965 resultados para GRAFT FIXATION
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Moderate and controlled loading environments support or enhance osteogenesis, and, consequently, a high degree of bone-to-implant contact can be acquired. This is because when osteoprogenitor cells are exposed to limited physical deformation, their differentiation into osteoblasts is enhanced. Then, some range of microstrain is considered advantageous for bone ingrowth and osseointegration. The primary stability has been considered one of the main clinical means of controlling micromotion between the implant and the forming interfacial tissue, which helps to establish the proper mechanical environment for osteogenesis. Based on the biological aspects of immediate loading (IL), the objective of this study is to present a clinical case of maxillary arch rehabilitation using immediate loading with implant-supported fixed restoration after bone graft. Ten dental implants were placed in the maxilla 6 months after the autogenous bone graft, removed from the mandible (bilateral oblique line and chin), followed by the installation of an immediate-load fixed cross-arch implant-supported restoration because primary stability was reached for 8 implants. In addition, instructions about masticatory function and how it is related to interfacial micromotion were addressed and emphasized to the patient. The reasons for the IL were further avoidance of an interim healing phase, a potential reduction in the number of clinical interventions for the patient, and aesthetic reasons. After monitoring the rehabilitation for 8 years, the authors can conclude that maxillary IL can be performed followed by a well-established treatment planning based on computed tomography, providing immediate esthetics and function to the patient even when autogenous bone graft was previously performed in the maxilla.
Resumo:
The surgical treatment of mandibular condyle fractures currently offers several possibilities for stable internal fixation. In this study, a finite element model evaluation was performed of three different methods for osteosynthesis of low subcondylar fractures: (1) two four-hole straight plates, (2) one seven-hole lambda plate, and (3) one four-hole trapezoidal plate. The finite element model evaluation considered a load applied to the first molar on the contralateral side to the fracture. Results showed that, although the three methods are capable of withstanding functional loading, the lambda plate displayed a more homogeneous stress distribution for both osteosynthesis material and bone and may be a better method when single-plate fixation is the option.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
In this study, the physicochemical characteristics of calcium phosphate based bioactive ceramics of different compositions and blends presenting similar micro/nanoporosity and micrometer scale surface texture were characterized and evaluated in an in vivo model. Prior to the animal experiment, the porosity, surface area, particle size distribution, phase quantification, and dissolution of the materials tested were evaluated. The bone regenerative properties of the materials were evaluated using a rabbit calvaria model. After 2, 4, and 8 weeks, the animals were sacrificed and all samples were subjected to histologic observation and histomorphometric analysis. The material characterization showed that all materials tested presented variation in particle size, porosity and composition with different degrees of HA/TCP/lower stoichiometry phase ratios. Histologically, the calvarial defects presented temporal bone filling suggesting that all material groups were biocompatible and osteoconductive. Among the different materials tested, there were significant differences found in the amount of bone formation as a function of time. At 8 weeks, the micro/nanoporous material presenting similar to 55,TCP:45%,HA composition ratio presented higher amounts of new bone regeneration relative to other blends and a decrease in the amount of soft tissue infiltration. (C) 2014 Elsevier B.V. All rights reserved.
Resumo:
Objective: The aim of this study was to investigate the influence of cleft type and supernumerary tooth eruption on the treatment of palatal clefts with alveolar bone grafts.Materials and Methods: In this article, medical records of 40 patients with palatal clefts and associated supernumerary teeth who were treated with alveolar bone grafting in the Hospital for Craniofacial Anomalies Rehabilitation were assessed. The patients were studied to assess the influence of supernumerary teeth and the cleft severity on the prognosis of the alveolar bone graft.Results: Forty medical records were included in the assessment. When the teeth in the cleft had an anatomic shape close to canine, we called them precanine. When they were very small or malformed, we called them anomalous lateral incisors. The teeth studied showed good prognoses and were more expressive in the preforaminal clefts (87.5%) than in the transforaminal ones (62.5%). Moreover, the transforaminal clefts presented a higher percentage in satisfactory and poor prognoses (37.5%). The authors found that supernumerary teeth influenced the maintenance of alveolar bone graft height and that transforaminal clefts presented a worse prognosis than preforaminal clefts.
Resumo:
The aim of this study was to perform a physicochemical and morphological characterization and compare the mechanical behavior of an experimental Ti-Mo alloy to the analogous metallic Ti-based fixation system, for mandibular angle fractures. Twenty-eight polyurethane mandibles were uniformly sectioned on the left angle. These were divided into 4 groups: group Eng 1P, one 2.0-mm plate and 4 screws 6 mm long; group Eng 2P, two 2.0-mm plates, the first fixed with 4 screws 6 mm long and the second with 4 screws 12 mm long. The same groups were created for the Ti-15Mo alloy. Each group was subjected to linear vertical loading at the first molar on the plated side in a mechanical testing unit. Means and standard deviations were compared with respect to statistical significance using ANOVA. The chemical composition of the Ti-15Mo alloy was close to the nominal value. The mapping of Mo and Ti showed a homogeneous distribution. SEM of the screw revealed machining debris. For the plates, only the cpTi plate undergoes a surface treatment. The metallographic analysis reveals granular microstructure, from the thermomechanical trials. A statistically significant difference was found (P < 0.05) when the comparison between both internal fixation techniques was performed. The 2P technique showed better mechanical behavior than 1P.
