988 resultados para ENERGY PRODUCT


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background/Objectives: Reduced food intake, appetite loss and alteration of ghrelin and PYY(3-36) secretion have been suggested to have a function in the loss of body weight commonly observed after gastrectomy. The objective of this study was to investigate the circulating concentrations of ghrelin and PYY(3-36) and their relationships with food intake, appetite and resting energy expenditure (REE) after gastrectomy plus vagotomy. Subjects/Methods: Seven patients with total gastrectomy (TG), 14 with partial gastrectomy (PG) and 10 healthy controls were studied. Habitual food intake and REE was assessed; fasting and postprandial plasma total ghrelin, PYY(3-36) concentrations and appetite ratings were determined after ingestion of a liquid test meal. Results: Differently from PG and controls, fasting ghrelin correlated with REE, and a higher energy intake was observed in the TG group. Fasting plasma ghrelin concentrations were lower in TG compared with controls, and no ghrelin response to the meal was observed in either PG or TG. Fasting plasma PYY(3-36) concentrations were not different among the groups. There was an early and exaggerated postprandial rise in PYY(3-36) levels in both PG and TG groups, but not in controls. No effect of ghrelin or PYY(3-36) concentrations was observed on hunger, prospective consumption or fullness ratings. Conclusions: Total ghrelin and PYY(3-36) do not seem to be involved with appetite or energy intake regulation after gastrectomy plus vagotomy. Ghrelin secreted by sources other than stomach is likely to have a function in the long-term regulation of body weight after TG. European Journal of Clinical Nutrition (2010) 64, 845-852; doi: 10.1038/ejcn.2010.88; published online 19 May 2010

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives The methods currently available for the measurement of energy expenditure in patients, such as indirect calorimetry and double-labelled water, are expensive and are limited in Brazil to research projects. Thus, equations for the prediction of resting metabolic rate appear to be a viable alternative for clinical practice. However, there are no specific equations for the Brazilian population and few studies have been conducted on Brazilian women in the climacteric period using existing and commonly applied equations. On this basis, the objective of the present study was to investigate the concordance between the predictive equations most frequently used and indirect calorimetry for the measurement of resting metabolic rate. Methods We calculated the St. Laurent concordance correlation coefficient between the equations and resting metabolic rate calculated by indirect calorimetry in 46 climacteric women. Results The equation showing the best concordance was that of the FAO/WHO/UNU formula (0.63), which proved to be better than the Harris & Benedict equation (0.55) for the sample studied. Conclusions On the basis of the results of the present study, we conclude that the FAO/WHO/UNU formula can be used to predict better the resting metabolic rate of climacteric women. Further studies using more homogeneous and larger samples are needed to permit the use of the FAO/WHO/UNU formula for this population group with greater accuracy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Studies on children with cancer have suggested that energy expenditure may indeed be greater than predicted for healthy children. Nutritional assessment is important for intervention and for the prevention of complications associated with malnutrition. The present study aimed to describe the nutritional status, energy expenditure, and substrate utilization of children and adolescents with cancer compared to healthy children matched for age, sex, and body mass index. Subjects were evaluated by anthropometry, food intake pattern, and body composition analysis. Energy expenditure and substrate oxidation were measured by indirect calorimetry. Indirect calorimetry data, energy, and macronutrient intake, anthropometry, and body composition parameters showed no significant differences between groups. There was no evidence of increased energy expenditure or of a change in substrate utilization in children with cancer compared to the healthy group. The data regarding usual food consumption showed no significant differences between groups.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

