871 resultados para Dyes in medical diagnosis


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective To assess the impact of exercise referral schemes on physical activity and health outcomes. Design Systematic review and meta-analysis. Data sources Medline, Embase, PsycINFO, Cochrane Library, ISI Web of Science, SPORTDiscus, and ongoing trial registries up to October 2009. We also checked study references. Study selection - Design: randomised controlled trials or non-randomised controlled (cluster or individual) studies published in peer review journals. - Population: sedentary individuals with or without medical diagnosis. - Exercise referral schemes defined as: clear referrals by primary care professionals to third party service providers to increase physical activity or exercise, physical activity or exercise programmes tailored to individuals, and initial assessment and monitoring throughout programmes. - Comparators: usual care, no intervention, or alternative exercise referral schemes. Results Eight randomised controlled trials met the inclusion criteria, comparing exercise referral schemes with usual care (six trials), alternative physical activity intervention (two), and an exercise referral scheme plus a self determination theory intervention (one). Compared with usual care, follow-up data for exercise referral schemes showed an increased number of participants who achieved 90-150 minutes of physical activity of at least moderate intensity per week (pooled relative risk 1.16, 95% confidence intervals 1.03 to 1.30) and a reduced level of depression (pooled standardised mean difference −0.82, −1.28 to −0.35). Evidence of a between group difference in physical activity of moderate or vigorous intensity or in other health outcomes was inconsistent at follow-up. We did not find any difference in outcomes between exercise referral schemes and the other two comparator groups. None of the included trials separately reported outcomes in individuals with specific medical diagnoses. Substantial heterogeneity in the quality and nature of the exercise referral schemes across studies might have contributed to the inconsistency in outcome findings. Conclusions Considerable uncertainty remains as to the effectiveness of exercise referral schemes for increasing physical activity, fitness, or health indicators, or whether they are an efficient use of resources for sedentary people with or without a medical diagnosis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Context: Tumor-induced osteomalacia (TIO) is a rarely diagnosed disorder presenting with bone pain, fractures, muscle weakness, and moderate-to-severe hypophosphatemia resulting from fibroblast growth factor 23-mediated renal phosphate wasting. Tumors secreting fibroblast growth factor 23 are often small and difficult to find with conventional imaging. Objective: We studied the utility of 68Ga-DOTA-octreotate (DOTATATE) somatostatin receptor positron emission tomography (PET)/computed tomography (CT) imaging in the diagnosis of TIO. Design and Setting: A multicenter case series was conducted at tertiary referral hospitals. Patients and Methods: Six patients with TIO diagnosed between 2003 and 2012 in Australia were referred for DOTATATE PET imaging. We reviewed the clinical history, biochemistry, imaging characteristics, histopathology, and clinical outcome of each patient. Results: Each case demonstrated delayed diagnosis despite severe symptoms. DOTATATE PET/CT imaging demonstrated high uptake and localized the tumor with confidence in each case. After surgical excision, there was resolution of clinical symptoms and serum phosphate, except in one patient who demonstrated residual disease on PET/CT. All tumors demonstrated high somatostatin receptor subtype 2 cell surface receptor expression using immunohistochemistry. Conclusions: In patients with TIO, DOTATATE PET/CT can successfully localize phosphaturic mesenchymal tumors and may be a practical first step in functional imaging for this disorder. Serum phosphate should be measured routinely in patients with unexplained muscle weakness, bone pain, or stress fractures to allow earlier diagnosis of TIO. - See more at: http://press.endocrine.org/doi/abs/10.1210/jc.2012-3642#sthash.eXD0CopL.dpuf

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Resumen Background: Nitric oxide can be measured at multiple flow rates to determine proximal (maximum airway nitric oxide flux; Jaw(NO)) and distal inflammation (alveolar nitric oxide concentration; CA(NO)). The main aim was to study the association among symptoms, lung function, proximal (maximum airway nitric oxide flux) and distal (alveolar nitric oxide concentration) airway inflammation in asthmatic children treated and not treated with inhaled glucocorticoids. Methods: A cross-sectional study with prospective data collection was carried out in a consecutive sample of girls and boys aged between 6 and 16 years with a medical diagnosis of asthma. Maximum airway nitric oxide flux and alveolar nitric oxide concentration were calculated according to the two-compartment model. In asthmatic patients, the asthma control questionnaire (CAN) was completed and forced spirometry was performed. In controls, differences between the sexes in alveolar nitric oxide concentration and maximum airway nitric oxide flux and their correlation with height were studied. The correlation among the fraction of exhaled NO at 50 ml/s (FENO50), CA(NO), Jaw(NO), forced expiratory volume in 1 second (FEV1) and the