941 resultados para Aortic Coarctation
Resumo:
The effect of varying injection rates of a saline chaser on aortic enhancement in computed tomography (CT) angiography was determined. Single-level, dynamic CT images of a physiological flow phantom were acquired between 0 and 50 s after initiation of contrast medium injection. Four injection protocols were applied with identical contrast medium administration (150 ml injected at 5 ml/s). For baseline protocol A, no saline chaser was applied. For protocols B, C, and D, 50 ml of saline was injected at 2.5 ml/s, 5 ml/s, and 10 ml/s, respectively. Injecting the saline chaser at twice the rate as the contrast medium yielded significantly higher peak aortic enhancement values than injecting the saline at half or at the same rate as the contrast medium (P < 0.05). Average peak aortic enhancement (HU) measured 214, 214, 218, and 226 for protocols A, B, C, and D, respectively. The slower the saline-chaser injection rate, the longer the duration of 90% peak enhancement: 13.6, 12.2, and 11.7 s for protocols B, C, and D, respectively (P > 0.05). In CT angiography, saline chaser injected at twice the rate as the contrast medium leads to increased peak aortic enhancement and saline chaser injected at half the rate tends towards prolonging peak aortic enhancement plateau.
Resumo:
BACKGROUND: Purpose of this study was to compare the correlation of statin use with long-term mortality in patients with abdominal (AAA) and thoracic aortic aneurysm (TAA). PATIENTS AND METHODS: We compared long-term survival of 731 AAA and 59 TAA patients undergoing elective endovascular repair (EVAR). Kaplan-Meier survival curves were compared by the log-rank method. Propensity score-adjusted multivariable logistic regression models were used to determine independent associations of statin use on vital status after EVAR. RESULTS: Statin use was associated with decreased long-term mortality in AAA patients in bivariate and multivariable regression analysis, in which the effect of propensity to receive a statin was considered (adjusted HR: .613, 95%-CI: .379- .993, p = .047) whereas mortality of TAA patients was not associated with use of statins (adjusted HR: 1.795, 95%-CI: .147 -21.942, p = .647). CONCLUSIONS: Use of statins is an independent predictor of decreased mortality after elective EVAR in AAA, but not in TAA patients. These findings indirectly support the concept of a distinct pathogenesis of AAA and TAA.
Resumo:
Continuing aortic neck dilatation, most probably an expression of ongoing aneurysmal wall degeneration of the infrarenal aortic segment, has been shown to seriously impair clinical results after endovascular abdominal aortic aneurysm repair. However, conflicting data on the extent and clinical relevance on this observation have recently been published. This article reviews the recent literature, summarizing our current understanding of the role of aortic neck dilatation after open surgical and endovascular abdominal aortic aneurysm repair. In addition, differences in methodology of studies on aortic neck dilatation are highlighted.
Resumo:
PURPOSE: To quantify the interobserver variability of abdominal aortic aneurysm (AAA) neck length and angulation measurements. MATERIALS AND METHODS: A total of 25 consecutive patients scheduled for endovascular AAA repair underwent follow-up 64-row computed tomographic (CT) angiography in 0.625-mm collimation. AAA neck length and angulation were determined by four blinded, independent readers. AAA neck length was defined as the longitudinal distance between the first transverse CT slice directly distal to the lowermost renal artery and the first transverse CT slice that showed at least a 15% larger outer aortic wall diameter versus the diameter measured directly below the lowermost renal artery. Infrarenal AAA neck angulation was defined as the true angle between the longitudinal axis of the proximal AAA neck and the longitudinal axis of the AAA lumen as analyzed on three-dimensional CT reconstructions. RESULTS: Mean deviation in aortic neck length determination was 32.3% and that in aortic neck angulation was 32.1%. Interobserver variability of aortic neck length and angulation measurements was considerable: in any reader combination, at least one measurement difference was outside the predefined limits of agreement. CONCLUSIONS: Assessment of the longitudinal extension and angulation of the infrarenal aortic neck is associated with substantial observer variability, even if measurement is carried out according to a standardized protocol. Further studies are mandatory to assess dedicated technical approaches to minimize variance in the determination of the longitudinal extension and angulation of the infrarenal aortic neck.
