977 resultados para Detection, Optimisation, Assessment, Highway


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Malnutrition occurs in 30 - 60 % of hospitalized medical or surgical patients, as well as out-patients. Serious consequences at various levels were observed. Malnutrition influences negatively the quality of life, the immune system, muscle strength and worsens the prognosis of the patient. Interventions for a rapid and simple identification and effective treatment of this condition are essential and cost saving. Screening tools for the identification of patients at nutritional risk are very useful in daily practice. The systematic identification of patients with potential or apparent malnutrition is very important allowing an effective nutritional treatment at an early time. The medical team in charge should perform the nutritional risk screening and the following assessment to recognize the nutritional problems and to solve them in an interdisciplinary and -professional team.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conservation and monitoring of forest biodiversity requires reliable information about forest structure and composition at multiple spatial scales. However, detailed data about forest habitat characteristics across large areas are often incomplete due to difficulties associated with field sampling methods. To overcome this limitation we employed a nationally available light detection and ranging (LiDAR) remote sensing dataset to develop variables describing forest landscape structure across a large environmental gradient in Switzerland. Using a model species indicative of structurally rich mountain forests (hazel grouse Bonasa bonasia), we tested the potential of such variables to predict species occurrence and evaluated the additional benefit of LiDAR data when used in combination with traditional, sample plot-based field variables. We calibrated boosted regression trees (BRT) models for both variable sets separately and in combination, and compared the models’ accuracies. While both field-based and LiDAR models performed well, combining the two data sources improved the accuracy of the species’ habitat model. The variables retained from the two datasets held different types of information: field variables mostly quantified food resources and cover in the field and shrub layer, LiDAR variables characterized heterogeneity of vegetation structure which correlated with field variables describing the understory and ground vegetation. When combined with data on forest vegetation composition from field surveys, LiDAR provides valuable complementary information for encompassing species niches more comprehensively. Thus, LiDAR bridges the gap between precise, locally restricted field-data and coarse digital land cover information by reliably identifying habitat structure and quality across large areas.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND Small ruminant lentiviruses escaping efficient serological detection are still circulating in Swiss goats in spite of a long eradication campaign that essentially eliminated clinical cases of caprine arthritis encephalitis in the country. This strongly suggests that the circulating viruses are avirulent for goats.To test this hypothesis, we isolated circulating viruses from naturally infected animals and tested the in vitro and in vivo characteristics of these field isolates. METHODS Viruses were isolated from primary macrophage cultures. The presence of lentiviruses in the culture supernatants was monitored by reverse transcriptase assay. Isolates were passaged in different cells and their cytopathogenic effects monitored by microscopy. Proviral load was quantified by real-time PCR using customized primer and probes. Statistical analysis comprised Analysis of Variance and Bonferroni Multiple Comparison Test. RESULTS The isolated viruses belonged to the small ruminant lentiviruses A4 subtype that appears to be prominent in Switzerland. The 4 isolates replicated very efficiently in macrophages, displaying heterogeneous phenotypes, with two isolates showing a pronounced cytopathogenicity for these cells. By contrast, all 4 isolates had a poor replication capacity in goat and sheep fibroblasts. The proviral loads in the peripheral blood and, in particular, in the mammary gland were surprisingly high compared to previous observations. Nevertheless, these viruses appear to be of low virulence for goats except for the mammary gland were histopathological changes were observed. CONCLUSIONS Small ruminant lentiviruses continue to circulate in Switzerland despite a long and expensive caprine arthritis encephalitis virus eradication campaign. We isolated 4 of these lentiviruses and confirmed their phylogenetic association with the prominent A4 subtype. The pathological and histopathological analysis of the infected animals supported the hypothesis that these A4 viruses are of low pathogenicity for goats, with, however, a caveat about the potentially detrimental effects on the mammary gland. Moreover, the high proviral load detected indicates that the immune system of the animals cannot control the infection and this, combined with the phenotypic plasticity observed in vitro, strongly argues in favour of a continuous and precise monitoring of these SRLV to avoid the risk of jeopardizing a long eradication campaign.