CAN questionnaire was measured and the degree of agreement regarding asthma control assessment was studied using Cohen's kappa. Results: We studied 162 children; 49 healthy (group 1), 23 asthmatic participants without treatment (group 2) and 80 asthmatic patients treated with inhaled corticosteroids (group 3). CA(NO) (ppb) was 2.2 (0.1-4.5), 3 (0.2-9.2) and 2.45 (0.1-24), respectively. Jaw(NO) (pl/s) was 516 (98.3-1470), 2356.67 (120-6110) and 1426 (156-11805), respectively. There was a strong association (r = 0.97) between FENO50 and Jaw(NO) and the degree of agreement was very good in group 2 and was good in group 3. There was no agreement or only slight agreement between the measures used to monitor asthma control (FEV1, CAN questionnaire, CA(NO) and Jaw(NO)). Conclusions: The results for CA(NO) and Jaw(NO) in controls were similar to those found in other reports. There was no agreement or only slight agreement among the three measure instruments analyzed to assess asthma control. In our sample, no additional information was provided by CA(NO) and Jaw(NO).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: This study identifies the stakeholders who have a role in medical device purchasing within the wider system of health-care delivery and reports on their particular challenges to promote patient safety during purchasing decisions. METHODS: Data was collected through observational work, participatory workshops, and semi-structured qualitative interviews, which were analyzed and coded. The study takes a systems-based and engineering design approach to the study. Five hospitals took part in this study, and the participants included maintenance, training, clinical end-users, finance, and risk departments. RESULTS: The main stakeholders for purchasing were identified to be staff from clinical engineering (Maintenance), device users (Clinical), device trainers (Training), and clinical governance for analyzing incidents involving devices (Risk). These stakeholders display varied characteristics in terms of interpretation of their own roles, competencies for selecting devices, awareness and use of resources for purchasing devices, and attitudes toward the purchasing process. The role of "clinical engineering" is seen by these stakeholders to be critical in mediating between training, technical, and financial stakeholders but not always recognized in practice. CONCLUSIONS: The findings show that many device purchasing decisions are tackled in isolation, which is not optimal for decisions requiring knowledge that is currently distributed among different people within different departments. The challenges expressed relate to the wider system of care and equipment management, calling for a more systemic view of purchasing for medical devices.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Y. Zhu, S. Williams and R. Zwiggelaar, 'Computer technology in detection and staging of prostate carcinoma: a review', Medical Image Analysis 10 (2), 178-199 (2006)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Histopathology is the clinical standard for tissue diagnosis. However, histopathology has several limitations including that it requires tissue processing, which can take 30 minutes or more, and requires a highly trained pathologist to diagnose the tissue. Additionally, the diagnosis is qualitative, and the lack of quantitation leads to possible observer-specific diagnosis. Taken together, it is difficult to diagnose tissue at the point of care using histopathology.

Several clinical situations could benefit from more rapid and automated histological processing, which could reduce the time and the number of steps required between obtaining a fresh tissue specimen and rendering a diagnosis. For example, there is need for rapid detection of residual cancer on the surface of tumor resection specimens during excisional surgeries, which is known as intraoperative tumor margin assessment. Additionally, rapid assessment of biopsy specimens at the point-of-care could enable clinicians to confirm that a suspicious lesion is successfully sampled, thus preventing an unnecessary repeat biopsy procedure. Rapid and low cost histological processing could also be potentially useful in settings lacking the human resources and equipment necessary to perform standard histologic assessment. Lastly, automated interpretation of tissue samples could potentially reduce inter-observer error, particularly in the diagnosis of borderline lesions.

To address these needs, high quality microscopic images of the tissue must be obtained in rapid timeframes, in order for a pathologic assessment to be useful for guiding the intervention. Optical microscopy is a powerful technique to obtain high-resolution images of tissue morphology in real-time at the point of care, without the need for tissue processing. In particular, a number of groups have combined fluorescence microscopy with vital fluorescent stains to visualize micro-anatomical features of thick (i.e. unsectioned or unprocessed) tissue. However, robust methods for segmentation and quantitative analysis of heterogeneous images are essential to enable automated diagnosis. Thus, the goal of this work was to obtain high resolution imaging of tissue morphology through employing fluorescence microscopy and vital fluorescent stains and to develop a quantitative strategy to segment and quantify tissue features in heterogeneous images, such as nuclei and the surrounding stroma, which will enable automated diagnosis of thick tissues.

