676 resultados para Body-image Dissatisfaction


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The human body occupies a central place in Rukeyser’s poetry. Her characters’ physical experiences inspire their search for an artistic form and a holistic vision that reconciles the corporeal and conceptual aspects of their life. My thesis deals with Rukeyser’s reconciliation of disparate aspects of existence through the image of the human body and the practical experiences she underwent in her personal life and incorporated in her poetry. I discuss her poetry of the 1940s, where a tension is observed between the artist’s personal life and her art, which she attempts to resolve by adopting an artistic form that accommodates her quotidian experiences. I study, mainly through her poetry of the 1950s, Rukeyser’s poetic technique in the light of her organicist poetics and the combination of tendencies to coercion and suggestiveness distinguishing her style. I examine her portrayal of the suffering body in her poetry of the 1960s and 1970s. By means of their physical experiences, the ill, her despised and the imprisoned protagonists undergo a process of development whereby they perceive the different aspects of their identity and attempt to broaden perspectives on their situation by reconciling them. I argue that Rukeyser’s engagement with physical encounters and with the poem as an inclusive, organic body enables her to reconcile disparate elements in her poetry, such as her personal life and her art, her individual existence and the public world, as well as the distinct aspects of her characters’ identity. Her vatic outlook, which integrates distinct aspects of experience, is consistent with Merleau-Ponty’s idea of human perception as characterised by the two interdependent positions of immanence and transcendence. Rukeyser’s poetry depicts her physical engagement with quotidian events of her life as a factor of artistic inspiration. These situations constitute shared human experiences that enable her to imagine the links binding her to other people and the world at large. The poet’s personal experiences inspire her search for an artistic form that accommodates them. Her perception of the concrete aspect of her individual existence gains significance when it is linked to social and political issues. Both the private and public are thus seen as interconnected, and they affect the existence of each other while retaining their distinctness.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Foreign bodies, although they are often found throughout the body, to a lesser degree in the face, still constitute a diagnostic challenge for the trauma surgeon. Its removal means danger of damaging important facial anatomic structures, even if its exact position from the image data was known. So, the objective is to describe a clinical report of a patient (42 years of age, male sex) who experienced falling to the ground, attended by the Department of Surgery and Traumatology Bucco-Maxillo-Facial Surgery, Faculty of Dentistry of Aracatuba, São Paulo State University, and 2 days after the trauma, he reported difficulty in mouth opening and pain. After clinical evaluation, we observed the presence of injury in the left preauricular region already in the process of healing. During the intraoral physical examination, a limitation of the mouth opening was noted. Radiographic posteroanterior and profile of the face showed 2 radiopaque foreign bodies in the left side, lying apparently at the region of the mandibular condylar process. Under local anesthesia, foreign body removal was carried from there with access to it through the preexisting facial injury. Further clinical examinations showed an improvement in mouth opening, absence of pain complaints, and/or functional complaints.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of this paper was to evaluate the agreement among different methods used to estimate angular deviation of the body to determine the risk for development of upper limb musculoskeletal disorders in dentistry undergraduates. Materials and Methods: Students (n = 79) enrolled in the final year undergraduate course of the Araraquara School of Dentistry-Sγo Paulo State University-UNESP were evaluated. Photographs were taken of students performing clinical procedures. The work postures adopted by each student were evaluated by means of rapid upper limb assessment (RULA). The basis used to obtain the individual's final risk score is the measurement of the angular deviations in the neutral positions of the regions evaluated. Two methods were used to estimate the angular deviation of the body: Visual exam and Image Tool software. A RULA final risk score was attributed to each procedure the student performed (n = 333). Study of the agreement between the methods about risk of musculoskeletal disorders was conducted by means of Kappa (κ) statistics. The level of significance adopted was 5%. Results: Fair agreement (κ = 0.32) between the evaluated methods was verified. Conclusion: The risk for development of upper limb musculoskeletal disorders by dentistry undergraduates evaluated by using RULA was not in agreement with the results obtained by use of visual exam and Image Tool.