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE The purpose of this study was to investigate the feasibility of microdose CT using a comparable dose as for conventional chest radiographs in two planes including dual-energy subtraction for lung nodule assessment. MATERIALS AND METHODS We investigated 65 chest phantoms with 141 lung nodules, using an anthropomorphic chest phantom with artificial lung nodules. Microdose CT parameters were 80 kV and 6 mAs, with pitch of 2.2. Iterative reconstruction algorithms and an integrated circuit detector system (Stellar, Siemens Healthcare) were applied for maximum dose reduction. Maximum intensity projections (MIPs) were reconstructed. Chest radiographs were acquired in two projections with bone suppression. Four blinded radiologists interpreted the images in random order. RESULTS A soft-tissue CT kernel (I30f) delivered better sensitivities in a pilot study than a hard kernel (I70f), with respective mean (SD) sensitivities of 91.1% ± 2.2% versus 85.6% ± 5.6% (p = 0.041). Nodule size was measured accurately for all kernels. Mean clustered nodule sensitivity with chest radiography was 45.7% ± 8.1% (with bone suppression, 46.1% ± 8%; p = 0.94); for microdose CT, nodule sensitivity was 83.6% ± 9% without MIP (with additional MIP, 92.5% ± 6%; p < 10(-3)). Individual sensitivities of microdose CT for readers 1, 2, 3, and 4 were 84.3%, 90.7%, 68.6%, and 45.0%, respectively. Sensitivities with chest radiography for readers 1, 2, 3, and 4 were 42.9%, 58.6%, 36.4%, and 90.7%, respectively. In the per-phantom analysis, respective sensitivities of microdose CT versus chest radiography were 96.2% and 75% (p < 10(-6)). The effective dose for chest radiography including dual-energy subtraction was 0.242 mSv; for microdose CT, the applied dose was 0.1323 mSv. CONCLUSION Microdose CT is better than the combination of chest radiography and dual-energy subtraction for the detection of solid nodules between 5 and 12 mm at a lower dose level of 0.13 mSv. Soft-tissue kernels allow better sensitivities. These preliminary results indicate that microdose CT has the potential to replace conventional chest radiography for lung nodule detection.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to determine the reliability of the conditioned pain modulation (CPM) paradigm assessed by an objective electrophysiological method, the nociceptive withdrawal reflex (NWR), and psychophysical measures, using hypothetical sample sizes for future studies as analytical goals. Thirty-four healthy volunteers participated in two identical experimental sessions, separated by 1 to 3 weeks. In each session, the cold pressor test (CPT) was used to induce CPM, and the NWR thresholds, electrical pain detection thresholds and pain intensity ratings after suprathreshold electrical stimulation were assessed before and during CPT. CPM was consistently detected by all methods, and the electrophysiological measures did not introduce additional variation to the assessment. In particular, 99% of the trials resulted in higher NWR thresholds during CPT, with an average increase of 3.4 mA (p<0.001). Similarly, 96% of the trials resulted in higher electrical pain detection thresholds during CPT, with an average increase of 2.2 mA (p<0.001). Pain intensity ratings after suprathreshold electrical stimulation were reduced during CPT in 84% of the trials, displaying an average decrease of 1.5 points in a numeric rating scale (p<0.001). Under these experimental conditions, CPM reliability was acceptable for all assessment methods in terms of sample sizes for potential experiments. The presented results are encouraging with regards to the use of the CPM as an assessment tool in experimental and clinical pain. Trial registration: Clinical Trials.gov NCT01636440.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND Alcohol-related disorders are common, expensive in their course, and often underdiagnosed. To facilitate early diagnosis and therapy of alcohol-related disorders and to prevent later complications, questionnaires and biomarkers are useful. METHODS Indirect state markers like gamma-glutamyl-transpeptidase, mean corpuscular volume, and carbohydrate deficient transferrin are influenced by age, gender, various substances, and nonalcohol-related illnesses, and do not cover the entire timeline for alcohol consumption. Ethanol (EtOH) metabolites, such as ethyl glucuronide, ethyl sulfate, phosphatidylethanol, and fatty acid ethyl esters have gained enormous interest in the last decades as they are detectable after EtOH intake. RESULTS For each biomarker, pharmacological characteristics, detection methods in different body tissues, sensitivity/specificity values, cutoff values, time frames of detection, and general limitations are presented. Another focus of the review is the use of the markers in special clinical and forensic samples. CONCLUSIONS Depending on the biological material used for analysis, ethanol metabolites can be applied in different settings such as assessment of alcohol intake, screening, prevention, diagnosis, and therapy of alcohol use disorders.