851 resultados para Adverse Drug Reaction Reporting Systems


Relevância:

40.00% 40.00%

Publicador:

Resumo:

Novel mucoadhesive formulations containing hydroxyethylcellulose (HEC; 3 and 5%, w/w) or Carbopol (3 and 5%, w/w), polycarbophil (PC; 1 and 3%, w/w) and metronidazole (5%, w/w) at pH 6.8 were designed for the treatment of periodontal diseases. Each formulation was characterised in terms of hardness, compressibility, adhesiveness and cohesiveness (using Texture Profile Analysis), drug release, adhesion to a mucin disc (measured as a detachment force using the texture analyser in tensile mode) and, finally, syringeability (using the texture analyser in compression mode). Drug release from all formulations was non-diffusion controlled. Drug release was significantly decreased as the concentration of each polymeric component was increased, due to both the concomitant increased viscosity of the formulations and, additionally, the swelling kinetics of PC following contact with dissolution fluid. Increasing the concentrations of each polymeric component significantly increased formulation hardness, compressibility, adhesiveness, mucoadhesion and syringeability, yet decreased cohesiveness. Increased product hardness, compressibility and syringeability were due to polymeric effects on formulation viscosity. The effects on cohesiveness may be explained both by increased viscosity and also by the increasing semi-solid nature of products containing 5% HEC or Carbopol and PC (1 or 3%). The observations concerning formulation adhesiveness/mucoadhesion illustrate the adhesive nature of each polymeric component. Greatest adhesion was noted in formulations where neutralisation of PC was maximally suppressed. For the most part, increased time of contact between formulation and mucin significantly increased the required force of detachment, due to the greater extent of mucin polymer hydration and interpenetration with the formulations. Significant statistical interactions were observed between the effects of each polymer on drug release and mechanical/mucoadhesive properties. These interactions may be explained by formulatory effects on the extent of swelling of PC. In conclusion, the formulations described offered a wide range of mechanical and drug release characteristics. Formulations containing HEC exhibited superior physical characteristics for improved drug delivery to the periodontal pocket and are now the subject of long-term clinical investigations. (C) 1997 Elsevier Science B.V.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Chemotherapy response rates for advanced colorectal cancer remain disappointingly low, primarily because of drug resistance, so there is an urgent need to improve current treatment strategies. To identify novel determinants of resistance to the clinically relevant drugs 5-fluorouracil (5-FU) and SN38 (the active metabolite of irinotecan), transcriptional profiling experiments were carried out on pretreatment metastatic colorectal cancer biopsies and HCT116 parental and chemotherapy-resistant cell line models using a disease-specific DNA microarray. To enrich for potential chemoresistance-determining genes, an unsupervised bioinformatics approach was used, and 50 genes were selected and then functionally assessed using custom-designed short interfering RNA(siRNA) screens. In the primary siRNA screen, silencing of 21 genes sensitized HCT116 cells to either 5-FU or SN38 treatment. Three genes (RAPGEF2, PTRF, and SART1) were selected for further analysis in a panel of 5 colorectal cancer cell lines. Silencing SART1 sensitized all 5 cell lines to 5-FU treatment and 4/5 cell lines to SN38 treatment. However, silencing of RAPGEF2 or PTRF had no significant effect on 5-FU or SN38 sensitivity in the wider cell line panel. Further functional analysis of SART1 showed that its silencing induced apoptosis that was caspase-8 dependent. Furthermore, silencing of SART1 led to a downregulation of the caspase-8 inhibitor, c-FLIP, which we have previously shown is a key determinant of drug resistance in colorectal cancer. This study shows the power of systems biology approaches for identifying novel genes that regulate drug resistance and identifies SART1 as a previously unidentified regulator of c-FLIP and drug-induced activation of caspase-8. Mol Cancer Ther; 11(1); 119-31. (C) 2011 AACR.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Poly(vinyl alcohol)-tetrahydroxyborate (PVA-THB) hydrogels are dilatant formulations with potential for topical wound management. To support this contention, the physical properties, rheological behaviour and component release of candidate formulations were investigated. Oscillatory rheometry and texture profile analysis were used at room temperature and 37 °C. Results showed that it was possible to control the rheological and textural properties by altering component concentration and modifying the type of PVA polymer used. Hydrogels made using PVA grades with higher degrees of hydrolysis displayed favourable characteristics from a wound healing perspective. In vitro release of borate and PVA were assessed in order to evaluate potential clinical dosing of free species originating from the hydrogel structure. Component diffusion was influenced by both concentration and molecular weight, where relevant, with up to 5% free PVA cumulative release observed after 30 min. The results of this study demonstrated the importance of poly(vinyl alcohol) selection for ensuring appropriate gel formation in PVA-THB hydrogels. The benefits of higher degrees of hydrolysis, in particular, included lower excipient release and reduced bioadhesion. The unique physical characteristics of these hydrogels make them an appealing delivery vehicle for chronic and acute wound management purposes.

