992 resultados para Compound enhancement techniques
Resumo:
The objective of the present study was to determine the prevalence of certain mycoplasma species, i.e., Mycoplasma hominis, Ureaplasma urealyticum and Mycoplasma penetrans, in urethral swabs from HIV-1 infected patients compared to swabs from a control group. Mycoplasmas were detected by routine culture techniques and by the Polymerase Chain Reaction (PCR) technique, using 16SrRNA generic primers of conserved region and Mycoplasma penetrans specific primers. The positivity rates obtained with the two methods were comparable. Nevertheless, PCR was more sensitive, while the culture techniques allowed the quantification of the isolates. The results showed no significant difference (p < 0.05) in positivity rates between the methods used for mycoplasma detection.
Resumo:
Paleoparasitology is the study of parasites found in archaeological material. The development of this field of research began with histological identification of helminth eggs in mummy tissues, analysis of coprolites, and recently through molecular biology. An approach to the history of paleoparasitology is reviewed in this paper, with special reference to the studies of ancient DNA identified in archaeological material.
Resumo:
A presente dissertação tem como principal propósito avaliar o desempenho energético e a qualidade do ar interior do edifício principal do Parque Biológico de Vila Nova de Gaia (PBG). Para esse efeito, este estudo relaciona os termos definidos na legislação nacional em vigor até à presente data, e referentes a esta área de atuação, em particular, os presentes no SCE, RSECE, RCCTE e RSECE-QAI. Para avaliar o desempenho energético, procedeu-se numa primeira fase ao processo de auditoria no local e posteriormente à realização de uma simulação dinâmica detalhada, cuja modelação do edifício foi feita com recurso ao software DesignBuilder. Após a validação do modelo simulado, por verificação do desvio entre os consumos energéticos registados nas faturas e os calculados na simulação, igual a 5,97%, foi possível efetuar a desagregação dos consumos em percentagem pelos diferentes tipos de utilizações. Foi também possível determinar os IEE real e nominal, correspondendo a 29,9 e 41.3 kgep/m2.ano, respetivamente, constatando-se através dos mesmos que o edifício ficaria dispensado de implementar um plano de racionalização energética (PRE) e que a classe energética a atribuir é a C. Contudo, foram apresentadas algumas medidas de poupança de energia, de modo a melhorar a eficiência energética do edifício e reduzir a fatura associada. Destas destacam-se duas propostas, a primeira propõe a alteração do sistema de iluminação interior e exterior do edifício, conduzindo a uma redução no consumo de eletricidade de 47,5 MWh/ano, com um período de retorno de investimento de 3,5 anos. A segunda está relacionada com a alteração do sistema de produção de água quente para o aquecimento central, através do incremento de uma caldeira a lenha ao sistema atual, que prevê uma redução de 50 MWh no consumo de gás natural e um período de retorno de investimento de cerca de 4 anos. Na análise realizada à qualidade do ar interior (QAI), os parâmetros quantificados foram os exigidos legalmente, excetuando os microbiológicos. Deste modo, para os parâmetros físicos, temperatura e humidade relativa, obtiveram-se os resultados médios de 19,7ºC e 66,9%, respetivamente, ligeiramente abaixo do previsto na legislação (20,0ºC no período em que foi feita a medição, inverno). No que diz respeito aos parâmetros químicos, os valores médios registados para as concentrações de dióxido de carbono (CO2), monóxido de carbono (CO), ozono (O3), formaldeído (HCHO), partículas em suspensão (PM10) e radão, foram iguais a 580 ppm, 0,2 ppm, 0,06 ppm, 0,01 ppm, 0,07 mg/m3 e 196 Bq/m3, respetivamente, verificando-se que estão abaixo dos valores máximos de referência presentes no regulamento (984 ppm, 10,7 ppm, 0,10 ppm, 0,08 ppm, 0,15 mg/m3 e 400 Bq/m3). No entanto, o parâmetro relativo aos compostos orgânicos voláteis (COV) teve um valor médio igual a 0,84 ppm, bastante acima do valor máximo de referência (0,26 ppm). Neste caso, terá que ser realizada uma nova série de medições utilizando meios cromatográficos, para avaliar qual(ais) são o(s) agente(s) poluidor(es), de modo a eliminar ou atenuar as fontes de emissão.