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND In a high proportion of patients with favorable outcome after aneurysmal subarachnoid hemorrhage (aSAH), neuropsychological deficits, depression, anxiety, and fatigue are responsible for the inability to return to their regular premorbid life and pursue their professional careers. These problems often remain unrecognized, as no recommendations concerning a standardized comprehensive assessment have yet found entry into clinical routines. METHODS To establish a nationwide standard concerning a comprehensive assessment after aSAH, representatives of all neuropsychological and neurosurgical departments of those eight Swiss centers treating acute aSAH have agreed on a common protocol. In addition, a battery of questionnaires and neuropsychological tests was selected, optimally suited to the deficits found most prevalent in aSAH patients that was available in different languages and standardized. RESULTS We propose a baseline inpatient neuropsychological screening using the Montreal Cognitive Assessment (MoCA) between days 14 and 28 after aSAH. In an outpatient setting at 3 and 12 months after bleeding, we recommend a neuropsychological examination, testing all relevant domains including attention, speed of information processing, executive functions, verbal and visual learning/memory, language, visuo-perceptual abilities, and premorbid intelligence. In addition, a detailed assessment capturing anxiety, depression, fatigue, symptoms of frontal lobe affection, and quality of life should be performed. CONCLUSIONS This standardized neuropsychological assessment will lead to a more comprehensive assessment of the patient, facilitate the detection and subsequent treatment of previously unrecognized but relevant impairments, and help to determine the incidence, characteristics, modifiable risk factors, and the clinical course of these impairments after aSAH.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The use of infrared thermography for the identification of lameness in cattle has increased in recent years largely because of its non-invasive properties, ease of automation and continued cost reductions. Thermography can be used to identify and determine thermal abnormalities in animals by characterizing an increase or decrease in the surface temperature of their skin. The variation in superficial thermal patterns resulting from changes in blood flow in particular can be used to detect inflammation or injury associated with conditions such as foot lesions. Thermography has been used not only as a diagnostic tool, but also to evaluate routine farm management. Since 2000, 14 peer reviewed papers which discuss the assessment of thermography to identify and manage lameness in cattle have been published. There was a large difference in thermography performance in these reported studies. However, thermography was demonstrated to have utility for the detection of contralateral temperature difference and maximum foot temperature on areas of interest. Also apparent in these publications was that a controlled environment is an important issue that should be considered before image scanning.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

AIMS Skeletal muscle wasting affects 20% of patients with chronic heart failure and has serious implications for their activities of daily living. Assessment of muscle wasting is technically challenging. C-terminal agrin-fragment (CAF), a breakdown product of the synaptically located protein agrin, has shown early promise as biomarker of muscle wasting. We sought to investigate the diagnostic properties of CAF in muscle wasting among patients with heart failure. METHODS AND RESULTS We assessed serum CAF levels in 196 patients who participated in the Studies Investigating Co-morbidities Aggravating Heart Failure (SICA-HF). Muscle wasting was identified using dual-energy X-ray absorptiometry (DEXA) in 38 patients (19.4%). Patients with muscle wasting demonstrated higher CAF values than those without (125.1 ± 59.5 pmol/L vs. 103.8 ± 42.9 pmol/L, P = 0.01). Using receiver operating characteristics (ROC), we calculated the optimal CAF value to identify patients with muscle wasting as >87.5 pmol/L, which had a sensitivity of 78.9% and a specificity of 43.7%. The area under the ROC curve was 0.63 (95% confidence interval 0.56-0.70). Using simple regression, we found that serum CAF was associated with handgrip (R = - 0.17, P = 0.03) and quadriceps strength (R = - 0.31, P < 0.0001), peak oxygen consumption (R = - 0.5, P < 0.0001), 6-min walk distance (R = - 0.32, P < 0.0001), and gait speed (R = - 0.2, P = 0.001), as well as with parameters of kidney and liver function, iron metabolism and storage. CONCLUSION CAF shows good sensitivity for the detection of skeletal muscle wasting in patients with heart failure. Its assessment may be useful to identify patients who should undergo additional testing, such as detailed body composition analysis. As no other biomarker is currently available, further investigation is warranted.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