Relevância:

40.00% 40.00%

Publicador:

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Background: There is growing interest in the potential utility of real-time polymerase chain reaction (PCR) in diagnosing bloodstream infection by detecting pathogen deoxyribonucleic acid (DNA) in blood samples within a few hours. SeptiFast (Roche Diagnostics GmBH, Mannheim, Germany) is a multipathogen probe-based system targeting ribosomal DNA sequences of bacteria and fungi. It detects and identifies the commonest pathogens causing bloodstream infection. As background to this study, we report a systematic review of Phase III diagnostic accuracy studies of SeptiFast, which reveals uncertainty about its likely clinical utility based on widespread evidence of deficiencies in study design and reporting with a high risk of bias. 

Objective: Determine the accuracy of SeptiFast real-time PCR for the detection of health-care-associated bloodstream infection, against standard microbiological culture. 

Design: Prospective multicentre Phase III clinical diagnostic accuracy study using the standards for the reporting of diagnostic accuracy studies criteria. 

Setting: Critical care departments within NHS hospitals in the north-west of England. 

Participants: Adult patients requiring blood culture (BC) when developing new signs of systemic inflammation. 

Main outcome measures: SeptiFast real-time PCR results at species/genus level compared with microbiological culture in association with independent adjudication of infection. Metrics of diagnostic accuracy were derived including sensitivity, specificity, likelihood ratios and predictive values, with their 95% confidence intervals (CIs). Latent class analysis was used to explore the diagnostic performance of culture as a reference standard. 

Results: Of 1006 new patient episodes of systemic inflammation in 853 patients, 922 (92%) met the inclusion criteria and provided sufficient information for analysis. Index test assay failure occurred on 69 (7%) occasions. Adult patients had been exposed to a median of 8 days (interquartile range 4–16 days) of hospital care, had high levels of organ support activities and recent antibiotic exposure. SeptiFast real-time PCR, when compared with culture-proven bloodstream infection at species/genus level, had better specificity (85.8%, 95% CI 83.3% to 88.1%) than sensitivity (50%, 95% CI 39.1% to 60.8%). When compared with pooled diagnostic metrics derived from our systematic review, our clinical study revealed lower test accuracy of SeptiFast real-time PCR, mainly as a result of low diagnostic sensitivity. There was a low prevalence of BC-proven pathogens in these patients (9.2%, 95% CI 7.4% to 11.2%) such that the post-test probabilities of both a positive (26.3%, 95% CI 19.8% to 33.7%) and a negative SeptiFast test (5.6%, 95% CI 4.1% to 7.4%) indicate the potential limitations of this technology in the diagnosis of bloodstream infection. However, latent class analysis indicates that BC has a low sensitivity, questioning its relevance as a reference test in this setting. Using this analysis approach, the sensitivity of the SeptiFast test was low but also appeared significantly better than BC. Blood samples identified as positive by either culture or SeptiFast real-time PCR were associated with a high probability (> 95%) of infection, indicating higher diagnostic rule-in utility than was apparent using conventional analyses of diagnostic accuracy. 

