874 resultados para ARTIFICIAL VENTILATION


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Realiza una revisión del proceso de la crianza de larvas de la anchoveta; el cuál es un importante pez de carnada empleada en la captura de los atunes en el Océano Pacífico Oriental Tropical. Se describe las técnicas de separación de huevos en los criaderos de laboratorio.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: There are only a few established artificial urinary sphincters for treatment of incontinence. We have developed a new device composed by three parts: the actuator, three contractile rings and a control unit. The actuator is made of Nitinol fibers, driven by microprocessor. The fibers are linked to the rings placed around the urethra. They function with alternance in their open and closed position. This concept is called piano concept. With this set-up, the constant compression on the urethra is strongly reduced. Methods: Six male sheep have been used for this study. The sphincter was open each hour for a period of 10 min., to guaranty urination. The bladder was filled with water while one cuff was closed and bladder pressure was monitored. The animals were sacrificed. Two biopsies around two cuffs of each explant and all three cuffs from each explant including urethra were analyzed. Urethra not surrounded by a cuff was taken as control. Results: The pressure exerted by the sphincter around the urethra provided continence. Simulated incontinence occurred at a pressure of 1bar measured on the bladder wall using a pressure probe. The closing force of the cuff was approx. 0·7N. No difference in tissue structure and organization of the urethra with and without artificial sphincter was observed. Conclusions: This device has several advantages compared to other urinary sphincters. It is easy to implant, has no hydraulic nature and reduces ischemic injury of the urethra by the alternance of urethral part compressed. Proof of concept in vivo has been demonstrated. Other studies are planned to determine long-term outcome.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To assess the suitability of a hot-wire anemometer infant monitoring system (Florian, Acutronic Medical Systems AG, Hirzel, Switzerland) for measuring flow and tidal volume (Vt) proximal to the endotracheal tube during high-frequency oscillatory ventilation. DESIGN: In vitro model study. SETTING: Respiratory research laboratory. SUBJECT: In vitro lung model simulating moderate to severe respiratory distress. INTERVENTION: The lung model was ventilated with a SensorMedics 3100A ventilator. Vt was recorded from the monitor display (Vt-disp) and compared with the gold standard (Vt-adiab), which was calculated using the adiabatic gas equation from pressure changes inside the model. MEASUREMENTS AND MAIN RESULTS: A range of Vt (1-10 mL), frequencies (5-15 Hz), pressure amplitudes (10-90 cm H2O), inspiratory times (30% to 50%), and Fio2 (0.21-1.0) was used. Accuracy was determined by using modified Bland-Altman plots (95% limits of agreement). An exponential decrease in Vt was observed with increasing oscillatory frequency. Mean DeltaVt-disp was 0.6 mL (limits of agreement, -1.0 to 2.1) with a linear frequency dependence. Mean DeltaVt-disp was -0.2 mL (limits of agreement, -0.5 to 0.1) with increasing pressure amplitude and -0.2 mL (limits of agreement, -0.3 to -0.1) with increasing inspiratory time. Humidity and heating did not affect error, whereas increasing Fio2 from 0.21 to 1.0 increased mean error by 6.3% (+/-2.5%). CONCLUSIONS: The Florian infant hot-wire flowmeter and monitoring system provides reliable measurements of Vt at the airway opening during high-frequency oscillatory ventilation when employed at frequencies of 8-13 Hz. The bedside application could improve monitoring of patients receiving high-frequency oscillatory ventilation, favor a better understanding of the physiologic consequences of different high-frequency oscillatory ventilation strategies, and therefore optimize treatment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Postoperative delirium after cardiac surgery is associated with increased morbidity and mortality as well as prolonged stay in both the intensive care unit and the hospital. The authors sought to identify modifiable risk factors associated with the development of postoperative delirium in elderly patients after elective cardiac surgery in order to be able to design follow-up studies aimed at the prevention of delirium by optimizing perioperative management. A post hoc analysis of data from patients enrolled in a randomized controlled trial was performed. A single university hospital. One hundred thirteen patients aged 65 or older undergoing elective cardiac surgery with cardiopulmonary bypass. None. MEASUREMENTS AND MAINS RESULTS: Screening for delirium was performed using the Confusion Assessment Method (CAM) on the first 6 postoperative days. A multivariable logistic regression model was developed to identify significant risk factors and to control for confounders. Delirium developed in 35 of 113 patients (30%). The multivariable model showed the maximum value of C-reactive protein measured postoperatively, the dose of fentanyl per kilogram of body weight administered intraoperatively, and the duration of mechanical ventilation to be independently associated with delirium. In this post hoc analysis, larger doses of fentanyl administered intraoperatively and longer duration of mechanical ventilation were associated with postoperative delirium in the elderly after cardiac surgery. Prospective randomized trials should be performed to test the hypotheses that a reduced dose of fentanyl administered intraoperatively, the use of a different opioid, or weaning protocols aimed at early extubation prevent delirium in these patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Open lung biopsy (OLB) is helpful in the management of patients with acute respiratory distress syndrome (ARDS) of unknown etiology. We determine the impact of