408 resultados para Dentures.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
A large number of metal alloys are used in Dentistry for the manufacture of fixed and removable dentures. In the oral cavity, these structures are exposed to a chemically aggressive medium, like saliva and mechanical efforts, like mastication. In addition, acidic solutions containing fluoride ions are also frequently used in dental treatments to prevent dental plates and decays development. In this context, it was considered important to investigate the influence that a fourth element could exert when added to the ternary alloy Ni-Cr-Mo, largely used in Brazil. Therefore, electrochemical tests were done to evaluate the resistance to corrosion of quaternary alloy 65Ni-25Cr-5Mo-5Ta and 65Ni-25Cr-5Mo-5W in NaF solution 0,08mol / L, pH = 4.7. For greater understanding the microstructure and morphology of alloys were studied, through metallographic analysis, using optics microscopy and electron microscopy scanning. For the electrochemical tests were applied techniques traditionally used in corrosion researches, such as: potential measures in open circuit (OCP) and cyclic polarization (CP). It was found that both quaternary alloys showed very similar results. Comparing these quaternary alloys with the ternary 65Ni-25Cr-10Mo, it was found that the quaternary alloys exhibit greater resistance to corrosion, in other words, less passivation current density than the ternary alloy, showing that it is advantageous to add a fourth element in the alloy
Resumo:
A large number of metal alloys are used in Dentistry for the manufacture of fixed and removable dentures. In the oral cavity, these structures are exposed to a chemically aggressive medium, like saliva and mechanical efforts, like mastication. In addition, acidic solutions containing fluoride ions are also frequently used in dental treatments to prevent dental plates and decays development. In this context, it was considered important to investigate the influence that a fourth element could exert when added to the ternary alloy Ni-Cr-Mo, largely used in Brazil. Therefore, electrochemical tests were done to evaluate the resistance to corrosion of quaternary alloy 65Ni-25Cr-5Mo-5Ta and 65Ni-25Cr-5Mo-5W in NaF solution 0,08mol / L, pH = 4.7. For greater understanding the microstructure and morphology of alloys were studied, through metallographic analysis, using optics microscopy and electron microscopy scanning. For the electrochemical tests were applied techniques traditionally used in corrosion researches, such as: potential measures in open circuit (OCP) and cyclic polarization (CP). It was found that both quaternary alloys showed very similar results. Comparing these quaternary alloys with the ternary 65Ni-25Cr-10Mo, it was found that the quaternary alloys exhibit greater resistance to corrosion, in other words, less passivation current density than the ternary alloy, showing that it is advantageous to add a fourth element in the alloy
Resumo:
Objective Bacterial species have been found harboring the internal surface of dental implants as consequence of their failed connections. The aim of the present study was to compare the detection frequency of bacterial leakage from human saliva through the implantabutment interface, under non-loading conditions, using either DNA Checkerboard or culture method. Materials and methods Thirty dental implants with hexagonal platforms were connected to pre-machined abutments according to the manufacturers specifications. The assemblies were individually incubated in human saliva under anaerobic conditions for 7 similar to days at 37 degrees C. Afterward, contents from the inner parts of the implants were collected and evaluated with either DNA Checkerboard (s similar to=similar to 15) or culture (n similar to=similar to 15). Subsequently, identification and quantitation of bacterial species from saliva and implants were carried out for the group evaluated with the DNA Checkerboard method. Results Both DNA Checkerboard and culture showed positive signals of bacterial leakage in 6 of the 15 evaluated samples. Capnocytophaga gingivalis and Streptococcus mutans were the most frequently detected species harboring the internal surface of the implants followed by Veillonella parvula. Conclusion Occurrence of bacterial leakage along the implantabutment interface is comparably detected with both DNA Checkerboard hybridization and conventional culture methods.
