984 resultados para Blood Donation
Resumo:
Serological survey was performed to detect IgG antibodies anti-Taenia solium metacestodes in blood donors of Hemocentro Regional de Uberlândia, Minas Gerais, Brazil. A total of 1133 sera from blood donors coming from four cities of Triângulo Mineiro area were analyzed by the indirect fluorescence antibody test (IFAT) and the enzyme linked immunosorbent assay (ELISA). Specific IgG antibodies were found in 5.6% of the studied population, showing differences in the positive rates according to their origin: Araguari (13.5%), Tupaciguara (5.0%), Monte Alegre de Minas (4.8%) and Uberlândia (4.7%). The results indicate the probable endemicity of cysticercosis in this population.
Resumo:
This study evaluated the usefulness of the anti-HBc, hepatitis C virus antibodies (anti-HCV), human T cell lymphotropic virus I and II antibodies (anti-HTLV I/II), serologic tests for syphilis, and surface antigen of hepatitis B virus (HBsAg) as surrogate markers for the risk for HIV infection in 80,284 serum samples from blood donors from the Blood Bank of "Hospital Universitário Regional Norte do Paraná", Londrina, Paraná State, Brazil, analyzed from July 1994 to April 2001. Among 39 blood donors with positive serology for HIV, 12 (30.8%) were anti-HBc positive, 10 (25.6%) for anti-HCV, 1 (2.6%) for anti-HTLV I/I, 1 (2.6%) was positive for syphilis, and 1 (2.6%) for HBsAg. Among the donors with negative serology for HIV, these markers were detected in 8,407 (10.5%), 441 (0.5%), 189 (0.2%), 464 (0.6%), and 473 (0.6%) samples, respectively. The difference was statistically significant (p < 0.001) for anti-HBc and anti-HCV. Although the predictive positive value for these surrogate markers were low for HIV infection, the results confirmed the anti-HBc and anti-HCV as useful surrogate markers for HIV infection thus reinforcing the maintenance of them in the screening for blood donors contributing to the prevention of the small number of cases in which HIV is still transmitted by transfusion.
Resumo:
The aim of this study was to investigate the presence of the Hepatitis G Virus on a population of blood donors from São Paulo, Brazil and to evaluate its association to sociodemographic variables. Two RT-PCR systems targeting the putative 5'NCR and NS3 regions were employed and the former has shown a higher sensitivity. The observed prevalence of HGV-RNA on 545 blood donors was 9.7% (CI 95% 7.4;12.5). Statistical analysis depicted an association with race/ethnicity, black and mulatto donors being more frequently infected; and also with years of education, less educated donors presenting higher prevalences. No association was observed with other sociodemographic parameters as age, gender, place of birth and of residence. DNA sequencing of nine randomly chosen isolates demonstrated the presence of genotypes 1, 2 and 3 among our population but clustering of these Brazilian isolates was not detected upon phylogenetic analysis.
Resumo:
This study evaluated the whole blood immunochromatographic card test (ICT card test) in a survey performed in Northeastern Brazil. 625 people were examined by the thick blood film (TBF) and ICT card test. Residents of a non-endemic area were also tested by the whole blood card test and Og4C3. The sensitivity of the ICT card test was 94.7% overall, but lower in females than males, based on the reasonable assumption that TBF is 100% specific. However, since TBF and other methods have unknown sensitivity, the true specificity of the card test is unknown. Nevertheless, it is possible to estimate upper and lower limits for the specificity, and relate it to the prevalence of the disease. In the endemic area, the possible range of the specificity was from 72.4% to 100%. 29.6% of the card tests performed in the non-endemic area exhibited faint lines that were interpreted as positives. Characteristics of the method including high sensitivity, promptness and simplicity justify its use for screening of filariasis. However, detailed information about the correct interpretation in case of extremely faint lines is essential. Further studies designed to consider problems arising from imperfect standards are necessary, as is a sounder diagnostic definition for the card test.
