967 resultados para 18-CROWN-6


Relevância:

80.00% 80.00%

Publicador:

Resumo:

The paper presents some preliminary results of an ongoing research intended to qualify a highly resistant duplex stainless steel wire as prestressing steel and, gets on insight on (he wires' fracture micromechanism and residual stresses field. SEM fractographic analysis of the stainless steel wires indicates an anisotropic fracture behavior in tension, in presence of surface flaws, attributed to the residual stresses generated through the fabrication process. The residual stresses magnitude influences the damage tolerance, its knowledge being a key issue in designating/qualifying the wires as prestressing steels.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

O câncer do colo do útero constitui a terceira neoplasia maligna mais comum na população feminina, com aproximadamente 520 mil novos casos e 260 mil óbitos por ano e origina-se a partir da infecção genital persistente pelo Papiloma Vírus Humano (HPV) oncogênico. Os principais HPVs considerados de alto risco oncogênico são os tipos HPV-16 e 18, responsáveis por cerca de 70% de todos os casos de cânceres cervicais (CC) no mundo. Pacientes com CC apresentam taxa de recidiva variando de 8% a 49%. Dentro de dois anos de seguimento, 62% a 89% das recidivas são detectadas. Atualmente, os testes usados para detecção de recidiva são a citopatologia da cúpula vaginal e exames de imagem, porém ainda não estão disponíveis testes específicos. O DNA livre-circulante (cf-DNA) representa um biomarcador não-invasivo facilmente obtido no plasma e soro. Vários estudos mostram ser possível detectar e quantificar ácidos nucléicos no plasma de pacientes com câncer e que as alterações no cfDNA potencialmente refletem mudanças que ocorrem durante a tumorigênese. Essa ferramenta diagnóstica não-invasiva pode ser útil no rastreio, prognóstico e monitoramento da resposta ao tratamento do câncer. Portanto, o desenvolvimento e a padronização de testes laboratoriais não invasivos capazes de identificar marcadores tumorais e diagnosticar precocemente a recidiva da doença aumentam a chance de cura através da utilização dos tratamentos preconizados. Sendo assim, este estudo tem o objetivo de detectar o DNA de HPV no plasma de pacientes com CC para avaliar sua potencial utilidade como marcador precoce de recidiva. Um fragmento de tumor e sangue de pacientes com CC, atendidas no ICESP e HC de Barretos, foram coletados antes do tratamento. Entraram no estudo 137 pacientes nas quais o tumor foi positivo para HPV-16 ou 18, sendo 120 amostras positivas para HPV-16 (87,6%), 12 positivas para HPV-18 (8,8%) e cinco positivas para HPV-16 e 18 (3,6%). A média de idade das pacientes deste estudo foi de 52,5 anos. Plasma de 131 pacientes com CC da data do diagnóstico e de 110 pacientes do seguimento foram submetidas ao PCR em Tempo Real HPV tipo específico. A presença do DNA de HPV no plasma pré-tratamento foi observada em 58,8% (77/131) com carga viral variando de 204 cópias/mL a 2.500.000 cópias/mL. A positividade de DNA no plasma pré-tratamento aumentou com o estadio clínico do tumor: I - 45,2%, II - 52,5%, III - 80,0% e IV - 76,9%, (p=0,0189). A presença do DNA de HPV no plasma pós-tratamento foi observada em 27,3% (30/110). A média de tempo das recidivas foi de 3,1 anos (2,7 - 3,5 anos). O DNA de HPV foi positivo até 460 dias antes do diagnóstico clínico da recidiva. As pacientes com DNA de HPV no plasma apresentaram pior prognóstico, tanto sobrevida como o tempo livre de doença, em relação às que foram negativas. Nas pacientes com CC a presença de HPV no plasma de seguimento pode ser um marcador precoce útil para o monitoramento da resposta terapêutica e detecção de pacientes com risco aumentado de recidiva e progressão da doença.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

[tercüme eden] Mehmet bin Mustafa el-Vanî.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Purpose: There are few studies demonstrating the link between neural oscillations in magnetoencephalography (MEG) at rest and cognitive performance. Working memory is one of the most studied cognitive processes and is the ability to manipulate information on items kept in short-term memory. Heister & al. (2013) showed correlation patterns between brain oscillations at rest in MEG and performance in a working memory task (n-back). These authors showed that delta/theta activity in fronto-parietal areas is related to working memory performance. In this study, we use resting state MEG oscillations to validate these correlations with both of verbal (VWM) and spatial (SWM) working memory, and test their specificity in comparison with other cognitive abilities. Methods: We recorded resting state MEG and used clinical neuropsychological tests to assess working memory performance in 18 volunteers (6 males and 12 females). The other neuropsychological tests of the WAIS-IV were used as control tests to assess the specificity of the correlation patterns with working memory. We calculated means of Power Spectrum Density for different frequency bands (delta, 1-4Hz; theta, 4-8Hz; alpha, 8-13Hz; beta, 13-30Hz; gamma1, 30-59Hz; gamma2, 61-90Hz; gamma3, 90-120Hz; large gamma, 30-120Hz) and correlated MEG power normalised for the maximum in each frequency band at the sensor level with working memory performance. We then grouped the sensors showing a significant correlation by using a cluster algorithm. Results: We found positive correlations between both types of working memory performance and clusters in the bilateral posterior and right fronto-temporal regions for the delta band (r2 =0.73), in the fronto-middle line and right temporal regions for the theta band (r2 =0.63) as well as in the parietal regions for the alpha band (r2 =0.78). Verbal working memory and spatial working memory share a common fronto-parietal cluster of sensors but also show specific clusters. These clusters are specific to working memory, as compared to those obtained for other cognitive abilities and right posterior parietal areas, specially in slow frequencies, appear to be specific to working memory process. Conclusions: Slow frequencies (1-13Hz) but more precisely in delta/theta bands (1-8Hz), recorded at rest with magnetoencephalography, predict working memory performance and support the role of a fronto-parietal network in working memory.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Methane hydrates are present in marine seep systems and occur within the gas hydrate stability zone. Very little is known about their crystallite sizes and size distributions because they are notoriously difficult to measure. Crystal size distributions are usually considered as one of the key petrophysical parameters because they influence mechanical properties and possible compositional changes, which may occur with changing environmental conditions. Variations in grain size are relevant for gas substitution in natural hydrates by replacing CH4 with CO2 for the purpose of carbon dioxide sequestration. Here we show that crystallite sizes of gas hydrates from some locations in the Indian Ocean, Gulf of Mexico and Black Sea are in the range of 200-400 µm; larger values were obtained for deeper-buried samples from ODP Leg 204. The crystallite sizes show generally a log-normal distribution and appear to vary sometimes rapidly with location.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