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of this paper was to evaluate the agreement among different methods used to estimate angular deviation of the body to determine the risk for development of upper limb musculoskeletal disorders in dentistry undergraduates. Materials and Methods: Students (n = 79) enrolled in the final year undergraduate course of the Araraquara School of Dentistry-Sγo Paulo State University-UNESP were evaluated. Photographs were taken of students performing clinical procedures. The work postures adopted by each student were evaluated by means of rapid upper limb assessment (RULA). The basis used to obtain the individual's final risk score is the measurement of the angular deviations in the neutral positions of the regions evaluated. Two methods were used to estimate the angular deviation of the body: Visual exam and Image Tool software. A RULA final risk score was attributed to each procedure the student performed (n = 333). Study of the agreement between the methods about risk of musculoskeletal disorders was conducted by means of Kappa (κ) statistics. The level of significance adopted was 5%. Results: Fair agreement (κ = 0.32) between the evaluated methods was verified. Conclusion: The risk for development of upper limb musculoskeletal disorders by dentistry undergraduates evaluated by using RULA was not in agreement with the results obtained by use of visual exam and Image Tool.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study was designed to present the feasibility of an in vivo image-guided percutaneous cryoablation of the porcine vertebral body. Methods The institutional animal care committee approved this study. Cone-beam computed tomography (CBCT)-guided vertebral cryoablations (n = 22) were performed in eight pigs with short, 2-min, single or double-freezing protocols. Protective measures to nerves included dioxide carbon (CO2) epidural injections and spinal canal temperature monitoring. Clinical, radiological, and pathological data with light (n = 20) or transmission electron (n = 2) microscopic analyses were evaluated after 6 days of clinical follow-up and euthanasia. Results CBCT/fluoroscopic-guided transpedicular vertebral body cryoprobe positioning and CO2 epidural injection were successful in all procedures. No major complications were observed in seven animals (87.5 %, n = 8). A minor complication was observed in one pig (12.5 %, n = 1). Logistic regression model analysis showed the cryoprobe-spinal canal (Cp-Sc) distance as the most efficient parameter to categorize spinal canal temperatures lower than 19 °C (p<0.004), with a significant Pearson’s correlation test (p < 0.041) between the Cp-Sc distance and the lowest spinal canal temperatures. Ablation zones encompassed pedicles and the posterior wall of the vertebral bodies with an inflammatory rim, although no inflammatory infiltrate was depicted in the surrounding neural structures at light microscopy. Ultrastructural analyses evidenced myelin sheath disruption in some large nerve fibers, although neurological deficits were not observed. Conclusions CBCT-guided vertebral cryoablation of the porcine spine is feasible under a combination of a short freezing protocol and protective measures to the surrounding nerves. Ultrastructural analyses may be helpful assess the early modifications of the nerve fibers.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Studies of subjective time have adopted different methods to understand different processes of time perception. Four sculptures, with implied movement ranked as 1.5-, 3.0-, 4.5-, and 6.0-point stimuli on the Body Movement Ranking Scale, were randomly presented to 42 university students untrained in visual arts and ballet. Participants were allowed to observe the images for any length of time (exploration time) and, immediately after each image was observed, recorded the duration as they perceived it. The results of temporal ratio (exploration time/time estimation) showed that exploration time of images also affected perception of time, i.e., the subjective time for sculptures representing implied movement were overestimated.\

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate a comprehensive MRI protocol that investigates for cancer, vascular disease, and degenerative/inflammatory disease from the head to the pelvis in less than 40 minutes on a new generation 48-channel 3T system. MATERIALS AND METHODS: All MR studies were performed on a 48-channel 3T MR scanner. A 20-channel head/neck coil, two 18-channel body arrays, and a 32-channel spine array were employed. A total of 4 healthy individuals were studied. The designed protocol included a combination of single-shot T2-weighted sequences, T1-weighted 3D gradient-echo pre- and post-gadolinium. All images were retrospectively evaluated by two radiologists independently for overall image quality. RESULTS: The image quality for cancer was rated as excellent in the liver, pancreas, kidneys, lungs, pelvic organs, and brain, and rated as fair in the colon and breast. For vascular diseases ratings were excellent in the aorta, major branch vessel origins, inferior vena cava, portal and hepatic veins, rated as good in pulmonary arteries, and as poor in the coronary arteries. For degenerative/inflammatory diseases ratings were excellent in the brain, liver and pancreas. The inter-observer agreement was excellent. CONCLUSION: A comprehensive and time efficient screening for important categories of disease processes may be achieved with high quality imaging in a new generation 48-channel 3T system.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Trabajo realizado por: Garijo, J. C., Hernández León, S.