Resumo:
Autogenous bone grafting is the gold-standard technique for bone augmentation procedures prior to implant placement. If the amount of available intraoral donor bone is insufficient, it is necessary to harvest bone graft from extraoral sites, such as calvaria. Although this technique is well established, only a few case reports show the histological analysis of the grafted bone at the moment of implant placement. This article reports the case of a 48-year-old female patient with a critical atrophic maxillary ridge reconstructed using autogenous calvarial bone graft prior to implant placement, with clinical and histological evaluation. Bone was collected under general anesthesia from the parietal bone. The outer cortical originated the bone blocks, and the medullar bone layer between was collected to be used in the sinus augmentation procedure, together with 5 of the bone blocks triturated. Six months after bone augmentation, 8 implants were placed in the grafted area and 2 biopsies were retrieved (anterior and the posterior regions), allowing the visualization of the bone-remodeling process in the grafted areas. The patient had a stable recovery. Our results showed that although necrotic bone could still be seen in the outer layer of the grafted area, the interface between this necrotic bone and the already remodeled bone was consistent with biocompatibility. Two-year radiographic evaluation showed success of the grafts and the implants in supporting an esthetic and functionally stable prosthesis. Summarizing, calvarial bone grafts are a viable alternative for the attainment of adequate bone volume prior to implant placement.
Resumo:
Pós-graduação em Engenharia Mecânica - FEB
Resumo:
Introduction and objective: Marginal tissue recession represents a common condition in Periodontology. Miller's Classes I and II recessions, in which the etiological factors are well diagnosed and eliminated, show great predictability of total coverage when the technique of subepithelial connective tissue graft is used. This technique success has been mainly attributed to the double blood supply for graft's nutrition, originating from the connective tissue of both the periosteum and flap. Case report and conclusion: The authors reported a clinical case in which a Miller's Class I recession was treated by the surgical technique of subepithelial connective tissue graft, obtaining total coverage, eliminating the aesthetic deficiency and the dentin hypersensitivity complained by patient.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The present study aims to compare three types of internal fixation for fractures of the mandibular angle. Mechanical testing was performed on replicas of polyurethane hemimandibles sectioned at the angle region to simulate a fracture and fixed with three different hardwares. Fixation devices enrolled on this survey included the grid plates with and without an intermediate bar and the method described by Champy and colleagues in 1978 and the sample consisted of 10 hemimandibles for each group. Vertical loadings were applied on each hemimandible and recorded after a vertical displacement of 3 and 5 mm. Statistical analysis was made by means of the variance analysis (ANOVA) and the Duncan test with a significance level of 5%. The Champy technique showed a statistically significant increased resistance when compared to the grid plates after vertical displacements of 3 and 5 mm. The results of this survey suggest that the Champy technique, when compared to the grid plate positioned at the middle of the mandibular bone (placement site selected for this study), is more resistant than the grid plate and that the inclusion or not of an intermediate bar to the grid plates does not improve its resistance after linear vertical loadings.
Resumo:
Objective The objective of this article is to present options of rehabilitation with dental implants in two cases of severely atrophic mandibles (<10 mm) after rigid internal fixation of fractures. Patients and method Two patients who sustained fractures in severely atrophic mandibles with less than 10 mm of bone height were treated by open reduction and internal fixation through a transcervical access. Internal fixation was obtained with 2.4-mm locking reconstruction plates. The first patient presented satisfactory bone height at the area between the mental foramens and after 2 years, received flapless guided implants in the anterior mandible and an immediate protocol prosthesis. The second patient received a tent pole iliac crest autogenous graft after 2 years of fracture treatment and immediate implants. After 5 months, a protocol prosthesis was installed in the second patient. Results In both cases, the internal fixation followed AO principles for load-bearing osteosynthesis. Both prosthetic devices were Branemark protocol prosthesis. The mandibular reconstruction plates were not removed. Both patients are rehabilitated without complications and satisfied with esthetic and functional results. Conclusion With the current techniques of internal fixation, grafting, and guided implants, the treatment of atrophic mandible fractures can achieve very good results, which were previously not possible.
Resumo:
The sagittal split ramus osteotomy (SSRO) is a surgical technique used widely to treat many congenital and acquired mandibular discrepancies. Stabilization of the osteotomy site and the potential for skeletal relapse after the procedure are still major problems. The aim of this study was to compare the mechanical stability of six methods of rigid fixation in SSRO using a biomechanical test model. Sixty polyurethane replicas of human hemimandibles were divided into six groups. In group I, the osteotomies were fixed with two four-hole titanium miniplates; in group II, with one four-hole miniplate; in group III, with one four-hole miniplate + a bicortical screw; in group IV, with a grid miniplate; in group V, with a four-hole locking miniplate; and in group VI, with a six-hole miniplate. A linear load in the premolar region was applied to the hemimandibles. The resistance forces (N) needed to displace the distal segment by 1, 3, and 5 mm were recorded and the data transmitted from the load cell to a computer. One-way analysis of variance with Tukey's post hoc test was performed to compare the means between groups. For the three displacement conditions, there was a strong tendency for the 2.0-mm plate + screw and the grid plate to have higher values.