886 resultados para Grafting.


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The compatibilizing effect of graft copolymer, linear low density polyethylene-g-polystyrene (LLDPE-g-PS), on immiscible LLDPE/PS blends has been studied by means of C-13 CP-MAS NMR and DSC techniques. The results indicate that LLDPE-g-PS is an effective compatibilizer for LLDPE/PS blends, and the compatibilizing effect of LLDPE-g-PS on LLDPE/PS blends depends on the PS grafting yield and molecular structure of the compatibilizers and also on the composition of the blends. It was found that LLDPE-g-PS chains connect two immiscible components, LLDPE and PS, through solubilization of chemically identical segments of LLDPE-g-PS into the noncrystalline region of the LLDPE and PS domain, respectively. Meanwhile, LLDPE-g-PS chains connect the crystalline region of LLDPE by isomorphism, resulting in an obvious change in the crystallization behavior of LLDPE. (C) 1996 John Wiley & Sons, Inc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A new amphiphilic polymer i.e., polyethylene glycol (PEG) grafted crystalline neoprene, which was used as compatibilizer to improve the compatibility of elastomer and water-absorbent resin, has been investigated. The synthesis was based on the reaction between chlorine in neoprene and sodium salts of PEG. PEGs with molecular weights of 600 and 2000 were used. The grafting percent and the PEG content were calculated through elemental analysis of chlorine in the resulted copolymers. The maximum grafting percent of copolymers was ca. 24.80%. The molecular parameters such as number-average molecular weight and the average number of grafting chains on one CR backbone were also calculated and discussed. (C) 1996 John Wiley & Sons, Inc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Possible changes in the structure and properties of maleated polyethylene (HDPE-MA) at different degrees of grafting (D.G.) were examined. At the level of 1.6 maleic anhydride (MA)/100 ethylene units E, 70-80% of crystallinity of the parent PE was retaine

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A new graft copolymer (PP-MA)-g-PEO was synthesized by means of the chemical reaction between maleated polypropylene (PP-MA) and mono hydroxyl poly(ethylene oxide) (PEO-OH). The effect of reaction conditions on the degree of grafting of PEO-OH was studied

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The structure of the radiation graft copolymer of acrylic acid onto EVA has been studied by infrared spectroscopy and XPS. It was found that along with the main peak C there is a photoelectron peak at 288.5 eV attributed to [GRAPHICS] group in XPS spectra and the content of its area in XPS increases with increasing of grafting degree of EVA. It was also found that hydrophilicity of EVA increases with the increase of grafting degree.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The porosity and the hydrophobicity of membranes are two essential requirements for membrane distillation (MD) of aqueous solutions. So far, the hydrophobic porous membranes used in MD studies have been prepared from hydrophobic materials. In this work, hydrophilic cellulose acetate and cellulose nitrate membranes were modified into hydrophobic membranes by radiation grafting polymerization and plasma polymerization, and used in MD studies successfully. The results indicated that modified membranes with good performance in MD can be obtained if the modifying conditions are controlled appropriately. Especially plasma polymerization, in which many particular kinds of monomer could be polymerized onto the surface of porous materials, has become an efficient method to prepare hydrophobic porous membrane with high performance from hydrophilic membranes. It will stimulate the development and practical application of MD.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Three different acyl thiourea derivatives of chitosan (CS) were synthesized and their structures were characterized by FT-IR spectroscopy and elemental analysis. The antimicrobial behaviors of CS and its derivatives against four species of bacteria (Escherichia coli, Pseudomonas aeruginosa, Staphylococcus aureus, and Sarcina) and four crop-threatening pathogenic fungi (Alternaria solani, Fusarium oxysporum f. sp. vasinfectum, Colletotrichum gloeosporioides (Penz.) Saec, and Phyllisticta zingiberi) were investigated. The results indicated that the antimicrobial activities of the acyl thiourea derivatives are much better than that of the parent CS. The minimum value of MIC and MBC of the derivatives against E coli was 15.62 and 62.49 mu g/mL, respectively. All of the acyl thiourea derivatives had a significant inhibitory effect on the fungi in concentrations of 50 - 500 mu g/mL; the maximum inhibitory index was 66.67%. The antifungal activities of the chloracetyl thiourea derivatives of CS are noticeably higher than the acetyl and benzoyl thiourea derivatives. The degree of grafting of the acyl thiourea group in the derivatives was related to antifungal activity; higher substitution resulted in stronger antifungal activity. (c) 2007 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

