969 resultados para Erythrocytes interferences


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Spectrophotometric determination of total protein is used in several areas such as clinical analysis, food science and technology, biochemistry, protein chemistry, physiology. Five spectrophotometric methods are mostly used: biuret, Lowry, Bradford, Smith and UV absorption. In this review a general overview of these methods is presented (interferences, applications); other methodologies are also discussed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Selectivity studies for the determination of Cr(VI) using the catalytic oxidation of the o-dianisidine by hydrogen peroxide showed two distincts situations. In the first, when interferents were studied by a univariate procedure, Cr(III) and Cu(II) cause serious interferences even at the 2:1 proportion, relative to Cr(VI), while Fe(III) interfered at the 15:1 ratio and EDTA at the 10:1 ratio. On the other hand, when a multivariate investigation was performed, Cr(III) did not present any significant principal effects and its significant interaction effects were negative, in contrast to EDTA, that presented positive interaction effects although, like Cr(III), did not show significant interaction effects. In view of the interferent's action it become necessary to separate Cr(VI) by extraction with methylisobutylketone in a chloridric acid medium before its determination in vegetals and in wastewater from a cellulose industry samples. Using this procedure, the method precision is ±0,5% at the 10 ng/mL Cr(VI) concentration level. The detection and quantification limits, calculated by means of absorbance measurements of ten replicates of blank reagents were 1,1 and 3,2 ng/mL, respectively. The results obtained with real samples showed a relative standard deviation between 1,2% and 3,0% relative to their reference values.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

ELISAs have been applied to pesticide residue analysis due to their high sensitivity and selectivity. However, some ELISAs performance may be affected by matrix components. In this work, ELISA for carbaryl in water samples was checked for interference by naturally occurring fulvic acids. The results suggested that the high fulvic acid concentration (ž³30 mg L-1) and acidic pH conditions (pH 4.0) interfere with the signal detection decreasing the method sensitivity. A dilution of the samples and adjust to pH 8.0 are appropriate to minimize the matrix interferences in the ELISA method. Good correlation between ELISA and HPLC-DAD results was observed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In the present work four different analytical methodologies were studied for the determination of iron and titanium in Portland cement. The cement samples were dissolved with hot HCl and HF, being compared Fe and Ti concentrations through four analytical methods: molecular absorption spectrophotometry using the reagents 1,2-hydroxybenzene-3,5-disulfonic acid (Tiron) and the 5-chloro-salicylic acid (CSA), inductively coupled plasma atomic emission spectrometry (ICP-AES) and flame atomic absorption spectrophotometry (FAAS). In the spectrophotometric determinations were studied pH conditions, reagents addition order, interferences, amount of reagents, linear range and stability of the system. In the techniques of ICP-AES and FAAS were studied the best lines, interferences, sensibility and linear range. The obtained results were compared and the agreement was evaluated among the methods for the determination of the metals of interest.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