To achieve these goals, three specific aims were proposed. The first aim was to develop an image processing method that can differentiate nuclei from background tissue heterogeneity and enable automated diagnosis of thick tissue at the point of care. A computational technique called sparse component analysis (SCA) was adapted to isolate features of interest, such as nuclei, from the background. SCA has been used previously in the image processing community for image compression, enhancement, and restoration, but has never been applied to separate distinct tissue types in a heterogeneous image. In combination with a high resolution fluorescence microendoscope (HRME) and a contrast agent acriflavine, the utility of this technique was demonstrated through imaging preclinical sarcoma tumor margins. Acriflavine localizes to the nuclei of cells where it reversibly associates with RNA and DNA. Additionally, acriflavine shows some affinity for collagen and muscle. SCA was adapted to isolate acriflavine positive features or APFs (which correspond to RNA and DNA) from background tissue heterogeneity. The circle transform (CT) was applied to the SCA output to quantify the size and density of overlapping APFs. The sensitivity of the SCA+CT approach to variations in APF size, density and background heterogeneity was demonstrated through simulations. Specifically, SCA+CT achieved the lowest errors for higher contrast ratios and larger APF sizes. When applied to tissue images of excised sarcoma margins, SCA+CT correctly isolated APFs and showed consistently increased density in tumor and tumor + muscle images compared to images containing muscle. Next, variables were quantified from images of resected primary sarcomas and used to optimize a multivariate model. The sensitivity and specificity for differentiating positive from negative ex vivo resected tumor margins was 82% and 75%. The utility of this approach was further tested by imaging the in vivo tumor cavities from 34 mice after resection of a sarcoma with local recurrence as a bench mark. When applied prospectively to images from the tumor cavity, the sensitivity and specificity for differentiating local recurrence was 78% and 82%. The results indicate that SCA+CT can accurately delineate APFs in heterogeneous tissue, which is essential to enable automated and rapid surveillance of tissue pathology.

Two primary challenges were identified in the work in aim 1. First, while SCA can be used to isolate features, such as APFs, from heterogeneous images, its performance is limited by the contrast between APFs and the background. Second, while it is feasible to create mosaics by scanning a sarcoma tumor bed in a mouse, which is on the order of 3-7 mm in any one dimension, it is not feasible to evaluate an entire human surgical margin. Thus, improvements to the microscopic imaging system were made to (1) improve image contrast through rejecting out-of-focus background fluorescence and to (2) increase the field of view (FOV) while maintaining the sub-cellular resolution needed for delineation of nuclei. To address these challenges, a technique called structured illumination microscopy (SIM) was employed in which the entire FOV is illuminated with a defined spatial pattern rather than scanning a focal spot, such as in confocal microscopy.

Thus, the second aim was to improve image contrast and increase the FOV through employing wide-field, non-contact structured illumination microscopy and optimize the segmentation algorithm for new imaging modality. Both image contrast and FOV were increased through the development of a wide-field fluorescence SIM system. Clear improvement in image contrast was seen in structured illumination images compared to uniform illumination images. Additionally, the FOV is over 13X larger than the fluorescence microendoscope used in aim 1. Initial segmentation results of SIM images revealed that SCA is unable to segment large numbers of APFs in the tumor images. Because the FOV of the SIM system is over 13X larger than the FOV of the fluorescence microendoscope, dense collections of APFs commonly seen in tumor images could no longer be sparsely represented, and the fundamental sparsity assumption associated with SCA was no longer met. Thus, an algorithm called maximally stable extremal regions (MSER) was investigated as an alternative approach for APF segmentation in SIM images. MSER was able to accurately segment large numbers of APFs in SIM images of tumor tissue. In addition to optimizing MSER for SIM image segmentation, an optimal frequency of the illumination pattern used in SIM was carefully selected because the image signal to noise ratio (SNR) is dependent on the grid frequency. A grid frequency of 31.7 mm-1 led to the highest SNR and lowest percent error associated with MSER segmentation.

