990 resultados para Gingival prosthesis


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conventional tilted implants are used in oral rehabilitation for heavily absorbed maxilla to avoid bone grafts; however, few research studies evaluate the biomechanical behavior when different angulations of the implants are used. The aim of this study was evaluate, trough photoelastic method, two different angulations and length of the cantilever in fixed implant-supported maxillary complete dentures. Two groups were evaluated: G15 (distal tilted implants 15°) and G35 (distal tilted implants 35°) n = 6. For each model, 2 distal tilted implants (3.5 x 15 mm long cylindrical cone) and 2 parallel tilted implants in the anterior region (3.5 x 10 mm) were installed. Photoelastic models were submitted to three vertical load tests: in the end of cantilever, in the last pillar and in the all pillars at the same time. We obtained the shear stress by Fringes software and found values for total, cervical and apical stress. The quantitative analysis was performed using the Student tests and Mann-Whitney test; p ≥ 0.05. There is no difference between G15 and G35 for total stress regardless of load type. Analyzing the apical region, G35 reduced strain values considering the distal loads (in the cantilever p = 0.03 and in the last pillar p = 0.02), without increasing the stress level in the cervical region. Considering the load in all pillars, G35 showed higher stress concentration in the cervical region (p = 0.04). For distal loads, G15 showed increase of tension in the apical region, while for load in all pillars, G35 inclination increases stress values in the cervical region.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The present study investigated the effectiveness of mesenchymal stem cells (MSCs) associated with a fibrin scaffold (FS) for the peripheral regenerative process after nerve tubulization. Adult female Lewis rats received a unilateral sciatic nerve transection followed by repair with a polycaprolactone (PCL)-based tubular prosthesis. Sixty days after injury, the regenerated nerves were studied by immunohistochemistry. Anti-p75NTR immunostaining was used to investigate the reactivity of the MSCs. Basal labeling, which was upregulated during the regenerative process, was detected in uninjured nerves and was significantly greater in the MSC-treated group. The presence of GFP-positive MSCs was detected in the nerves, indicating the long term survival of such cells. Moreover, there was co-localization between MSCs and BNDF immunoreactivity, showing a possible mechanism by which MSCs improve the reactivity of SCs. Myelinated axon counting and morphometric analyses showed that MSC engrafting led to a higher degree of fiber compaction combined with a trend of increased myelin sheath thickness, when compared with other groups. The functional result of MSC engrafting was that the animals showed higher motor function recovery at the seventh and eighth week after lesion. The findings herein show that MSC+FS therapy improves the nerve regeneration process by positively modulating the reactivity of SCs.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Facial trauma can be considered one of the most serious aggressions found in the medical centers due to the emotional consequences and the possibility of deformity. In craniofacial surgery, the use of autologous bone is still the first choice for reconstructing bony defects or irregularities. When there is a shortage of donor bone or a patient refuses an intracranial operation, alloplastic materials such as polymethylmethacrylate (PMMA) can be used. The PMMA prosthesis can be pre-fabricated, bringing advantages such as reduction of surgical time, easy technical handling and good esthetic results. This paper describes the procedures for rehabilitating a patient with PMMA implants in the region of the face, recovering the facial contours and esthetics of the patient.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

INTRODUÇãO: os cirurgiões-dentistas têm a responsabilidade de prevenir doenças, minimizar riscos e promover saúde. Os pacientes também precisam ser despertados sobre o seu papel nos cuidados com a saúde bucal. No caso de pacientes em tratamento ortodôntico, é particularmente difícil manter uma higiene bucal satisfatória devido à presença de bandas, fios e ligaduras. Torna-se, então, indispensável a instituição de métodos preventivos de motivação e orientação para o controle mecânico da placa dentária. OBJETIVO: verificar os efeitos de ações educativas, preventivas e motivacionais sobre a saúde bucal de pacientes em tratamento ortodôntico fixo. MéTODOS: os participantes receberam gratuitamente dentifrício e escova dental durante todo o estudo e instruções sobre higiene bucal foram fornecidas e reforçadas no decorrer dos 6 meses da pesquisa. Foram realizados exames clínicos baseline e após 6, 12 e 24 semanas, para verificação dos índices de Placa, Gengival e Sangramento. RESULTADOS: as condições de saúde bucal dos participantes, que inicialmente eram insatisfatórias, melhoraram significativamente no decorrer do estudo, considerando-se todos os índices. As ações preventivas, educativas e motivacionais realizadas foram estatisticamente eficazes na melhora da saúde bucal dos pacientes ortodônticos. CONCLUSõES: a promoção de saúde e a prevenção de doenças devem fazer parte do atendimento que os ortodontistas direcionam aos seus pacientes, sendo que a orientação e motivação quanto aos cuidados com a saúde bucal devem estar presentes antes e durante o tratamento.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