Resumo:
Dissertation presented in fulfilment of the requirements for the Master’s degree in Conservation and Restoration
Resumo:
Dissertation for the degree of Doctor of Philosophy in Physics
Resumo:
Chromoblastomycosis (CBM) is a chronic subcutaneous infection caused by several dematiaceous fungi. The most commonly etiological agent found in Brazil is Fonsecaea pedrosoi, which appears as thick walled, brownish colored cells with transverse and longitudinal division in the lesions, called "muriform cells". This disease is found worldwide but countries like Madagascar and Brazil have highest incidence. Diagnosis is made by clinical, direct and histopathologic examination and culture of specimens. Serological tests have been used to identify specific antibodies against Fonsecaea pedrosoi antigens, as well as immunotechniques have been used for CBM serological identification and diagnosis. In the present study double immunodiffusion (DID), counterimmunoelectrophoresis (CIE) and immunoenzymatic test (ELISA) have been used to evaluate humoral immune response in patients with CBM caused by F. pedrosoi. Metabolic antigen was used for immunoprecipitation tests (DID and CIE) while somatic antigen for ELISA. Our results demonstrated 53% sensitivity and 96% specificity for DID, while CIE presented 68% sensitivity and 90.5% specificity. ELISA demonstrated 78% sensibility and 83% specificity. Serological tests can be a useful tool to study different aspects of CBM, such as helping differential diagnosis, when culture of the pathogenic agent is impossible.
Resumo:
In the present study, the performance of Immunomagnetic Separation technique, coupled with Immunofluorescence (IMS-IFA), was compared with the FAUST et al. and Lutz parasitological techniques for the detection of Giardia lamblia cysts in human feces. One hundred and twenty-seven samples were evaluated by the three techniques at the same time showing a rate of cyst detection of 27.5% by IMS-IFA and 15.7% by both Faust et al. and Lutz techniques. Data analysis showed a higher sensitivity of IMS-IFA for the detection of G. lamblia cysts in comparison with the techniques of FAUST et al. and Lutz. The use of this methodology as a routine procedure enables the processing of many samples simultaneously, in order to increase recovery rate of G. lamblia cysts and reduce the time of sample storage.
Resumo:
Monitoring organic environmental contaminants is of crucial importance to ensure public health. This requires simple, portable and robust devices to carry out on-site analysis. For this purpose, a low-temperature co-fired ceramics (LTCC) microfluidic potentiometric device (LTCC/μPOT) was developed for the first time for an organic compound: sulfamethoxazole (SMX). Sensory materials relied on newly designed plastic antibodies. Sol–gel, self-assembling monolayer and molecular-imprinting techniques were merged for this purpose. Silica beads were amine-modified and linked to SMX via glutaraldehyde modification. Condensation polymerization was conducted around SMX to fill the vacant spaces. SMX was removed after, leaving behind imprinted sites of complementary shape. The obtained particles were used as ionophores in plasticized PVC membranes. The most suitable membrane composition was selected in steady-state assays. Its suitability to flow analysis was verified in flow-injection studies with regular tubular electrodes. The LTCC/μPOT device integrated a bidimensional mixer, an embedded reference electrode based on Ag/AgCl and an Ag-based contact screen-printed under a micromachined cavity of 600 μm depth. The sensing membranes were deposited over this contact and acted as indicating electrodes. Under optimum conditions, the SMX sensor displayed slopes of about −58.7 mV/decade in a range from 12.7 to 250 μg/mL, providing a detection limit of 3.85 μg/mL and a sampling throughput of 36 samples/h with a reagent consumption of 3.3 mL per sample. The system was adjusted later to multiple analyte detection by including a second potentiometric cell on the LTCC/μPOT device. No additional reference electrode was required. This concept was applied to Trimethoprim (TMP), always administered concomitantly with sulphonamide drugs, and tested in fish-farming waters. The biparametric microanalyzer displayed Nernstian behaviour, with average slopes −54.7 (SMX) and +57.8 (TMP) mV/decade. To demonstrate the microanalyzer capabilities for real applications, it was successfully applied to single and simultaneous determination of SMX and TMP in aquaculture waters.
