally verified at three different power levels.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Time-optimal response is an important and sometimes necessary characteristic of dynamic systems for specific applications. Power converters are widely used in different electrical systems and their dynamic response will affect the whole system. In many electrical systems like microgrids or voltage regulators which supplies sensitive loads fast dynamic response is a must. Minimum time is the fastest converter to compensate the step output reference or load change. Boost converters as one of the wildly used power converters in the electrical systems are aimed to be controlled in optimal time in this study. Linear controllers are not able to provide the optimal response for a boost converter however they are still useful and functional for other applications like reference tracking or stabilization. To obtain the fastest possible response from boost converters, a nonlinear control approach based on the total energy of the system is studied in this research. Total energy of the system considers as the basis for developing the presented method, since it is easy and accurate to measure besides that the total energy of the system represents the actual operating condition of the boost converter. The detailed model of a boost converter is simulated in MATLAB/Simulink to achieve the time optimal response of the boost converter by applying the developed method. The simulation results confirmed the ability of the presented method to secure the time optimal response of the boost converter under four different scenarios.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Lo studio intrapreso si è posto come obiettivo la caratterizzazione dal punto di vista elettrico dei materiali coinvolti nella realizzazione di accessori per applicazioni in HVDC, in particolare mescole isolanti, semiconduttive e varioresistive. La necessità di un lavoro di questo tipo viene giustificata dalla costante espansione dei sistemi in DC nella trasmissione dell’energia elettrica, i quali presentano caratteristiche fisiche che si differenziano sensibilmente da quelle tipiche dei tradizionali sistemi in AC, dunque richiedono componenti e materiali opportunamente progettati per garantire condizioni di servizio sicure e affidabili. L’obiettivo della trattazione consiste nello studio di analogie e differenze tra le proprietà elettriche fornite da prove su diverse configurazioni di provini, nella fattispecie di tipo piano e cilindrico cavo. In primo luogo si studiano i provini di tipo piano al fine di ricavare informazioni basilari sul materiale e sulla mescola che lo costituisce e di prendere decisioni relative al proseguimento dei test. Dopo aver effettuato un sufficiente numero di test su varie tipologie di provini piani e aver riconosciuto le mescole più performanti dal punto di vista elettrico, meccanico e termico, si procede alla realizzazione di provini cilindrici stampati, su cui si intraprendono le medesime misure effettuate per la configurazione piana. Questa seconda fase di caratterizzazione è fondamentale, in quanto consente di verificare che le proprietà già studiate su piastra si conservino in una geometria molto più simile a quella assunta dal prodotto finale evitando di sostenere costi onerosi per la produzione di un accessorio full-size. Il lavoro è stato svolto nel laboratorio elettrico di alta tensione della divisione R&D del gruppo Prysmian di Milano, leader mondiale nella produzione di sistemi in cavo per alte e altissime tensioni.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thesis (Master, Psychology) -- Queen's University, 2016-08-02 13:18:40.65

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The wave energy industry is entering a new phase of pre-commercial and commercial deployments of full-scale devices, so better understanding of seaway variability is critical to the successful operation of devices. The response of Wave Energy Converters to incident waves govern their operational performance and for many devices, this is highly dependent on spectral shape due to their resonant properties. Various methods of wave measurement are presented, along with analysis techniques and empirical models. Resource assessments, device performance predictions and monitoring of operational devices will often be based on summary statistics and assume a standard spectral shape such as Pierson-Moskowitz or JONSWAP. Furthermore, these are typically derived from the closest available wave data, frequently separated from the site on scales in the order of 1km. Therefore, variability of seaways from standard spectral shapes and spatial inconsistency between the measurement point and the device site will cause inaccuracies in the performance assessment. This thesis categorises time and frequency domain analysis techniques that can be used to identify changes in a sea state from record to record. Device specific issues such as dimensional scaling of sea states and power output are discussed along with potential differences that arise in estimated and actual output power of a WEC due to spectral shape variation. This is investigated using measured data from various phases of device development.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The paper presents an investigation of fix-referenced and self-referenced wave energy converters and a comparison of their corresponding wave energy conversion capacities from real seas. For conducting the comparisons, two popular wave energy converters, point absorber and oscillating water column, and their power conversion capacities in the fixed-referenced and self-referenced forms have been numerically studied and compared. In the numerical models, the deviceâ s power extractions from seas are maximized using the correspondingly optimized power take-offs in different sea states, thus their power conversion capacities can be calculated and compared. From the comparisons and analyses, it is shown that the energy conversion capacities of the self-referenced devices can be significantly increased if the motions of the device itself can be utilized for wave energy conversion; and the self-referenced devices can be possibly designed to be compliant in long waves, which could be a very beneficial factor for device survivability in the extreme wave conditions (normally long waves). In this regards, the self-referenced WECs (wave energy converters) may be better options in terms of wave energy conversion from the targeted waves in seas (frequently the most occurred), and in terms of the device survivability, especially in the extreme waves when compared to the fix-referenced counterparts.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An integrated mathematical model for the simulation of an offshore wind system performance is presented in this paper. The mathematical model considers an offshore variable-speed turbine in deep water equipped with a permanent magnet synchronous generator using multiple point full-power clamped three-level converter, converting the energy of a variable frequency source in injected energy into the electric network with constant frequency, through a HVDC transmission submarine cable. The mathematical model for the drive train is a concentrate two mass model which incorporates the dynamic for the blades of the wind turbine, tower and generator due to the need to emulate the effects of the wind and the floating motion. Controller strategy considered is a proportional integral one. Also, pulse width modulation using space vector modulation supplemented with sliding mode is used for trigger the transistors of the converter. Finally, a case study is presented to access the system performance.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

With the increasing of the distributed generation, DC microgrids have become more and more common in the electrical network. To connect devices in a microgrid, converter are necessary, but they are also source of disturbances due to their functioning. In this thesis, measurement and simulation of conducted emissions, within the frequency range 2-150kHz, of a DC/DC buck converter are studied.