953 resultados para Filter coefficients


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes a simple, portable and environmentally friendly method for the rapid determination of dipyrone in pharmaceuticals by using diffuse reflectance spectroscopy. The proposed method is based on the reflectance measurements of the orange compound produced from the spot test reaction between dipyrone and p-dimethylaminocinnamaldehyde (p-DAC), in acid medium, using a filter paper as solid support. Experimental design methodologies were used to optimize the measurement conditions. All reflectance measurements were carried out at 510 nm and the linear range was from 1.42 × 10-4-2.85 × 10-3 mol L-1, with a correlation coefficient of 0.999. The limit of detection (LOD) and the limit of quantification (LOQ) were 1.20 × 10-5 mol L-1 and 4.00 × 10-5 mol L-1, respectively. The intraday precision and interday precision were studied for 10 replicate analyses of 7.90 × 10-4 mol L-1 dipyrone solution. The coefficients of variation were 1.1 and 0.9%, respectively. The proposed method was applied successfully to the determination of dipyrone in commercial brands of pharmaceuticals. No interferences were observed from the common excipients in formulations. The results obtained by the proposed method were favorably compared with those given by the Brazilian Pharmacopoeia procedure at 95% confidence level. ©2007 Sociedade Brasileira de Química.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper addresses the problem of processing biological data, such as cardiac beats in the audio and ultrasonic range, and on calculating wavelet coefficients in real time, with the processor clock running at a frequency of present application-specified integrated circuits and field programmable gate array. The parallel filter architecture for discrete wavelet transform (DWT) has been improved, calculating the wavelet coefficients in real time with hardware reduced up to 60%. The new architecture, which also processes inverse DWT, is implemented with the Radix-2 or the Booth-Wallace constant multipliers. One integrated circuit signal analyzer in the ultrasonic range, including series memory register banks, is presented. © 2007 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nonlinear (NL) optical properties of antimony oxide based glasses (AG) were characterized for excitation wavelengths from 800 to 1600 m. The NL refractive indices, n2, and the two-photon absorption (TPA) coefficient, β, have been evaluated using the Z-scan technique. Values of n2≈ 10-15 - 10-14 cm2/W of electronic origin were measured and negligible TPA coefficients (β < 0.003 cm/GW) were determined. The response time of the nonlinearity is faster than 100 fs as determined using the Kerr shutter technique. The figure-of-merit usually considered for all-optical switching, T = 2βλ/n2 , indicates that AG are very good materials for ultrafast switches at telecom wavelengths. © 2007 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper discusses the main characteristics and presents a comparative analysis of three synchronization algorithms based respectively, on a Phase-Locked Loop, a Kalman Filter and a Discrete Fourier Transform. It will be described the single and three-phase models of the first two methods and the single-phase model of the third one. Details on how to modify the filtering properties or dynamic response of each algorithm will be discussed in terms of their design parameters. In order to compare the different algorithms, these parameters will be set for maximum filter capability. Then, the dynamic response, during input amplitude and frequency deviations will be observed, as well as during the initialization procedure. So, advantages and disadvantages of all considered algorithms will be discussed. ©2007 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of piezocone tests with a slot filter filled with automotive grease for site characterization of tropical soils is assessed. Laboratory tests using the slot filter filled with automotive grease as well as the conventional porous piezo-element saturated with glycerin were carried out to evaluate the pore pressure (u 2) transducer response. CPTu tests using piezo-elements saturated with glycerin and the slot filter filled with grease were pushed side by side in different research sites in Brazil. Estimates of mechanical and hydraulic soil parameters were made based on pore pressure dissipation curves from using both techniques. Laboratory test results indicate that the pore pressure response using the slot filter with grease was delayed when compared to the piezo-element saturated with glycerin, since grease has a higher viscosity. For tropical soils, the records of u2 in piezocone tests using slot filter with grease presented larger peaks than with porous element saturated with glycerin. Records of u2 using the slot filter above the groundwater table suggest the increase of the degree of saturation in unsaturated zone, where porous filter can be desaturated by suction. The slot filter can be used to help the interpretation of the soil profile with deep groundwater level as well as to help detecting its position for some studied soils. The results shown high repeatability for all study sites. This technique is much easier to handle, especially for tropical soils, where the groundwater table is usually deep and pre-drilling is expensive and time consuming. © 2009 IOS Press.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper proposes a filter based on a general regression neural network and a moving average filter, for preprocessing half-hourly load data for short-term multinodal load forecasting, discussed in another paper. Tests made with half-hourly load data from nine New Zealand electrical substations demonstrate that this filter is able to handle noise, missing data and abnormal data. © 2011 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper proposes a new methodology to control the power flow between a distributed generator (DG) and the electrical power distribution grid. It is used the droop voltage control to manage the active and reactive power. Through this control a sinusoidal voltage reference is generated to be tracked by voltage loop and this loop generates the current reference for the current loop. The proposed control introduces feed-forward states improving the control performance in order to obtain high quality for the current injected to the grid. The controllers were obtained through the linear matrix inequalities (LMI) using the D-stability analysis to allocate the closed-loop controller poles. Therefore, the results show quick transient response with low oscillations. Thus, this paper presents the proposed control technique, the main simulation results and a prototype with 1000VA was developed in the laboratory in order to demonstrate the feasibility of the proposed control. © 2012 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cooling of equine semen obtained from some stallions results in lower seminal quality and viability when the seminal plasma (SP) is present. The objective of this study was to evaluate the effect of the removal of SP using a Sperm Filter on the viability of cooled stallion semen. For this purpose, 31 stallions were used. Their ejaculates were divided into three groups: CN, semen was diluted with an extender; FLT, SP was removed by filtration; and CT, SP was removed by centrifugation and cooled to 15°C for 24 hours. Sperm kinetics and plasma membrane integrity were evaluated immediately after collection (T0) and after 24 hours of refrigeration (T1). No difference (P > .05) was noted at T1 for total sperm motility (TM), progressive sperm motility, or plasma membrane integrity when semen samples from all the stallions were analyzed. However, when samples from stallions termed bad coolers were analyzed (TM = <30% at T1), a difference was observed in TM and progressive sperm motility for CN compared with FLT and CT at T1. Sperm recovery was greater when SP was removed using the filter (FLT) to that when the SP was removed by centrifugation (CN) (89% vs. 81%). Thus, we concluded that filtering with a Sperm Filter is an efficient and practical method for removal of SP from stallion ejaculates, with lower sperm loss than centrifugation. We also found that the presence of SP reduces the quality and viability of cooled semen from stallions whose semen is sensitive to the process of refrigeration. © 2013 Elsevier Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Includes bibliography

