369 resultados para Dinamômetro hidráulico


Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work presents an experimental investigation of thermal hydraulic performance of the nanofluid composed by graphene nanoparticles dispersed in a mixture of water and ethylene glycol at a ratio of 70:30% by volume. The tests were carried out under forced convection inside a circular tube with uniform heat flux on the wall for the laminar-turbulent transition regime. The mass flow rate ranged from 40 to 70 g/s corresponding to Reynolds numbers between 3000 and 7500. The heat flux was maintained constant at values of 11, 16 and 21 kW/m², as well as the inlet temperature of 15, 20 and 25°C. Three samples were produced with the nanofluid volumetric concentration of 0.05%, 0.10% and 0.15%. Thermophysical properties were experimentaly measured for all samples that were critically compared and discussed with theoretical models most commonly used in the literature. Initially, experiments with distilled water confirmed the validity of the experimental equipment for the thermo-hydraulic tests. Therefore, nanofluid samples that showed the highest thermal conductivity, corresponding to the volumetric concentrations of 0.15% and 0.10%, were subjected to the tests. The thermal-hydraulic performance for both samples was unsatisfactory. The heat transfer coefficients for convection of nanofluids reduced 21% in average, for the sample with = 0.15% and 26% and for =0.10%. The pressure drop of the samples was higher than the base fluid. Finally, the pressure drop and heat transfer coefficient by convection of both samples were also compared to theoretical models. The models used for pressure drop showed an excellent agreement with experimental results, which is remarkable considering the transitional flow.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Grande parte da energia contida no combustível consumido por um motor de combustão interna é desperdiçada sob forma de calor, através do sistema de refrigeração do motor, do sistema de recirculação dos gases de escape e principalmente através dos gases de escape. Daí o interesse no estudo de sistemas que permitem o aproveitamento dessa energia residual dos veículos automóveis. Este trabalho centra-se no estudo de sistemas de aproveitamento da energia térmica contida nos gases de escape dos veículos automóveis, sendo o objetivo principal o estudo do permutador de calor que será utilizado para recuperação da energia térmica. Existem vários tipos de permutadores, na sua escolha entram fatores como as características dos fluidos de trabalho envolvidos, o custo, facilidade de manutenção, a aplicação. Para o caso deste estudo selecionou-se um permutador de carcaça e tubos e um permutador de tubos concêntricos. Uma vez que a seleção e otimização de um permutador de calor implica a minimização da perda de carga dos gases de escape e a maximização da eficiência térmica do sistema, numa primeira fase selecionou-se a geometria mais adequada. Em seguida fez-se uma comparação de diferentes modelos de cálculo da perda de carga e analisou-se o desempenho termo hidráulico do permutador. Por fim realizou-se um estudo paramétrico para verificar a influência dos parâmetros de construção (número de tubos, diâmetro e comprimento dos tubos).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

As paredes de alvenaria não-resistentes têm sido, ao longo do tempo, amplamente utilizadas em fachadas, principalmente como material de enchimento. Este tipo de paredes detêm um papel de elevada importância em sistemas complexos como são os edifícios, uma vez que, separam o interior do ambiente exterior desenrolando um papel chave no desempenho dos edifícios, bem como no conforto dos seus utilizadores. Numa tentativa de aumentar a eficiência energética dos edifícios, vários países têm vindo a utilizar paredes duplas de alvenaria, a fim de criar caixas de ar ou espaços para colocar materiais de isolamento. No entanto, se este tipo de construção não for bem aplicado pode conduzir a patologias ou até mesmo ao colapso das paredes para fora do plano, particularmente devido a forças extremas como os sismos. Esta dissertação tem como objetivo apresentar uma campanha experimental que foi desenvolvida, a fim de investigar a influência do grampeamento em paredes duplas de alvenaria quando submetidas a cargas de compressão. Durante o estudo foram construídos diferentes provetes de paredes duplas de alvenaria onde foram aplicados diferentes tipos e quantidades de grampos. Para além disso, os grampos foram colocados em diferentes posições nas paredes, levando a uma quantidade significativa de variáveis. As cargas axiais aplicadas nos provetes, com o uso de um macaco hidráulico, serviram para averiguar e avaliar o número ideal e posição dos grampos contribuindo, portanto, para entender o cuidado necessário na construção de paredes duplas de alvenaria.