surgical lung biopsies performed at the bedside on the management of patients with ARDS. METHODS: We reviewed all consecutive cases of patients with ARDS who underwent a surgical OLB at the bedside in a medical intensive care unit between 1993 and 2005. RESULTS: Biopsies were performed in 19 patients mechanically ventilated for ARDS of unknown etiology despite extensive diagnostic process and empirical therapeutic trials. Among them, 17 (89%) were immunocompromised and 10 patients experienced hematological malignancies. Surgical biopsies were obtained after a median (25%-75%) mechanical ventilation of 5 (2-11) days; mean (+/-SD) Pao(2)/Fio(2) ratio was 119.3 (+/-34.2) mm Hg. Histologic diagnoses were obtained in all cases and were specific in 13 patients (68%), including 9 (47%) not previously suspected. Immediate complications (26%) were local (pneumothorax, minimal bleeding) without general or respiratory consequences. The biopsy resulted in major changes in management in 17 patients (89%). It contributed to a decision to limit care in 12 of 17 patients who died. CONCLUSION: Our data confirm that surgical OLB may have an important impact on the management of patients with ARDS of unknown etiology after extensive diagnostic process. The procedure can be performed at the bedside, is safe, and has a high diagnostic yield leading to major changes in management, including withdrawal of vital support, in the majority of patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction and objectives: The AMS 800TM is considered the gold standard for sphincter replacement. However, the one-ring design can erode the urethra and lead to severe complications. A mechanism that could alternatively compress successive segments of the urethra would limit such deleterious outcome. We report 12 weeks animal urethral tissue analysis following implantation of a new modular artificial sphincter. METHODS: The device is composed by three parts: the contractile unit, two rings and an integrated microprocessor. The contractile unit is made of Nitinol fibers. The rings are placed around the urethra to control the flow of urine by squeezing the urethra. They work in a sequential alternative mode and are controlled by a microprocessor connected to an external computer. The computer can reveal specific failure of device components. The device was impkanted in eight male sheep. The rings were positioned around the urethra and the control unit was placed 5cm away. The device was working twenty hours per day; it was open 10min. per hour to allow urination. The animals were sacrificed after 12 weeks. The urethra and the tissues surrounding the control unit were macroscopically and microscopically examined. Two transversal sections crossing the sphincter and two transversal sections crossing the urethra alone were obtained and stained with modified Paragon after resin embedding. Urethra was also embedded in paraffin. The first section was stained with safranin-hematoxylin-eosin, the second section was stained with Masson's Trichrome and the remaining eight sections were available for immunolabelling of the macrophages.Results: The chronic study went uneventful. No clinical infection or pain was observed. The computer registered no specific failure in ring function, Nitinol wires and tube connectors. At explantation, except for a slight grade of lymphocytes in two out of eight specimens, no urethral stricture or atrophy could be observed. Immunohistochemistry confirmed the absence of macrophages. Tissue structure and organization of the urethra with and without artificial sphincter were similar. No migration of the device was observed.Conclusions: The study clearly showed no tissue damage or inflammation of the urethra. Electronic design, preservation of urethral vascularisation and adjustability after implantation are the key ideas to improve the actual AUS. Further studies will be carried out to evaluate this potential.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O conhecimento do valor da erosividade da chuva (R) de determinada localidade é fundamental para a estimativa das perdas de solo feitas a partir da Equação Universal de Perdas de Solo, sendo, portanto, de grande importância no planejamento conservacionista. A fim de obter estimativas do valor de R para localidades onde este é desconhecido, desenvolveu-se uma rede neural artificial (RNA) e analisou-se a acurácia desta com o método de interpolação "Inverso de uma Potência da Distância" (ID). Comparando a RNA desenvolvida com o método de interpolação ID, verificou-se que a primeira apresentou menor erro relativo médio na estimativa de R e melhor índice de confiança, classificado como "Ótimo", podendo, portanto, ser utilizada no planejamento de uso, manejo e conservação do solo no Estado de São Paulo.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to locate the breakpoints of cerebral and muscle oxygenation and muscle electrical activity during a ramp exercise in reference to the first and second ventilatory thresholds. Twenty-five cyclists completed a maximal ramp test on an electromagnetically braked cycle-ergometer with a rate of increment of 25 W/min. Expired gazes (breath-by-breath), prefrontal cortex and vastus lateralis (VL) oxygenation [Near-infrared spectroscopy (NIRS)] together with electromyographic (EMG) Root Mean Square (RMS) activity for the VL, rectus femoris (RF), and biceps femoris (BF) muscles were continuously assessed. There was a non-linear increase in both cerebral deoxyhemoglobin (at 56 ± 13% of the exercise) and oxyhemoglobin (56 ± 8% of exercise) concomitantly to the first ventilatory threshold (57 ± 6% of exercise, p > 0.86, Cohen's d < 0.1). Cerebral deoxyhemoglobin further increased (87 ± 10% of exercise) while oxyhemoglobin reached a plateau/decreased (86 ± 8% of exercise) after the second ventilatory threshold (81 ± 6% of exercise, p < 0.05, d > 0.8). We identified one threshold only for muscle parameters with a non-linear decrease in muscle oxyhemoglobin (78 ± 9% of exercise), attenuation in muscle deoxyhemoglobin (80 ± 8% of exercise), and increase in EMG activity of VL (89 ± 5% of exercise), RF (82 ± 14% of exercise), and BF (85 ± 9% of exercise). The thresholds in BF and VL EMG activity occurred after the second ventilatory threshold (p < 0.05, d > 0.6). Our results suggest that the metabolic and ventilatory events characterizing this latter cardiopulmonary threshold may affect both cerebral and muscle oxygenation levels, and in turn, muscle recruitment responses.