960 resultados para Error in essence


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Adequate in-vitro training in valved stents deployment as well as testing of the latter devices requires compliant real-size models of the human aortic root. The casting methods utilized up to now are multi-step, time consuming and complicated. We pursued a goal of building a flexible 3D model in a single-step procedure. We created a precise 3D CAD model of a human aortic root using previously published anatomical and geometrical data and printed it using a novel rapid prototyping system developed by the Fab@Home project. As a material for 3D fabrication we used common house-hold silicone and afterwards dip-coated several models with dispersion silicone one or two times. To assess the production precision we compared the size of the final product with the CAD model. Compliance of the models was measured and compared with native porcine aortic root. Total fabrication time was 3 h and 20 min. Dip-coating one or two times with dispersion silicone if applied took one or two extra days, respectively. The error in dimensions of non-coated aortic root model compared to the CAD design was <3.0% along X, Y-axes and 4.1% along Z-axis. Compliance of a non-coated model as judged by the changes of radius values in the radial direction by 16.39% is significantly different (P<0.001) from native aortic tissue--23.54% at the pressure of 80-100 mmHg. Rapid prototyping of compliant, life-size anatomical models with the Fab@Home 3D printer is feasible--it is very quick compared to previous casting methods.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The work presented evaluates the statistical characteristics of regional bias and expected error in reconstructions of real positron emission tomography (PET) data of human brain fluoro-deoxiglucose (FDG) studies carried out by the maximum likelihood estimator (MLE) method with a robust stopping rule, and compares them with the results of filtered backprojection (FBP) reconstructions and with the method of sieves. The task of evaluating radioisotope uptake in regions-of-interest (ROIs) is investigated. An assessment of bias and variance in uptake measurements is carried out with simulated data. Then, by using three different transition matrices with different degrees of accuracy and a components of variance model for statistical analysis, it is shown that the characteristics obtained from real human FDG brain data are consistent with the results of the simulation studies.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This manual captures the experience of practitioners in the Iowa Department of Transportation’s (Iowa DOT’s) Office of Location and Environment (OLE). It also documents the need for coordinated project development efforts during the highway project planning, or location study phase and engineering design. The location study phase establishes: * The definition of, and need for, the highway improvement project * The range of alternatives and many key attributes of the project’s design * The recommended alternative, its impacts, and the agreed-to conditions for project approval The location study process involves developing engineering alternatives, collecting engineering and environmental data, and completing design refinements to accomplish functional designs. The items above also embody the basic content required for projects compliant with the National Environmental Policy Act (NEPA) of 19691, which directs federal agencies to use a systematic, interdisciplinary approach during the planning process whenever proposed actions (or “projects”) have the potential for environmental impacts. In doing so, NEPA requires coordination with stakeholders, review, comment, and public disclosure. Are location studies and environmental studies more about the process or the documents? If properly conducted, they concern both—unbiased and reasonable processes with quality and timely documents. In essence, every project is a story that needs to be told. Engineering and environmental regulations and guidance, as documented in this manual, will help project staff and managers become better storytellers.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Mineralogical, K-Ar, Rb-Sr and stable isotope analyses have been carried out on K-white micas from Helvetic Malm limestones in order to examine their evolution during very low- to low-grade Alpine metamorphism, associated with intense ductile deformation. Metamorphic temperatures were estimated al approximately 300-degrees-C from stable isotopes (quartz-calcite thermometry), occurrence of chloritoid, and `'epizonal'' illite crystallinity index. K-white micas consist of variable mixtures of 2M, phengite and muscovite, as revealed by detailed X-ray diffraction analyses using peak decomposition of the (060, 331) spectra. K-Ar apparent ages display a strong grain-size dependence in which mainly fine-grained size fractions (< 2 mum) record Alpine ages (37-15 Ma). However, these ages provide a relative rather than an absolute chronology of the diachronous Alpine metamorphic evolution of the