752 resultados para Body-image questionnaire
Resumo:
To assess the temperature dependency of tissue contrast on post mortem magnetic resonance (PMMR) images both objectively and subjectively; and to visually demonstrate the changes of image contrast at various temperatures.
Resumo:
The objective of this retrospective study was to assess image quality with pulmonary CT angiography (CTA) using 80 kVp and to find anthropomorphic parameters other than body weight (BW) to serve as selection criteria for low-dose CTA. Attenuation in the pulmonary arteries, anteroposterior and lateral diameters, cross-sectional area and soft-tissue thickness of the chest were measured in 100 consecutive patients weighing less than 100 kg with 80 kVp pulmonary CTA. Body surface area (BSA) and contrast-to-noise ratios (CNR) were calculated. Three radiologists analyzed arterial enhancement, noise, and image quality. Image parameters between patients grouped by BW (group 1: 0-50 kg; groups 2-6: 51-100 kg, decadally increasing) were compared. CNR was higher in patients weighing less than 60 kg than in the BW groups 71-99 kg (P between 0.025 and <0.001). Subjective ranking of enhancement (P = 0.165-0.605), noise (P = 0.063), and image quality (P = 0.079) did not differ significantly across all patient groups. CNR correlated moderately strongly with weight (R = -0.585), BSA (R = -0.582), cross-sectional area (R = -0.544), and anteroposterior diameter of the chest (R = -0.457; P < 0.001 all parameters). We conclude that 80 kVp pulmonary CTA permits diagnostic image quality in patients weighing up to 100 kg. Body weight is a suitable criterion to select patients for low-dose pulmonary CTA.
Resumo:
The motion of lung tumors during respiration makes the accurate delivery of radiation therapy to the thorax difficult because it increases the uncertainty of target position. The adoption of four-dimensional computed tomography (4D-CT) has allowed us to determine how a tumor moves with respiration for each individual patient. Using information acquired during a 4D-CT scan, we can define the target, visualize motion, and calculate dose during the planning phase of the radiotherapy process. One image data set that can be created from the 4D-CT acquisition is the maximum-intensity projection (MIP). The MIP can be used as a starting point to define the volume that encompasses the motion envelope of the moving gross target volume (GTV). Because of the close relationship that exists between the MIP and the final target volume, we investigated four MIP data sets created with different methodologies (3 using various 4D-CT sorting implementations, and one using all available cine CT images) to compare target delineation. It has been observed that changing the 4D-CT sorting method will lead to the selection of a different collection of images; however, the clinical implications of changing the constituent images on the resultant MIP data set are not clear. There has not been a comprehensive study that compares target delineation based on different 4D-CT sorting methodologies in a patient population. We selected a collection of patients who had previously undergone thoracic 4D-CT scans at our institution, and who had lung tumors that moved at least 1 cm. We then generated the four MIP data sets and automatically contoured the target volumes. In doing so, we identified cases in which the MIP generated from a 4D-CT sorting process under-represented the motion envelope of the target volume by more than 10% than when measured on the MIP generated from all of the cine CT images. The 4D-CT methods suffered from duplicate image selection and might not choose maximum extent images. Based on our results, we suggest utilization of a MIP generated from the full cine CT data set to ensure a representative inclusive tumor extent, and to avoid geometric miss.
Resumo:
Life expectancy continuously increases but our society faces age-related conditions. Among musculoskeletal diseases, osteoporosis associated with risk of vertebral fracture and degenerative intervertebral disc (IVD) are painful pathologies responsible for tremendous healthcare costs. Hence, reliable diagnostic tools are necessary to plan a treatment or follow up its efficacy. Yet, radiographic and MRI techniques, respectively clinical standards for evaluation of bone strength and IVD degeneration, are unspecific and not objective. Increasingly used in biomedical engineering, CT-based finite element (FE) models constitute the state-of-art for vertebral strength prediction. However, as non-invasive biomechanical evaluation and personalised FE models of the IVD are not available, rigid boundary conditions (BCs) are applied on the FE models to avoid uncertainties of disc degeneration that might bias the predictions. Moreover, considering the impact of low back pain, the biomechanical status of the IVD is needed as a criterion for early disc degeneration. Thus, the first FE study focuses on two rigid BCs applied on the vertebral bodies during compression test of cadaver vertebral bodies, vertebral sections and PMMA embedding. The second FE study highlights the large influence of the intervertebral disc’s compliance on the vertebral strength, damage distribution and its initiation. The third study introduces a new protocol for normalisation of the IVD stiffness in compression, torsion and bending using MRI-based data to account for its morphology. In the last study, a new criterion (Otsu threshold) for disc degeneration based on quantitative MRI data (axial T2 map) is proposed. The results show that vertebral strength and damage distribution computed with rigid BCs are identical. Yet, large discrepancies in strength and damage localisation were observed when the vertebral bodies were loaded via IVDs. The normalisation protocol attenuated the effect of geometry on the IVD stiffnesses without complete suppression. Finally, the Otsu threshold computed in the posterior part of annulus fibrosus was related to the disc biomechanics and meet objectivity and simplicity required for a clinical application. In conclusion, the stiffness normalisation protocol necessary for consistent IVD comparisons and the relation found between degeneration, mechanical response of the IVD and Otsu threshold lead the way for non-invasive evaluation biomechanical status of the IVD. As the FE prediction of vertebral strength is largely influenced by the IVD conditions, this data could also improve the future FE models of osteoporotic vertebra.