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The forced oscillation technique (FOT) is a method for non-invasively assessing respiratory mechanics that is applicable both in paralysed and non-paralysed patients. As the FOT requires a minimal modification of the conventional ventilation setting and does not interfere with the ventilation protocol, the technique is potentially useful to monitor patient mechanics during invasive and noninvasive ventilation. FOT allows the assessment of the respiratory system linearity by measuring resistance and reactance at different lung volumes or end-expiratory pressures. Moreover, FOT allows the physician to track the changes in patient mechanics along the ventilation cycle. Applying FOT at different frequencies may allow the physician to interpret patient mechanics in terms of models with pathophysiological interest. The current methodological and technical experience make possible the implementation of portable and compact computerised FOT systems specifically addressed to its application in the mechanical ventilation setting.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Quality control procedures vary considerably among the providers of equipment for home mechanical ventilation (HMV). Methods: A multicentre quality control survey of HMV was performed at the home of 300 patients included in the HMV programmes of four hospitals in Barcelona. It consisted of three steps: (1) the prescribed ventilation settings, the actual settings in the ventilator control panel, and the actual performance of the ventilator measured at home were compared; (2) the different ventilator alarms were tested; and (3) the effect of differences between the prescribed settings and the actual performance of the ventilator on non-programmed readmissions of the patient was determined. Results: Considerable differences were found between actual, set, and prescribed values of ventilator variables; these differences were similar in volume and pressure preset ventilators. The percentage of patients with a discrepancy between the prescribed and actual measured main ventilator variable (minute ventilation or inspiratory pressure) of more than 20% and 30% was 13% and 4%, respectively. The number of ventilators with built in alarms for power off, disconnection, or obstruction was 225, 280 and 157, respectively. These alarms did not work in two (0.9%), 52 (18.6%) and eight (5.1%) ventilators, respectively. The number of non-programmed hospital readmissions in the year before the study did not correlate with the index of ventilator error. Conclusions: This study illustrates the current limitations of the quality control of HMV and suggests that improvements should be made to ensure adequate ventilator settings and correct ventilator performance and ventilator alarm operation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the present work, an analysis of the dark and optical capacitance transients obtained from Schottky Au:GaAs barriers implanted with boron has been carried out by means of the isothermal transient spectroscopy (ITS) and differential and optical ITS techniques. Unlike deep level transient spectroscopy, the use of these techniques allows one to easily distinguish contributions to the transients different from those of the usual deep trap emission kinetics. The results obtained show the artificial creation of the EL2, EL6, and EL5 defects by the boron implantation process. Moreover, the interaction mechanism between the EL2 and other defects, which gives rise to the U band, has been analyzed. The existence of a reorganization process of the defects involved has been observed, which prevents the interaction as the temperature increases. The activation energy of this process has been found to be dependent on the temperature of the annealing treatment after implantation, with values of 0.51 and 0.26 eV for the as‐implanted and 400 °C annealed samples, respectively. The analysis of the optical data has corroborated the existence of such interactions involving all the observed defects that affect their optical parameters

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A rugosidade da superfície do solo é influenciada pelo manejo, formada em especial pelo tipo de preparo e reduzida pela ação da chuva, principalmente. O objetivo deste estudo foi avaliar a influência de diferentes sistemas de manejo do solo e da aplicação de chuva artificial na rugosidade da superfície do solo. Os tratamentos estudados resultaram da combinação de três sistemas de manejo do solo, semeadura direta (SD), preparo convencional (PC) e cultivo mínimo (CM), com três doses de resíduo vegetal seco de soja (Glycine max L. Merrill): 0, 2 e 4 Mg ha-1. Nas unidades experimentais foram aplicadas sete chuvas, com intensidade de precipitação pluvial de 60 mm h-1 e duração de 60 min cada, totalizando 420 mm de lâmina de chuva. A rugosidade foi avaliada imediatamente antes e após o preparo do solo e imediatamente após a aplicação de cada uma das sete chuvas artificiais. Obtiveram-se valores do índice de rugosidade ao acaso entre 1,88 e 5,41 mm na semeadura direta; entre 3,88 e 8,30 mm no preparo convencional; e entre 8,99 e 17,45 mm no cultivo mínimo. Concluiu-se que: as operações de preparo do solo aumentaram a rugosidade da sua superfície, em geral; o cultivo mínimo foi o sistema de preparo do solo que proporcionou os maiores valores de rugosidade ao acaso; e nos tratamentos semeadura direta com cobertura do solo a ação da chuva não promoveu decaimento do microrrelevo do solo.