982 resultados para Deontic modality


Relevância:

10.00% 10.00%

Publicador:

Resumo:

X-ray mammography has been the gold standard for breast imaging for decades, despite the significant limitations posed by the two dimensional (2D) image acquisitions. Difficulty in diagnosing lesions close to the chest wall and axilla, high amount of structural overlap and patient discomfort due to compression are only some of these limitations. To overcome these drawbacks, three dimensional (3D) breast imaging modalities have been developed including dual modality single photon emission computed tomography (SPECT) and computed tomography (CT) systems. This thesis focuses on the development and integration of the next generation of such a device for dedicated breast imaging. The goals of this dissertation work are to: [1] understand and characterize any effects of fully 3-D trajectories on reconstructed image scatter correction, absorbed dose and Hounsifeld Unit accuracy, and [2] design, develop and implement the fully flexible, third generation hybrid SPECT-CT system capable of traversing complex 3D orbits about a pendant breast volume, without interference from the other. Such a system would overcome artifacts resulting from incompletely sampled divergent cone beam imaging schemes and allow imaging closer to the chest wall, which other systems currently under research and development elsewhere cannot achieve.

The dependence of x-ray scatter radiation on object shape, size, material composition and the CT acquisition trajectory, was investigated with a well-established beam stop array (BSA) scatter correction method. While the 2D scatter to primary ratio (SPR) was the main metric used to characterize total system scatter, a new metric called ‘normalized scatter contribution’ was developed to compare the results of scatter correction on 3D reconstructed volumes. Scatter estimation studies were undertaken with a sinusoidal saddle (±15° polar tilt) orbit and a traditional circular (AZOR) orbit. Clinical studies to acquire data for scatter correction were used to evaluate the 2D SPR on a small set of patients scanned with the AZOR orbit. Clinical SPR results showed clear dependence of scatter on breast composition and glandular tissue distribution, otherwise consistent with the overall phantom-based size and density measurements. Additionally, SPR dependence was also observed on the acquisition trajectory where 2D scatter increased with an increase in the polar tilt angle of the system.

The dose delivered by any imaging system is of primary importance from the patient’s point of view, and therefore trajectory related differences in the dose distribution in a target volume were evaluated. Monte Carlo simulations as well as physical measurements using radiochromic film were undertaken using saddle and AZOR orbits. Results illustrated that both orbits deliver comparable dose to the target volume, and only slightly differ in distribution within the volume. Simulations and measurements showed similar results, and all measured dose values were within the standard screening mammography-specific, 6 mGy dose limit, which is used as a benchmark for dose comparisons.

Hounsfield Units (HU) are used clinically in differentiating tissue types in a reconstructed CT image, and therefore the HU accuracy of a system is very important, especially when using non-traditional trajectories. Uniform phantoms filled with various uniform density fluids were used to investigate differences in HU accuracy between saddle and AZOR orbits. Results illustrate the considerably better performance of the saddle orbit, especially close to the chest and nipple region of what would clinically be a pedant breast volume. The AZOR orbit causes shading artifacts near the nipple, due to insufficient sampling, rendering a major portion of the scanned phantom unusable, whereas the saddle orbit performs exceptionally well and provides a tighter distribution of HU values in reconstructed volumes.