Resumo:
In order to assess the potential risk of anti-HBc-positive blood donors for post-transfusional hepatitis and to investigate whether other HBV serological markers are capable of identifying the presence of the virus, 1000 first-time blood donors were enrolled between June and July 1997. These donors were screened using routine Brazilian blood center tests (HIV 1 and 2, HTLV 1 and 2, Chagas disease, Syphilis, HCV, HBsAg, anti-HBc and ALT ). The 120 (12%) found to be anti-HBc-positive underwent further tests: HBe, anti-HBe, anti-HBs and HBV-DNA by PCR. Ten cases were HBsAg positive and all were HBV-DNA positive by PCR. Three HBsAg-negative donors were HBV-DNA-positive. Two HBV-DNA-positive donors were also anti-HBs-positive. All the HBV-positive donors had at least one HBV marker other than anti-HBc. Anti-HBc is an important cause of blood rejection. Testing for HBsAg alone is not fully protective and anti-HBc remains necessary as a screening test. The presence of anti-HBs is not always indicative of absence of the virus. The addition of other HBV serological markers could represent an alternative in predicting the presence of the virus when compared with PCR. It is recommended that other studies should be carried out to confirm this finding.
Resumo:
A serological survey of Toxoplasma gondii infection in blood donors was carried out in order to identify seroprevalence in Recife, Brazil. Sera from 160 individuals (119 male and 41 female) were evaluated by using a Toxoplasma IgG-antibody enzyme immunoassay (Denka Seiken Co., LTD., Tokyo, Japan). The seropositive percentual for males (79.0%) showed to be higher (p < 0.05) than for females (63.4%). This percentage increases with age, ranging from 18.2% to 92.6% for individuals aging under 20 and 40-50 years old, respectively. For women of childbearing age (18-40 years) it was found a prevalence of 51.6%.
Resumo:
In order to evaluate the potential allergenicity of Blomia tropicalis (Bt) antigen, IgE production of both specific and non-specific for Bt antigen was monitored in BALB/c mice after exposure to the antigen by nasal route. It was evidenced that B. tropicalis contains a functional allergen in its components. The allergenic components, however, when administered intranasally without any adjuvant, did not function to induce IgE response within a short period. On the other hand, intranasal inoculation of Bt antigens augmented serum IgE responses in mice pretreated by a subcutaneous priming injection of the same antigens. Inoculation of Bt antigen without subcutaneous priming injections induced IgE antibody production only when the antigen was continuously administered for a long period of over 24 weeks. Even when the priming injection was absent, the Bt antigen inoculated with cholera toxin (CT) as a mucosal adjuvant also significantly augmented the Bt antigen-specific IgE responses depending on the dose of CT co-administered. The present study also demonstrated that Bt antigen/CT-inoculated mice showed increased non-specific serum IgE level and peripheral blood eosinophil rates without noticeable elevations of the total leukocyte counts. The immunoblot analysis demonstrated 5 main antigenic components reactive to IgE antibodies induced. These components at about 44-64 kDa position were considered to be an important candidate antigen for diagnosis of the mite-related allergy.
Resumo:
The aim of the present study was to screen the serum of blood donors, which are apparently healthy and residing in Pondicherry or its neighboring districts of Tamil Nadu State, for specific detection of Cysticercus antigens and antibodies. A total of 216 blood samples were collected from blood donors at the Central Blood Bank, JIPMER Hospital, Pondicherry, India during January and February 2004. Enzyme-linked immunosorbent assay (ELISA) was used to demonstrate anti-Cysticercus antibodies and the Co-agglutination (CoA) was used to detect antigen in sera. 14 (6.48 %) males were positive for either anti-Cysticercus antibodies or antigens. Of these eight sera were positive for anti-Cysticercus antibodies and six were positive for antigens. Results of the present study show that serum Cysticercus antigen detection may be a useful adjunct to antibody testing for seroprevalence studies of cysticercosis in the community. The present study is the first kind of study, carried out to determine both cysticercal antibodies as well as antigens in the serum samples collected from the healthy blood donors.
Resumo:
To describe the epidemiologic profile and prevalence of cardiopathy in 163 Trypanosoma cruzi serum positive blood donor candidates, a descriptive study was carried out between August, 1996 and November, 1997 at the Londrina State University Chagas Disease Outpatient Clinic. The profile found was: young, average age 42.95 ± 8.62 years; male (65%); Caucasian (84%); low level of schooling; low family income; agricultural worker (26%); born in the state of Paraná (67%); from rural areas (85%); migrated to the city (85%); and the vector as the main mechanism of transmission. During the clinical characterization a chronic cardiac form was found in 38% of the patients and classified as cardiac suggestive form in 21% and little suggestive of Chagas disease in 17%. No significant difference was found among age group distribution, sex and the presence of cardiac symptoms in patients with or without cardiopathy. This study emphasizes the importance of expanding medical services to areas with a greater prevalence of infected individuals, in a hierarchical manner and aiming at decentralization.