INTRODUCTION Left ventricular thrombus (LVT) formation may worsen the post-infarct outcome as a result of thromboembolic events. It also complicates the use of modern antiplatelet regimens, which are not compatible with long-term oral anticoagulation. The knowledge of the incidence of LVT may therefore be of importance to guide antiplatelet and antithrombotic therapy after acute myocardial infarction (AMI). METHODS In 177 patients with large, mainly anterior AMI, standard cardiac magnetic resonance imaging (CMR) including cine and late gadolinium enhancement (LGE) imaging was performed shortly after AMI as per protocol. CMR images were analysed at an independent core laboratory blinded to the clinical data. Transthoracic echocardiography (TTE) was not mandatory for the trial, but was performed in 64% of the cases following standard of care. In a logistic model, 3 out of 61 parameters were used in a multivariable model to predict LVT. RESULTS LVT was detected by use of CMR in 6.2% (95% confidence interval [CI] 3.1%-10.8%). LGE sequences were best to detect LVT, which may be missed in cine sequences. We identified body mass index (odds ratio 1.18; p = 0.01), baseline platelet count (odds ratio 1.01, p = 0.01) and infarct size as assessed by use of CMR (odds ratio 1.03, p = 0.02) as best predictors for LVT. The agreement between TTE and CMR for the detection of LVT is substantial (kappa = 0.70). DISCUSSION In the current analysis, the incidence of LVT shortly after AMI is relatively low, even in a patient population at high risk. An optimal modality for LVT detection is LGE-CMR but TTE has an acceptable accuracy when LGE-CMR is not available.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Since the discovery of Middle East respiratory syndrome coronavirus (MERS-CoV) in 2012, diagnostic protocols were quickly published and deployed globally. OBJECTIVES: We set out to assess the quality of MERS-CoV molecular diagnostics worldwide. STUDY DESIGN: Both sensitivity and specificity were assessed using 12 samples containing different viral loads of MERS-CoV or common coronaviruses (OC43, 229E, NL63, HKU1). RESULTS: The panel was sent to more than 106 participants, of which 99 laboratories from 6 continents returned 189 panel results.Scores ranged from 100% (84 laboratories) to 33% (1 laboratory). 15% of respondents reported quantitative results, 61% semi-quantitative (Ct-values or time to positivity) and 24% reported qualitative results. The major specific technique used was real-time RT-PCR using the WHO recommended targets upE, ORF1a and ORF1b. The evaluation confirmed that RT-PCRs targeting the ORF1b are less sensitive, and therefore not advised for primary diagnostics. CONCLUSIONS: The first external quality assessment MERS-CoV panel gives a good insight in molecular diagnostic techniques and their performances for sensitive and specific detection of MERS-CoV RNA globally. Overall, all laboratories were capable of detecting MERS-CoV with some differences in sensitivity. The observation that 8% of laboratories reported false MERS-CoV positive single assay results shows room for improvement, and the importance of using confirmatory targets.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The ATLS program by the American college of surgeons is probably the most important globally active training organization dedicated to improve trauma management. Detection of acute haemorrhagic shock belongs to the key issues in clinical practice and thus also in medical teaching. (In this issue of the journal William Schulz and Ian McConachrie critically review the ATLS shock classification Table 1), which has been criticized after several attempts of validation have failed [1]. The main problem is that distinct ranges of heart rate are related to ranges of uncompensated blood loss and that the heart rate decrease observed in severe haemorrhagic shock is ignored [2]. Table 1. Estimated blood loos based on patient's initial presentation (ATLS Students Course Manual, 9th Edition, American College of Surgeons 2012). Class I Class II Class III Class IV Blood loss ml Up to 750 750–1500 1500–2000 >2000 Blood loss (% blood volume) Up to 15% 15–30% 30–40% >40% Pulse rate (BPM) <100 100–120 120–140 >140 Systolic blood pressure Normal Normal Decreased Decreased Pulse pressure Normal or ↑ Decreased Decreased Decreased Respiratory rate 14–20 20–30 30–40 >35 Urine output (ml/h) >30 20–30 5–15 negligible CNS/mental status Slightly anxious Mildly anxious Anxious, confused Confused, lethargic Initial fluid replacement Crystalloid Crystalloid Crystalloid and blood Crystalloid and blood Table options In a retrospective evaluation of the Trauma Audit and Research Network (TARN) database blood loss was estimated according to the injuries in nearly 165,000 adult trauma patients and each patient was allocated to one of the four ATLS shock classes [3]. Although heart rate increased and systolic blood pressure decreased from class I to class IV, respiratory rate and GCS were