To explore the presence of depression, anxiety and cardiac events after coronary artery bypass grafting (CABG) prospectively and comparably. To analysis influential factors of depression and anxiety ( peri-operation and 1 year after operation ), and the effection on cardiac events in the year after operation. We followed the patients who underwent scheduled consecutive CABG. We interviewed patients to assess depression, anxiety symptoms using self-rating depression scale( SDS) and self-rating anxiety scale(SAS)before operation , before discharge and 1 year after operation. And cardiac events were also identified. All patients were divided into the group with depression and/or anxiety symptoms or the other group without depression and/or anxiety symptoms 3 times according to depression and anxiety symptoms before operation , before discharge and 1 year after operation. 69 patients completed the follow-up.24 patients (34.8%) had depression and/or anxiety symptoms before CABG, 31 patients (44.9%) had depression and/or anxiety symptoms before discharge, and 10 patients (14.5%) had depression and/or anxiety symptoms 1 year after operation. 6 patients(8.7%) had cardiac events, and 5 patients were re-admitted. Arhythmia before and after operation, the quantity of blood vessel grafted, length of stay , depression and anxiety symptoms before operation, cardiac events may lead to depression and anxiety symptoms 1 year after operation. The use of cardiopulmonary bypass grafting (CPB), Arhythmia after operation, the prolonged length of stay are influential factors of cardiac events. Though the incidence of depression and/or anxiety symptoms 1 year after operation is lower than before operation and before discharge, it is high still. Arhythmia before and after operation, the more blood vessels grafted, the prolonged length of stay , depression and anxiety symptoms before operation and cardiac events could be risk factors of depression and anxiety symptoms 1 year after operation. Much attention must be paid to this phenomenon. Heavy patient's condition, complicated surgery are risk factors of cardiac events, and bad emotion before operation and before discharge are independent to cardiac events. Key words: perspective research; depression;anxiety; coronary artery bypass grafting; follow up