Resumo:
Objectives: The aim of this study was to investigate the internal fit (IF) of glass-infiltrated alumina (ICA - In-Ceram Alumina), yttria-stabilized tetragonal zirconia polycrystals (Y-TZP - IPS e.max ZirCAD), and metal-ceramic (MC - Ni-Cr alloy) crowns. Material and Methods: Sixty standardized resin-tooth replicas of a maxillary first molar were produced for crown placement and divided into 3 groups (n=20 each) according to the core material used (metal, ICA or Y-TZP). The IF of the crowns was measured using the replica technique, which employs a light body polyvinyl siloxane impression material to simulate the cement layer thickness. The data were analyzed according to the surfaces obtained for the occlusal space (OS), axial space (AS) and total mean (TM) using two-way ANOVA with Tukey's multiple comparison test (p<0.05). Results: No differences among the different areas were detected in the MC group. For the Y-TZP and ICA groups, AS was statistically lower than both OS and TM. No differences in AS were observed among the groups. However, OS and TM showed significantly higher values for ICA and Y-TZP groups than MC group. Comparisons of ICA and Y-TZP revealed that OS was significantly lower for Y-TZP group, whereas no differences were observed for TM. Conclusions: The total mean achieved by all groups was within the range of clinical acceptability. However, the metal-ceramic group demonstrated significantly lower values than the all-ceramic groups, especially in OS.
Resumo:
Aim. This work tested the effect of the addition of Al2O3/GdAlO3 longitudinal fibers in different contents to veneering porcelain of two dental all ceramic systems. Methods: Fibers (0.5 mm diameter) obtained by the Laser Heated Pedestal Growth (LHPG) method were added to bar-shaped specimens made by veneer porcelain (monolayers) or both the veneer and the core ceramic (bilayers) of two all-ceramic systems: In-Ceram Alumina - glass infiltrated alumina composite (GIA) and In-Ceram 2000 AL Cubes - alumina polycrystal (AP) (VITA Zahnfabrik). The longitudinal fibers were added to veneering porcelain (VM7) in two different proportions: 10 or 17 vol%. The bars were divided into nine experimental conditions (n = 10) according to material used: VM7 porcelain monolayers, VM7/GIA, VM7/AP; and according to the amount of fibers within the porcelain layer: no fibers, 10 vol% or 17 vol%. After grinding and polishing the specimens were submitted to a three point bending test (crosshead speed = 0.5 mm/min) with porcelain positioned at tensile side. Data were analyzed by means of one-way ANOVA and a Tukey's test (alpha = 5%). Scanning electronic microscopy (SEM) was conducted for fractographic analysis. Results. Regarding the groups without fiber addition, VM7/AP showed the highest flexural strength (MPa), followed by VM7/GIA and VM7 monolayers. The addition of fibers led to a numerical increase in flexural strength for all groups. For VM7/GIA bilayers the addition of 17 vol% of fibers resulted in a significant 48% increase in the flexural strength compared to the control group. Fractographic analysis revealed that the crack initiation site was in porcelain at the tensile surface. Cracks also propagated between fibers before heading for the alumina core. Conclusions. The addition of 17 vol% of Al2O3/GdAlO3 longitudinal fibers to porcelain/glass infiltrated alumina bilayers significantly improved its flexural strength. 10 vol% or 17 vol% of fibers inclusion increased the flexural strength for all groups. (C) 2011 Elsevier Ltd. All rights reserved.