For piano; originally for various combinations of instruments.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Each part paged continuously.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Reprinted from the Physical review n.s. v.18, no.6. Dec.1921.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fasc. 1, suppl., 1-4, fasc. 4, pt. 11-18, fasc. 7-8 have imprint: Raleigh, North Carolina State University [etc] fasc. 6 has imprint: Washington, Agricultural Research Service, United States Dept. of Agriculture.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Vol. 6 includes some sermons written by Mariano de Velasco.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

"From the Smithsonian report for 1928." "Reprinted, with change of title...from the Journal of the Washington Academy of Sciences, vol.18, no.6, Mar. 19, 1928."

Relevância:

80.00% 80.00%

Publicador:

Resumo:

1. The ability of the CGRP antagonist BIBN4096BS to antagonize CGRP and adrenomedullin has been investigated on cell lines endogenously expressing receptors of known composition. 2. On human SK-N-MC cells (expressing human calcitonin receptor-like receptor (CRLR) and receptor activity modifying protein 1 (RAMP1)), BIBN4096BS had a pA 2 of 9.95 although the slope of the Schild plot (1.37±0.16) was significantly greater than 1. 3. On rat L6 cells (expressing rat CRLR and RAMP1), BIBN4096BS had a pA 2 of 9.25 and a Schild slope of 0.89±0.05, significantly less than 1. 4. On human Colony (Col) 29 cells, CGRP 8-37 had a significantly lower pA 2 than on SK-N-MC cells (7.34±0.19 (n=7) compared to 8.35±0.18, (n=6)). BIBN4096BS had a pA 2 of 9.98 and a Schild plot slope of 0.86±0.19 that was not significantly different from 1. At concentrations in excess of 3 nM, it was less potent on Col 29 cells than on SK-N-MC cells. 5. On Rat 2 cells, expressing rat CRLR and RAMP2, BIBN4096BS was unable to antagonize adrenomedullin at concentrations up to 10 μM. CGRP 8-37 had a pA 2 of 6.72 against adrenomedullin. 6. BIBN4096BS shows selectivity for the human CRLR/RAMP1 combination compared to the rat counterpart. It can discriminate between the CRLR/RAMP1 receptor expressed on SK-N-MC cells and the CGRP-responsive receptor expressed by the Col 29 cells used in this study. Its slow kinetics may explain its apparent 'non-competive' behaviour. At concentrations of up to 10 μM, it has no antagonist actions at the adrenomedullin, CRLR/RAMP2 receptor, unlike CGRP 8-37.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The kinetics and mechanisms of ring opening polymerization and copolymerizntion of different cyclic ethers were studied using mainly a cationic system of iinitiation. BF30Et2/ethanediol. The cyclic ethers reacted differently showing that ring strain and basicity are the main driving forces in cationic ring opening polymerizaion. In most cases it was found that the degree of polymerization is controlled kinetically via terminations with the counterion and the monomers, and that the contribution of each type of reaction to the overall termination differs markedly. The Gel permeation chromatography studies showed that the molecular weight distribution of the samples of polyoxetanes were bimodal. This was in accordance with previous work establishing that the cyclic tetramer is found in much higher proportions than any of the other cyclic oligomers. However the molecular weight distribution of the copolymers made from oxetane and THF or from oxetane and oxepane were shown to be unimodal. These observations could be explained by a change in the structure of the growing end involved in the cationic polymerization. In addition crown ethers like dibenzo-crown-6 and compounds such as veratrole are believed to stabilise the propagating end and promote the formation of living polymers from oxetane.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Ocular barriers and the poor water solubility of drug candidates present a number of problems for the development of ocular drug delivery systems. Recently, the emergence of lipid-based nanocarriers has provided a viable means of enhancing the bioavailability of ophthalmic formulations. A number of these formulations have been found to be clinically active and several others are currently undergoing clinical trials. In this review, the advantages of lipid-based nanocarriers as non-invasive topical ocular drug delivery systems are presented. Many systems, including emulsions, liposomes, cubosomes, niosomes and other lipid-based nanocarriers, are reviewed.