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BRUNO, S. S. ; SOUSA, M. B. C. . Modulação pela progesterona da sensibilidade dolorosa a estímulos mecânicos e isquêmicos em mulheres saudáveis e jovens. RBGO. Revista Brasileira de Ginecologia e Obstetrícia , v. 30, p. 306-311, 2008

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Nos dias de hoje a sociedade exige níveis qualitativos de vida cada vez mais elevados, o que torna prioritária a conceção de sistemas eficientes, não poluidores, económicos e diversificados que permitam uma gestão integrada e racionalizada de recursos tão escasso como é o da água e da energia. Em sistemas de abastecimento de água, o uso de válvulas redutoras de pressão (VRP) visa a uniformização e controlo de pressões, promovendo uma perda de carga localizada que dissipa a energia hidráulica presente através da redução dos valores de pressão a jusante. Estas são fundamentais no controlo e redução de pressão. A utilização de microturbinas é uma alternativa sustentável para o controle de pressão e, simultaneamente, para a produção de energia elétrica. Trata-se de um método de mitigação para controlar as perdas referidas convergindo no âmbito da eficiência energética. Na perspetiva de promover um aproveitamento de energia nas redes de abastecimento de água, o presente trabalho sugere a substituição de válvulas redutoras de pressão (VRP) por microturbinas. Desse modo, apresenta-se um método automático de seleção de (i) local para implementação e (ii) projeto de microturbinas para sistemas de abastecimento de água. Para a modelação do funcionamento dos sistemas hidráulicos recorre-se ao simulador hidráulico EPANET. Esta ferramenta possibilita avaliação de caudais e pressões em todos os pontos da rede durante um determinado intervalo de tempo. A metodologia desenvolvida permite selecionar o local ideal no sistema hidráulico através de uma análise de cada secção conduta-nó escolhendo-se a melhor opção baseada na produção de energia. Depois da localização procede-se à seleção do tipo de turbina (Kaplan, Francis, Pelton e Cross-flow) que vai depender das características do sistema hidráulico. Na etapa seguinte apresenta-se os resultados obtidos pela turbina nomeadamente a produção de energia elétrica anual, o investimento necessário, o tempo de retorno e a rentabilização ao final de um período de 25 anos. Na última etapa da metodologia, de forma avaliar o comportamento do sistema final, realiza-se uma nova simulação da rede mas tendo em conta a introdução da microturbina no local. Apresentam-se alguns casos de estudo que validam a ferramenta desenvolvida. A metodologia desenvolvida é comparada com um caso de estudo real. Em ambos os exemplos simulados a metodologia aplicada permite obter soluções com ganhos energéticos significativos associados ao sistema. Apenas num dos exemplos se observaram que a implementação da microturbina no sistema hidráulico não seria economicamente rentável.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BRUNO, S. S. ; SOUSA, M. B. C. . Modulação pela progesterona da sensibilidade dolorosa a estímulos mecânicos e isquêmicos em mulheres saudáveis e jovens. RBGO. Revista Brasileira de Ginecologia e Obstetrícia , v. 30, p. 306-311, 2008

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Un dispositivo para medir el comportamiento de cimentaciones ante un esfuerzo de tracción o de compresión, que comprende: un bastidor (1, 2); un cilindro hidráulico (3) montado en el bastidor de modo que pueda pivotar alrededor de al menos un eje; medios de acoplamiento mecánico del cilindro hidráulico (3) a la cimentación; medios de medir el esfuerzo ejercido por el cilindro hidráulico sobre la cimentación; medios de medir el desplazamiento de la cimentación bajo el esfuerzo; y medios de alimentación hidráulica del cilindro hidráulico.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