Helvetic nappes. The resetting of the K-Ar isotopic system of K-white micas to Alpine metamorphic conditions reflects an apparent combination of crystallization/recrystallization and radiogenic Ar-40 diffusion loss. The oxygen isotope compositions of micas (+ 15 to + 22 parts per thousand) are intermediate between detrital and O-18-enriched values expected for micas neoformed within an abundant marine carbonate matrix. No isotopic equilibrium has been reached between calcite and micas. The variable depletion of hydrogen isotope compositions (- 126 to - 82 parts per thousand) is influenced by the interaction with organic matter under closed-system conditions. Organic matter, if not removed, may also represent a serious source of error in K-Ar age determination, by introducing radiogenic Ar-40 contamination. Sr-87/Sr-86 isotope ratios of micas range from 0.70879 to 0.70902 with one outlier at 0.71794. The low values reflect Sr exchange with calcite occurring during crystallization/recrystallization of micas under closed-system conditions.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Moisture sensitivity of Hot Mix Asphalt (HMA) mixtures, generally called stripping, is a major form of distress in asphalt concrete pavement. It is characterized by the loss of adhesive bond between the asphalt binder and the aggregate (a failure of the bonding of the binder to the aggregate) or by a softening of the cohesive bonds within the asphalt binder (a failure within the binder itself), both of which are due to the action of loading under traffic in the presence of moisture. The evaluation of HMA moisture sensitivity has been divided into two categories: visual inspection test and mechanical test. However, most of them have been developed in pre-Superpave mix design. This research was undertaken to develop a protocol for evaluating the moisture sensitivity potential of HMA mixtures using the Nottingham Asphalt Tester (NAT). The mechanisms of HMA moisture sensitivity were reviewed and the test protocols using the NAT were developed. Different types of blends as moisture-sensitive groups and non-moisture-sensitive groups were used to evaluate the potential of the proposed test. The test results were analyzed with three parameters based on performance character: the retained flow number depending on critical permanent deformation failure (RFNP), the retained flow number depending on cohesion failure (RFNC), and energy ratio (ER). Analysis based on energy ratio of elastic strain (EREE ) at flow number of cohesion failure (FNC) has higher potential to evaluate the HMA moisture sensitivity than other parameters. If the measurement error in data-acquisition process is removed, analyses based on RFNP and RFNC would also have high potential to evaluate the HMA moisture sensitivity. The vacuum pressure saturation used in AASHTO T 283 and proposed test has a risk to damage specimen before the load applying.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Whole-body counting is a technique of choice for assessing the intake of gamma-emitting radionuclides. An appropriate calibration is necessary, which is done either by experimental measurement or by Monte Carlo (MC) calculation. The aim of this work was to validate a MC model for calibrating whole-body counters (WBCs) by comparing the results of computations with measurements performed on an anthropomorphic phantom and to investigate the effect of a change in phantom's position on the WBC counting sensitivity. GEANT MC code was used for the calculations, and an IGOR phantom loaded with several types of radionuclides was used for the experimental measurements. The results show a reasonable agreement between measurements and MC computation. A 1-cm error in phantom positioning changes the activity estimation by >2%. Considering that a 5-cm deviation of the positioning of the phantom may occur in a realistic counting scenario, this implies that the uncertainty of the activity measured by a WBC is ∼10-20%.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Nationally, there are questions regarding the design, fabrication, and erection of horizontally curved steel girder bridges due to unpredicted girder displacements, fit-up, and locked-in stresses. One reason for the concerns is that up to one-quarter of steel girder bridges are being designed with horizontal curvature. There is also an urgent need to reduce bridge maintenance costs by eliminating or reducing deck joints, which can be achieved by expanding the use of integral abutments to include curved girder bridges. However, the behavior of horizontally curved bridges with integral abutments during thermal loading is not well known nor understood. The purpose of this study was to investigate the behavior of horizontal curved bridges with integral abutment (IAB) and semi-integral abutment bridges (SIAB) with a specific interest in the response to changing temperatures. The long-term objective of this effort is to establish guidelines for the use of integral abutments with curved girder bridges. The primary objective of this work was to monitor and evaluate the behavior of six