357 resultados para Dilation
Resumo:
PURPOSE: To assess the impact of human crystalline lens opacification and yellowing, similar to that observed in patients with cataracts, on retinal vessel blood oxygen saturation measurements using custom manufactured soft contact lenses. METHODS: Ten healthy, non-smoking individuals were enrolled for this study. All subjects underwent digital blood pressure measurements, assessment of non-contact intra-ocular pressure, pupil dilation and retinal vessel oximetry using dual-wavelength photography (Oximetry Module, Imedos Systems). To simulate lens changes, three different contact lenses were inserted, one to simulate opacities followed by two more lenses to simulate different levels of lens yellowing (Cantor & Nissel). RESULTS: The measurements obtained showed an opposite change in arterial and venous oxygen saturation and optical density ratio across conditions, resulting in a statistically significant difference in arterial minus venous oxygen saturation value (p = 0.003). However, this difference was only significant for the 'opacity' condition but not for the 'yellowing' conditions. CONCLUSION: Lenticular changes such as cataracts can impact on spectrophotometric analysis in particular dual-wavelength retinal vessel oximetry. Hence, lenticular assessment and cataract grading should be considered when assessing elderly individuals and patient groups developing cataract earlier in life such as those suffering from diabetes mellitus.
Resumo:
This paper presents a novel algorithm for medial surfaces extraction that is based on the density-corrected Hamiltonian analysis of Torsello and Hancock [1]. In order to cope with the exponential growth of the number of voxels, we compute a first coarse discretization of the mesh which is iteratively refined until a desired resolution is achieved. The refinement criterion relies on the analysis of the momentum field, where only the voxels with a suitable value of the divergence are exploded to a lower level of the hierarchy. In order to compensate for the discretization errors incurred at the coarser levels, a dilation procedure is added at the end of each iteration. Finally we design a simple alignment procedure to correct the displacement of the extracted skeleton with respect to the true underlying medial surface. We evaluate the proposed approach with an extensive series of qualitative and quantitative experiments. © 2013 Elsevier Inc. All rights reserved.
Resumo:
2000 Mathematics Subject Classification: 47A65, 45S78.
Resumo:
We consider the Hamiltonian H of a 3D spinless non-relativistic quantum particle subject to parallel constant magnetic and non-constant electric field. The operator H has infinitely many eigenvalues of infinite multiplicity embedded in its continuous spectrum. We perturb H by appropriate scalar potentials V and investigate the transformation of these embedded eigenvalues into resonances. First, we assume that the electric potentials are dilation-analytic with respect to the variable along the magnetic field, and obtain an asymptotic expansion of the resonances as the coupling constant ϰ of the perturbation tends to zero. Further, under the assumption that the Fermi Golden Rule holds true, we deduce estimates for the time evolution of the resonance states with and without analyticity assumptions; in the second case we obtain these results as a corollary of suitable Mourre estimates and a recent article of Cattaneo, Graf and Hunziker [11]. Next, we describe sets of perturbations V for which the Fermi Golden Rule is valid at each embedded eigenvalue of H; these sets turn out to be dense in various suitable topologies. Finally, we assume that V decays fast enough at infinity and is of definite sign, introduce the Krein spectral shift function for the operator pair (H+V, H), and study its singularities at the energies which coincide with eigenvalues of infinite multiplicity of the unperturbed operator H.
Resumo:
Purpose: To to evaluate the benefit of bilinear and linear fitting to characterize the retinal vessel dilation to flicker light stimulation for the purpose of risk stratification in cardiovascular disease. Methods: Forty-five patients (15 with coronary artery disease (CAD), 15 with Diabetes Mellitus (DM) and 15 with CAD and DM) all underwent contact tonometry, digital blood pressure measurement, fundus photography, retinal vessel oximetry, static retinal vessel analysis and continous retinal diameter assessment using the retinal vessel analyser (and flicker light provocation). In addition we measured blood glucose (HbA1c) and keratinin levels in DM patients. Results: With increased severity of cardiovascular disease a more linear reaction profile of retinal arteriolar diameter to flicker light provocation can be observed. Conclusion: Absolute values of vessel dilation provide only limited information on the state of retinal arteriolar dilatory response to flicker light. The approach of bilinear fitting takes into account the immediate response to flicker light provocation as well as the maintained dilatory capacity during prolonged stimulation. Individuals with cardiovascular disease however show a largely linear reaction profile indicating an impairment of the initial rapid dilatory response as usually observed in healty individuals
Resumo:
A protocol with repeated stimulation cycles should be analyzed stepwise, in that each stimulation is evaluated, and a reaction pattern is identified. No two subjects will react identically, in that dilation and recovery times can vary; however, this is not reason enough to abandon a multiple stimulation cycle with fixed recovery and stimulation times. Furthermore, it enables us to examine and determine the range in which a normal subject will be placed and can then be compared to different pathophysiological states (i.e., smokers and different diseases). The purpose of our paper was to highlight the importance of evaluating these different cycles and the danger of false interpretation when averaging results. There are many different ways of evaluating dilatory responses and elasticity, but each of them must be carefully evaluated and should not be overaveraged, which can result in a loss of sensitivity and specificity.