El sistema que se propone tiene como objetivo permitir realizar los ensayos de hundimiento, corte por torsión y penetración, muy empleados en los estudios de locomoción extraviaria, trabajando con el suelo sin alterar. Se trata de un sistema acoplable a cualquier tractor agrícola comercial, que permite realizar varios ensayos para un mismo estacionamiento y que utiliza como fuente de energía para el funcionamiento de las partes móviles el sistema hidráulico del tractor, o bien un sistema hidráulico independiente accionado por la toma de fuerza.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introdução – O treino dos músculos inspiratórios (TMI) surge como uma intervenção importante na população com doença pulmonar obstrutiva crónica (DPOC), mas com interesse crescente na população saudável. No entanto, não existem estudos suficientes que comprovem se o treino dos músculos inspiratórios se traduz também numa melhoria da capacidade aeróbia objetivada no consumo de oxigénio (VO2). Assim, a relação entre o TMI e os seus resultados no indivíduo saudável carece de estudo que comprove os efeitos reais do treino. Considerou-se, pelo anteriormente exposto, pertinente a realização de um estudo de investigação na população saudável que permitisse avaliar em que medida um programa de TMI induz alterações na força muscular inspiratória e na capacidade aeróbia. Métodos e análise – A amostra foi constituída por indivíduos saudáveis (n=19) com idades compreendidas entre os 18 e 21 anos que realizam exercício físico regularmente (≥3 vezes por semana ou ≥4h por semana). A capacidade aeróbia foi estimada através do Teste de Ebbeling e a força dos músculos inspiratórios foi medida pela pressão inspiratória máxima (PIM) obtida num dinamómetro específico (MicroRPM®), em dois momentos distintos (pré e pós-treino). A referida amostra foi dividida aleatoriamente em dois grupos (n=9 no grupo experimental e n=10 no grupo de controlo). O grupo experimental (GE) foi submetido a um TMI de alta intensidade (≥50% Pi,máx), enquanto o grupo de controlo (GC) não foi sujeito a qualquer intervenção. O TMI foi realizado através do PowerBreathe Classic® Level 1 e Level 2, que fornece uma pressão consistente e específica para a força muscular inspiratória, independentemente do fluxo inspiratório do indivíduo. Conclusões – Após o treino verificou-se um aumento de 37% na PIM do GE, enquanto o GC apresentou uma melhoria de 7%. Na comparação intragrupos, ambos os grupos aumentaram significativamente tanto a PIM como o VO2 (p<0,05). Já na comparação intergrupos, a diferença foi significativa para a PIM (p=0,000), mas não para o VO2. Serão necessários mais estudos no sentido de concluir e avaliar em que condições o TMI produz alterações na capacidade aeróbia.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

El presente trabajo de culminación de estudio comprende la descripción de las distintas etapas que se realizó el proyecto de Diseño e instalación de riego localizado y aspersión en la finca El Plantel, propiedad de la Universidad Nacional Agraria (UNA). En la primera etapa se realizó la perforación del pozo, se utilizó un equipo de perforación marca Bucyrus-Erie” por el método de Percusión y Tipo de Broca “California”, en un periodo de 35 días, acumulando un total de 420 horas máquina-hombres para obtener una profundidad de 500 pies. Se encontró el nivel estático del agua a los 170 pies y manto acuífero a los 175 pies de profundidad. Se instaló un equipo de bombeo sumergible de 100 HP, 460 voltios, acoplado a un motor FRANKLIN eléctrico. Se realizaron cuatro pruebas de aforamiento con un nivel estático inicial de 169.5 pies con un caudal de descarga libre de 650 galones por minuto y dos pruebas de recuperación del nivel dinámico. La segunda etapa está comprendida por el levantamiento topográfico planimétrico y altimétrico para trazar las curvas a nivel del área comprendida para el posterior diseño de sistemas de riego. Tercera etapa en donde se realizó la lotificación del área, según los diferentes cultivos propuestos y en la última etapa se realizó el diseño hidráulico y geométrico de los distintos sistemas definiendo las dimensiones de tuberías, espaciamiento, accesorios, válvulas, aspersores, goteros, cintas, distancia entre aspersores y caudales por unidad de riego y presión de trabajo.