similar. The median heart rate in class IV patients was substantially lower than the value of 140 min−1 postulated by ATLS. Moreover deterioration of the different parameters does not necessarily go parallel as suggested in the ATLS shock classification [4] and [5]. In all these studies injury severity score (ISS) and mortality increased with in increasing shock class [3] and with increasing heart rate and decreasing blood pressure [4] and [5]. This supports the general concept that the higher heart rate and the lower blood pressure, the sicker is the patient. A prospective study attempted to validate a shock classification derived from the ATLS shock classes [6]. The authors used a combination of heart rate, blood pressure, clinically estimated blood loss and response to fluid resuscitation to classify trauma patients (Table 2) [6]. In their initial assessment of 715 predominantly blunt trauma patients 78% were classified as normal (Class 0), 14% as Class I, 6% as Class II and only 1% as Class III and Class IV respectively. This corresponds to the results from the previous retrospective studies [4] and [5]. The main endpoint used in the prospective study was therefore presence or absence of significant haemorrhage, defined as chest tube drainage >500 ml, evidence of >500 ml of blood loss in peritoneum, retroperitoneum or pelvic cavity on CT scan or requirement of any blood transfusion >2000 ml of crystalloid. Because of the low prevalence of class II or higher grades statistical evaluation was limited to a comparison between Class 0 and Class I–IV combined. As in the retrospective studies, Lawton did not find a statistical difference of heart rate and blood pressure among the five groups either, although there was a tendency to a higher heart rate in Class II patients. Apparently classification during primary survey did not rely on vital signs but considered the rather soft criterion of “clinical estimation of blood loss” and requirement of fluid substitution. This suggests that allocation of an individual patient to a shock classification was probably more an intuitive decision than an objective calculation the shock classification. Nevertheless it was a significant predictor of ISS [6]. Table 2. Shock grade categories in prospective validation study (Lawton, 2014) [6]. Normal No haemorrhage Class I Mild Class II Moderate Class III Severe Class IV Moribund Vitals Normal Normal HR > 100 with SBP >90 mmHg SBP < 90 mmHg SBP < 90 mmHg or imminent arrest Response to fluid bolus (1000 ml) NA Yes, no further fluid required Yes, no further fluid required Requires repeated fluid boluses Declining SBP despite fluid boluses Estimated blood loss (ml) None Up to 750 750–1500 1500–2000 >2000 Table options What does this mean for clinical practice and medical teaching? All these studies illustrate the difficulty to validate a useful and accepted physiologic general concept of the response of the organism to fluid loss: Decrease of cardiac output, increase of heart rate, decrease of pulse pressure occurring first and hypotension and bradycardia occurring only later. Increasing heart rate, increasing diastolic blood pressure or decreasing systolic blood pressure should make any clinician consider hypovolaemia first, because it is treatable and deterioration of the patient is preventable. This is true for the patient on the ward, the sedated patient in the intensive care unit or the anesthetized patients in the OR. We will therefore continue to teach this typical pattern but will continue to mention the exceptions and pitfalls on a second stage. The shock classification of ATLS is primarily used to illustrate the typical pattern of acute haemorrhagic shock (tachycardia and hypotension) as opposed to the Cushing reflex (bradycardia and hypertension) in severe head injury and intracranial hypertension or to the neurogenic shock in acute tetraplegia or high paraplegia (relative bradycardia and hypotension). Schulz and McConachrie nicely summarize the various confounders and exceptions from the general pattern and explain why in clinical reality patients often do not present with the “typical” pictures of our textbooks [1]. ATLS refers to the pitfalls in the signs of acute haemorrhage as well: Advanced age, athletes, pregnancy, medications and pace makers and explicitly state that individual subjects may not follow the general pattern. Obviously the ATLS shock classification which is the basis for a number of questions in the written test of the ATLS students course and which has been used for decades probably needs modification and cannot be literally applied in clinical practice. The European Trauma Course, another important Trauma training program uses the same parameters to estimate blood loss together with clinical exam and laboratory findings (e.g. base deficit and lactate) but does not use a shock classification related to absolute values. In conclusion the typical physiologic response to haemorrhage as illustrated by the ATLS shock classes remains an important issue in clinical practice and in teaching. The estimation of the severity haemorrhage in the initial assessment trauma patients is (and was never) solely based on vital signs only but includes the pattern of injuries, the requirement of fluid substitution and potential confounders. Vital signs are not obsolete especially in the course of treatment but must be interpreted in view of the clinical context. Conflict of interest None declared. Member of Swiss national ATLS core faculty.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