Resumo:
PURPOSE: To compare clinical outcomes of endovascular and open aortic repair of abdominal aortic aneurysms (AAAs) in young patients at low risk. It was hypothesized that endovascular aneurysm repair (EVAR) compares favorably with open aneurysm repair (OAR) in these patients. MATERIALS AND METHODS: Twenty-five patients aged 65 years or younger with a low perioperative surgical risk profile underwent EVAR at a single institution between April 1994 and May 2007 (23 men; mean age, 62 years+/-2.8). A sex- and risk-matched control group of 25 consecutive patients aged 65 years or younger who underwent OAR was used as a control group (23 men; mean age, 59 years+/-3.9). Patient outcomes and complications were classified according to Society of Vascular Surgery/International Society for Cardiovascular Surgery reporting standards. RESULTS: Mean follow-up times were 7.1 years+/-3.2 after EVAR and 5.9 years+/-1.8 after OAR (P=.1020). Total complication rates were 20% after EVAR and 52% after OAR (P=.0378), and all complications were mild or moderate. Mean intensive care unit times were 0.2 days+/-0.4 after EVAR and 1.1 days+/-0.4 after OAR (P<.0001) and mean lengths of hospital stay were 2.3 days+/-1.0 after EVAR and 5.0 days+/-2.1 after OAR (P<.0001). Cumulative rates of long-term patient survival did not differ between EVAR and OAR (P=.144). No AAA-related deaths or aortoiliac ruptures occurred during follow-up for EVAR and OAR. In addition, no surgical conversions were necessary in EVAR recipients. Cumulative rates of freedom from secondary procedures were not significantly different between the EVAR and OAR groups (P=.418). Within a multivariable Cox proportional-hazards analysis adjusted for patient age, maximum AAA diameter, and cardiac risk score, all-cause mortality rates (odds ratio [OR], 0.125; 95% CI, 0.010-1.493; P=.100) and need for secondary procedures (OR, 5.014; 95% CI, 0.325-77.410; P=.537) were not different between EVAR and OAR. CONCLUSIONS: Results from this observational study indicate that EVAR offers a favorable alternative to OAR in young patients at low risk.
Resumo:
AIMS: To describe the procedural performance and 30-day outcomes following implantation using the 18 Fr CoreValve Revalving System (CRS) as part of the multicentre, expanded evaluation registry, 1-year after obtaining CE mark approval. METHODS AND RESULTS: Patients with symptomatic severe aortic stenosis and logistic Euroscore > or =15%, or age > or =75 years, or age > or =65 years associated with pre-defined risk factors, and for whom a physician proctor and a clinical specialist were in attendance during the implantation and who collected the clinical data, were included. From April 2007, to April 2008, 646 patients with a mean age of 81 +/- 6.6 years, mean aortic valve area 0.6 +/- 0.2 cm2, and logistic EuroSCORE of 23.1 +/- 13.8% were recruited. After valve implantation, the mean transaortic valve gradient decreased from 49.4 +/- 13.9 to 3 +/- 2 mmHg. All patients had paravalvular aortic regurgitation < or = grade 2. The rate of procedural success was 97%. The procedural mortality rate was 1.5%. At 30 days, the all-cause mortality rate (i.e, including procedural) was 8% and the combined rate of death, stroke and myocardial infarction was 9.3%. CONCLUSIONS: The results of this study demonstrate the high rate of procedural success and a low 30-day mortality in a large cohort of high-risk patients undergoing transcatheter aortic valve implantation (TAVI) with the CRS.