in-service, horizontally curved, steel-girder bridges with integral and semi-integral abutments. In addition, the influence of bridge curvature, skew and pier bearing (expansion and fixed) were also part of the study. Two monitoring systems were designed and applied to a set of four horizontally curved bridges and two straight bridges at the northeast corner of Des Moines, Iowa—one system for measuring strains and movement under long term thermal changes and one system for measuring the behavior under short term, controlled live loading. A finite element model was developed and validated against the measured strains. The model was then used to investigate the sensitivity of design calculations to curvature, skew and pier joint conditions. The general conclusions were as follows: (1) There were no measurable differences in the behavior of the horizontally curved bridges and straight bridges studied in this work under thermal effects. For preliminary member sizing of curved bridges, thermal stresses and movements in a straight bridge of the same length are a reasonable first approximation. (2) Thermal strains in integral abutment and semi-integral abutment bridges were not noticeably different. The choice between IAB and SIAB should be based on life – cycle costs (e.g., construction and maintenance). (3) An expansion bearing pier reduces the thermal stresses in the girders of the straight bridge but does not appear to reduce the stresses in the girders of the curved bridge. (4) An analysis of the bridges predicted a substantial total stress (sum of the vertical bending stress, the lateral bending stress, and the axial stress) up to 3 ksi due to temperature effects. (5) For the one curved integral abutment bridge studied at length, the stresses in the girders significantly vary with changes in skew and curvature. With a 10⁰ skew and 0.06 radians arc span length to radius ratio, the curved and skew integral abutment bridges can be designed as a straight bridge if an error in estimation of the stresses of 10% is acceptable.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Effective winter maintenance makes use of freezing-point-depressant chemicals (also known as ice-control products) to prevent the formation of the bond between snow and ice and the highway pavement. In performing such winter maintenance, the selection of appropriate ice-control products for the bond prevention task involves consideration of a number of factors, as indicated in Nixon and Williams (2001). The factors are in essence performance measurements of the ice-control products, and as such can be easily incorporated into a specification document to allow for selection of the best ice-control products for a given agency to use in its winter maintenance activities. Once performance measures for de-icing or anti-icing chemicals have been specified, this allows the creation of a quality control program for the acceptance of those chemicals. This study presents a series of performance measurement tests for ice-control products, and discusses the role that they can play in such a quality control program. Some tests are simple and rapid enough that they can be performed on every load of icecontrol products received, while for others, a sampling technique must be used. An appropriate sampling technique is presented. Further, each test is categorized as to whether it should be applied to every load of ice-control products or on a sampling basis. The study includes a detailed literature review that considers the performance of ice-control products in three areas: temperature related performance, product consistency, and negative side effects. The negative side effects are further broken down into three areas, namely operational side effects (such as chemical slipperiness), environmental side effects, and infrastructural side effects (such as corrosion of vehicles and damage to concrete). The review indicated that in the area of side effects the field performance of ice-control products is currently so difficult to model in the laboratory that no particular specification tests can be recommended at this time. A study of the impact of ice-control products on concrete was performed by Professor Wang of Iowa State University as a sub-contract to this study, and has been presented to the Iowa Highway Research Board prior to this report.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