Resumo:
Purpose: To determine the response of retinal vessels to differing durations of flicker light (FL) sitmulation. Methods: We recorded retinal arterial and venous vessel dilation to 12.5 Hz flicker light provocation (Retinal Vessel Analyzer, Imedos Systems) of varying duration (5, 7, 10 and 20 seconds) in twelve healthy young individuals (age range 26-45 yrs). All participants underwent a full ocular examination including intraocular pressure and blood pressure measurements. Results: Maximum dilation (MD) did not show a significant dependence on flicker duration in arteries whereas maximum constriction (MC) did. However, in veins MD significantly increased with flicker duration. Approximately 80-90% of MD in arteries is reached within 10 seconds of flicker light stimulation. Conclusions: The vast majority of arterial dilatory capacity is reached within 10 seconds of flicker light stimulation even though venous dilation continues strongly. Since the MC of arteries shows a significant dependence on flicker duration measurements at two different durations can provide more information about the retinal vascular system than at a single flicker duration alone.
Resumo:
Purpose: To test the hypothesis of a significant relationship between systemic markers of renal and vascular function (processes linked to cardiovascular disease and its development) and retinal microvascular function in diabetes and/or cardiovascular disease.Methods: Ocular microcirculatory function was measured in 116 patients with diabetes and/or cardiovascular disease using static and continuous retinal vessel responses to three cycles of flickering light. Endothelial function was evaluated by von Willebrand factor (vWf), endothelial microparticles and soluble E selectin, renal function by serum creatinine, creatinine clearance and estimated glomerular filtration rate (eGFR). HbA1c was used as a control index.Results: Central retinal vein equivalence and venous maximum dilation to flicker were linked to HbA1c (both p<0.05). Arterial reaction time was linked to serum creatinine (p=0.036) and eGFR (p=0.039), venous reaction time was linked to creatinine clearance (p=0.018). Creatinine clearance and eGFR were linked to arterial maximum dilatation (p<0.001 and p=0.003 respectively) and the dilatation amplitude (p=0.038 and p=0.048 respectively) responses in the third flicker cycle. Of venous responses to the first flicker cycle, HbA1c was linked to the maximum dilation response (p=0.004) and dilatation amplitude (p=0.017), vWf was linked to the maximum constriction response (p=0.016), and creatinine clearance to the baseline diameter fluctuation (p=0.029). In the second flicker cycle, dilatation amplitude was linked to serum creatinine (p=0.022). Conclusions: Several retinal blood vessel responses to flickering light are linked to glycaemia and renal function, but only one index is linked to endothelial function. Renal function must be considered when interpreting retinal vessel responses.
Resumo:
Steam injection is an oil recovery method accomplished by introducing steam directly into the oil well to the reservoir. The steam causes dilation of the casing, which, after reduction in temperature, tends to return to the initial dimensions: causing the formation of cracks in the cement and loss of hydraulic isolation.. In this context, the type of the SBR latex is used to improve the flexibility of the cement matrix by reducing the amount of fatigue failure. To prevent these failures, the mechanical resistance parameters should be carefully adjusted to well conditions. This work aims to study the mechanical behavior of cement slurry systems additivated with SBR latex for cementing oil wells subject to steam injection. Through the central composite factorial design was studied the behavior of the compressive strength by varying the density of the paste between 1.75 g /cm³ (14.6 lb/ Gal) and 1.89 g/cm³ (15,8lb / Gal), curing time between 4 days and 28 days and concentration of SBR Latex between 0 L / m³ and 534.722 L / m³ (0 gpc and 4 gpc). The results showed that increasing the concentration of SBR latex, within the given ranges, there was a decreased compression resistance and elastic modulus by increasing the elastic deformability of the slurry. From the results it can determine best slurries formulation conditions in oil well cementing operations subject to steam injection.