INTRODUÇÃO: apesar da colagem direta despender menor tempo clínico, com maior preservação da integridade gengival, ainda hoje se observa uma alta incidência de bandagem dos molares. Portanto, torna-se interessante a idealização de recursos para o aumento da eficiência desse procedimento para dentes submetidos a maiores impactos mastigatórios, como, por exemplo, os molares. OBJETIVO: esse estudo teve o propósito de avaliar se a resistência à adesão com a aplicação de uma camada de resina adicional na região oclusal da interface tubo/dente aumenta a qualidade do procedimento de colagem direta de tubos em molares. MÉTODOS: selecionou-se uma amostra composta por 40 terceiros molares inferiores, que foram aleatoriamente divididos em 2 grupos: Grupo 1 - colagem direta convencional, seguida pela aplicação de uma camada de resina na oclusal da interface tubo/dente; e Grupo 2 - colagem direta convencional. O teste de resistência ao cisalhamento foi realizado 24 horas após a colagem, utilizando-se uma máquina de ensaio universal, operando a uma velocidade de 0,5mm/min. Os resultados foram analisados por meio do teste t independente. RESULTADOS: os valores médios obtidos nos testes de cisalhamento foram: 17,08MPa para o Grupo 1 e 12,60MPa para o Grupo 2. O Grupo 1 apresentou uma resistência ao cisalhamento estatisticamente significativa mais alta do que o Grupo 2. CONCLUSÃO: a aplicação de uma camada adicional de resina na oclusal da interface tubo/dente aumenta a qualidade da adesão do procedimento de colagem direta de tubos ortodônticos em molares.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Craniosynostosis syndromes are characterized by premature closure of one or more cranial sutures, associated with other malformations, the most frequent of which are the Crouzon and Apert syndromes. Few studies in the literature have addressed the oral health of these individuals. The purpose of this study was to compare the periodontal status of individuals with Apert, Crouzon, Pfeiffer and Saethre-Chotzen syndromes before toothbrushing and compare the efficiency of plaque removal before and after mechanical toothbrushing. The probing depth, plaque index (according to Löe and O'Leary), clinical attachment level, gingival index (according to Silness and Löe) and amount of keratinized mucosa were evaluated before toothbrushing, and the O'Leary plaque index was assessed before and immediately after toothbrushing, on the same day, in 27 individuals aged 11 to 36 years. There was statistically significant difference in the mean probing depth and clinical attachment level among regions (p=0.00; p=0.01, respectively). The gingival index did not reveal statistically significant differences. With regard to the plaque index, the left region exhibited higher plaque index values than the right and anterior regions. No significant results were found in the analysis of keratinized mucosa. Comparison of the O'Leary plaque index before and after toothbrushing revealed statistically significant difference for all syndromes except for the Pfeiffer syndrome (p<0.05). In conclusion, there was no difference in the periodontal status among individuals with syndromic craniosynostosis. The posterior region was more affected than the anterior region as to the presence of plaque, loss of insertion and probing depth. Individuals with Pfeiffer syndrome exhibited greater toothbrushing efficiency than individuals with the other craniosynostosis syndromes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In long-term oral rehabilitation treatments, resistance of provisional crowns is a very important factor, especially in cases of an extensive edentulous distal space. The aim of this laboratorial study was to evaluate an acrylic resin cantilever-type prosthesis regarding the flexural strength of its in-balance portion as a function of its extension variation and reinforcement by two types of fibers (glass and polyaramid), considering that literature is not conclusive on this subject. Each specimen was composed by 3 total crowns at its mesial portion, each one attached to an implant component (abutment), while the distal portion (cantilever) had two crowns. Each specimen was constructed by injecting acrylic resin into a two-part silicone matrix placed on a metallic base. In each specimen, the crowns were fabricated with either acrylic resin (control group) or acrylic resin reinforced by glass (Fibrante, Angelus) or polyaramide (Kevlar 49, Du Pont) fibers. Compression load was applied on the cantilever, in a point located 7, 14 or 21 mm from the distal surface of the nearest crown with abutment, to simulate different extensions. The specimen was fixed on the metallic base and the force was applied until fracture in a universal test machine. Each one of the 9 sub-groups was composed by 10 specimens. Flexural strength means (in kgf) for the distances of 7, 14 and 21 mm were, respectively, 28.07, 8.27 and 6.39 for control group, 31.89, 9.18 and 5.16 for Kevlar 49 and 30.90, 9.31 and 6.86 for Fibrante. Data analysis ANOVA showed statistically significant difference (p<0.05) only regarding cantilever extension. Tukey's test detected significantly higher flexural strength for the 7 mm-distance, followed by 14 and 21 mm. Fracture was complete only on specimens of non-reinforced groups.