Conclusion: SeptiFast real-time PCR on blood samples may have rapid rule-in utility for the diagnosis of health-care-associated bloodstream infection but the lack of sensitivity is a significant limiting factor. Innovations aimed at improved diagnostic sensitivity of real-time PCR in this setting are urgently required. Future work recommendations include technology developments to improve the efficiency of pathogen DNA extraction and the capacity to detect a much broader range of pathogens and drug resistance genes and the application of new statistical approaches able to more reliably assess test performance in situation where the reference standard (e.g. blood culture in the setting of high antimicrobial use) is prone to error.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This research book covers the major aspects relating to the use of novel delivery systems in enhancing both transdermal and intradermal drug delivery. It provides a review of transdermal and intradermal drug delivery, including the history of the field and the various methods employed to produce delivery systems from different materials such as device design, construction and evaluation, so as to provide a sound background to the use of novel systems in enhanced delivery applications.

Furthermore, it presents in-depth analyses of recent developments in this exponentially growing field, with a focus on microneedle arrays, needle-free injections, nanoparticulate systems and peptide-carrier-type systems. It also covers conventional physical enhancement strategies, such as tape-stripping, sonophoresis, iontophoresis, electroporation and thermal/suction/laser ablation Discussions about the penetration of the stratum corneum by the various novel strategies highlight the importance of the application method. Comprehensive and critical reviews of transdermal and intradermal delivery research using such systems focus on the outcomes of in vivoanimal and human studies. The book includes laboratory, clinical and commercial case studies featuring safety and patient acceptability studies carried out to date, and depicts a growing area for use of these novel systems is in intradermal vaccine delivery. The final chapters review recent patents in this field and describe the work ongoing in industry.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Transdermal drug delivery offers a number of advantages for the patient, due not only its non-invasive and convenient nature, but also factors such as avoidance of first pass metabolism and prevention of gastrointestinal degradation. It has been demonstrated that microneedle arrays can increase the number of compounds amenable to transdermal delivery by penetrating the skin's protective barrier, the stratum corneum, and creating a pathway for drug permeation to the dermal tissue below. Microneedles have been extensively investigated in recent decades for drug and vaccine delivery as well as minimally invasive patient monitoring/diagnosis. This review focuses on a range of critically important aspects of microneedle technology, namely their material composition, manufacturing techniques, methods of evaluation and commercial translation to the clinic for patient benefit and economic return. Microneedle research and development is finally now at the stage where commercialisation is a realistic possibility. However, progress is still required in the areas of scaled-up manufacture and regulatory approval.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Objective: Adverse effects (AEs) of antipsychotic medication have important implications for patients and prescribers in terms of wellbeing, treatment adherence and quality of life. This review summarises strategies for collecting and reporting AE data across a representative literature sample to ascertain their rigour and comprehensiveness. Methods: A PsycINFO search, following PRISMA Statement guidelines, was conducted in English-language journals (1980–July 2014) using the following search string: (antipsychotic* OR neuroleptic*) AND (subjective effect OR subjective experience OR subjective response OR subjective mental alterations OR subjective tolerability OR subjective wellbeing OR patient perspective OR self-rated effects OR adverse effects OR side-effects). Of 7,825 articles, 384 were retained that reported quantified results for AEs of typical or atypical antipsychotics amongst transdiagnostic adult, adolescent, and child populations. Information extracted included: types of AEs reported; how AEs were assessed; assessment duration; assessment of the global impact of antipsychotic consumption on wellbeing; and conflict of interest due to industry sponsorship. Results: Neurological, metabolic, and sedation-related cognitive effects were reported most systematically relative to affective, anticholinergic, autonomic, cutaneous, hormonal, miscellaneous, and non-sedative cognitive effects. The impact of AEs on patient wellbeing was poorly assessed. Cross-sectional and prospective research designs yielded more comprehensive data about AE severity and prevalence than clinical or observational retrospective studies. 3 Conclusions: AE detection and classification can be improved through the use of standardised assessment instruments and consideration of subjective patient impact. Observational research can supplement information from clinical trials to improve the ecological validity of AE data.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Tese de doutoramento, Farmácia (Tecnologia Farmacêutica), Universidade de Lisboa, Faculdade de Farmácia, 2015