Once MSER was optimized for SIM image segmentation and the optimal grid frequency was selected, a quantitative model was developed to diagnose mouse sarcoma tumor margins that were imaged ex vivo with SIM. Tumor margins were stained with acridine orange (AO) in aim 2 because AO was found to stain the sarcoma tissue more brightly than acriflavine. Both acriflavine and AO are intravital dyes, which have been shown to stain nuclei, skeletal muscle, and collagenous stroma. A tissue-type classification model was developed to differentiate localized regions (75x75 µm) of tumor from skeletal muscle and adipose tissue based on the MSER segmentation output. Specifically, a logistic regression model was used to classify each localized region. The logistic regression model yielded an output in terms of probability (0-100%) that tumor was located within each 75x75 µm region. The model performance was tested using a receiver operator characteristic (ROC) curve analysis that revealed 77% sensitivity and 81% specificity. For margin classification, the whole margin image was divided into localized regions and this tissue-type classification model was applied. In a subset of 6 margins (3 negative, 3 positive), it was shown that with a tumor probability threshold of 50%, 8% of all regions from negative margins exceeded this threshold, while over 17% of all regions exceeded the threshold in the positive margins. Thus, 8% of regions in negative margins were considered false positives. These false positive regions are likely due to the high density of APFs present in normal tissues, which clearly demonstrates a challenge in implementing this automatic algorithm based on AO staining alone.

Thus, the third aim was to improve the specificity of the diagnostic model through leveraging other sources of contrast. Modifications were made to the SIM system to enable fluorescence imaging at a variety of wavelengths. Specifically, the SIM system was modified to enabling imaging of red fluorescent protein (RFP) expressing sarcomas, which were used to delineate the location of tumor cells within each image. Initial analysis of AO stained panels confirmed that there was room for improvement in tumor detection, particularly in regards to false positive regions that were negative for RFP. One approach for improving the specificity of the diagnostic model was to investigate using a fluorophore that was more specific to staining tumor. Specifically, tetracycline was selected because it appeared to specifically stain freshly excised tumor tissue in a matter of minutes, and was non-toxic and stable in solution. Results indicated that tetracycline staining has promise for increasing the specificity of tumor detection in SIM images of a preclinical sarcoma model and further investigation is warranted.

In conclusion, this work presents the development of a combination of tools that is capable of automated segmentation and quantification of micro-anatomical images of thick tissue. When compared to the fluorescence microendoscope, wide-field multispectral fluorescence SIM imaging provided improved image contrast, a larger FOV with comparable resolution, and the ability to image a variety of fluorophores. MSER was an appropriate and rapid approach to segment dense collections of APFs from wide-field SIM images. Variables that reflect the morphology of the tissue, such as the density, size, and shape of nuclei and nucleoli, can be used to automatically diagnose SIM images. The clinical utility of SIM imaging and MSER segmentation to detect microscopic residual disease has been demonstrated by imaging excised preclinical sarcoma margins. Ultimately, this work demonstrates that fluorescence imaging of tissue micro-anatomy combined with a specialized algorithm for delineation and quantification of features is a means for rapid, non-destructive and automated detection of microscopic disease, which could improve cancer management in a variety of clinical scenarios.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Juvenile idiopathic arthritis reflects a group of clinically heterogeneous arthritides hallmarked by elevated concentrations of circulating immune complexes. In this study, the circulating immune complex proteome was examined to elucidate disease-associated proteins that are overexpressed in patients with an aggressive, and at times destructive, disease phenotype. To solve this proteome, circulating immune complexes were isolated from the sera of patients with chronic, erosive or early-onset, aggressive disease and from patients in medical remission or healthy controls subsequent to protein separation by 2-DE. Thirty-seven protein spots were overexpressed in the circulating immune complexes of the aggressive disease groups as compared to controls, 28 of which have been confidently identified to date. Proteolytic fragments of glyceraldehyde-3-phosphate dehydrogenase, serotransferrin, and a-1-antitrypsin have been identified among others. In total, these 28 putative disease-associated proteins most definitely contribute to immune complex formation and likely have a significant role in disease etiology and pathogenesis. Moreover, these proteins represent markers of aggressive disease, which could aid in diagnosis and management strategies, and potential therapeutic targets to prevent or control disease outcome. This is the first in-depth analysis of the circulating immune complex proteome in juvenile idiopathic arthritis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper reports on a study of the ways in which 54 older people in South Wales (UK) talk about the symptoms and causes of cold and influenza (flu). The study was designed to understand why older people might reject or accept the offer of seasonal flu vaccine, and in the course of the interviews respondents