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dental impression is an important step in the preparation of prostheses since it provides the reproduction of anatomic and surface details of teeth and adjacent structures. The objective of this study was to evaluate the linear dimensional alterations in gypsum dies obtained with different elastomeric materials, using a resin coping impression technique with individual shells. A master cast made of stainless steel with fixed prosthesis characteristics with two prepared abutment teeth was used to obtain the impressions. References points (A, B, C, D, E and F) were recorded on the occlusal and buccal surfaces of abutments to register the distances. The impressions were obtained using the following materials: polyether, mercaptan-polysulfide, addition silicone, and condensation silicone. The transfer impressions were made with custom trays and an irreversible hydrocolloid material and were poured with type IV gypsum. The distances between identified points in gypsum dies were measured using an optical microscope and the results were statistically analyzed by ANOVA (p < 0.05) and Tukey's test. The mean of the distances were registered as follows: addition silicone (AB = 13.6 µm, CD=15.0 µm, EF = 14.6 µm, GH=15.2 µm), mercaptan-polysulfide (AB = 36.0 µm, CD = 36.0 µm, EF = 39.6 µm, GH = 40.6 µm), polyether (AB = 35.2 µm, CD = 35.6 µm, EF = 39.4 µm, GH = 41.4 µm) and condensation silicone (AB = 69.2 µm, CD = 71.0 µm, EF = 80.6 µm, GH = 81.2 µm). All of the measurements found in gypsum dies were compared to those of a master cast. The results demonstrated that the addition silicone provides the best stability of the compounds tested, followed by polyether, polysulfide and condensation silicone. No statistical differences were obtained between polyether and mercaptan-polysulfide materials.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

TEMA: a produção da fala nas modalidades de reabilitação oral protética. OBJETIVO: verificar se o tipo de reabilitação oral interfere na produção da fala. MÉTODO: 36 idosos (média = 68 anos), divididos em 3 grupos, foram avaliados: 13 com dentes naturais (A), 13 com prótese total mucosossuportada superior e inferior (B) e 10 com prótese total mucosossuportada superior e implantossuportada inferior (C). A estabilidade das próteses foi avaliada por um dentista e amostras de fala foram analisadas por 5 fonoaudiólogos. Para determinar a freqüência de alteração dos sons da fala utilizou-se o cálculo da Porcentagem de Consoantes Corretas (PCC). RESULTADOS: observou-se poucos casos com alteração de fala, com maior freqüência no grupo C (23,08%), sendo a articulação travada presente em todos os grupos, a redução dos movimentos labiais em dois grupos (A e B) e a articulação exagerada e a falta de controle salivar em um dos grupos (C e B). Quanto à PCC, menor valor foi observado para os fones linguodentais nos grupos B e C (maior ocorrência de alteração), seguido dos fones alveolares, predominando casos sem alteração no grupo A, contrariamente aos demais grupos, sendo a projeção lingual e o ceceio as alterações mais encontradas. Não houve diferença entre os grupos e a maioria do grupo B estava com a prótese inferior insatisfatória, não havendo associação entre alteração de fala e prótese insatisfatória. CONCLUSÃO: apesar da amostra pequena, indivíduos reabilitados com prótese total apresentam alteração nos fones linguodentais e alveolares e o tipo de prótese, bem como a estabilidade desta parece não interferir na produção da fala.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJETIVO: Apresentar as características clínicas, tratamento cirúrgico e achado histológico de um caso de lipoidoproteinose. DESCRIÇÃO DO CASO: Criança do sexo masculino, cinco anos de idade, branco, que procurou atendimento odontológico na Universidade. A mãe da criança relatou presença de intensa halitose e dificuldade na alimentação e higienização bucal, decorrentes de crescimento gengival generalizado nos arcos dentários superior e inferior. No exame clínico, verificaram-se comprometimento funcional e estético generalizado (rouquidão, artralgia bilateral no joelho e tornozelo, lesões tumorais nas orelhas, entre outros), além de extensa hiperplasia gengival em ambos os arcos dentários. Optou-se pelo tratamento cirúrgico, com remoção do tecido hiperplásico e exodontia de todos os dentes decíduos e de dois permanentes. O exame histopatológico da peça cirúrgica confirmou o diagnóstico de lipoidoproteinose. COMENTÁRIOS: A lipoidoproteinose é uma doença rara caracterizada pela deposição da substância hialina na pele, membranas mucosas e nos órgãos internos. Os sinais que podem surgir após o nascimento, são: rouquidão; lesões pápulo-nodulares na cabeça, pescoço e membros; lesões papulares amareladas nas margens das pálpebras. O curso desta doença é benigno e crônico.