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Utilising organic residues in agriculture contributes to the conservation of natural resources by recycling carbon and mineral elements. Organic residues produced by the sugar and alcohol agroindustries have great potential for use in conservation agriculture. The production of sugar and alcohol generates large quantities of byproducts, such as filter cake and vinasse, which can be used as soil improvers and substitutes for inorganic phosphorus and potassium fertilizers. However, the use of these residues in agriculture requires specific recommendations for each pedoclimatic condition to prevent environmental damage. © 2013 Renato de Mello Prado et al.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Elétrica - FEIS

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Includes bibliography

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A determinação das concentrações sanguíneas de antimaláricos empregando métodos rápidos, simples e sensíveis, representa importante ferramenta para otimização dos esquemas terapêuticos adotados atualmente no Brasil. Neste sentido, este trabalho objetivou a validação de uma metodologia analítica por cromatografia líquida de alta eficiência com detecção no ultravioleta para determinação de cloroquina em amostras de sangue total adsorvidas em papel de filtro, oriundas de pacientes com malária vivax. Foram avaliados: precisão intra e inter ensaio, recuperação, limites de detecção e de quantificação, robustez, estabilidade, linearidade e seletividade. Os resultados demonstraram que os coeficientes de variação intra ensaio em concentrações de 100 a 1000 ng/mL variou de 6 a 10% tanto para cloroquina, quanto para desetilcloroquina. Os coeficientes de variação inter ensaio em concentrações de 100 a 1000 ng/mL variaram de 5 a 10% e 4 a 10% para cloroquina e desetilcloroquina, respectivamente. Os limites de detecção foram 62.5ng/mL para cloroquina e 50.0ng/mL para desetilcloroquina e os limites de quantificação foram 100ng/mL para ambos os analitos. A recuperação em concentração de 100 a 1000 ng/mL variou de 90 a 105% e 95 a 105%, para cloroquina e desetilcloroquina, respectivamente. O método foi linear em intervalo de concentração de 100 ng/mL a 2000 para cloroquina e de 100 a 800 ng/mL para desetilcloroquina. O método foi robusto para pequenas variações de fluxo, pH da fase móvel e composição da fase orgânica. Não foram observados interferentes no procedimento validado dentre aqueles fármacos utilizados no tratamento da malária. A determinação de cloroquina e desetilcloroquina em pacientes com malária vivax cujos valores médios foram de 1266±455 ng/mL e 357±165ng/mL, caracterizaram a aplicabilidade do procedimento validado para a determinação deste antimalárico nestes pacientes.