Resumo:
In order to investigate the hepatitis C virus (HCV) genotypes in mid-west region of Brazil, 250 anti-HCV positive blood donors were studied. Among them, the anti-HCV serological status was confirmed in 205 (82%). HCV RNA was detected in 165 samples, which were genotyped. HCV types 1, 2 and 3 were found in 67.9%, 3% and 29.1% of the donors, respectively. In Goiás state, subtype 1a (50%) was the most prevalent, followed by subtypes 3a (30.9%) and 1b (16.7%). In Mato Grosso state, subtype 1a was also predominant (41%), followed by subtypes 1b (29.5%) and 3a (25%). In Mato Grosso do Sul state, subtypes 1a and 1b were detected equally (36.8%), followed by 3a (21.1%). Subtype 2b was rare (2.4%, 4.5% and 5.3%, respectively). In Distrito Federal, subtype 3a (39%) was more frequent than 1a (31.7%) and the remaining (29.3%) belonged to subtype 1b.
Resumo:
A cross-sectional study was carried out among 996 volunteer blood donors enrolled from May 1999 to December 1999 to determine the seroprevalence of hepatitis E virus (HEV) infection among volunteer blood donors of the Regional Blood Bank of Londrina, State of Paraná, Brazil, and to evaluate whether the rate of seroprevalence of IgG anti-HEV antibodies is associated with sociodemographic variables and with seropositivity for hepatitis A virus (HAV) infection. All participants answered the questionnaire regarding the sociodemographic characterisitcs. Serum samples were tested for IgG antibodies to HEV (anti-HEV) by an enzyme linked immunoassay (ELISA). All serum samples positive for anti-HEV IgG and 237 serum samples negative for anti-HEV were also assayed for IgG anti-HAV antibodies by ELISA. Anti-HEV IgG was confirmed in 23/996 samples, resulting in a seroprevalence of 2.3% for HEV infection, similar to previous results obtained in developed countries. No significant association was found between the presence of anti-HEV IgG antibodies and the sociodemographic variables including gender, age, educational level, rural or urban areas, source of water, and sewer system (p > 0.05). Also, no association with seropositivity for anti-HAV IgG antibodies was observed (p > 0.05). Although this study revealed a low seroprevalence of HEV infection in the population evaluated, the results showed that this virus is circulating among the population from Londrina, South Brazil, and point out the need of further studies to define the clinical and epidemiological importance of HEV infection and to identify additional risk factors involved in the epidemiology and pathogenesis of this infection in this population.
Resumo:
Progressive disseminated histoplasmosis (PDH) is an increasingly common cause of infection in patients with acquired immune deficiency syndrome (AIDS). We report 21 cases of PDH associated with AIDS diagnosed by lysis-centrifugation blood culture method. The most prevalent clinical findings were fever, weight loss, respiratory symptoms, and mucocutaneous lesions. Chest roentgenogram showed diffuse pulmonary infiltrates in 13 of 21 patients (62%). Brochoalveolar fluid has yelded positive culture in four patients only in medium with cycloheximide.
Resumo:
Human Immunodeficiency Vírus Type 1 and 2 antibodies detection was performed in 457 dried whole blood spots samples (S&S 903). Q-Preven HIV 1+2 was the screening test used. The results were compared with the gold standard serum tests by ELISA (Cobas Core e Axsym HIV1/2 gO) and imunofluorescence was the definitive confirmatory test. The samples were obtained from the Hospital Nossa Senhora da Conceição in Porto Alegre, RS - Brazil, through whole blood transfer to filter paper card and sent to Caxias do Sul, RS - Brazil where the tests were performed. The dried whole blood spot stability was evaluated with two different panels. The first one was composed of five negative and five positive samples stored at room temperature, 4 ºC, -20 ºC and -70 ºC, while the second was composed of two negative and three positive samples stored at 37 ºC (humidity <50%). Each sample was screened every week for six weeks. These measurement results didn't show variation during the study period. The detected sensibility was 100%, specificity was 99.6%, the positive predictive value was 99.5% and negative predictive values were 100%. The results demonstrated high performance characteristics, opening a new perspective of dried whole blood spot utilization in HIV screening diagnosis.