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A enxertia e um processo de multiplicacao vegetativa muito usado para especies frutiferas. Embora seja amplamente difundida e utilizada para laranja, a maioria dos citricultores do estado do Amazonas nao tem total dominio dessa tecnica.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Copper nanoparticles were deposited onto mesoporous SBA-15 support via two different routes: post-grafting method and incipient wet impregnation method. Both XRD and TEM reveal that the post-grafting can make Cu particles very small in size and highly dispersed into channels of SBA-15, while the impregnation method mainly forms large Cu particles on the external surface of SBA-15. TPR experiments show that CuO species formed by the post-grafting method is more reducible than that prepared by the impregnation method. The catalytic activity tests for CO oxidation manifests that the sample prepared by the post-grafting method has a much higher activity than that prepared by the impregnation method, with a lowering of 50 degrees C for T-50, showing a strong dependence of catalytic activity on the size and dispersion of Cu particles. Besides the preparation procedure, other factors including calcination temperature, reduction treatment, copper loading as well as the feed composition, have an important effect on the catalytic activity. The best performance was obtained when the catalyst was calcined at 500 degrees C and reduced at 550 degrees C. The calcination and reduction treatment at high temperature have been found to be necessary to completely remove the organic residue and to generate active metallic copper particles. (c) 2005 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Despite numerous studies on endotracheal tube cuff pressure (CP) management, the literature has yet to establish a technique capable of adequately tilling the cuff with an appropriate volume of air while generating low CP in a less subjective way. the purpose of this prospective study was to evaluate and compare the CP levels and air volume required to fill the endotracheal tubes cuff using 2 different techniques (volume-time curve versus minimal occlusive volume) in the immediate postoperative period after coronary artery bypass grafting. METHODS: A total of 267 subjects were analyzed. After the surgery, the lungs were ventilated using pressure controlled continuous mandatory ventilation, and the same ventilatory parameters were adjusted. Upon arrival in the ICU, the cuff was completely deflated and re-inflated, and at this point the volume of air to fill the cuff was adjusted using one of 2 randomly selected techniques: volume-time curve and minimal occlusive volume. We measured the volume of air injected into the cuff, the CP, and the expired tidal volume of the mechanical ventilation after the application of each technique. RESULTS: the volume-time curve technique demonstrated a significantly lower CP and a lower volume of air injected into the cuff, compared to the minimal occlusive volume technique (P < .001). No significant difference was observed in the expired tidal volume between the 2 techniques (P = .052). However, when the subjects were submitted to the minimal occlusive volume technique, 17% (n = 47) experienced air leakage as observed by the volume-time graph. CONCLUSIONS: the volume-time curve technique was associated with a lower CP and a lower volume of air injected into the cuff, when compared to the minimal occlusive volume technique in the immediate postoperative period after coronary artery bypass grafting. Therefore, the volume-time curve may be a more reliable alternative for endotracheal tube cuff management.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Previous investigation showed that the volume-time curve technique could be an alternative for endotracheal tube (ETT) cuff management. However, the clinical impact of the volume-time curve application has not been documented. the purpose of this study was to compare the occurrence and intensity of a sore throat, cough, thoracic pain, and pulmonary function between these 2 techniques for ETT cuff management: volume-time curve technique versus minimal occlusive volume (MOV) technique after coronary artery bypass grafting. METHODS: A total of 450 subjects were randomized into 2 groups for cuff management after intubation: MOV group (n = 222) and volume-time curve group (n = 228). We measured cuff pressure before extubation. We performed spirometry 24 h before and after surgery. We graded sore throat and cough according to a 4-point scale at 1, 24, 72, and 120 h after extubation and assessed thoracic pain at 24 h after extubation and quantified the level of pain by a 10-point scale. RESULTS: the volume-time curve group presented significantly lower cuff pressure (30.9 +/- 2.8 vs 37.7 +/- 3.4 cm H2O), less incidence and intensity of sore throat (1 h, 23.7 vs 51.4%; and 24 h, 18.9 vs 40.5%, P < .001), cough (1 h, 19.3 vs 48.6%; and 24 h, 18.4 vs 42.3%, P < .001), thoracic pain (5.2 +/- 1.8 vs 7.1 +/- 1.7), better preservation of FVC (49.5 +/- 9.9 vs 41.8 +/- 12.9%, P = .005), and FEV1, (46.6 +/- 1.8 vs 38.6 +/- 1.4%, P = .005) compared with the MOV group. CONCLUSIONS: the subjects who received the volume-time curve technique for ETT cuff management presented a significantly lower incidence and severity of sore throat and cough, less thoracic pain, and minimally impaired pulmonary function than those subjects who received the MOV technique during the first 24 h after coronary artery bypass grafting.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Projeto de Pós-Graduação/Dissertação apresentado à Universidade Fernando Pessoa como parte dos requisitos para obtenção do grau de Mestre em Medicina Dentária

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Projeto de Pós-Graduação/Dissertação apresentado à Universidade Fernando Pessoa como parte dos requisitos para obtenção do grau de Mestre em Medicina Dentária