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Thesis (Ph.D.)--University of Washington, 2016-02

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A new strategy for creating functional trilayer nanofibers through triaxial electrospinning is demonstrated. Ethyl cellulose (EC) was used as the filament-forming matrix in the outer, middle, and inner working solutions and was combined with varied contents of the model active ingredient ketoprofen (KET) in the three fluids. Triaxial electrospinning was successfully carried out to generate medicated nanofibers. The resultant nanofibers had diameters of 0.74 ± 0.06 μm, linear morphologies, smooth surfaces, and clear trilayer nanostructures. The KET concentration in each layer gradually increased from the outer to the inner layer. In vitro dissolution tests demonstrated that the nanofibers could provide linear release of KET over 20 h. The protocol reported in this study thus provides a facile approach to creating functional nanofibers with sophisticated structural features.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

As part of the evaluation of the Confederation's measures to reduce drug related problems, a review of available data on drug use and drug related problems in Switzerland has been conducted. Source of data included: population surveys (adults and teenagers), surveys among drug users, health statistics (drug related and AIDS related deaths, HIV case reporting, drug treatments) police statistics (denunciations for consumption). The aims of reducing the number of dependent hard drug users have been achieved where heroin is concerned. In particular, there seems to have been a decrease in the number of people becoming addicted to this substance. For all other illegal substances, especially cannabis, the trend is towards an increased use, as in many European countries. As regards dependent drug users, especially injecting drug users, progress has been made in the area of harm reduction and treatment coverage. This epidemiological assessment can be used in the discussions currently engaged about the revision of the Law governing narcotics and will be a baseline for future follow up of the situation.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

As reactive extraction grown more and more popular in a variety of technological applications, optimizing its performance becomes more and more important. The process of complex formation is affected by a great number of both physical and chemical properties of all the components involved, and sometimes their interference with one another makes improving the effectiveness of such processes very difficult. In this Master’s Theses, the processes of complex formation between the aqueous phase - represented by copper sulfate water solution, and organic phase – represented by Acorga M5640 solvent extractor, were studied in order to establish the effect these components have on reactive extraction performance and to determine which step is bottlenecking the process the most.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Although alcohol problems and alcohol consumption are related, consumption does not fully account for differences in vulnerability to alcohol problems. Therefore, other factors should account for these differences. Based on previous research, it was hypothesized that risky drinking behaviours, illicit and prescription drug use, affect and sex differences would account for differences in vulnerability to alcohol problems while statistically controlling for overall alcohol consumption. Four models were developed that were intended to test the predictive ability of these factors, three of which tested the predictor sets separately and a fourth which tested them in a combined model. In addition, two distinct criterion variables were regressed on the predictors. One was a measure of the frequency that participants experienced negative consequences that they attributed to their drinking and the other was a measure of the extent to which participants perceived themselves to be problem drinkers. Each of the models was tested on four samples from different populations, including fIrst year university students, university students in their graduating year, a clinical sample of people in treatment for addiction, and a community sample of young adults randomly selected from the general population. Overall, support was found for each of the models and each of the predictors in accounting for differences in vulnerability to alcohol problems. In particular, the frequency with which people become intoxicated, frequency of illicit drug use and high levels of negative affect were strong and consistent predictors of vulnerability to alcohol problems across samples and criterion variables. With the exception of the clinical sample, the combined models predicted vulnerability to negative consequences better than vulnerability to problem drinker status. Among the clinical and community samples the combined model predicted problem drinker status better than in the student samples.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Mémoire numérisé par la Division de la gestion de documents et des archives de l'Université de Montréal