Resumo:
OBJECTIVE: The success of open and endovascular repair of abdominal aortic aneurysms (AAA) is hampered by postoperative dilatation of the anatomical neck of the AAA, which is used for graft attachment. The purpose of this study was to determine whether the macroscopically non-diseased infrarenal aortic neck of AAA is histologically and biochemically altered at the time of operative repair. METHODS: We harvested full-thickness aortic wall samples as longitudinal stripes spanning from AAA neck to aneurysmal sac in 22 consecutive patients undergoing open surgical AAA repair. Control tissue was obtained from five organ donors and five deceased subjects undergoing autopsy without evidence of aneurysmal disease. We assessed aortic media thickness, number of intact elastic lamellar units, media destruction, and neovascularization grade and performed immunohistochemistry for matrix metalloproteinase (MMP)-9 and phosphorylated c-Jun N-terminal kinase (p-JNK). MMP-9 and p-JNK protein expressions were quantified using Western Blots. RESULTS: The median thickness of the aortic media was 1150 mum in control tissue (range, 1000-1300), 510 mum in aortic necks (250-900), and 200 mum in aortic sacs (50-500, P from nonparametric test for trend <.001). The number of intact elastic lamellar units was 33 in controls (range, 33-55), 12 in aortic necks (0-31) and three in aortic sacs (0-10, P < .001). The expression of MMP-9 and p-JNK as assessed by Western Blots (P = .007 and .061, respectively) and zymography (P for trend <.001) were up regulated in both the AAA neck and sac compared with controls. Except for p-JNK expression, differences between tissues were similar after the adjustment for age, gender, and type of sampling. CONCLUSION: The seemingly non-diseased infrarenal AAA neck in patients with AAA undergoing surgical repair shows histological signs of destruction and upregulation of potential drug targets.
Resumo:
This study compares MRI and MDCT for endoleak detection after endovascular repair of abdominal aortic aneurysms (EVAR). Forty-three patients with previous EVAR underwent both MRI (2D T1-FFE unenhanced and contrast-enhanced; 3D triphasic contrast-enhanced) and 16-slice MDCT (unenhanced and biphasic contrast-enhanced) within 1 week of each other for endoleak detection. MRI was performed by using a high-relaxivity contrast medium (gadobenate dimeglumine, MultiHance). Two blinded, independent observers evaluated MRI and MDCT separately. Consensus reading of MRI and MDCT studies was defined as reference standard. Sensitivity, specificity, and accuracy were calculated and Cohen's k statistics were used to estimate agreement between readers. Twenty endoleaks were detected in 18 patients at consensus reading (12 type II and 8 indeterminate endoleaks). Sensitivity, specificity, and accuracy for endoleak detection were 100%, 92%, and 96%, respectively, for reader 1 (95%, 81%, 87% for reader 2) for MRI and 55%, 100%, and 80% for reader 1 (60%, 100%, 82% for reader 2) for MDCT. Interobserver agreement was excellent for MDCT (k = 0.96) and good for MRI (k = 0.81). MRI with the use of a high-relaxivity contrast agent is significantly superior in the detection of endoleaks after EVAR compared with MDCT. MRI may therefore become the preferred technique for patient follow-up after EVAR.
Resumo:
OBJECTIVE: The implantation of a composite graft is the treatment of choice for patients with aortic root disease if the valve cannot be preserved and the patient is not a suitable candidate for a Ross procedure. Several years ago, the Shelhigh NR-2000C (Shelhigh, Inc, Millburn, NJ) was introduced in Europe. Being a totally biologic conduit and considering the lack of homografts, the graft seemed an ideal conduit for patients with destructive endocarditis, as well as for older patients who were not suitable candidates for oral anticoagulation. METHODS: From 2001 until 2006, the Shelhigh NR-2000C stentless valved conduit was implanted in 115 patients for various aortic root pathologies. The conduit consists of a bovine pericardial straight graft with an incorporated porcine stentless valve. Aortic root repair was performed during standard cardiopulmonary bypass and mild hypothermia in the majority of patients. Deep hypothermic circulatory arrest combined with selective antegrade cerebral perfusion was used when the repair extended into the arch. RESULTS: Seven patients with uncomplicated early outcome presented with unexpected sudden disastrous findings at the level of the aortic root, although 1-year follow-up computed tomographic scans were normal. Four of these patients underwent emergency operations because of desintegration of the graft, along with rupture of the aortic root. Retrospectively, the main findings were persistent fever or subfebrility over months and a halo-like enhancement on computed tomographic scans. Extensive microbiologic examinations were performed without finding a causative organism. CONCLUSION: The use of the Shelhigh aortic stentless conduit can no longer be advocated, and meticulous follow-up of patients in whom this device has been implanted has to be recommended.
