1000 resultados para Gamma-globin


Relevância:

20.00% 20.00%

Publicador:

Resumo:

info:eu-repo/semantics/nonPublished

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The screening and treatment of latent tuberculosis (TB) infection reduces the risk of progression to active disease and is currently recommended for HIV-infected patients. The aim of this study is to evaluate, in a low TB incidence setting, the potential contribution of an interferon-gamma release assay in response to the mycobacterial latency antigen Heparin-Binding Haemagglutinin (HBHA-IGRA), to the detection of Mycobacterium tuberculosis infection in HIV-infected patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tuberculosis-associated immune reconstitution inflammatory syndrome (TB-IRIS) remains a poorly understood complication in HIV-TB patients receiving antiretroviral therapy (ART). TB-IRIS could be associated with an exaggerated immune response to TB-antigens. We compared the recovery of IFNγ responses to recall and TB-antigens and explored in vitro innate cytokine production in TB-IRIS patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Motivated by the Minimal Dark Matter scenario, we consider the annihilation into gamma rays of candidates in the fermionic 5-plet and scalar 7-plet representations of SU(2)L, taking into account both the Sommerfeld effect and the internal bremsstrahlung. Assuming the Einasto profile, we show that present measurements of the Galactic Center by the H.E.S.S. instrument exclude the 5-plet and 7-plet as the dominant form of dark matter for masses between 1 TeV and 20 TeV, in particular, the 5-plet mass leading to the observed dark matter density via thermal freeze-out. We also discuss prospects for the upcoming Cherenkov Telescope Array, which will be able to probe even heavier dark matter masses, including the scenario where the scalar 7-plet is thermally produced.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work combines microscopy, synchrotron radiation X-ray diffraction, differential scanning calorimetry and thermodynamic calculations in the characterisation of phase transformation behaviour of a Ti–46Al–1.9Cr–3Nb alloy upon continuous heating at constant rates. It has been found that the Ti–46Al–1.9Cr–3Nb alloy after being forged at 1200 °C without further treatment has a duplex microstructure consisting of fine equiaxed and lamellar ? grains with a small amount of a2 plates and particles and about 1 wt.% B2 phase. Differential scanning calorimetry revealed reproducibly several thermal effects upon heating of the as-forged alloy. These thermal effects are related to the equilibration and homogenisation of the sample, change of phase ratios between a2, ? and B2 phases in particular the increase of B2 in respect to a2 and ?, and the following five phase transformations: a2 + ? + B2 a + ? + B2, a + ? + B2 a + ?, ? + a a, a a + ß, a + ß a + ß + L. The observation of these transformations by differential scanning calorimetry is largely in agreement with literature phase diagrams and thermodynamic calculations, though care is needed to consider the different alloy compositions. Kinetics of the ? + a a phase transformation in the Ti–46Al–1.9Cr–3Nb alloy has been quantitatively derived from the calorimetry data, giving phase compositions at any point during the transformation upon continuous heating.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ultra-high molecular weight polyethylene (UHMWPE) is used for wear applications in total hip prostheses and total knee prostheses. Sterilisation of these prostheses is commonly by gamma-irradiation. This process creates reactive free radicals in the UHMWPE, greatly increasing its susceptibility to oxidative degradation. This study has investigated the influence of air and vacuum packaging on the properties of gamma-irradiated UHMWPE (GUR1050) following 3 years of shelf ageing. The findings indicate that vacuum packaging minimises oxidative degradation reactions that occur for UHMWPE during shelf ageing. However, gamma-irradiation of vacuum-packaged UHMWPE promotes a degree of cross-linking. It is proposed that this may enhance the wear performance of UHMWPE. Accelerated ageing studies indicate that 3 years of shelf ageing would also seem to reduce the susceptibility of gamma-irradiated UHMWPE to oxidative degradation upon removal from its vacuum packaging.