This paper describes a mesurement system designed to register the displacement of the legs using a two-dimensional laser range sensor with a scanning plane parallel to the ground and extract gait parameters. In the proposed methodology, the position of the legs is estimated by fitting two circles with the laser points that define their contour and the gait parameters are extracted applying a step-line model to the estimated displacement of the legs to reduce uncertainty in the determination of the stand and swing phase of the gait. Results obtained in a range up to 8 m shows that the systematic error in the location of one static leg is lower than 10 mm with and standard deviation lower than 8 mm; this deviation increases to 11 mm in the case of a moving leg. The proposed measurement system has been applied to estimate the gait parameters of six volunteers in a preliminary walking experiment.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Electrical impedance tomography (EIT) allows the measurement of intra-thoracic impedance changes related to cardiovascular activity. As a safe and low-cost imaging modality, EIT is an appealing candidate for non-invasive and continuous haemodynamic monitoring. EIT has recently been shown to allow the assessment of aortic blood pressure via the estimation of the aortic pulse arrival time (PAT). However, finding the aortic signal within EIT image sequences is a challenging task: the signal has a small amplitude and is difficult to locate due to the small size of the aorta and the inherent low spatial resolution of EIT. In order to most reliably detect the aortic signal, our objective was to understand the effect of EIT measurement settings (electrode belt placement, reconstruction algorithm). This paper investigates the influence of three transversal belt placements and two commonly-used difference reconstruction algorithms (Gauss-Newton and GREIT) on the measurement of aortic signals in view of aortic blood pressure estimation via EIT. A magnetic resonance imaging based three-dimensional finite element model of the haemodynamic bio-impedance properties of the human thorax was created. Two simulation experiments were performed with the aim to (1) evaluate the timing error in aortic PAT estimation and (2) quantify the strength of the aortic signal in each pixel of the EIT image sequences. Both experiments reveal better performance for images reconstructed with Gauss-Newton (with a noise figure of 0.5 or above) and a belt placement at the height of the heart or higher. According to the noise-free scenarios simulated, the uncertainty in the analysis of the aortic EIT signal is expected to induce blood pressure errors of at least ± 1.4 mmHg.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Tämän työn tavoitteena oli reaktiokalorimetrin käyttöönotto sekä sen käyttökelpoisuuden selvittäminen hydrometallurgisten sovellusten ja erityisesti sinkkisulfidin liuotuksen tutkimiseen. Työn kirjallisuusosassa on käsitelty yleisellä tasolla kalorimetrian ja reaktiokalorimetrian teoriaa, termodynamiikkaa sekä sinkkirikasteen liuotuksen kemiaa. Lisäksi työssä esitellään erilaisten kalorimetrien ja termoanalyyttisten mittauslaitteiden toimintaperiaatteita. Työn kokeellisessa osassa selvitettiin reaktiokalorimetrin mittaustulosten tarkkuutta vesi- kokeiden avulla. Laitteistolla määritettiin myös reaktiolämmöt sinkkisulfidin liukenemisreaktiolle sekä elohopeasuolan saostusreaktiolle. Lisäksi tutkittiin sekoitusnopeuden, lämpötilan ja kiintoainepitoisuuden vaikutusta mittaustuloksiin. Reaktiokalorimetrillä suoritettujen kokeiden perusteella havaittiin, että reaktiolämpöjen absoluuttisten arvojen määrittäminen laitteistolla on käytännössä vaikeaa. Koska reaktiokalorimetrillä pystytään määrittämään vain mittauksen aikana tapahtunut kokonaislämpömuutos, vaikuttavat mahdolliset faasimuutokset ja reaktorin lämpöhäviöt mittaustuloksiin. Näiden tekijöiden vaikutus on pyrittävä eliminoimaan tai niiden vaikutus on tunnettava tarkkaan, jos laitteella halutaan saada luotettavia reaktiolämpömittaustuloksia. Laitteiston mittaustarkkuus huononee huomattavasti, kun reaktorin lämpötila nousee yli 60 °C:een. Laitteistolla mitatut reaktiolämmöt poikkeavat huomattavasti vastaavista kirjallisuuden arvoista. Vedelle määritetyt ominaislämpökapasiteetit poikkeavat kirjallisuuden arvoista enintään 5 alle 90 °C:een lämpötilassa.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

When the popular initiative "against mass immigration" was accepted by the Swiss people and cantons on 9 February 2014, Ticino had by far the highest approval rate. The Italian-speaking canton thus once more confirmed its singular position, assumed since the 1990s, on popular votes regarding immigration and foreign policy. This seems to be indicative of wider crises and changes in both the economic and political spheres that have favoured the emergence of a political opposition between centre and periphery. The results of a survey among 1400 citizens of Ticino after the vote of 9 February confirm this. In essence, on top of the question of immigration, the vote was influenced by a fearful perception of Ticino as a "double periphery" vis-à-vis both Berne and Lombardy.