Finally, the third generation, fully-suspended SPECT-CT system was designed in and developed in our lab. A novel mechanical method using a linear motor was developed for tilting the CT system. A new x-ray source and a custom made 40 x 30 cm2 detector were integrated on to this system. The SPECT system was nested, in the center of the gantry, orthogonal to the CT source-detector pair. The SPECT system tilts on a goniometer, and the newly developed CT tilting mechanism allows ±15° maximum polar tilting of the CT system. The entire gantry is mounted on a rotation stage, allowing complex arbitrary trajectories for each system, without interference from the other, while having a common field of view. This hybrid system shows potential to be used clinically as a diagnostic tool for dedicated breast imaging.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Sound is an important medium for communication and marine organisms have evolved to capitalize on the efficiency with which sound energy travels through water. Anthropogenic and natural sound sources contribute to ocean ambient noise, which can interfere with the use of this sensory modality by marine animals. Anthropogenic noise sources have been increasing steadily over recent decades largely due to coastal population growth, increased global transportation, and offshore industrialization. Understanding the potential impacts of anthropogenic noise requires the establishment of ambient acoustic baselines from which to measure change. Establishing baselines, especially in quiet areas still largely unaffected by anthropogenic stressors, is particularly crucial in the face of the expansion of offshore industries, increasing coastal population and growing reliance on the ocean for global transportation. Global demand for liquid natural gas (LNG), catalyzed primarily by a growing Asian market, is expected to increase significantly in the next 20 years. The geographic position of British Columbia relative to these markets, a growing supply of LNG and new technology for extraction and shipping situate British Columbia as a strong competitor in the lucrative market. The LNG industry could have many adverse impacts on these territories and ecosystems. The Kitimat Fjord System is slated for the development of these LNG export facilities increasing shipping traffic for the port and thus increasing ambient noise in the fjord system. The purpose of this study is to 1) quantify the existing sound levels in the area surrounding Gil Island and 2) identify potential source mechanisms in order to provide a baseline study of the acoustic environment in the Kitimat Fjord system prior to potential increases from LNG shipping.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background. In clinical practice and in clinical trials, echocardiography and scintigraphy are used the most for the evaluation of global left ejection fraction (LVEF) and left ventricular (LV) volumes. Actually, poor quality imaging and geometrical assumptions are the main limitations of LVEF measured by echocardiography. Contrast agents and 3D echocardiography are new methods that may alleviate these potential limitations. Methods. Therefore we sought to examine the accuracy of contrast 3D echocardiography for the evaluation of LV volumes and LVEF relative to MIBI gated SPECT as an independent reference. In 43 patients addressed for chest pain, contrast 3D echocardiography (RT3DE) and MIBI gated SPECT were prospectively performed on the same day. The accuracy and the variability of LV volumes and LVEF measurements were evaluated. Results. Due to good endocardial delineation, LV volumes and LVEF measurements by contrast RT3DE were feasible in 99% of the patients. The mean LV end-diastolic volume (LVEDV) of the group by scintigraphy was 143 65 mL and was underestimated by triplane contrast RT3DE (128 60 mL; p < 0.001) and less by full-volume contrast RT3DE (132 62 mL; p < 0.001). Limits of agreement with scintigraphy were similar for triplane andfull-volume, modalities with the best results for full-volume. Results were similar for calculation of LV end-systolic volume (LVESV). The mean LVEF was 44 16% with scintigraphy and was not significantly different with both triplane contrast RT3DE (45 15%) and full-volume contrast RT3DE (45 15%). There was an excellent correlation between two different observers for LVEDV, LVESV and LVEF measurements and inter observer agreement was also good for both contrast RT3DE techniques. Conclusion. Contrast RT3DE allows an accurate assessment of LVEF compared to the LVEF measured by SPECT, and shows low variability between observers. Although RT3DE triplane provides accurate evaluation of left ventricular function, RT3DE full-volume is superior to triplane modality in patients with suspected coronary artery disease. © 2009 Cosyns et al; licensee BioMed Central Ltd.