Resumo:
OBJECTIVES To find a threshold body weight (BW) below 100 kg above which computed tomography pulmonary angiography (CTPA) using reduced radiation and a reduced contrast material (CM) dose provides significantly impaired quality and diagnostic confidence compared with standard-dose CTPA. METHODS In this prospectively randomised study of 501 patients with suspected pulmonary embolism and BW <100 kg, 246 were allocated into the low-dose group (80 kVp, 75 ml CM) and 255 into the normal-dose group (100 kVp, 100 ml CM). Contrast-to-noise ratio (CNR) in the pulmonary trunk was calculated. Two blinded chest radiologists independently evaluated subjective image quality and diagnostic confidence. Data were compared between the normal-dose and low-dose groups in five BW subgroups. RESULTS Vessel attenuation did not differ between the normal-dose and low-dose groups within each BW subgroup (P = 1.0). The CNR was higher with the normal-dose compared with the low-dose protocol (P < 0.006) in all BW subgroups except for the 90-99 kg subgroup (P = 0.812). Subjective image quality and diagnostic confidence did not differ between CT protocols in all subgroups (P between 0.960 and 1.0). CONCLUSIONS Subjective image quality and diagnostic confidence with 80 kVp CTPA is not different from normal-dose protocol in any BW group up to 100 kg. KEY POINTS • 80 kVp CTPA is safe in patients weighing <100 kg • Reduced radiation and iodine dose still provide high vessel attenuation • Image quality and diagnostic confidence with low-dose CTPA is good • Diagnostic confidence does not deteriorate in obese patients weighing <100 kg.
Resumo:
Universidade Estadual de Campinas . Faculdade de Educação Física
Resumo:
Universidade Estadual de Campinas. Faculdade de Educação Física
Resumo:
GUALANO, B., M. NEVES JR, F. R. LIMA, A. L. PINTO, G. LAURENTINO, C. BORGES, L. BAPTISTA, G. G. ARTIOLI, M. S. AOKI, A. MORISCOT, A. H. LANCHA JR, E. BONFA, and C. UGRINOWITSCH. Resistance Training with Vascular Occlusion in Inclusion Body Myositis: A Case Study. Med Sci. Spot-is Exerc., Vol. 42, No. 2, pp. 250-254, 2010. Inclusion body myositis (IBM) is a rare idiopathic inflammatory myopathy that produces remarkable muscle weakness. Resistance training with vascular occlusion has been shown to improve muscle strength and cross-sectional area in other muscle wasting conditions. Purpose: We evaluated the efficacy of a moderate-intensity resistance training program combined with vascular occlusion by examining functional capacity, muscle morphology, and changes in the expression of genes related to muscle protein synthesis and proteolysis in a patient with IBM. Methods: A 65-yr-old man with IBM resistant to all proposed treatments underwent resistance training with vascular occlusion for 12 wk. Leg press one-repetition maximum; thigh cross-sectional area; balance, mobility, and muscle function; quality of life; and blood markers of inflammation and muscle damage were assessed at baseline and after the 12-wk program. The messenger RNA (mRNA) expression levels of mechanogrowth factor, mammalian target of rapamycin, atrogin-1, and muscle RING finger-1 were also quantified. Results: After the 12-wk training program, the patient`s leg press one-repetition maximum, balance and mobility function, and thigh cross-sectional area increased 15.9%, 60%, and 4.7%, respectively. All Short Form-36 Health Survey Questionnaire subscales demonstrated improvements as well, varying from 18% to 600%. mRNA expression of mechanogrowth factor increased 3.97-fold, whereas that of atrogin-1 decreased 0.62-fold. Muscle RING finger-1 and mammalian target of rapamycin mRNA levels were only slightly altered, 1.18- and 1.28-fold, respectively. Importantly, the exercise did not induce disease flare. Conclusions: We describe a novel, and likely the first, nonpharmacological therapeutic tool that might be able to counteract the muscle atrophy and the declining strength that usually occur in IBM.