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Segment poses and joint kinematics estimated from skin markers are highly affected by soft tissue artifact (STA) and its rigid motion component (STARM). While four marker-clusters could decrease the STA non-rigid motion during gait activity, other data, such as marker location or STARM patterns, would be crucial to compensate for STA in clinical gait analysis. The present study proposed 1) to devise a comprehensive average map illustrating the spatial distribution of STA for the lower limb during treadmill gait and 2) to analyze STARM from four marker-clusters assigned to areas extracted from spatial distribution. All experiments were realized using a stereophotogrammetric system to track the skin markers and a bi-plane fluoroscopic system to track the knee prosthesis. Computation of the spatial distribution of STA was realized on 19 subjects using 80 markers apposed on the lower limb. Three different areas were extracted from the distribution map of the thigh. The marker displacement reached a maximum of 24.9mm and 15.3mm in the proximal areas of thigh and shank, respectively. STARM was larger on thigh than the shank with RMS error in cluster orientations between 1.2° and 8.1°. The translation RMS errors were also large (3.0mm to 16.2mm). No marker-cluster correctly compensated for STARM. However, the coefficient of multiple correlations exhibited excellent scores between skin and bone kinematics, as well as for STARM between subjects. These correlations highlight dependencies between STARM and the kinematic components. This study provides new insights for modeling STARM for gait activity.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Body percussion using to the BAPNE method is a means of cognitive stimulation with multiple applications. The aim of this research is to assess their full potential as a source of therapy. The methodology used is theoretical in nature and makes use of a wide bibliography to find evidence for its therapeutic effect. In essence, body percussion can be seen to lead to improvements in three areas. the Physical, as it stimulates awareness of the body, control of movement and muscular strength, coordination and balance; the Mental, as it improves concentration, memory and perception; and finally Socio-affective, as it helps to build egalitarian relationships and leads to a decrease in anxiety in social interactions. This means of therapy has several different uses and it is targeted at different groups. In the present investigation we categorise them into five main groups: individuals with neurodegenerative diseases like Alzheimer's or Parkinson's disease; individuals with learning disorders such as dyslexia or ADHD; patients affected by diseases of the spinal cord, cranial neuropathies and trauma (Neurorehabilitation); and for the treatment of addictive behavior (addiction); and depressive disorders or anxiety disorders.After thorough analysis, we have found scientific evidence that the therapeutic body percussion using the BAPNE method improves the quality of life of patients and it is an important factor in stabilizing the development of different diseases.In addition, evidence involving certain biological indicators (in control and experimental groups, and through a pre-test and post-test) show its effect on levels of stress and anxiety (reduction of cortisol), as well as improvement of social relations as a result of working as a group (increased levels of oxytocin), and improvements seen in self-esteem and in a variety of personal aspects through the Aspects of Identity questionnaire.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Among all activities related to the management of science and technology in Brazil, program monitoring and evaluation is certainly one of the less developed and most needed. There are no universal methodologies that can be applied. In essence programs can be evaluated by relating their achievements to pre-established goals. A second strategy is to compare programs similar in nature, utilizing as reference common indicators. Finally programs can be evaluated by their socio-economic impact comparing investments to outcomes. All strategies mentioned require appropriate program design monitoring and expert independent evaluation. In Brazil as in many other countries including developed ones this activity is complicated by the fact that programs vary widely in their scope and goals. In Brazil program designs often do not specify clearly their purposes and output indicators, many are not monitored properly which makes evaluation difficult. Consequently science and technology programs are difficult to be compared to each other, and even evaluated on the basis of pre-established goals. In PADCT monitoring and evaluation proved to be the most challenging activities. Two lessons however were learnt. One is that the process of monitoring and evaluation has to be continuously exposed to criticism to be perfected; and the second is that the evaluation process must not be exhausted shortly after investments since translation of scientific knowledge into industrial applications may prove to be a lengthy process. In this exercise we certainly do not pretend to evaluate the QEQ subprogram but to organize some of the information produced by different sources related to this subject, including the PADCT administration. We use somewhat each strategy described: compare the outputs of the QEQ to predetermined proposed goals (particularly in PADCT II), compare the QEQ to other PADCT subprograms, and specify some outputs in terms of technological and industrial applications. Finally, we utilize this opportunity to discuss science and technology M&E in general and the complexity of developing this area in Brazil.