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study has investigated the effects of herpes simplex thymidine kinase gene (HSV-tk) transfer followed by ganciclovir treatment as adjuvant gene therapy to surgical resection in patients with recurrent glioblastoma multiforme (GBM). The study was open and single-arm, and aimed at assessing the feasibility and safety of the technique and indications of antitumor activity. In 48 patients a suspension of retroviral vector-producing cells (VPCs) was administered by intracerebral injection immediately after tumor resection. Intravenous ganciclovir was infused daily 14 to 27 days after surgery. Patients were monitored for adverse events and for life by regular biosafety assaying. Tumor changes were monitored by magnetic resonance imaging (MRI). Reflux during injection was a frequent occurrence but serious adverse events during the treatment period (days 1-27) were few and of a nature not unexpected in this population. One patient experienced transient neurological disorders associated with postganciclovir MRI enhancement. There was no evidence of replication-competent retrovirus in peripheral blood leukocytes or in tissue samples of reresection or autopsy. Vector DNA was shown in the leukocytes of some patients but not in autopsy gonadal samples. The median survival time was 8.6 months, and the 12-month survival rate was 13 of 48 (27%). On MRI studies, tumor recurrence was absent in seven patients for at least 6 months and for at least 12 months in two patients, one of whom remains recurrence free at more than 24 months. Treatment-characteristic images of injection tracks and intracavity hemoglobin were apparent. In conclusion, the gene therapy is feasible and appears to be satisfactorily safe as an adjuvant to the surgical resection of recurrent GBM, but any benefit appears to be marginal. Investigation of the precise effectiveness of this gene therapy requires prospective, controlled studies.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this work we present an activity for High School students in which various mathematical concepts of plane and spatial geometry are involved. The final objective of the proposed tasks is constructing a particular polyhedron, the cube, by using a modality of origami called modular origami.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Logic-based models are thriving within artificial intelligence. A great number of new logics have been defined, and their theory investigated. Epistemic logics introduce modal operators for knowledge or belief; deontic logics are about norms, and introduce operators of deontic necessity and possibility (i.e., obligation or prohibition). And then we have a much investigated class—temporal logics—to whose application to engineering this special issue is devoted. This kind of formalism deserves increased widespread recognition and application in engineering, a domain where other kinds of temporal models (e.g., Petri nets) are by now a fairly standard part of the modelling toolbox.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In advanced non-small cell lung cancer (NSCLC) platinum based chemotherapy with second generation drugs improves median survival (MS) to 8 months and 29% and 10% at 1 and 2 years. Platinum with a third generation drug can improve survival further (BMJ 1995;311: 899) (Spiro et al. Thorax 2004;59:828 Big Lung Trial; N Engl J Med 2003;346:92 ECOG study). NICE now recommends chemotherapy with platinum and a third generation drug for inoperable NSCLC as the first treatment modality. Methods: We audited survival of 176/461 consecutive patients referred for at least 3 courses of platinum and either gemcitabine or vinorelbine from July 2001 to December 2005. Minimal follow up 17 months. Chemotherapy was given on site. Radical radiotherapy for stage IIIA, palliative radiotherapy and second line drugs were given as felt appropriate. Results: 64% were male. 30 (17%) were <55 years ; 66 (37.5%) age 55–65 years; 63 (35.8%) aged 66–75 and 16 (9.1%) >75 years. 5 (2.8%) were stage II; 46 (26%) stage IIIA; 68 (38%) stage IIIB and 55 (30.8%) stage IV. 68 (38%) had 0– 2 courses; 63 (36%) 3 courses and 44 (25%) had 4 or more.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Latent inhibition (LI) is a measure of reduced learning about a stimulus to which there has been prior exposure without any consequence. It therefore requires a comparison between a pre-exposed (PE) and a non-pre-exposed (NPE) condition. Since, in animals, LI is disrupted by amphetamines and enhanced by antipsychotics, LI disruption has been proposed as a measure of the characteristic attentional deficit in schizophrenia: the inability to ignore irrelevant stimuli. The findings in humans are, however, inconsistent. In particular, a recent investigation suggested that since haloperidol disrupted LI in healthy volunteers, and LI was normal in non-medicated patients with schizophrenia, the previous findings in schizophrenic patients were entirely due to the negative effects of their medication on LI (Williams et al., 1998). We conducted two studies of antipsychotic drug effects on auditory LI using a within-subject, parallel group design in healthy volunteers. In the first of these, single doses of haloperidol (1 mg. i.v.) were compared with paroxetine (20 mg p.o.) and placebo, and in the second, chlorpromazine (100 mg p.o.) was compared with lorazepam (2 mg. p.o.) and placebo. Eye movements, neuropsychological test performance (spatial working memory (SWM), Tower of London and intra/extra dimensional shift, from