were also asked to express their views about the nature and causes of the two key illnesses. The latter are among the most common infections in human beings. In terms of the biomedical paradigm the common cold is caused by numerous respiratory viruses, whilst flu is caused by the influenza virus. Medical diagnosis is usually made on clinical grounds without laboratory confirmation. Symptoms of flu include sudden onset of fever and cough, and colds are characterized by sneezing, sore throat, and runny nose, but in practice the symptoms often overlap. In this study we examine the degree by which the views of lay people with respect to both diagnosis and epidemiology diverge with that which is evident in biomedical discourse. Our results indicate that whilst most of the identified symptoms are common to lay and professional people, the former integrate symptoms into a markedly different observational frame from the latter. And as far as causation is concerned it is clear that lay people emphasize the role of 'resistance' and 'immunity' at least as much as 'infection' in accounting for the onset of colds and flu. The data are analyzed using novel methods that focus on the co-occurrence of concepts and are displayed as semantic networks. As well as reporting on its findings the authors draw out some implications of the study for social scientific and policy discussions concerning lay diagnosis, lay expertise and the concept of an expert patient.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In light-skinned populations, the incidence of cutaneous melanoma is highest in summer and lowest in winter. We analyzed the seasonal variation of melanoma incidence in Northern Ireland from 1984 to 2006 according to the Breslow thickness and body site. We also reviewed earlier studies on seasonal variation in the diagnosis of melanoma. Two-thirds of melanomas in women (2028 cases) and one-third of melanomas in men (1230 cases) were diagnosed on the limbs. In both sexes, pronounced seasonal variations were observed in the incidence of invasive melanomas less than 2mm arising on the limbs. These seasonal variations were mainly noticeable in women of all ages, to a lesser degree in men aged below 50 years, and not in men aged above 50 years. No seasonal variation was observed for melanomas less than 2mm arising on the trunk or the head and neck nor for melanomas 2mm thickness or more, irrespective of the age, sex, and body site. Seasonal variations of thin melanomas were less noticeable in men because of the axial predominance of melanoma occurrence in this sex. The review of 15 earlier studies found by a systematic search of Medline supported the likelihood of our findings. This analysis suggests that ultraviolet radiation has a short-term promotional effect on melanocytes or nevocytes of the limbs, and is not associated with progression from thin to thick melanoma. Melanoma Res 21:144-151 (C) 2011 Wolters Kluwer Health vertical bar Lippincott Williams & Wilkins.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this study was to identify trends in the diagnosis of carcinoma in situ (CIS) of the breast in the United Kingdom (UK) and the Republic of Ireland (ROI) and to examine the impact of mammography. Data on cases of newly diagnosed CIS of the breast and mode of detection (screen detected or not) were obtained, where available, from regional cancer registries between 1990 and 2007. Age-standardised diagnosis rates for the UK and the ROI, and regional screen detected diagnosis rates were compared by calculating the annual percentage change (APC) over time. The APC of the diagnosis rate amongst women aged 50-64 years (original screening age group) showed a significant 5.9% increase in the UK (1990-2007) and 11.5% increase in the ROI (1994-2007). The rate of diagnosis (50-64 years) stabilized in the UK between 2005 and 2007 and was substantially higher than in other western populations with national screening programmes. The APC of the diagnosis rate amongst those aged 65-69 years showed a significant 12.4% increase in the UK (1990-2007) and 10.3% increase in the ROI (1994-2007). amongst women aged 50-74 years in the UK, approximately 4,300 cases of CIS (˜90% ductal carcinoma in situ) were diagnosed in 2007. Our analyses have shown that screen detected CIS contributed primarily to the increase in diagnosis of CIS of the breast. The high diagnosis rate of screen detected CIS of the breast underlines the need for further research into lesion and patient characteristics that are related to progression of CIS to invasive disease to better target treatment. © 2012 Springer Science+Business Media, LLC.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In a vault on the outskirts of Paris, a cylinder of platinum-iridium sits in a safe under three layers of glass. It is the kilogram, kept by the Bureau International des Poids et Mesures (BIPM), which is the international home of metrology. Metrology is the science of measurement, and it is of fundamental importance to us all. It is essential for trade, commerce, navigation, transport, communication, surveying, engineering, and construction. It is essential for medical diagnosis and treatment, health and safety, food and consumer protection, and for preserving the environment—e.g., measuring ozone in the atmosphere. Many of these applications are of particular relevance to chemistry and thus to IUPAC. In all these activities we need to make measurements reliably—to an appropriate and known level of uncertainty. The financial implications of metrology are enormous. In the United States, for example, some 15% of the gross domestic product is spent on healthcare, involving reliable quantitative measurements for both diagnosis and treatment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A