There is an increasing interest about the use of stable isotopes for body composition analysis in pediatrics. To ensure the success of total body water analysis by the deuterium dilution method, it is fundamental to determine the equilibrium tune (plateau) of deuterium in the body fluid studied. Objectives: We report here the equilibration time of deuterium oxide in the saliva of newborns after oral intake of the isotope. Methods: Twenty healthy term newborn infants, 10 males and 10 females, were analyzed. Saliva was collected from each newborn before the oral administration of a 100 mg/kg dose of deuterium oxide (baseline sample) and then at 1-hour intervals for 5 hours after administration. Deuterium enrichment of saliva was determined by isotope ratio mass spectrometry according to the recommendations of the International Atomic Energy Agency. Results: The plateau time of deuterium in saliva occurred 3 hours after oral administration of the stable isotope. Conclusion: These data are essential for further studies on the body composition of newborn infants. To the best of our knowledge, this is the first study regarding the equilibration time of deuterium in the saliva of term newborns. JPGN 48:471-474, 2009.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nine ruminally cannulated cows fed different energy sources were used to evaluate an avian-derived polyclonal antibody preparation (PAP-MV) against the specific ruminal bacteria Streptococcus bovis, Fusobacterium necrophorum, Clostridium aminophilum, Peptostreptococcus anaerobius, and Clostridium stick-landii and monensin (MON) on ruminal fermentation patterns and in vivo digestibility. The experimental design was three 3 x 3 Latin squares distinguished by the main energy source in the diet [dry-ground corn grain (CG), high-moisture corn silage (HMCS), or citrus pulp (CiPu)]. Inside each Latin square, animals received one of the feed additives per period [none (CON), MON, or PAP-MV]. Dry matter intake and ruminal fermentation variables such as pH, total short-chain fatty acids (tSCFA), which included acetate, propionate, and butyrate, as well as lactic acid and NH(3)-N concentration were analyzed in this trial. Total tract DM apparent digestibility and its fractions were estimated using chromic oxide as an external marker. Each experimental period lasted 21 d. Ruminal fluid sampling was carried out on the last day of the period at 0, 2, 4, 6, 8, 10, and 12 h after the morning meal. Ruminal pH was higher (P = 0.006) 4 h postfeeding in MON and PAP-MV groups when compared with CON. Acetate: propionate ratio was greater in PAP-MV compared with MON across sampling times. Polyclonal antibodies did not alter (P > 0.05) tSCFA, molar proportion of acetate and butyrate, or lactic acid and NH(3)-N concentration. Ruminal pH was higher (P = 0.01), 4 h postfeeding in CiPu diets compared with CG and HMCS. There was no interaction between feed additive and energy source (P > 0.05) for any of the digestibility coefficients analyzed. Starch digestibility was less (P = 0.008) in PAP-MV when compared with CON and MON. In relation to energy sources, NDF digestibility was greater (P = 0.007) in CG and CiPu vs. the HMCS diet. The digestibility of ADF was greater (P = 0.002) in CiPu diets followed by CG and HMCS. Feeding PAP-MV or monensin altered ruminal fermentation patterns and digestive function in cows; however, those changes were independent of the main energy source of the diet.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, we consider solutions to the three-dimensional Schrodinger equation of the form psi(r) = u(r)/r, where u(0) not equal 0. The expectation value of the kinetic energy operator for such wavefunctions diverges. We show that it is possible to introduce a potential energy with an expectation value that also diverges, exactly cancelling the kinetic energy divergence. This renormalization procedure produces a self-adjoint Hamiltonian. We solve some problems with this new Hamiltonian to illustrate its usefulness.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Polymerization stress development results from the complex interplay of volumetric shrinkage, reaction kinetics, and viscoelastic properties. The objective of this study was to examine the relationships among volumetric shrinkage, degree of conversion, rate of polymerization (RPmax), and stress development for 2 model bis-GMA-based composites. Three irradiances were used 220, 400, or 600 mW/cm(2) - with exposure times adjusted to deliver the same radiant energy. Volumetric shrinkage was determined with a mercury dilatometer, degree of conversion and RPmax by differential scanning calorimetry (DSC), and polymerization stress with a low-compliance device (Sakaguchi et al., 2004b). Results indicated that polymerization reaction rate and shrinkage were not correlated. Irradiance was directly related to polymerization reaction rate and to stress development. The group with the highest stress/degree of conversion exhibited the lowest RPmax, so it can be assumed, within the limitations of this study, that the conversion was most closely related to stress development.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective. This study evaluated the degree of conversion (DC), maximum rate of cure (R(p)(max)), and polymerization stress (PS) developed by an experimental dental composite subjected to different irradiant energies (3,6,12, 24, or 48J/cm(2)) under constant irradiance (500 mw/cm(2)). Methods. DC and R(p)(max) were monitored for 10 min on the bottom surface of 2-mm thick disks and on 150-mu m thick films (representing the top of the specimen) using ATR-FTIR. PS was monitored for 10 min in 2-mm thick disks bonded to two glass rods (O = 5 mm) attached to a universal testing machine. One-way ANOVA/Tukey tests were used and differences in DC and R(p)(max) between top and bottom surfaces were examined using Student`s t-test. Statistical testing was performed at a pre-set alpha of 0.05. Results. For a given surface, DC showed differences among all groups, except at the top between 24 and 48 J/cm(2). R(p)(max) was similar among all groups at the same surface and statistically higher at the top surface. PS also showed significant differences among all groups. Data for 48 J/cm(2) were not obtained due to specimen failure at the glass/composite interface. Significance. Increases in irradiant exposure led to significant increases in DC and PS, but had no effect on R(p)(max) (c) 2008 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To investigate the effect of curing rate on softening in ethanol, degree of conversion, and wear of resin composites. Methods: With a given energy density and for each of two different light-curing units (QTH or LED), the curing rate was reduced by modulating the curing mode. Thus, the irradiation of resin composite specimens (Filtek Z250, Tetric Ceram, Esthet-X) was performed in a continuous curing mode and in a pulse-delay curing mode. Wallace hardness was used to determine the softening of resin composite after storage in ethanol. Degree of conversion was determined by infrared spectroscopy (FTIR). Wear was assessed by a three-body test. Data were submitted to Levene`s test, one and three-way ANOVA, and Tukey HSD test (alpha= 0.05). Results: Immersion in ethanol, curing mode, and material all had significant effects on Wallace hardness. After ethanol storage, resin composites exposed to the pulse-delay curing mode were softer than resin composites exposed to continuous cure (P< 0.0001). Tetric Ceram was the softest material followed by Esthet-X and Filtek Z250 (P< 0.001). Only the restorative material had a significant effect on degree of conversion (P< 0.001): Esthet-X had the lowest degree of conversion followed by Filtek Z250 and Tetric Ceram. Curing mode (P= 0.007) and material (P< 0.001) had significant effect on wear. Higher wear resulted from the pulse-delay curing mode when compared to continuous curing, and Filtek Z250 showed the lowest wear followed by Esthet-X and Tetric Ceram. (Am J Dent 2011;24:115-118).