the CANTAB test battery) and visual analogue rating scales, were also included as other measures of attention and frontal lobe function. Haloperidol was associated with a non-significant reduction in LI scores, and dysphoria/akathisia (Barnes Akathisia Rating Scale) in three-quarters of the subjects. The LI finding may be explained by increased distractibility which was indicated by an increase in antisaccade directional errors in this group. In contrast, LI was significantly increased by chlorpromazine but not by an equally sedative dose of lorazepam (both drugs causing marked decreases in peak saccadic velocity). Paroxetine had no effect on LI, eye movements or CANTAB neuropsychological test performance. Haloperidol was associated with impaired SWM, which correlated with the degree of dysphoria/akathisia, but no other drug effects on CANTAB measures were detected. We conclude that the effect of antipsychotics on LI is both modality and pharmacologically dependent and that further research using a wider range of antipsychotic compounds is necessary to clarify the cognitive effects of these drugs, and to determine whether there are important differences between them.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Non-invasive real time in vivo molecular imaging in small animal models has become the essential bridge between in vitro data and their translation into clinical applications. The tremendous development and technological progress, such as tumour modelling, monitoring of tumour growth and detection of metastasis, has facilitated translational drug development. This has added to our knowledge on carcinogenesis. The modalities that are commonly used include Magnetic Resonance Imaging (MRI), Computed Tomography (CT), Positron Emission Tomography (PET), bioluminescence imaging, fluorescence imaging and multi-modality imaging systems. The ability to obtain multiple images longitudinally provides reliable information whilst reducing animal numbers. As yet there is no one modality that is ideal for all experimental studies. This review outlines the instrumentation available together with corresponding applications reported in the literature with particular emphasis on cancer research. Advantages and limitations to current imaging technology are discussed and the issues concerning small animal care during imaging are highlighted.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background and purpose: Radiotherapy is widely used to palliate local symptoms in non-small-cell lung cancer. Using conventional X-ray simulation, it is often difficult to accurately localize the extent of the tumour. We report a randomized, double blind trial comparing target localization with conventional and virtual simulation.Methods: Eighty-six patients underwent both conventional and virtual simulation. The conventional simulator films were compared with digitally reconstructed radiographs (DRRs) produced from the computed tomography (CT) data. The treatment fields defined by the clinicians using each modality were compared in terms of field area, position and the implications for target coverage.Results: Comparing fields defined by each study arm, there was a major mis-match in coverage between fields in 66.2% of cases, and a complete match in only 5.2% of cases. In 82.4% of cases, conventional simulator fields were larger (mean 24.5+/-5.1% (95% confidence interval)) than CT-localized fields, potentially contributing to a mean target under-coverage of 16.4+/-3.5% and normal tissue over-coverage of 25.4+/-4.2%.Conclusions: CT localization and virtual simulation allow more accurate definition of the target volume. This could enable a reduction in geographical misses, while also reducing treatment-related toxicity.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Neural adaptation and inhibition are pervasive characteristics of the primate brain, and are probably understood better within the context of visual processing than any other sensory modality. These processes are thought to underlie illusions in which one motion affects the perceived direction of another, such as the direction aftereffect (DAE) and direction repulsion. The DAE describes how, following prolonged viewing of motion in one direction, the direction of a subsequently viewed test pattern is misperceived. In the case of direction repulsion, the direction difference between two transparently moving surfaces is over-estimated. Explanations of the DAE appeal to neural adaptation whilst direction repulsion is accounted for through lateral inhibition. Here we report on a new illusion, the Binary DAE, in which superimposed slow and fast dots moving in the same direction are perceived to move in different directions following adaptation to a mixed-speed stimulus. This new phenomenon is essentially a combination of the DAE and direction repulsion. Interestingly the magnitude of the binary DAE is greater than would be expected simply through a linear combination of the DAE and direction repulsion, suggesting that the mechanisms underlying these two phenomena interact in a non-linear fashion.