896 resultados para Fines and recoveries.


Relevância:

30.00% 30.00%

Publicador:

Resumo:

A rapid, robust and economical method for the analysis of persistent halogenated organic compounds in small volumes of human serum and umbilical cord blood is described. The pollutants studied cover a broad range of molecules of contemporary epidemiological and legislative concern, including polychlorobiphenyls (PCBs), polychlorobenzenes (CBs), hexachlorocyclohexanes (HCHs), DDTs, polychlorostyrenes (PCSs) and polybromodiphenyl ethers (PBDEs). Extraction and clean-up with n-hexane and concentrated sulphuric acid was followed with analysis by gas chromatography coupled to electron capture (GC-ECD) and GC coupled to negative ion chemical ionisation mass spectrometry (GC-NICI-MS). The advantages of this method rest in the broad range of analytes and its simplicity and robustness, while the use of concentrated sulphuric acid extraction/clean-up destroys viruses that may be present in the samples. Small volumes of reference serum between 50 and 1000 μL were extracted and the limits of detection/quantification and repeatability were determined. Recoveries of spiked compounds for the extraction of small volumes (≥300 μL) of the spiked reference serum were between 90% and 120%. The coefficients of variation of repeatability ranged from 0.1-14%, depending on the compound. Samples of 4-year-old serum and umbilical cord blood (n = 73 and 40, respectively) from a population inhabiting a village near a chloro-alkali plant were screened for the above-mentioned halogenated pollutants using this method and the results are briefly described. © 2010 Springer-Verlag.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Incluye bibliografía

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Includes bibliography

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Incluye Bibliografía

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A simple method to determine Cu, Fe, Mn and Zn in single aliquots of medicinal plants by HR-CS FAAS is proposed. The main lines for Cu, Mn and Zn, and the alternate line measured at the wing of the main line for Fe at 248.327 nm allowed calibration within the 0.025 - 2.0 mg L-1 Cu, 1.0 - 20.0 mg L-1 Fe, 0.05 - 2.0 mg L-1 Mn, 0.025 - 0.75 mg L-1 Zn ranges. Nineteen medicinal plants and two certified plant reference materials were analyzed. Results were in agreement at a 95% confidence level (paired t-test) with reference values. Limits of detection were 0.12 μg L-1 Cu, 330 μg L-1 Fe, 1.42 μg L-1 Mn and 8.12 μg L-1 Zn. Relative standard deviations (n=12) were ≤ 3% for all analytes. Recoveries in the 89 - 105% (Cu), 95 - 108% (Fe), 94 - 107% (Mn), and 93 - 110% (Zn) ranges were obtained.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Includes bibliography

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Includes bibliography

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The use of chemical preservative compounds is common in the food products industry. Caramel color is the most usual additive used in beverages, desserts, and breads worldwide. During its fabrication process, 2- and 4-methylimidazole (MeI), highly carcinogenic compounds, are generated. In these cases, the development of reliable analytical methods for the monitoring of undesirable compounds is necessary. The primary procedure for the analysis of 2- and 4-MeI is using LC- or GC-MS techniques. These procedures are time-consuming and require large amounts of organic solvents and several pretreatment steps. This prevents the routine use of this procedure. This paper describes a rapid, efficient, and simple method using capillary electrophoresis (CE) for the separation and determination of 2- and 4-MeI in caramel colors. The analyses were performed using a 75 μm i.d. uncoated fused-silica capillary with an effective length of 40 cm and a running electrolyte consisting of 160 mmol L-1 phosphate plus 30% acetonitrile. The pH was adjusted to 2.5 with triethylamine. The analytes were separated within 6 min at a voltage of 20 kV. Method validation revealed good repeatability of both migration time (<0.8% RSD) and peak area (<2% RSD). Analytical curves for 2- and 4-MeI were linear in the 0.4-40 mg L-1 concentration interval. Detection limits were 0.16 mg L-1 for 4-MeI and 0.22 mg L-1 for 2-MeI. The extraction recoveries were satisfactory. The developed method showed many advantages when compared to the previously used method. © 2013 American Chemical Society.