One of the main problems in quantitative analysis of complex samples by x-ray fluorescence is related to interelemental (or matrix) effects. These effects appear as a result of interactions among sample elements, affecting the x-ray emission intensity in a non-linear manner. Basically, two main effects occur; intensity absorption and enhancement. The combination of these effects can lead to serious problems. Many studies have been carried out proposing mathematical methods to correct for these effects. Basic concepts and the main correction methods are discussed here.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Simultaneous electrolytic deposition is proposed for minimization of Cu2+ and Pb2+ interferences on automated determination of Cd2+ by the Malachite Green-iodide reaction. During electrolysis of sample in a cell with two Pt electrodes and a medium adjusted to 5% (v/v) HNO3 + 0.1% (v/v) H2SO4 + 0.5 mol L-1 NaCl, Cu2+ is deposited as Cu on the cathode, Pb2+ is deposited as PbO2 on the anode while Cd2+ is kept in solution. With 60 s electrolysis time and 0.25 A current, Pb2+ and Cu2+ levels up to 50 and 250 mg L-1 respectively, can be tolerated without interference. With on-line extraction of Cd2+ in anionic resin minicolumn, calibration graph in the 5.00 - 50.0 µg Cd L-1 range is obtained, corresponding to twenty measurements per hour, 0.7 mg Malachite Green and 500 mg KI and 5 mL sample consumed per determination. Results of the determination of Cd in certified reference materials, vegetables and tap water were in agreement with certified values and with those obtained by GFAAS at 95% confidence level. The detection limit is 0.23 µg Cd L-1 and the RSD for typical samples containing 13.0 µg Cd L-1 was 3.85 % (n= 12).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this work was to compare the performances of the L'vov and integrated platforms in order to overcome the interferences found on lead determination in zidovudine by ET AAS. Pyrolysis and atomization temperatures found with integrated platform were 700 and 1400°C, respectively. The characteristic masses were 12.7 ± 1.2 pg with integrated platform and 11.1 ± 1.3 pg with grooved platform. The ratio between the slopes of zidovudine and aqueous curves shows a decrease in the interferences when the L'vov platform is used (bAZT/b aq = 0.97 ± 0.10) and the detection limit found was 0.03 µg.g-1. That ratio was 0.85 ± 0.07 with the integrated platform.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This review focuses the development of electrochemical detection systems coupled to capillary electrophoresis. Conductometric, amperometric, voltametric, and potentiometric modes of detection are reviewed. The positioning of the electrodes, interferences of high electric field, and the materials employed in the fabrication and modification of the electrodes are discussed. The advantages of the use of electrochemical detection with capillary electrophoresis, regarding to the sensitivity and selectivity, is exemplified with a large number of applications. Also, the use of electrochemical detection systems in microchip technology is addressed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The construction and analytical evaluation of a coated graphite Al(III) ion-selective electrode, based on the ionic pair formed between the Al(F)n3-n anion and tricaprylylmethylammonium cation (Aliquat 336S) incorporated on a poly(vinylchloride) (PVC) matrix membrane are described. A thin membrane film of this ionic pair and dibutylphthalate (DBPh) in PVC was deposited directly on a cylindric graphite rod (2 cm length x 0.5 cm diameter) attached to the end of a glass tube using epoxy resin. The membrane solution was prepared by dissolving 40% (m/m) of PVC in 10 mL of tetrahydrofuran following addition of 45% (m/m) of DBPh and 15% (m/m) of the ionic pair. The effect of membrane composition, fluoride concentration, and several concomitants as potential interferences on the electrode response were investigated. The aluminium(III) ion-selective electrode showed a linear response ranging from 1.4 x 10-4 to 1.0 x 10-2 mol L-1, a detection limit of 4.0 x 10-5 mol L-1, aslope of -54.3±0.2mV dec-1 and a lifetime of more than 1 year (over 3000 determinations for each membrane). The slope indicates that the ion-selective electrode responds preferentially to the Al(F)4- species. Application of this electrode for the aluminium(III) determination in stomach anti-acid samples is reported.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Al2O3 is the most abundantly produced nanomaterial and has been used in diverse fields, including the medical, military and industrial sectors. As there are concerns about the health effects of nanoparticles, it is important to understand how they interact with cells, and specifically with red blood cells. The hemolysis induced by three commercial nano-sized aluminum oxide particles (nanopowder 13 nm, nanopowder <50 nm and nanowire 2-6 nm × 200-400 nm) was compared to aluminum oxide and has been studied on erythrocytes from humans, rats and rabbits, in order to elucidate the mechanism of action and the influence of size and shape on hemolytic behavior. The concentrations inducing 50% hemolysis (HC50) were calculated for each compound studied. The most hemolytic aluminum oxide particles were of nanopowder 13, followed by nanowire and nanopowder 50. The addition of albumin to PBS induced a protective effect on hemolysis in all the nano-forms of Al2O3, but not on Al2O3. The drop in HC50 correlated to a decrease in nanomaterial size, which was induced by a reduction of aggregation Aluminum oxide nanoparticles are less hemolytic than other oxide nanoparticles, and behave differently depending on the size and shape of the nanoparticles. The hemolytic behavior of aluminum oxide nanoparticles differs from that of aluminum oxide.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Al2O3 is the most abundantly produced nanomaterial and has been used in diverse fields, including the medical, military and industrial sectors. As there are concerns about the health effects of nanoparticles, it is important to understand how they interact with cells, and specifically with red blood cells. The hemolysis induced by three commercial nano-sized aluminum oxide particles (nanopowder 13 nm, nanopowder <50 nm and nanowire 2-6 nm × 200-400 nm) was compared to aluminum oxide and has been studied on erythrocytes from humans, rats and rabbits, in order to elucidate the mechanism of action and the influence of size and shape on hemolytic behavior. The concentrations inducing 50% hemolysis (HC50) were calculated for each compound studied. The most hemolytic aluminum oxide particles were of nanopowder 13, followed by nanowire and nanopowder 50. The addition of albumin to PBS induced a protective effect on hemolysis in all the nano-forms of Al2O3, but not on Al2O3. The drop in HC50 correlated to a decrease in nanomaterial size, which was induced by a reduction of aggregation Aluminum oxide nanoparticles are less hemolytic than other oxide nanoparticles, and behave differently depending on the size and shape of the nanoparticles. The hemolytic behavior of aluminum oxide nanoparticles differs from that of aluminum oxide.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