Resumo:
1st ASPIC International Congress
Resumo:
Pentamidine (PEN) is an alternative compound to treat antimony-resistant leishmaniasis patients, which cellular target remains unclear. One approach to the identification of prospective targets is to identify genes able to mediate PEN resistance following overexpression. Starting from a genomic library of transfected parasites bearing a multicopy episomal cosmid vector containing wild-type Leishmania major DNA, we isolated one locus capable to render PEN resistance to wild type cells after DNA transfection. In order to map this Leishmania locus, cosmid insert was deleted by two successive sets of partial digestion with restriction enzymes, followed by transfection into wild type cells, overexpression, induction and functional tests in the presence of PEN. To determine the Leishmania gene related to PEN resistance, nucleotide sequencing experiments were done through insertion of the transposon Mariner element of Drosophila melanogaster (mosK) into the deleted insert to work as primer island. Using general molecular techniques, we described here this method that permits a quickly identification of a functional gene facilitating nucleotide sequence experiments from large DNA fragments. Followed experiments revealed the presence of a P-Glycoprotein gene in this locus which role in Leishmania metabolism has now been analyzed.
Resumo:
Recently, operational matrices were adapted for solving several kinds of fractional differential equations (FDEs). The use of numerical techniques in conjunction with operational matrices of some orthogonal polynomials, for the solution of FDEs on finite and infinite intervals, produced highly accurate solutions for such equations. This article discusses spectral techniques based on operational matrices of fractional derivatives and integrals for solving several kinds of linear and nonlinear FDEs. More precisely, we present the operational matrices of fractional derivatives and integrals, for several polynomials on bounded domains, such as the Legendre, Chebyshev, Jacobi and Bernstein polynomials, and we use them with different spectral techniques for solving the aforementioned equations on bounded domains. The operational matrices of fractional derivatives and integrals are also presented for orthogonal Laguerre and modified generalized Laguerre polynomials, and their use with numerical techniques for solving FDEs on a semi-infinite interval is discussed. Several examples are presented to illustrate the numerical and theoretical properties of various spectral techniques for solving FDEs on finite and semi-infinite intervals.
Resumo:
RESUMO: Relevância e Objectivos: O objectivo deste estudo consistiu em verificar a eficácia e segurança de uma técnica de higiene brônquica – Active Cycle breathing technique (ACBT), na remoção de secreções e desinsuflação em crianças asmáticas. É uma técnica recente, que ainda não foi estudada nesta população. Metodologia: A amostra foi constituída por um total de 14 crianças, com idades compreendidas entre os 6 e 18 anos, com o diagnóstico de asma. Foi dividida em dois grupos: grupo de controlo, constituído por asmáticos estáveis e grupo experimental constituído por asmáticos pós-crise. Ambos receberam o mesmo tratamento, que consistiu numa única sessão de ACBT. Realizaram um exame da função respiratória (variáveis FEV1, PEF, MEF75%, RV e FRC) antes e após a aplicação da técnica. Mediu-se a Saturação de O2 antes, a meio e no fim da aplicação da técnica. Por último, pesaram-se as secreções recolhidas durante a sessão de tratamento. Resultados: Como resultados, quando omparamos o antes e após aplicação do ACBT, obtivemos diferenças significativas no RV (p <0,05) e FRC (p <0,05); muito significativa na Sa02 (p <0,01) e peso de secreções, nos asmáticos pós crise. Ocorreu uma melhoria significativa da saturação (p <0,05) em asmáticos estáveis, não havendo secreções. Não houve efeitos adversos nem broncoespasmo em ambos os grupos.Conclusão: O ACBT é uma técnica que promove a remoção de secreções e diminuição da insuflação na população de asmáticos.--------------------ABSTRACT:Relevance and Goals: the goal of this study was to verify the efficiency and security of a bronchial hygienic technique - Active Cycle Breathing Technique (ACBT) – in the obstruction and insufflation of asthmatic children. This is a new technique that has not yet been studied in this population. Procedures: The subjects were 14 children aged between 6 and 18 years old with asthma diagnosis. They were divided in two groups: the control group with stable asthmatics and the experimental group with post-crisis asthmatics. Both received the same treatment that was a single session of ACBT. They made a lung function test before and after the application of the technique (variables FEV1, PEF, MEF75%, RV and FRC). The level of O2 saturation was measured before, during and after the procedure. In the end, the secretions collected during the treatment were weighted. Results: We observed a significant difference on RV (p ˂0,05), FRC (p ˂0,05), Sa02 (p ˂0,01) and in the weight of the secretions in the post-crisis asthmatics after ACBT. There was a significant improvement of saturation (p ˂0,05) only in the stable asthmatics. There were no adverse effects or bronchospasm in both groups.