Resumo:
Steam injection is an oil recovery method accomplished by introducing steam directly into the oil well to the reservoir. The steam causes dilation of the casing, which, after reduction in temperature, tends to return to the initial dimensions: causing the formation of cracks in the cement and loss of hydraulic isolation.. In this context, the type of the SBR latex is used to improve the flexibility of the cement matrix by reducing the amount of fatigue failure. To prevent these failures, the mechanical resistance parameters should be carefully adjusted to well conditions. This work aims to study the mechanical behavior of cement slurry systems additivated with SBR latex for cementing oil wells subject to steam injection. Through the central composite factorial design was studied the behavior of the compressive strength by varying the density of the paste between 1.75 g /cm³ (14.6 lb/ Gal) and 1.89 g/cm³ (15,8lb / Gal), curing time between 4 days and 28 days and concentration of SBR Latex between 0 L / m³ and 534.722 L / m³ (0 gpc and 4 gpc). The results showed that increasing the concentration of SBR latex, within the given ranges, there was a decreased compression resistance and elastic modulus by increasing the elastic deformability of the slurry. From the results it can determine best slurries formulation conditions in oil well cementing operations subject to steam injection.
Resumo:
L’insuffisance cardiaque (IC) est associée à un taux de mortalité et d’hospitalisations élevé causant un fardeau économique important. Les deux causes majeures de décès de l’IC sont les arythmies ventriculaires létales et les sidérations myocardiques. Il est maintenant reconnu que l’angiotensine II (ANGII) est l'un des principaux médiateurs de l’IC. Ses effets délétères découlent de l’activation du récepteur de type 1 de l’ANGII (AT1) et entraînent le développement d’hypertrophie. Toutefois, son rôle dans la genèse d’arythmies demeure incompris. De ce fait, l'étude des mécanismes électriques et contractiles sous-jacents aux effets pathologiques de l’ANGII s’avère essentielle afin de mieux comprendre et soigner cette pathologie. Il est souvent perçu que les femmes sont protégées envers les maladies cardiovasculaires. Cependant, le nombre total de femmes décédant d’IC est plus grand que le nombre d’hommes. Également, l’impact des facteurs de risque diffère entre chaque sexe. Ces différences existent, mais les mécanismes sous-jacents sont encore peu connus. De plus, les femmes reçoivent fréquemment un diagnostic ou un traitement inapproprié en raison d’un manque d’information sur les différences entre les sexes dans la manifestation d’une pathologie. Ce manque de données peut découler du fait que les sujets de sexe féminin sont souvent sous-représentés dans les essais cliniques ou la recherche fondamentale ce qui a grandement limité l’avancement de nos connaissances sur ~50 % de la population. Ainsi, il semble plus que nécessaire d’approfondir notre compréhension des différences entre les sexes, notamment dans la progression de l’IC. L’utilisation d’un modèle de souris transgénique surexprimant le récepteur AT1 (souris AT1R) a permis d’étudier les changements électriques, structurels et contractiles avant et après le développement d’hypertrophie. Premièrement, chez les souris AT1R mâles, un ralentissement de la conduction ventriculaire a été observé indépendamment de l’hypertrophie. Ce résultat était expliqué par une réduction de la densité du courant Na+, mais pas de l’expression du canal. Ensuite, le rôle des protéines kinases C (PKC) dans la régulation du canal Na+ par l’ANGII a été exploré. Les évidences ont suggéré que la PKCα était responsable de la modulation de la diminution du courant Na+ chez les souris AT1R mâles et dans les cardiomyocytes humains dérivés de cellules souches induites pluripotentes (hiPSC-CM) en réponse à un traitement chronique à l’ANGII. Ensuite, les différences entre les sexes ont été comparées chez la souris AT1R. Une plus grande mortalité a été constatée chez les femelles AT1R suggérant qu’elles sont plus sensibles à la surexpression de AT1R. Le remodelage électrique ventriculaire a donc été comparé entre les souris AT1R des deux sexes. Les courants ioniques étaient altérés de façon similaire entre les sexes excluant ainsi leur implication dans la mortalité plus élevée chez les femelles. Ensuite, l’homéostasie calcique et la fonction cardiaque ont été étudiées. Il a été démontré que les femelles développaient une hypertrophie et une dilatation ventriculaire plus sévère que les mâles. De plus, les femelles AT1R avaient de petits transitoires calciques, une extrusion du Ca2+ plus lente ainsi qu’une augmentation de la fréquence des étincelles Ca2+ pouvant participer à des troubles contractiles et à la venue de post-dépolarisations précoces. En conclusion, l’ANGII est impliquée dans le remodelage électrique, structurel et calcique associé à l'émergence de l’IC. De surcroît, ces altérations affectent plus sévèrement les femelles soulignant la présence de différences entre les sexes dans le développement de l’IC.