En aquest article ens proposem demostrar que la història del català del segle XVI ençà està caracteritzada per tres fenòmens sense els quals no podem entendre tampoc la situació actual: reculada en els usos socials de la llengua, baixa cohesió de la comunitat lingüística, i augment de la variació interna i les interferències. Aquestes tres constants, però, s'han corregit en part des de finals del XIX, segons l'àmbit i el territori. Al nostre parer, allò que singularitza el català entre les llengües europees és aquesta combinació paradoxal de reculades i recuperacions durant l'edat contemporània. This paper aims to demonstrate that the history of Catalan from the 16th century onwards is characterized by three phenomena without which the current situation of this language cannot be understood. These three phenomena are regression in social practices, low cohesion of the language community and increase of its internal variation as well as interferences. Nevertheless, those phenomena have been partially mitigated from the late 19th century depending on the domain and area concerned. In our view, what singles out Catalan among all European languages is this paradoxical combination of setbacks and recoveries in the late modern age.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In the present work three ferroin reagents were studied for the simultaneous spectrophotometric determination of iron and copper: 1,10-phenanthroline, 2,2'-bipyridine and 2,4,6-tri(2-pyridyl)-1,3,5-triazine. Effect of pH, conditions, order reagent addition, interferences, amount of reagents, lineal range, sensitivity and stability of each system were compared. The 2,4,6-tri(2-pyridyl)-1,3,5-triazine can be used for determination of iron in the presence of copper with a detection limit of 5 µg L-1 and coefficient of variation of 2.0%; However it was not possible to determine directly copper in the presence of iron with this reagent. 1,10-phenanthroline can be used for simultaneous determination of the metallic ions with detection limits of 7 and 8 mg L-1 and coefficients of variation of 1.8 and 2.3% in the determination of iron and copper, respectively. The results showed also that 2,2'-bipyridine can be used for simultaneous determination of the metallic ions with detection limits of 11 and 32 µg L-1 and coefficients of variation of 1.9 and 2.5% in the determination of iron and copper, respectively. The reagents were used for spectrophotometric determination of iron and copper in ethanol fuel.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Large differences in reduced glutathione (GSH) levels have been found in different investigations, also in healthy people. GSH oxidation in vitro has been associated with sample acidification in the presence of oxihemoglobin. In this work, the influence of different acids on GSH determination utilizing HPLC with UV detection was evaluated. The results showed that metaphosphoric acid and sulfosalicylic acid were inadequate for analysis, because metaphosphoric acid showed to be inefficient for deproteinization and with sulfosalicylic acid loss of GSH was observed. Trichloroacetic acid did not effect GSH quantification, since the deproteinized form was immediately derivatized with 5, 5´-dithio-bis (2-nitrobenzoic) acid. Methods with TCA deproteinization presented linear results from 0.5 to 3.0 mM. The correlation coefficient between aqueous curves and GSH spiked RBC exceeded 0.99. Precision calculations showed CV lower than 10% and bias within ± 10% for concentrations of 0.5; 1.5 and 3.0 mM GSH. The recovery was higher than 94%. Moreover, GSH blood concentrations were independent of hemoglobin concentrations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

COD is an important parameter to estimate the concentration of organic contaminants. The closed system technique with the use of K2Cr2O7 is the most important one, however, it has the inconvenience to suffer positive chemical interferences from inorganic compounds such as Fe2+ and H2O2 (not enough reported in the literature). This paper considers a statistical-experimental set capable to validate a empirical mathematical model generated from a 23 experimental design, in the presence of Fe2+ and H2O2. The t test shows that mathematical model has 99,99999% confidence degree and the experimental validation test indicates absolute mean error of 4,70%.