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The release of nitrogen compounds in water bodies can result in many environmental problems, so treat wastewater, such as sewage in order to remove not only organic matter but also nitrogen has been studied a few decades. From the above, the objective of this study was to evaluate the performance of a structured bed reactor, continuous flow, with recirculation, in removing organic matter and nitrogen present in wastewater under different cycles of intermittent aeration (AI) and to evaluate the influence of these cycles in the development of nitrifying bacteria (Oxidizing Bacteria Ammonia - BOA and Bacteria Oxidizing Nitrite - BON) and denitrifying (DESN) adhered (Support Material - MS) and suspension (Effluent - EF and sludge - LD). The reactor used has usable volume of 9.4 L. As support materials (MS) polyurethane foam was used, cut and fixed in PVC rods. 3 were worked aeration phases (AE) and non-aeration (AN) at different stage: Stage 1 (4 h EA / AN 2H); Stage 2 (2H EA / AN 1 h) and Phase 3 (2H EA / AN 2 h). During all hydraulic detention time phases was kept at 16 h and the effluent recirculated at a rate of 3 times the inflow. Were analyzed: pH, total alkalinity, temperature, chemical oxygen demand (COD), Biochemical Oxygen Demand (BOD), nitrogen Kjeldhl Total (NKT), ammonia-N-N-NH4+, nitrito-N-NO2+andnitrato-NO3-. The concentration of BOA, BON and DESN was determined using the number More Provável.gSSV-1 (NMP.gSSV-1). In phase 1 the percentage removal NTK N-NH4+ and NT was 76±10%, 70±21% and 67±10% respectively. In Phase 2 80±15% of removel NKT, 86±15% of N-NH4+ e 68±9% of removel NT e na Fase 3 de 58±20%, 72±28% and 41±6% of NKT, N-NH4+ of NT, respectively. The denitrification efficiency in stage 3 was over 70%, indicating that occurred in the reactor the process of simultaneous nitrification and denitrification (NDS). DQOT the removal percentages were 88 ± 4% in Phase 1, 94 ± 7 in Phase 2 and 90± 11% in Phase 3. The multivariate ANOVA applied to NMP.gSSV-1, it indicated that there was significant (F: 20,2, p <0,01) between the analyzed concentration of organisms AI in different cycles, but the differences between NMP.gSSV-1 depends not only isolated factors but of which means, and phase groups being analysis. From the results it is concluded that the working system is efficient in terms of nitrogen removal and organic matter, and that the stage with the highest availability of Dissolved Oxygen (DO) and C/N ratio (Step 2), was the one obtained the lower concentrations of organic matter effluents and N-NH4+. Hinted that there was a significant difference between the concentration (NMP.100mL-1) of the analyzed organizations (BOA, BON and DESN), but this difference does not depend on factors alone but of which means (MS, EF or LD), stages (1, 2 or 3) and groups (BOA, BON and DESN) is being considered.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O presente trabalho de fim de mestrado caracteriza-se pela ampliação e remodelação das redes de abastecimento de águas e drenagem de águas residuais domésticas e pluviais do Hotel Terra Nostra nas Furnas em Ponta Delgada em fase de licenciamento. Este empreendimento é constituído por 2 alas (Ala Deco e Ala Jardim) constituídas por 3 pisos na Ala Deco e 4 pisos na Ala Jardim. A remodelação da rede será efectuada somente onde a rede existente já está bastante degradada ou com um abastecimento deficiente. A sua ampliação vem fazer face ao aumento do número de instalações sanitárias do empreendimento e da cozinha da Ala Deco. O objectivo desta intervenção vem no sentido de melhorar o funcionamento da rede, resolver os problemas existentes com o desgaste da mesma e proporcionar melhores níveis de conforto no seu desempenho. Neste sentido foi realizado um estudo sobre todo o sistema hidráulico do hote, tanto de abastecimento como de drenagem de águas residuais domésticas e pluviais, tendo como apoio para a realização do mesmo a legislação em vigor bem como alguns manuais de hidráulica. Desta forma o referente trabalho vem mostrar toda a solução adoptada para fazer face às deficiências encontradas no sistema bem como a respectiva ampliação das instalações do mesmo.