series of the most common chelators used in magnetic resonance imaging ( MRI) and in radiopharmaceuticals for medical diagnosis and tumour therapy, H(4)dota, H(4)teta, H(8)dotp and H(8)tetp, is examined from a chemical point of view. Differences between 12- and 14-membered tetraazamacrocyclic derivatives with methylcarboxylate and methylphosphonate pendant arms and their chelates with divalent first-series transition metal and trivalent lanthanide ions are discussed on the basis of their thermodynamic stability constants, X- ray structures and theoretical studies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Virtual Reality (VR) is widely used in visualizing medical datasets. This interest has emerged due to the usefulness of its techniques and features. Such features include immersion, collaboration, and interactivity. In a medical visualization context, immersion is important, because it allows users to interact directly and closelywith detailed structures in medical datasets. Collaboration on the other hand is beneficial, because it gives medical practitioners the chance to share their expertise and offer feedback and advice in a more effective and intuitive approach. Interactivity is crucial in medical visualization and simulation systems, because responsiveand instantaneous actions are key attributes in applications, such as surgical simulations. In this paper we present a case study that investigates the use of VR in a collaborative networked CAVE environment from a medical volumetric visualization perspective. The study will present a networked CAVE application, which has been built to visualize and interact with volumetric datasets. We will summarize the advantages of such an application and the potential benefits of our system. We also will describe the aspects related to this application area and the relevant issues of such implementations.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Since their inception, Twitter and related microblogging systems have provided a rich source of information for researchers and have attracted interest in their affordances and use. Since 2009 PubMed has included 123 journal articles on medicine and Twitter, but no overview exists as to how the field uses Twitter in research. // Objective: This paper aims to identify published work relating to Twitter indexed by PubMed, and then to classify it. This classification will provide a framework in which future researchers will be able to position their work, and to provide an understanding of the current reach of research using Twitter in medical disciplines. Limiting the study to papers indexed by PubMed ensures the work provides a reproducible benchmark. // Methods: Papers, indexed by PubMed, on Twitter and related topics were identified and reviewed. The papers were then qualitatively classified based on the paper’s title and abstract to determine their focus. The work that was Twitter focused was studied in detail to determine what data, if any, it was based on, and from this a categorization of the data set size used in the studies was developed. Using open coded content analysis additional important categories were also identified, relating to the primary methodology, domain and aspect. // Results: As of 2012, PubMed comprises more than 21 million citations from biomedical literature, and from these a corpus of 134 potentially Twitter related papers were identified, eleven of which were subsequently found not to be relevant. There were no papers prior to 2009 relating to microblogging, a term first used in 2006. Of the remaining 123 papers which mentioned Twitter, thirty were focussed on Twitter (the others referring to it tangentially). The early Twitter focussed papers introduced the topic and highlighted the potential, not carrying out any form of data analysis. The majority of published papers used analytic techniques to sort through thousands, if not millions, of individual tweets, often depending on automated tools to do so. Our analysis demonstrates that researchers are starting to use knowledge discovery methods and data mining techniques to understand vast quantities of tweets: the study of Twitter is becoming quantitative research. // Conclusions: This work is to the best of our knowledge the first overview study of medical related research based on Twitter and related microblogging. We have used five dimensions to categorise published medical related research on Twitter. This classification provides a framework within which researchers studying development and use of Twitter within medical related research, and those undertaking comparative studies of research relating to Twitter in the area of medicine and beyond, can position and ground their work.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The performance of modular home made capillary electrophoresis equipment with spectrophotometric detection, at a visible region by means of a miniaturized linear charge coupled device, was evaluated for the determination of four food dyes. This system presents a simple but efficient home made cell detection scheme. A computer program that converts the spectral data after each run into the electropherograms was developed to evaluate the analytical parameters. The dyes selected for analytical evaluation of the system were Brilliant Blue FCF, Fast Green FCF, Sunset Yellow FCF, and Amaranth. Separation was carried out in a 29cm length and 75 mu m I.D fused silica capillary, using 10mmolL-1 borate buffer at pH 9, with separation voltage of 7.5kV. The detection limits for the dyes were between 0.3 and 1.5mgL-1 and the method presented adequate linearity over the ranges studied, with correlation coefficients greater than 0.99. The method was applied for determination and quantification of these dyes in fruit juices and candies.