Resumo:
Purpose: This study compared the maintenance of tightening torque in different retention screw types of implant-supported crowns. Materials and Methods: Twelve metallic crowns in UCLA abutments cast with cobalt-chromium alloy were attached to external hexagon osseointegrated implants with different retention screws: group A: titanium alloy retention screw; group B: gold alloy retention screw with gold coating; group C: titanium alloy retention screw with diamond-like carbon film coating; and group D: titanium alloy retention screw with aluminum titanium nitride coating. Three detorque measurements were obtained after torque insertion in each replica. Data were evaluated by analysis of variance (ANOVA), Tukey's test (P < 0.05), and t test (P < 0.05). Results: Detorque value reduced in all groups (P < 0.05). Group A retained the highest percentage of torque in comparison with the other groups (P < 0.05). Groups B and D retained the lowest percentage of torque without statistically significant difference between them (P < 0.05). Conclusions: All screw types exhibited reduction in the detorque value. The titanium screw maintained the highest percentage of torque whereas the gold-coated screw and the titanium screw with aluminum titanium nitride coating retained the lowest percentage. (Implant Dent 2012;21:46-50)
Resumo:
Objectives: The aim of this study was to evaluate the variation in removal torque of implant prosthetic abutment screws after successive tightening and loosening cycles, in addition to evaluating the influence of the hexagon at the abutment base on screw removal torque. Material and methods: Twenty hexagonal abutments were tightened to 20 regular external hex implants with a titanium alloy screw, with an insertion torque of 32 N cm, measured with a digital torque gauge. The implant/abutment/screw assemblies were divided into two groups: ( 1) abutments without hexagon at the base and ( 2) abutments with a hexagon at the base. Each assembly received a provisional restoration and was submitted to mechanical loading cycles. After this, the screws were removed and the removal torque was measured. This sequence was repeated 10 times, then the screw was replaced by a new one, and another cycle was performed. Linear regression analysis was performed. Results: Removal torque values tended to decrease as the number of insertion/removal cycles increased, for both groups. Comparisons of the slopes and the intercepts between groups showed no statistical difference. There was no significant difference between the mean values of last five cycles and the 11th cycle. Within the limitations of this in vitro study, it was concluded that ( 1) repeated insertion/removal cycles promoted gradual reduction in removal torque of screws, ( 2) replacing the screw with a new one after 10 cycles did not increase resistance to loosening, and ( 3) removal of the hexagon from the abutment base had no effect on the removal torque of the screws.
Resumo:
Bars and steel wires are the most commonly used methods to achieve maxillomandibular fixation, although there are numerous alternatives described for this same purpose. In cases of edentulous candidates for the conservative treatment of facial fractures, none of the conventional methods can be instituted for maxillomandibular fixation. Fixation in such cases is achieved with the aid of the total dentures of the patient or the confection of splints, but these methods lead to eating and oral hygiene problems. This article reports the case of an edentulous patient with a comminuted mandible fracture treated with a rarely described technique in which intermaxillary fixation was achieved with titanium miniplates.
Resumo:
Objective: To evaluate 16 patients of both sexes with lower overdenture and upper complete dentures, by analysing the resonance frequency of the initial and late stability of implants used to retain the overdenture under immediate loading. Background: Oral rehabilitation treatment with complete dentures using implants has been increasingly more common among the specialists in the oral rehabilitation area. This is an alternative for obtaining retention and stability in treatments involving conventional complete dentures, where two implants are enough to retain the overdenture satisfactorily. Materials and methods: The Osstell (TM) Mentor device was used for the analysis in the initial period (primary stability), 3 and 15 months after the installation of the lower overdenture (secondary stability). The statistical analysis was performed with the repeated measures model (p < 0.01). Results: The implant stability quotients were observed to increase after 15 months of the rehabilitating treatment. Conclusion: The use of overdentures over two lower implants should become the treatment of choice for individuals who have a fully edentulous mandible.
Resumo:
'Objectives: To analyse the validity of the Brazilian versions of OHIP-EDENT and GOHAI as assessment tools of edentulous subjects' OHRQoL. Background: Inventories for measuring oral health-related quality of life (OHRQoL) are important in clinical studies regarding oral rehabilitation. However, there is a need for comprehensive validation after translation into different cultural settings. Materials and methods: The sample comprised of 100 complete denture wearers (29 men, 71 women, mean age of 65.2 +/- 9.9 years). The associations between each OHRQoL inventory and other variables served as measurements of construct validity. Data analysis comprised the Spearman correlation test as well as multiple regression using the OHRQoL inventories as dependent variables and the other scales as determinants. Results: Both OHRQoL inventories showed good correlation with denture satisfaction, whereas lower correlation coefficients were found among the inventories and the HAD subscales. Denture satisfaction alone explained 48% and 39% of the variance found for the OHIP-EDENT and GOHAI, respectively, as assessed by multiple regression. A smaller effect was found for OHIP-EDENT. Conclusion: Both OHIP-EDENT and GOHAI showed good construct validity for measurement of OHRQoL of edentulous subjects.