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work aims to develop optical sensors for temperature monitoring in hydroelectric power plant heat exchangers. The proposed sensors are based on the Fiber Bragg Gratings technology. First of all, a prototype with three sensors inscribed in a same fiber was developed. This fiber was then fixed to a conventional Pt100 sensor rod and inserted in a thermowell. The ensemble was then calibrated in a workbench, presenting a maximum combined uncertainty of 2,06 °C. The sensor was installed in one of the heat exchangers of the Salto Osório’s hydroelectric power plant. This power plant is situated in the Iguaçu river, at the Paraná state. Despite the satisfactory results, the sensor was improved to a second version. In this, fifteen optical Bragg sensors were inscribed in a same fiber. The fixation with a conventional sensor was no longer necessary, because the first version results comproved the efficiency and response time in comparison to a conventional sensor. For this reason, it was decided to position the fiber inside a stainless steel rod, due to his low thermal expansion coefficient and high corrosion immunity. The utilization of fifteen fiber Bragg gratings aims to improve the sensor spatial resolution. Therefore, measurements every ten centimeters with respect to the heat exchanger’s height are possible. This provides the generation of a thermal map of the heat exchanger’s surface, which can be used for determination of possible points of obstruction in the hydraulic circuit of the heat exchanger. The heat exchanger’s obstruction in hydroelectric power plants usually occur by bio-fouling, and has direct influence in the generator’s cooling system efficiency. The obtained results have demonstrated the feasibility in application of the optical sensors technology in hydroelectric power plants.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Nesta tese foi demonstrado o potencial de produção de carboidratos por Aphanothece microscopica Nägeli cultivada no efluente oriundo de uma indústria de laticínios. Para tanto, o trabalho é composto de quatro artigos que objetivaram avaliar a produção de carboidratos em função da temperatura, inóculo e razões C/N e N/P do elfluente, bem como a possibilidade de reúso da água residuária. Foram utilizadas temperaturas de (10, 20 e 30ºC) e inóculo (100, 200 e 300 mg.L-1). A melhor condição indicada foi quando utilizou-se a temperatura de 30°C e 200 mg.L-1 de inóculo. Na sequência, considerando a temperatura e a concentração celular selecionada, foi estudada a influência das razões C/N e N/P na produção de carboidratos. Para tal, C/N (20, 40 e 60) e N/P (5, 10 e 15) na produção de carboidratos extracelulares foram avaliadas em cultivos a 30°C, tendo como inóculo 200 mg.L-1. Os melhores resultados obtidos, foram quando foi utilizado C/N 60 e N/P 10. Uma vez definidas as melhores condições de produção de carboidratos, foi estudado o processo de separação de biomassa do meio de cultivo, a partir dos coagulantes FeCl3, Al2(SO4)3 e tanino. O efeito dos coagulantes na separação da biomassa foram estudados, quanto ao pH (6,0, 7,0 e 8,0) e concentração de coagulantes (50, 300 e 550 mg.L-1), utilizando como parâmetro de medida, a eficiência de remoção de DQO, turbidez e sólidos suspensos (SS). Os resultados demonstraram que as concentrações de coagulantes influenciaram significativamente ao nível de significância de 5 %, na separação da biomassa, com eficiência significativa na remoção da DQO, turbidez e SS. A melhor condição avaliada foi a que utilizou tanino na concentração de 300 mg.L-1 e pH 7,0, o que resultou em uma água residuária com remoção média de 96 % da turbidez, com potencial de ser reutilizada. Por fim, foi realizada a identificação de carboidratos gerados por Aphanothece microscopica Nägeli. Os resultados evidenciaram uma biomassa com até 33,5 % de carboidratos totais, perfazendo uma fração de carboidratos extracelulares, na fase estacionária de crescimento celular, de aproximadamente 25 % e 8 % os carboidratos da parede celular. Ficou demonstrado ainda que a composição dos carboidratos extracelulares do microorganismo em estudo é constituído por mono e dissacarídeos perfazendo concentrações na ordem de 12,88 % de glicose, 3,54 % de rafinose, 3,43 % sacarose, 2,13 % de frutose e 2,45 % de ribose. Ficou demonstrado o potencial de produção de carboidratos por Aphanothece microscopica Nägeli quando cultivada no efluente da indústria de laticínios.