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Surface modification of silicon with organic monolayers tethered to the surface by different linkers is an important process in realizing future (opto-)electronic devices. Understanding the role played by the nature of the linking group and the chain length on the adsorption structures and electronic properties of these assemblies is vital to advance this technology. This Thesis is a study of such properties and contributes in particular to a microscopic understanding of induced changes in the work function of experimentally studied functionalized silicon surfaces. Using first-principles density functional theory (DFT), at the first step, we provide predictions for chemical trends in the work function of hydrogenated silicon (111) surfaces modified with various terminations. For nonpolar terminating atomic species such as F, Cl, Br, and I, the change in the work function is directly proportional to the amount of charge transferred from the surface, thus relating to the difference in electronegativity of the adsorbate and silicon atoms. The change is a monotonic function of coverage in this case, and the work function increases with increasing electronegativity. Polar species such as −TeH, −SeH, −SH, −OH, −NH2, −CH3, and −BH2 do not follow this trend due to the interaction of their dipole with the induced electric field at the surface. In this case, the magnitude and sign of the surface dipole moment need to be considered in addition to the bond dipole to generally describe the change in work function. Compared to hydrogenated surfaces, there is slight increase in the work function of H:Si(111)-XH, where X = Te, Se, and S, whereas reduction is observed for surfaces covered with −OH, −CH3, and −NH2. Next, we study the hydrogen passivated Si(111) surface modified with alkyl chains of the general formula H:Si–(CH2)n–CH2 and H:Si–X–(CH2)n–CH3, where X = NH, O, S and n = (0, 1, 3, 5, 7, 9, 11), at half coverage. For (X)–Hexyl and (X)–Dodecyl functionalization, we also examined various coverages up to full monolayer grafting in order to validate the result of half covered surface and the linker effect on the coverage. We find that it is necessary to take into account the van der Waals interaction between the alkyl chains. The strongest binding is for the oxygen linker, followed by S, N, and C, irrespective of chain length. The result revealed that the sequence of the stability is independent of coverage; however, linkers other than carbon can shift the optimum coverage considerably and allow further packing density. For all linkers apart from sulfur, structural properties, in particular, surface-linker-chain angles, saturate to a single value once n > 3. For sulfur, we identify three regimes, namely, n = 0–3, n = 5–7, and n = 9–11, each with its own characteristic adsorption structures. Where possible, our computational results are shown to be consistent with the available experimental data and show how the fundamental structural properties of modified Si surfaces can be controlled by the choice of linking group and chain length. Later we continue by examining the work function tuning of H:Si(111) over a range of 1.73 eV through adsorption of alkyl monolayers with general formula -[Xhead-group]-(CnH2n)-[Xtail-group], X = O(H), S(H), NH(2). The work function is practically converged at 4 carbons (8 for oxygen), for head-group functionalization. For tail-group functionalization and with both head- and tail-groups, there is an odd-even effect in the behavior of the work function, with peak-to-peak amplitudes of up to 1.7 eV in the oscillations. This behavior is explained through the orientation of the terminal-group's dipole. The shift in the work function is largest for NH2-linked and smallest for SH-linked chains and is rationalized in terms of interface dipoles. Our study reveals that the choice of the head- and/or tail-groups effectively changes the impact of the alkyl chain length on the work function tuning using self-assembled monolayers and this is an important advance in utilizing hybrid functionalized Si surfaces. Bringing together the understanding gained from studying single type functionalization of H:Si(111) with different alkyl chains and bearing in mind how to utilize head-group, tail-group or both as well as monolayer coverage, in the final part of this Thesis we study functionalized H:Si(111) with binary SAMs. Aiming at enhancing work function adjustment together with SAM stability and coverage we choose a range of terminations and linker-chains denoted as –X–(Alkyl) with X = CH3, O(H), S(H), NH(2) and investigate the stability and work function of various binary components grafted onto H:Si(111) surface. Using binary functionalization with -[NH(2)/O(H)/S(H)]-[Hexyl/Dodecyl] we show that work function can be tuned within the interval of 3.65-4.94 eV and furthermore, enhance the SAM’s stability. Although direct Si-C grafted SAMs are less favourable compared to their counterparts with O, N or S linkage, regardless of the ratio, binary functionalized alkyl monolayers with X-alkyl (X = NH, O) is always more stable than single type alkyl functionalization with the same coverage. Our results indicate that it is possible to go beyond the optimum coverage of pure alkyl functionalized SAMs (50%) by adding a linker with the correct choice of the linker. This is very important since dense packed monolayers have fewer defects and deliver higher efficiency. Our results indicate that binary anchoring can modify the charge injection and therefore bond stability while preserving the interface electronic structure.