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The prosthetic rehabilitation of an atrophic mandible is usually unsatisfactory due to the lack of support tissues, mainly bone and keratinized mucosa for treatment with osseointegrated implants or even conventional prosthesis. The prosthetic instability leads to social and functional limitations and chronic physical trauma decreasing the patient's quality of life. A 53-year-old female patient sought care at our surgical service complaining of impairment of her masticatory function associated with the instability of the lower total prosthetic denture. The clinical and complementary exams revealed edentulism in both arches, while the mandibular arch presented severe reabsorption resulting in denture instability and chronic trauma to the oral mucosa. The proposed treatment plan consisted in the mandibular rehabilitation with osseointegrated implants and fixed Brånemark's protocol prosthesis after mandibular reconstruction applying the modified visor osteotomy technique. The proposed technique offered predictable results for reconstruction of the severely resorbed edentulous mandible and posterior rehabilitation with osseointegrated implants.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study analyzed the association of periodontal disease (PD) and rheumatoid arthritis (RA). Seventy-five 35-60-year-old patients were assigned to 5 groups according to the presence (+) or not (-) of PD and RA and the treatment received (TR+) or not (TR-) for PD. Group 3 uses total prosthesis (TP). Clinical and laboratory evaluations were performed at baseline, 3 and 6 months of follow-up by probing pocket depth, bleeding on probing and plaque index for PD, HAQ, DAS28, SF-36 and laboratory: AAG, ESR, CRP for RA. Statistically significant differences for PD after 3 (p=0.0055) and after 6 months (p=0.0066) were obtained in Group 1 (RA+PD+TR+) and 2(RA+PD+TR-); significant reduction in the % of BOP after 6 months (p=0.0128) and significant reduction in the % of Pl after 3 (p=0.0128) and 6 months (p=0.0002) in Group 1. Statistically significant differences between Groups 1 and 3 (RA+TP) for DAS28 at baseline and after 3 months were observed, but not after 6 months. No other parameters for RA were significantly affected. The relationship between RA and PD disease activities is not clear, but the importance of periodontal treatment in the control of inflammation to avoid tooth extraction is evident.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

One of the most important properties of artificial teeth is the abrasion wear resistance, which is determinant in the maintenance of the rehabilitation's occlusal pattern. OBJECTIVES: This in vitro study aims to evaluate the abrasion wear resistance of 7 brands of artificial teeth opposed to two types of antagonists. MATERIAL AND METHODS: Seven groups were prepared with 12 specimens each (BIOLUX & BL, TRILUX & TR, BLUE DENT & BD, BIOCLER & BC, POSTARIS & PO, ORTHOSIT & OR, GNATHOSTAR & GN), opposed to metallic (M & nickel-chromium alloy), and to composite antagonists (C & Solidex indirect composite). A mechanical loading device was used (240 cycles/min, 4 Hz speed, 10 mm antagonist course). Initial and final contours of each specimen were registered with aid of a profile projector (20x magnification). The linear difference between the two profiles was measured and the registered values were subjected to ANOVA and Tukey's test. RESULTS: Regarding the antagonists, only OR (M = 10.45 ± 1.42 µm and C = 2.77 ± 0.69 µm) and BC (M = 6.70 ± 1.37 µm and C = 4.48 ± 0.80 µm) presented statistically significant differences (p < 0.05). Best results were obtained with PO (C = 2.33 ± 0.91 µm and M = 1.78 ± 0.42 µm), followed by BL (C = 3.70 ± 1.32 µm and M = 3.70 ± 0.61 µm), statistically similar for both antagonists (p>0.05). Greater result variance was obtained with OR, which presented the worse results opposed to Ni-Cr (10.45 ± 1.42 µm), and results similar to the best ones against composite (2.77 ± 0.69 µm). CONCLUSIONS: Within the limitations of this study, it may be concluded that the antagonist material is a factor of major importance to be considered in the choice of the artificial teeth to be used in the prosthesis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study analyzed the reaction layer and measured the marginal crown fit of cast titanium applied to different phosphate-bonded investments, prepared under the following conditions (liquid concentration/casting temperature): Rema Exakt (RE) - 100%/237°C, 75%/287°C, Castorit Super C (CS)-100%/70°C, 75%/141°C and Rematitan Plus (RP)- 100%/430°C (special to titanium cast, as the control group). The reaction layer was studied using the Vickers hardness test, and analyzed by two way ANOVA and Tukey's HSD tests (α = 0.05). Digital photographs were taken of the crowns seated on the die, the misfit was measured using an image analysis system and One-way ANOVA, and Tukey's test was applied (α = 0.05). The hardness decreased from the surface (601.17 VHN) to 150 μm (204.03 VHN). The group CS 75%/141°C presented higher hardness than the other groups, revealing higher surface contamination, but there were no differences among the groups at measurements deeper than 150 μm. The castings made with CS - 100%/70°C presented the lowest levels of marginal misfit, followed by RE -100%/237°C. The conventional investments CS (100%) and RE (100%) showed better marginal fit than RP, but the CS (75%) had higher surface contamination.