Resumo:
OBJECTIVES: Endovascular repair of the descending thoracic aorta is a very promising technique in elective and, particularly, emergency situations. This study assessed the impact of urgency of the procedure on outcome and mid-term quality of life in surviving patients. METHODS: Post hoc analysis of prospectively collected data of 58 consecutive patients (January 2001-December 2005) with surgical pathologies of the descending thoracic aorta treated by endovascular means. Six patients were excluded due to recent operations on the ascending aorta before thoracic endovascular repair. The remaining patients (n=52) were 69+/-10 years old, and 43 were men (83%). Twenty-seven had been treated electively, and 25 for emergency indications. Reasons for emergency were acute type B aortic dissections with or without malperfusion syndrome in 14, and aortic ruptures in 11 cases. Follow-up was 29+/-16 months. Endpoints were perioperative and late morbidity and mortality rates and long-term quality of life as assessed by the short form health survey (SF-36) and Hospital Anxiety and Depression Scale questionnaires. RESULTS: Cohorts were comparable regarding age, sex, cardiovascular risk factors, and comorbidities. Perioperative mortality was somewhat higher in emergency cases (12% vs 4%, p=0.34). Paraplegia occurred in one patient in each cohort (4%). Overall quality of life after two and a half years was similar in both treatment cohorts: 72 (58-124) after emergency, and 85 (61-105) after elective endovascular aortic repair (p=0.98). Normal scores range from 85 to 115. Anxiety and depression scores were in the normal range and comparable. CONCLUSIONS: Thoracic endovascular aortic repair is an excellent and safe treatment option for the diseased descending aorta, particularly in emergency situations. Early morbidity and mortality rates can be kept very low. Mid-term quality of life was not affected by the urgency of the procedure. Similarly, mid-term anxiety and depression scores were not increased after emergency situations.
Resumo:
BACKGROUND: Thoracic endovascular aortic repair (TEVAR) represents an attractive alternative to open aortic repair (OAR). The aim of this study was to assess outcome and quality of life in patients treated either by TEVAR or OAR for diseased descending thoracic aorta. METHODS: A post hoc analysis of a prospectively collected consecutive series of 136 patients presenting with surgical diseases of the descending aorta between January 2001 and December 2005 was conducted. Fourteen patients were excluded because of involvement of the ascending aorta. Assessed treatment cohorts were TEVAR (n = 52) and OAR (n = 70). Mean follow-up was 34 +/- 18 months. End points were perioperative and late mortality rates and long-term quality of life as assessed by the Short Form Health Survey (SF-36) and Hospital Anxiety and Depression Score questionnaires. RESULTS: Mean age was significantly higher in TEVAR patients (69 +/- 10 years versus 62 +/- 15 years; p = 0.002). Perioperative mortality rates were 9% (OAR) and 8% (TEVAR), respectively (p = 0.254). Accordingly, cumulative long-term mortality rates were similar in both cohorts. Overall quality-of-life scores were 93 (63-110, OAR) and 83 (60-112, TEVAR), respectively. Normal quality-of-life scores range from 85 to 115. Anxiety and depression scores were not increased after open surgery. CONCLUSIONS: Thoracic endovascular aortic repair and OAR both provide excellent long-term results in treatment of thoracic aortic disease. Long-term quality of life, however, is reduced after thoracic aortic repair. Interestingly, TEVAR patients did not score higher in overall quality of life despite all advantages of minimized access trauma. Similarly, anxiety and depression scores are not reduced by TEVAR, possibly reflecting a certain caution against the new technology.