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This thesis deals with Visual Servoing and its strictly connected disciplines like projective geometry, image processing, robotics and non-linear control. More specifically the work addresses the problem to control a robotic manipulator through one of the largely used Visual Servoing techniques: the Image Based Visual Servoing (IBVS). In Image Based Visual Servoing the robot is driven by on-line performing a feedback control loop that is closed directly in the 2D space of the camera sensor. The work considers the case of a monocular system with the only camera mounted on the robot end effector (eye in hand configuration). Through IBVS the system can be positioned with respect to a 3D fixed target by minimizing the differences between its initial view and its goal view, corresponding respectively to the initial and the goal system configurations: the robot Cartesian Motion is thus generated only by means of visual informations. However, the execution of a positioning control task by IBVS is not straightforward because singularity problems may occur and local minima may be reached where the reached image is very close to the target one but the 3D positioning task is far from being fulfilled: this happens in particular for large camera displacements, when the the initial and the goal target views are noticeably different. To overcame singularity and local minima drawbacks, maintaining the good properties of IBVS robustness with respect to modeling and camera calibration errors, an opportune image path planning can be exploited. This work deals with the problem of generating opportune image plane trajectories for tracked points of the servoing control scheme (a trajectory is made of a path plus a time law). The generated image plane paths must be feasible i.e. they must be compliant with rigid body motion of the camera with respect to the object so as to avoid image jacobian singularities and local minima problems. In addition, the image planned trajectories must generate camera velocity screws which are smooth and within the allowed bounds of the robot. We will show that a scaled 3D motion planning algorithm can be devised in order to generate feasible image plane trajectories. Since the paths in the image are off-line generated it is also possible to tune the planning parameters so as to maintain the target inside the camera field of view even if, in some unfortunate cases, the feature target points would leave the camera images due to 3D robot motions. To test the validity of the proposed approach some both experiments and simulations results have been reported taking also into account the influence of noise in the path planning strategy. The experiments have been realized with a 6DOF anthropomorphic manipulator with a fire-wire camera installed on its end effector: the results demonstrate the good performances and the feasibility of the proposed approach.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Il presente lavoro di tesi è stato svolto presso il servizio di Fisica Sanitaria del Policlinico Sant'Orsola-Malpighi di Bologna. Lo studio si è concentrato sul confronto tra le tecniche di ricostruzione standard (Filtered Back Projection, FBP) e quelle iterative in Tomografia Computerizzata. Il lavoro è stato diviso in due parti: nella prima è stata analizzata la qualità delle immagini acquisite con una CT multislice (iCT 128, sistema Philips) utilizzando sia l'algoritmo FBP sia quello iterativo (nel nostro caso iDose4). Per valutare la qualità delle immagini sono stati analizzati i seguenti parametri: il Noise Power Spectrum (NPS), la Modulation Transfer Function (MTF) e il rapporto contrasto-rumore (CNR). Le prime due grandezze sono state studiate effettuando misure su un fantoccio fornito dalla ditta costruttrice, che simulava la parte body e la parte head, con due cilindri di 32 e 20 cm rispettivamente. Le misure confermano la riduzione del rumore ma in maniera differente per i diversi filtri di convoluzione utilizzati. Lo studio dell'MTF invece ha rivelato che l'utilizzo delle tecniche standard e iterative non cambia la risoluzione spaziale; infatti gli andamenti ottenuti sono perfettamente identici (a parte le differenze intrinseche nei filtri di convoluzione), a differenza di quanto dichiarato dalla ditta. Per l'analisi del CNR sono stati utilizzati due fantocci; il primo, chiamato Catphan 600 è il fantoccio utilizzato per caratterizzare i sistemi CT. Il secondo, chiamato Cirs 061 ha al suo interno degli inserti che simulano la presenza di lesioni con densità tipiche del distretto addominale. Lo studio effettuato ha evidenziato che, per entrambi i fantocci, il rapporto contrasto-rumore aumenta se si utilizza la tecnica di ricostruzione iterativa. La seconda parte del lavoro di tesi è stata quella di effettuare una valutazione della riduzione della dose prendendo in considerazione diversi protocolli utilizzati nella pratica clinica, si sono analizzati un alto numero di esami e si sono calcolati i valori medi di CTDI e DLP su un campione di esame con FBP e con iDose4. I risultati mostrano che i valori ricavati con l'utilizzo dell'algoritmo iterativo sono al di sotto dei valori DLR nazionali di riferimento e di quelli che non usano i sistemi iterativi.