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Radiation therapy is a treatment modality routinely used in cancer management so it is not unexpected that radiation-inducible promoters have emerged as an attractive tool for controlled gene therapy. The human tissue plasminogen activator gene promoter (t-PA) has been proposed as a candidate for radiogenic gene therapy, but has not been exploited to date. The purpose of this study was to evaluate the potential of this promoter to drive the expression of a reporter gene, the green fluorescent protein (GFP), in response to radiation exposure. METHODS: To investigate whether the promoter could be used for prostate cancer gene therapy, we initially transfected normal and malignant prostate cells. We then transfected HMEC-1 endothelial cells and ex vivo rat tail artery and monitored GFP levels using Western blotting following the delivery of single doses of ionizing radiation (2, 4, 6 Gy) to test whether the promoter could be used for vascular targeted gene therapy. RESULTS: The t-PA promoter induced GFP expression up to 6-fold in all cell types tested in response to radiation doses within the clinical range. CONCLUSIONS: These results suggest that the t-PA promoter may be incorporated into gene therapy strategies driving therapeutic transgenes in conjunction with radiation therapy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Rheologically structured vehicle (RSV) gels were developed as delivery systems for vaginal mucosal vaccination with an HIV-1 envelope glycoprotein (CN54gp140). RSVs comprised a mucoadhesive matrix forming and vaginal fluid absorbing polymer. The mucoadhesive and rheological properties of the RSVs were evaluated in vitro, and the distribution, antigenicity and release of CN54gp140 were analysed by ELISA. CN54gp140 was uniformly distributed within the RSVs and continuously released in vitro in an antigenically intact form over 24 h. Vaginal administration to rabbits induced specific serum IgG, and IgG and IgA in genital tract secretions. The RSVs are a viable delivery modality for vaginal immunization.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We present a multimodal detection and tracking algorithm for sensors composed of a camera mounted between two microphones. Target localization is performed on color-based change detection in the video modality and on time difference of arrival (TDOA) estimation between the two microphones in the audio modality. The TDOA is computed by multiband generalized cross correlation (GCC) analysis. The estimated directions of arrival are then postprocessed using a Riccati Kalman filter. The visual and audio estimates are finally integrated, at the likelihood level, into a particle filter (PF) that uses a zero-order motion model, and a weighted probabilistic data association (WPDA) scheme. We demonstrate that the Kalman filtering (KF) improves the accuracy of the audio source localization and that the WPDA helps to enhance the tracking performance of sensor fusion in reverberant scenarios. The combination of multiband GCC, KF, and WPDA within the particle filtering framework improves the performance of the algorithm in noisy scenarios. We also show how the proposed audiovisual tracker summarizes the observed scene by generating metadata that can be transmitted to other network nodes instead of transmitting the raw images and can be used for very low bit rate communication. Moreover, the generated metadata can also be used to detect and monitor events of interest.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The introduction of functional data into the radiotherapy treatment planning process is currently the focus of significant commercial, technical, scientific and clinical development. The potential of such data from positron emission tomography (PET) was recognized at an early stage and was integrated into the radiotherapy treatment planning process through the use of image fusion software. The combination of PET and CT in a single system (PET/CT) to form an inherently fused anatomical and functional dataset has provided an imaging modality which could be used as the prime tool in the delineation of tumour volumes and the preparation of patient treatment plans, especially when integrated with virtual simulation. PET imaging typically using F-Fluorodeoxyglucose (F-FDG) can provide data on metabolically active tumour volumes. These functional data have the potential to modify treatment volumes and to guide treatment delivery to cells with particular metabolic characteristics. This paper reviews the current status of the integration of PET and PET/CT data into the radiotherapy treatment process. Consideration is given to the requirements of PET/CT data acquisition with reference to patient positioning aids and the limitations imposed by the PET/CT system. It also reviews the approaches being taken to the definition of functional/ tumour volumes and the mechanisms available to measure and include physiological motion into the imaging process. The use of PET data must be based upon a clear understanding of the interpretation and limitations of the functional signal. Protocols for the implementation of this development remain to be defined, and outcomes data based upon clinical trials are still awaited. © 2006 The British Institute of Radiology.