Resumo:
Objectives: The aim of this study was to evaluate the fluoride intake of 2-6-year-old Brazilian children using a semiquantitative food frequency questionnaire (FFQ) which also estimated fluoride intake from dentifrice. Methods: The FFQ was previously validated through application to 78 2-6-year-old Brazilian children and then administered to 379 children residing in an optimally fluoridated community in Brazil (Bauru, State of Sao Paulo). The FFQ was applied to the parents and used to estimate the food intake of the children. The constituents of the diet were divided into solids, water and other beverages. The fluoride content of the diet items was analyzed with the fluoride electrode. The questionnaire also estimated fluoride intake from dentifrice. Results: The average (+/- SD) fluoride intake from solids, water, other beverages and dentifrice was 0.008 +/- 0.005; 0.011 +/- 0.004; 0.009 +/- 0.014 and 0.036 +/- 0.028 mg F/kg body weight/day, respectively, totalizing 0.064 +/- 0.035 mg F/kg body weight/day. The dentifrice and the diet contributed with 56.3% and 43.7% of the daily fluoride intake, respectively. Among the children evaluated, 31.2% are estimated to have risk to develop dental fluorosis (intake > 0.07 mg F/kg body weight/day). Conclusions: The dentifrice was the main source of fluoride intake by the children evaluated. However, the fluoride concentration in food items also significantly contributed to the daily ingestion by 2-6-year-old children. The questionnaire used seems to be a promising alternative to duplicate diet to estimate the fluoride intake at this age range and may have potential to be used in broad epidemiological surveys.
Resumo:
Background: Concerns exist regarding the effect of radiation dose from paediatric pelvic CT scans and the potential later risk of radiation-induced neoplasm and teratogenic outcomes in these patients. Objective: To assess the diagnostic quality of CT images of the paediatric pelvis using either reduced mAs or increased pitch compared with standard settings. Materials and methods: A prospective study of pelvic CT scans of 105 paediatric patients was performed using one of three protocols: (1) 31 at a standard protocol of 200 mA with rotation time of 0.75 s at 120 kVp and a pitch factor approximating 1.4; (2) 31 at increased pitch factor approaching 2 and 200 mA; and (3) 43 at a reduced setting of 100 mA and a pitch factor of 1.4. All other settings remained the same in all three groups. Image quality was assessed by radiologists blinded to the protocol used in each scan. Results: No significant difference was found between the quality of images acquired at standard settings and those acquired at half the standard mAs. The use of increased pitch factor resulted in a higher proportion of poor images. Conclusions: Images acquired at 120 kVp using 75 mAs are equivalent in diagnostic quality to those acquired at 150 mAs. Reduced settings can provide useful imaging of the paediatric pelvis and should be considered as a standard protocol in these situations.
Resumo:
OBJECTIVE. The purpose of the study was to investigate patient characteristics associated with image quality and their impact on the diagnostic accuracy of MDCT for the detection of coronary artery stenosis. MATERIALS AND METHODS. Two hundred ninety-one patients with a coronary artery calcification (CAC) score of <= 600 Agatston units (214 men and 77 women; mean age, 59.3 +/- 10.0 years [SD]) were analyzed. An overall image quality score was derived using an ordinal scale. The accuracy of quantitative MDCT to detect significant (>= 50%) stenoses was assessed using quantitative coronary angiography (QCA) per patient and per vessel using a modified 19-segment model. The effect of CAC, obesity, heart rate, and heart rate variability on image quality and accuracy were evaluated by multiple logistic regression. Image quality and accuracy were further analyzed in subgroups of significant predictor variables. Diagnostic analysis was determined for image quality strata using receiver operating characteristic (ROC) curves. RESULTS. Increasing body mass index (BMI) (odds ratio [OR] = 0.89, p < 0.001), increasing heart rate (OR = 0.90, p < 0.001), and the presence of breathing artifact (OR = 4.97, p = 0.001) were associated with poorer image quality whereas sex, CAC score, and heart rate variability were not. Compared with examinations of white patients, studies of black patients had significantly poorer image quality (OR = 0.58, p = 0.04). At a vessel level, CAC score (10 Agatston units) (OR = 1.03, p = 0.012) and patient age (OR = 1.02, p = 0.04) were significantly associated with the diagnostic accuracy of quantitative MDCT compared with QCA. A trend was observed in differences in the areas under the ROC curves across image quality strata at the vessel level (p = 0.08). CONCLUSION. Image quality is significantly associated with patient ethnicity, BMI, mean scan heart rate, and the presence of breathing artifact but not with CAC score at a patient level. At a vessel level, CAC score and age were associated with reduced diagnostic accuracy.
