910 resultados para Field testing and monitoring,


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dystrophin is a subsarcolemmal protein critical for the integrity of muscle fibers by linking the actin cytoskeleton to the extracellular matrix via the dystroglycan complex. It is reported that dystroglycans are also localized in the skin, at dermal-epidermal junction. Here we show that epidermal melanocytes express dystrophin at the interface with the basement membrane. The full-length muscle isoform mDp427 was clearly detectable in epidermis and in melanocyte cultures as assessed by RNA and western blot analysis. Dystrophin was absent in Duchenne Muscular Dystrophy (DMD) patients melanocytes, and the ultrastructural analysis revealed mitochondrial alterations, similar to those occurring in myoblasts from the same patients. Interestingly, mitochondrial dysfunction of DMD melanocytes reflected the alterations identified in dystrophin-deficient muscle cells. In fact, mitochondria of melanocytes from DMD patients accumulated tetramethylrhodamine methyl ester but, on the contrary of control donor, mitochondria of DMD patients readily depolarized upon the addition of oligomycin, suggesting either that they are maintaining the membrane potential at the expense of glycolytic ATP, or that they are affected by a latent dysfunction unmasked by inhibition of the ATP synthase. Melanocyte cultures can be easily obtained by conventional skin biopsies, less invasive procedure than muscular biopsy, so that they may represent an alternative cellular model to myoblast for studying and monitoring dystrophinopathies also in response to pharmacological treatments.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this thesis we will investigate some properties of one-dimensional quantum systems. From a theoretical point of view quantum models in one dimension are particularly interesting because they are strongly interacting, since particles cannot avoid each other in their motion, and you we can never ignore collisions. Yet, integrable models often generate new and non-trivial solutions, which could not be found perturbatively. In this dissertation we shall focus on two important aspects of integrable one- dimensional models: Their entanglement properties at equilibrium and their dynamical correlators after a quantum quench. The first part of the thesis will be therefore devoted to the study of the entanglement entropy in one- dimensional integrable systems, with a special focus on the XYZ spin-1/2 chain, which, in addition to being integrable, is also an interacting model. We will derive its Renyi entropies in the thermodynamic limit and its behaviour in different phases and for different values of the mass-gap will be analysed. In the second part of the thesis we will instead study the dynamics of correlators after a quantum quench , which represent a powerful tool to measure how perturbations and signals propagate through a quantum chain. The emphasis will be on the Transverse Field Ising Chain and the O(3) non-linear sigma model, which will be both studied by means of a semi-classical approach. Moreover in the last chapter we will demonstrate a general result about the dynamics of correlation functions of local observables after a quantum quench in integrable systems. In particular we will show that if there are not long-range interactions in the final Hamiltonian, then the dynamics of the model (non equal- time correlations) is described by the same statistical ensemble that describes its statical properties (equal-time correlations).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this thesis we discuss a representation of quantum mechanics and quantum and statistical field theory based on a functional renormalization flow equation for the one-particle-irreducible average effective action, and we employ it to get information on some specific systems.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Testing e Analisi di problemi di usabilità che potrebbero sorgere se due sistemi venissero integrati in un unico nuovo sistema.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An imaging biomarker that would provide for an early quantitative metric of clinical treatment response in cancer patients would provide for a paradigm shift in cancer care. Currently, nonimage based clinical outcome metrics include morphology, clinical, and laboratory parameters, however, these are obtained relatively late following treatment. Diffusion-weighted MRI (DW-MRI) holds promise for use as a cancer treatment response biomarker as it is sensitive to macromolecular and microstructural changes which can occur at the cellular level earlier than anatomical changes during therapy. Studies have shown that successful treatment of many tumor types can be detected using DW-MRI as an early increase in the apparent diffusion coefficient (ADC) values. Additionally, low pretreatment ADC values of various tumors are often predictive of better outcome. These capabilities, once validated, could provide for an important opportunity to individualize therapy thereby minimizing unnecessary systemic toxicity associated with ineffective therapies with the additional advantage of improving overall patient health care and associated costs. In this report, we provide a brief technical overview of DW-MRI acquisition protocols, quantitative image analysis approaches and review studies which have implemented DW-MRI for the purpose of early prediction of cancer treatment response.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES To compare longitudinal patterns of health care utilization and quality of care for other health conditions between breast cancer-surviving older women and a matched cohort without breast cancer. DESIGN Prospective five-year longitudinal comparison of cases and matched controls. SUBJECTS Newly identified breast cancer patients recruited during 1997–1999 from four geographic regions (Los Angeles, CA; Minnesota; North Carolina; and Rhode Island; N = 422) were matched by age, race, baseline comorbidity and zip code location with up to four non-breast-cancer controls (N = 1,656). OUTCOMES Survival; numbers of hospitalized days and physician visits; total inpatient and outpatient Medicare payments; guideline monitoring for patients with cardiovascular disease and diabetes, and bone density testing and colorectal cancer screening. RESULTS Five-year survival was similar for cases and controls (80% and 82%, respectively; p = 0.18). In the first follow-up year, comorbidity burden and health care utilization were higher for cases (p < 0.01), with most differences diminishing over time. However, the number of physician visits was higher for cases (p < 0.01) in every year, driven partly by more cancer and surgical specialist visits. Cases and controls adhered similarly to recommended bone density testing, and monitoring of cardiovascular disease and diabetes; adherence to recommended colorectal cancer screening was better among cases. CONCLUSION Breast cancer survivors’ health care utilization and disease burden return to pre-diagnosis levels after one year, yet their greater use of outpatient care persists at least five years. Quality of care for other chronic health problems is similar for cases and controls.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