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The effect of copper (Cu) filtration on image quality and dose in different digital X-ray systems was investigated. Two computed radiography systems and one digital radiography detector were used. Three different polymethylmethacrylate blocks simulated the pediatric body. The effect of Cu filters of 0.1, 0.2, and 0.3 mm thickness on the entrance surface dose (ESD) and the corresponding effective doses (EDs) were measured at tube voltages of 60, 66, and 73 kV. Image quality was evaluated in a contrast-detail phantom with an automated analyzer software. Cu filters of 0.1, 0.2, and 0.3 mm thickness decreased the ESD by 25-32%, 32-39%, and 40-44%, respectively, the ranges depending on the respective tube voltages. There was no consistent decline in image quality due to increasing Cu filtration. The estimated ED of anterior-posterior (AP) chest projections was reduced by up to 23%. No relevant reduction in the ED was noted in AP radiographs of the abdomen and pelvis or in posterior-anterior radiographs of the chest. Cu filtration reduces the ESD, but generally does not reduce the effective dose. Cu filters can help protect radiosensitive superficial organs, such as the mammary glands in AP chest projections.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper reports on the application of full-body radiography to nontraumatic emergency situations. The Lodox Statscan is an X-ray machine capable of imaging the entire body in 13 seconds using linear slit scanning radiography (LSSR). Nontraumatic emergency applications in ventriculoperitoneal (VP) shunt visualisation, emergency room arteriography (ERA), detection of foreign bodies, and paediatric emergency imaging are presented. Reports show that the fast, full-body, and low-dose scanning capabilities of the Lodox system make it well suited to these applications, with the same or better image quality, faster processing times, and lower dose to patients. In particular, the large format scans allowing visualisation of a greater area of anatomy make it well suited to VP shunt monitoring, ERA, and the detection of foreign bodies. Whilst more studies are required, it can be concluded that the Lodox Statscan has the potential for widespread use in these and other nontraumatic emergency radiology applications.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: Foreign body ingestion is common and potentially lethal. This study evaluates the use of low-dose Statscans (LODOX) in emergency departments. DESIGN: This comparative cross-sectional study retrospectively assessed 28 289 digital chest x-rays and 2301 LODOX scans performed between 2006 and 2010 at a tertiary emergency centre. The radiographic appearance, image quality and location of ingested foreign bodies were evaluated in standard digital chest and LODOX radiography. The mean irradiation (μSv) and cumulative mean radiation dose per patient with the ingested foreign body were calculated according to literature-based data, together with the sensitivity and specificity for each modality. RESULTS: A total of 62 foreign bodies were detected in 39 patients, of whom 19 were investigated with LODOX and 20 with conventional digital chest radiography. Thirty-three foreign bodies were located in the two upper abdominal quadrants, 21 in the lower quadrants-which are not visible on conventional digital chest radiography-seven in the oesophagus and one in the bronchial system. The sensitivity and specificity of digital chest radiography were 44.4% and 94.1%, respectively, and for the LODOX Statscan 90% and 100%, respectively. The calculated mean radiation dose for LODOX investigations was 184 μS, compared with 524 μS for digital chest radiography. CONCLUSIONS: LODOX Statscan is superior to digital chest radiography in the diagnostic work-up of ingested foreign bodies because it makes it possible to enlarge the field of view to the entire body, has higher sensitivity and specificity, and reduces the radiation dose by 65%.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A new generation of high definition computed tomography (HDCT) 64-slice devices complemented by a new iterative image reconstruction algorithm-adaptive statistical iterative reconstruction, offer substantially higher resolution compared to standard definition CT (SDCT) scanners. As high resolution confers higher noise we have compared image quality and radiation dose of coronary computed tomography angiography (CCTA) from HDCT versus SDCT. Consecutive patients (n = 93) underwent HDCT, and were compared to 93 patients who had previously undergone CCTA with SDCT matched for heart rate (HR), HR variability and body mass index (BMI). Tube voltage and current were adapted to the patient's BMI, using identical protocols in both groups. The image quality of all CCTA scans was evaluated by two independent readers in all coronary segments using a 4-point scale (1, excellent image quality; 2, blurring of the vessel wall; 3, image with artefacts but evaluative; 4, non-evaluative). Effective radiation dose was calculated from DLP multiplied by a conversion factor (0.014 mSv/mGy × cm). The mean image quality score from HDCT versus SDCT was comparable (2.02 ± 0.68 vs. 2.00 ± 0.76). Mean effective radiation dose did not significantly differ between HDCT (1.7 ± 0.6 mSv, range 1.0-3.7 mSv) and SDCT (1.9 ± 0.8 mSv, range 0.8-5.5 mSv; P = n.s.). HDCT scanners allow low-dose 64-slice CCTA scanning with higher resolution than SDCT but maintained image quality and equally low radiation dose. Whether this will translate into higher accuracy of HDCT for CAD detection remains to be evaluated.