Resumo:
Lipodystrophy syndrome (LS) has been reported as visible markers that cat? identify HIV status. Changes in body shape are detrimental in terms of psychological welfare and may affect well-being and increase the stigma associated with HIV disease. In the current study, the pychosocial impact of LS was evaluated. A total of 84 HIV-infected patients receiving antiretroviral therapy and exhibiting dyslipidemia were interviewed in an urban hospital setting in Brazil in 2006 using a standardized questionnaire. Of the 84 patients exhibiting dyslipidemia, 40 patients also exhibited body changes, and of these, 25 had facial lipoatrophy. From a psychosocial perspective, patients presenting with facial lipoatrophy reported alterations in self-image and self-esteem and believed that other people noticed their body changes. The results are relevant for nurses who need to be well-prepared to recognize lipodystrophy, to implement nursing interventions including lifestyle changes, and to provide psychosocial support to patients with LS.
Resumo:
Birthweight affects neonatal mortality and morbidity and has been used as a marker of foetal undernutrition in studies of prenatal effects on adult characteristics. It is potentially influenced by genetic and environmental influences on the mother, and effects of foetal genotype, which is partially derived from the maternal genotype. Interpretations of variation in birthweight and associated characteristics as being due to prenatal environment ignore other possible modes of materno-foetal transmission. Subjects were adult twins recruited through the Australian Twin Registry, aged 17 to 87 years, and the sample comprised 1820 men and 4048 women. Twins reported their own birthweight as part of a health questionnaire. Body Mass Index (BMI) was calculated from self-reports of height and weight. Correlations between co-twins' birthweights were high for both monozygotic (r = 0.77) and dizygotic (r = 0.67) pairs, leading to substantial estimates of shared environmental effects (56% of variance) with significant additive genetic (23%) and non-shared environmental (21%) components. Adult BMI was mainly influenced by genetic factors, both additive (36% of variance) and nonadditive (35%). The correlation between birthweight and BMI was positive, in that heavier babies became on average more obese adults. A bivariate model of birthweight and adult BMI showed significant positive genetic (rg = 0.16, p = 0.005) and environmental (re = 0.08, p = 0.000011) correlations. Intra-uterine environmental or perinatal influences shared by cotwins exercise a strong influence on birthweight, but the factors which affect both birthweight and adult BMI are partly genetic and partly non-shared environmental.
Resumo:
Questionnaire surveys, while more economical, typically achieve poorer response rates than interview surveys. We used data from a national volunteer cohort of young adult twins, who were scheduled for assessment by questionnaire in 1989 and by interview in 1996-2000, to identify predictors of questionnaire non-response. Out of a total of 8536 twins, 5058 completed the questionnaire survey (59% response rate), and 6255 completed a telephone interview survey conducted a decade later (73% response rate). Multinomial logit models were fitted to the interview data to identify socioeconomic, psychiatric and health behavior correlates of non-response in the earlier questionnaire survey. Male gender, education below University level, and being a dizygotic rather than monozygotic twin, all predicted reduced likelihood of participating in the questionnaire survey. Associations between questionnaire response status and psychiatric history and health behavior variables were modest, with history of alcohol dependence and childhood conduct disorder predicting decreased probability of returning a questionnaire, and history of smoking and heavy drinking more weakly associated with non-response. Body-mass index showed no association with questionnaire non-response. Despite a poor response rate to the self-report questionnaire survey, we found only limited sampling biases for most variables. While not appropriate for studies where socioeconomic variables are critical, it appears that survey by questionnaire, with questionnaire administration by telephone to non-responders, will represent a viable strategy for gene-mapping studies requiring that large numbers of relatives be screened.