High-energy e(-) and pi(-) were measured by the multichannel plate (MCP) detector at the PiM1 beam line of the High Intensity Proton Accelerator Facilities located at the Paul Scherrer Institute, Villigen, Switzerland. The measurements provide the absolute detection efficiencies for these particles: 5.8% +/- 0.5% for electrons in the beam momenta range 17.5-300 MeV/c and 6.0% +/- 1.3% for pions in the beam momenta range 172-345 MeV/c. The pulse height distribution determined from the measurements is close to an exponential function with negative exponent, indicating that the particles penetrated the MCP material before producing the signal somewhere inside the channel. Low charge extraction and nominal gains of the MCP detector observed in this study are consistent with the proposed mechanism of the signal formation by penetrating radiation. A very similar MCP ion detector will be used in the Neutral Ion Mass (NIM) spectrometer designed for the JUICE mission of European Space Agency (ESA) to the Jupiter system, to perform measurements of the chemical composition of the Galilean moon exospheres. The detection efficiency for penetrating radiation determined in the present studies is important for the optimisation of the radiation shielding of the NIM detector against the high-rate and high-energy electrons trapped in Jupiter's magnetic field. Furthermore, the current studies indicate that MCP detectors can be useful to measure high-energy particle beams at high temporal resolution. (C) 2015 AIP Publishing LLC.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study retrospectively evaluated the spatial and temporal disease patterns associated with influenza-like illness (ILI), positive rapid influenza antigen detection tests (RIDT), and confirmed H1N1 S-OIV cases reported to the Cameron County Department of Health and Human Services between April 26 and May 13, 2009 using the space-time permutation scan statistic software SaTScan in conjunction with geographical information system (GIS) software ArcGIS 9.3. The rate and age-adjusted relative risk of each influenza measure was calculated and a cluster analysis was conducted to determine the geographic regions with statistically higher incidence of disease. A Poisson distribution model was developed to identify the effect that socioeconomic status, population density, and certain population attributes of a census block-group had on that area's frequency of S-OIV confirmed cases over the entire outbreak. Predominant among the spatiotemporal analyses of ILI, RIDT and S-OIV cases in Cameron County is the consistent pattern of a high concentration of cases along the southern border with Mexico. These findings in conjunction with the slight northward space-time shifts of ILI and RIDT cluster centers highlight the southern border as the primary site for public health interventions. Finally, the community-based multiple regression model revealed that three factors—percentage of the population under age 15, average household size, and the number of high school graduates over age 25—were significantly associated with laboratory-confirmed S-OIV in the Lower Rio Grande Valley. Together, these findings underscore the need for community-based surveillance, improve our understanding of the distribution of the burden of influenza within the community, and have implications for vaccination and community outreach initiatives.^

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The objective of this dissertation was to design and implement strategies for assessment of exposures to organic chemicals used in the production of a styrene-butadiene polymer at the Texas Plastics Company (TPC). Linear statistical retrospective exposure models, univariate and multivariate, were developed based on the validation of historical industrial hygiene monitoring data collected by industrial hygienists at TPC, and additional current industrial hygiene monitoring data collected for the purposes of this study. The current monitoring data served several purposes. First, it provided information on current exposure data, in the form of unbiased estimates of mean exposure to organic chemicals for each job title included. Second, it provided information on homogeneity of exposure within each job title, through the use of a carefully designed sampling scheme which addressed variability of exposure both between and within job titles. Third, it permitted the investigation of how well current exposure data can serve as an evaluation tool for retrospective exposure estimation. Finally, this dissertation investigated the simultaneous evaluation of exposure to several chemicals, as well as the use of values below detection limits in a multivariate linear statistical model of exposures. ^