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A Refinaria de Matosinhos é um dos complexos industriais da Galp Energia. A sua estação de tratamento de águas residuais industriais (ETARI) – designada internamente por Unidade 7000 – é composta por quatro tratamentos: o pré-tratamento, o tratamento físico-químico, o tratamento biológico e o pós-tratamento. Dada a interligação existente, é fundamental a otimização de cada um dos tratamentos. Este trabalho teve como objetivos a identificação dos problemas e/ou possibilidades de melhoria do pré-tratamento, tratamento físico-químico e pós-tratamento e principalmente a otimização do tratamento biológico da ETARI. No pré-tratamento verificou-se que a separação de óleos e lamas não era eficaz uma vez que se formam emulsões destas duas fases. Como solução, sugeriu-se a adição de agentes desemulsionantes, que se revelou economicamente inviável. Assim, sugeriu-se como alternativa o recurso a técnicas de tratamento da emulsão gerada, tais como a extração com solvente, centrifugação, ultrassons e micro-ondas. No tratamento físico-químico constatou-se que o controlo da unidade de saturação de ar na água era feito com base na análise visual dos operadores, o que pode conduzir a condições de operação afastadas das ótimas para este tratamento. Assim, sugeriu-se a realização de um estudo de otimização desta unidade com vista à determinação da razão ar/sólidos ótima para este efluente. Para além disto, constatou-se, ainda, que os consumos de coagulante aumentaram cerca de -- % no último ano, pelo que foi sugerido o estudo da viabilidade do processo de eletrocoagulação como substituto do sistema de coagulação existente. No pós-tratamento identificou-se o processo de lavagem dos filtros como sendo a etapa com possibilidade de ser otimizada. Através de um estudo preliminar concluiu-se que a lavagem contínua de um filtro por cada turno melhorava o desempenho dos mesmos. Constatou-se, ainda, que a introdução de ar comprimido na água de lavagem promove uma maior remoção de detritos do leito de areia, no entanto esta prática parece influenciar negativamente o desempenho dos filtros. No caso do tratamento biológico, identificaram-se problemas ao nível do tempo de retenção hidráulico do tratamento biológico II, que apresentou elevada variabilidade. Apesar de identificado concluiu-se que este problema era de difícil solução. Verificou-se, também, que o oxigénio dissolvido não era monitorizado, pelo que se sugeriu a instalação de uma sonda de oxigénio dissolvido numa zona de baixa turbulência do tanque de arejamento. Concluiu-se que o oxigénio era distribuído de forma homogénea por todo o tanque de arejamento e tentou-se identificar quais os fatores que influenciariam este parâmetro, no entanto, dada a elevada variabilidade do efluente e das condições de tratamento, tal não foi possível. Constatou-se, também, que o doseamento de fosfato para o tratamento biológico II era pouco eficiente já Otimização dos sistemas biológicos e melhorias nos tratamentos da ETARI da Refinaria de Matosinhos que em -- % dos dias se verificaram níveis baixos de fosfato no licor misto (< - mg/L). Foi, por isso, proposta a alteração do atual sistema de doseamento por gravidade para um sistema de bomba doseadora. Para além disso verificou-se que os consumos deste nutriente aumentaram significativamente no último ano (cerca de --%), situação que se constatou estar relacionada com um aumento da população microbiana para este período. Foi possível relacionar-se o aparecimento frequente de lamas à superfície dos decantadores secundários com incrementos repentinos de condutividade, pelo que se sugeriu o armazenamento do efluente nas bacias de tempestade, nestas situações. Verificou-se que a remoção de azoto era praticamente ineficaz uma vez que a conversão de azoto amoniacal em nitratos foi muito baixa. Assim, sugeriu-se o recurso à técnica de bio-augmentação ou a transformação do sistema de lamas ativadas num sistema bietápico. Por fim, constatou-se que a temperatura do efluente à entrada da ETARI apresenta valores bastante elevados para o tratamento biológico (aproximadamente de --º C) pelo que se sugeriu a instalação de uma sonda de temperatura no tanque de arejamento de modo a controlar de forma mais eficaz a temperatura do licor misto. Ainda no que diz respeito ao tratamento biológico, foi possível desenvolver-se um conjunto de ferramentas que visaram o funcionamento otimizado deste tratamento. Nesse sentido, foram apresentadas várias sugestões de melhoria: a utilização do índice volumétrico de lamas como indicador da qualidade das lamas em alternativa à percentagem de lamas; foi desenvolvido um conjunto de fluxogramas para a orientação dos operadores de exterior na resolução de problemas; foi criada uma “janela de operação” que pretende ser um guia de apoio à operação; foi ainda proposta a monitorização frequente da idade das lamas e da razão alimento/microrganismo.