There is a demand for technologies able to assess the perfusion of surgical flaps quantitatively and reliably to avoid ischemic complications. The aim of this study is to test a new high-speed high-definition laser Doppler imaging (LDI) system (FluxEXPLORER, Microvascular Imaging, Lausanne, Switzerland) in terms of preoperative mapping of the vascular supply (perforator vessels) and postoperative flow monitoring. The FluxEXPLORER performs perfusion mapping of an area 9 x 9 cm with a resolution of 256 x 256 pixels within 6 s in high-definition imaging mode. The sensitivity and predictability to localize perforators is expressed by the coincidence of preoperatively assessed LDI high flow spots with intraoperatively verified perforators in nine patients. 18 free flaps are monitored before, during, and after total ischemia. 63% of all verified perforators correspond to a high flow spot, and 38% of all high flow spots correspond to a verified perforator (positive predictive value). All perfused flaps reveal a value of above 221 perfusion units (PUs), and all values obtained in the ischemic flaps are beneath 187 PU. In summary, we conclude that the present LDI system can serve as a reliable, fast, and easy-to-handle tool to detect ischemia in free flaps, whereas perforator vessels cannot be detected appropriately.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A low simplified Pulmonary Embolism Severity Index (sPESI), defined as age ≤80 years and absence of systemic hypotension, tachycardia, hypoxia, cancer, heart failure, and lung disease, identifies low-risk patients with acute pulmonary embolism (PE). It is unknown whether cardiac troponin testing improves the prediction of clinical outcomes if the sPESI is not low. In the prospective Swiss Venous Thromboembolism Registry, 369 patients with acute PE and a troponin test (conventional troponin T or I, highly sensitive troponin T) were enrolled from 18 hospitals. A positive test result was defined as a troponin level above the manufacturers assay threshold. Among the 106 (29%) patients with low sPESI, the rate of mortality or PE recurrence at 30 days was 1.0%. Among the 263 (71%) patients with high sPESI, 177 (67%) were troponin-negative and 86 (33%) troponin-positive; the rate of mortality or PE recurrence at 30 days was 4.6% vs. 12.8% (p=0.015), respectively. Overall, risk assessment with a troponin test (hazard ratio [HR] 3.39, 95% confidence interval [CI] 1.38-8.37; p=0.008) maintained its prognostic value for mortality or PE recurrence when adjusted for sPESI (HR 5.80, 95%CI 0.76-44.10; p=0.09). The combination of sPESI with a troponin test resulted in a greater area under the receiver-operating characteristic curve (HR 0.72, 95% CI 0.63-0.81) than sPESI alone (HR 0.63, 95% CI 0.57-0.68) (p=0.023). In conclusion, although cardiac troponin testing may not be required in patients with a low sPESI, it adds prognostic value for early death and recurrence for patients with a high sPESI.

Relevância:

100.00% 100.00%

Publicador:

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Stress corrosion cracking susceptibility was investigated for an ultra-fine grained (UFG) AI-7.5Mg alloy and a conventional 5083 H111 alloy in natural seawater using slow strain rate testing (SSRT) at very slow strain rates between 1E(-5) s(-1), 1E(-6) s(-1) and 1E(-7) s(-1). The UFG Al-7.5Mg alloy was produced by cryomilling, while the 5083 H111 alloy is considered as a wrought manufactured product. The response of tensile properties to strain rate was analyzed and compared. Negative strain rate sensitivity was observed for both materials in terms of the elongation to failure. However, the UFG alloy displayed strain rate sensitivity in relation to strength while the conventional alloy was relatively strain rate insensitive. The mechanical behavior of the conventional 5083 alloy was attributed to dynamic strain aging (DSA) and delayed pit propagation while the performance of the UFG alloy was related to a diffusion-mediated stress relaxation mechanism that successfully delayed crack initiation events, counteracted by exfoliation and pitting which enhanced crack initiation. (C) 2014 Elsevier B.V. All rights reserved.