Resumo:
The aim of this present study was to investigate if overweight individuals exhibit signs of vascular dysfunction associated with a high risk for cardiovascular disease (CVD). One hundred lean and 100 overweight participants were recruited for the present study. Retinal microvascular function was assessed using the Dynamic Retinal Vessel Analyser (DVA), and systemic macrovascular function by means of flow-mediated dilation (FMD). Investigations also included body composition, carotid intimal-media thickness (c-IMT), ambulatory blood pressure monitoring (BP), fasting plasma glucose, triglycerides (TG), cholesterol levels (HDL-C and LDL-C), and plasma von Willebrand factor (vWF). Overweight individuals presented with higher right and left c-IMT (p = 0.005 and p = 0.002, respectively), average 24-h BP values (all p <0.001), plasma glucose (p = 0.008), TG (p = 0.003), TG: HDL-C ratio (p = 0.010), and vWF levels (p = 0.004). Moreover, overweight individuals showed lower retinal arterial microvascular dilation (p = 0.039) and baseline-corrected flicker (bFR) responses (p = 0.022), as well as, prolonged dilation reaction time (RT, p = 0.047). These observations emphasise the importance of vascular screening and consideration of preventive interventions to decrease vascular risk in all individuals with adiposity above normal range.
Resumo:
PURPOSE: Increased arterial stiffness is a common finding in patients with end-stage renal disease. Following creation of an arteriovenous fistula (AVF), appropriate dilation of the feeding artery must occur to facilitate AVF maturation. Arterial stiffness may impair the arterial dilation required to facilitate AVF development and contribute to subsequent failure to mature (FTM). The aim of this pilot study was to investigate the association between measurements of central and peripheral arterial stiffness, and AVF FTM.
METHODS: Patients undergoing AVF creation in a single centre (Belfast City Hospital, UK) between January and December 2015 were invited to have their carotid-femoral pulse wave velocity (PWV), brachial-radial PWV and augmentation index (AI) measured prior to AVF creation. Subsequent AVF outcomes were identified.
RESULTS: Fifty-nine patients who had an AVF procedure were included in the final analysis (mean age 62 years); 50.8% had diabetes mellitus. The mean pre-operative arterial diameter for all AVFs was 3.9 mm. Average values for carotid-femoral PWV were 9.5 m/s, brachial-radial PWV 7.7 m/s and AI 25.6%. Using logistic regression, these arterial stiffness parameters did not predict AVF FTM: carotid-femoral PWV (P = 0.20), brachial-radial PWV (P = 0.13), AI (P = 0.50).
CONCLUSIONS: This is the largest study to date exploring the association between arterial stiffness and AVF FTM. The measured central and peripheral arterial stiffness parameters were not associated with AVF FTM. Further research is needed to define if non-invasive arterial physiological measurements would be clinically useful in the prediction of AVF FTM.
Resumo:
The pharmacological management of early pregnancy loss reduced substantially the need for dilation and curettage. However, prognostic markers of successful outcome were not established. Thus the major purpose of this study was to determine the sensitivity and specificity of the uterine artery pulsatility (PI) and resistance (RI) indices to detect early pregnancy loss patients requiring dilation and curettage after unsuccessful management.
Resumo:
Tracheal diverticulum is a rare benign entity. Tracheobronchomegaly (TBM), also known as Mounier-Kuhn syndrome, is a rare disorder characterized by marked dilation of the trachea and main bronchi, associated with thinning or atrophy of the elastic tissue. Because of the weakened trachea and increased intraluminal pressure related to chronic cough, some patients may develop mucosal herniation leading to tracheal diverticulosis. We report the case of a patient with TBM with a huge tracheal diverticulum, diagnosed by bronchoscopy and computed tomography with three-dimensional reconstruction. To our knowledge this is the largest tracheal diameter described in a patient affected by this syndrome.