Resumo:
Purpose: This study aimed to investigate (1) the influence of complete denture quality and years of denture use on masticatory efficiency and (2) the relationship between complete denture quality and years of use. Materials and Methods: A cross-sectional study was conducted with 93 edentulous patients (mean age: 65.6 years) wearing both mandibular and maxillary dentures. Patients were classified into two categories according to years of denture use: <= 2 years and >= 5 years. Masticatory efficiency was evaluated via the colorimetric method with beads as the artificial test food. A reproducible method for objective evaluation of the technical quality of complete dentures was employed. The association between denture quality and years of denture use was analyzed using chi-square and Fisher exact tests. The results of masticatory efficiency testing were analyzed using two-way analysis of variance (with the Tukey post hoc test) in terms of years of denture use <= 2 years, >= 5 years) and denture quality (poor, average, good). Results: A significant relationship was found between denture quality and years of denture use (P < .05). Masticatory efficiency differed significantly (P < .05) between patients with <= 2 years of denture use (0.101 +/- 0.076 absorbance) and >= 5 years of use (0.068 +/- 0.076 absorbance). Masticatory efficiency was not influenced by denture quality. Conclusions: Complete denture quality and masticatory efficiency significantly decreased over time. However, complete denture quality did not influence masticatory efficiency. Int J Prosthodont 2012;25:625-630.
Resumo:
There is no consensus in the literature about the impact of complete denture wear on obstructive sleep apnea (OSA). The goal of this randomized clinical study was to assess if complete denture wear during sleep interferes with the quality of sleep. Elderly edentulous OSA patients from a complete denture clinic were enrolled and received new complete dentures. An objective sleep analysis was determined with polysomnography performed at the sleep laboratory for all patients who slept either with or without their dentures. Twenty-three patients (74% females) completed the study with a mean age of 69.6 years and a mean body mass index of 26.7 kg/m(2). The apnea and hypopnea index (AHI) was significantly higher when patients slept with dentures compared to without (25.9 +/- 14.8/h vs. 19.9 +/- 10.2/h; p > 0.005). In the mild OSA group, the AHI was significantly higher when patients slept with the dentures (16.6 +/- 6.9 vs. 8.9 +/- 2.4; p < 0.05), while in moderate to severe OSA patients, the AHI was not significantly different when sleeping with dentures (.30.8 +/- 15.6 vs. 25.7 +/- 7.5; p = 0.2). The supine AHI in mild patients was related to a higher increase in AHI while wearing dentures (12.7 +/- 8.4/h vs. 51.9 +/- 28.6/h; p < 0.001). A limitation of the study is that the mild OSA patients had a higher BMI when compared to the moderate to severe OSA patients. Ten out of 14 patients who preferred to sleep with their upper and lower dentures showed an increase in their AHI while wearing dentures to sleep. Contrary to previous studies, we found that OSA patients may experience more apneic events if they sleep with their dentures in place. Specifically, in mild OSAS patients, the use of dentures substantially increases the AHI especially when in the supine position.
Resumo:
Background: Knowledge of benefits caused by a treatment on quality of life is very relevant. Despite the wide use and acceptance of soft denture liners, it is necessary to evaluate the patient's response about the use of these materials with regard to improvement in oral health related quality of life (OHRQoL). Objectives: The aim of this study was to evaluate the influence of denture relining in the OHRQoL of edentulous patients. Materials and methods: Thirty-two complete denture wearers had their lower dentures relined with a silicone-based material (Mucopren soft, Kettenbach, Germany) according to chairside procedures. OHRQoL was assessed before and after 3 months of relining by means of OHIP-EDENT, and the median scores were compared by Wilcoxon test (p <= 0.05). Results: After 3 months of relining, participants reported significant improvement of their OHRQoL (p <= 0.01). Conclusion: Denture relining with a soft liner may have a positive impact on the perceived oral health of edentulous patients.