948 resultados para 1 kyr running mean
Resumo:
This study aimed to quantitatively describe and compare whole-body fat oxidation kinetics in cycling and running using a sinusoidal mathematical model (SIN). Thirteen moderately trained individuals (7 men and 6 women) performed two graded exercise tests, with 3-min stages and 1 km h(-1) (or 20 W) increment, on a treadmill and on a cycle ergometer. Fat oxidation rates were determined using indirect calorimetry and plotted as a function of exercise intensity. The SIN model, which includes three independent variables (dilatation, symmetry and translation) that account for main quantitative characteristics of kinetics, provided a mathematical description of fat oxidation kinetics and allowed for determination of the intensity (Fat(max)) that elicits maximal fat oxidation (MFO). While the mean fat oxidation kinetics in cycling formed a symmetric parabolic curve, the mean kinetics during running was characterized by a greater dilatation (i.e., widening of the curve, P < 0.001) and a rightward asymmetry (i.e., shift of the peak of the curve to higher intensities, P = 0.01). Fat(max) was significantly higher in running compared with cycling (P < 0.001), whereas MFO was not significantly different between modes of exercise (P = 0.36). This study showed that the whole-body fat oxidation kinetics during running was characterized by a greater dilatation and a rightward asymmetry compared with cycling. The greater dilatation may be mainly related to the larger muscle mass involved in running while the rightward asymmetry may be induced by the specific type of muscle contraction.
Resumo:
BACKGROUND: An animal study was carried out to compare long-term patency rates of coronary anastomoses performed with the GraftConnector versus running suture technique. METHODS: 10 sheep, 45 to 55 kg, underwent off-pump coronary artery bypass grafting (right internal mammary artery to left anterior descending artery). In 5 animals, the anastomosis was performed with a GraftConnector and in 5 animals with 7-0 running suture. Intraoperative fluoroscopy and a fluoroscopic control at 6 months were performed. After 6 months, the animals were sacrificed and the anastomoses were examined histologically. RESULTS: All animals survived at 6 months with 100% anastomosis patency rates in both groups. In the GraftConnector group, the anastomosis diameter at 6 months fluoroscopy was 118% of native left anterior descending artery versus 97% of the control group. Luminal anastomotic width at histology was 1.7 +/- 0.2 mm in the device group versus 1.6 +/- 0.1 mm in the control group. Mean intimal hyperplasia thickness was 0.21 +/- 0.1 mm in the device group versus 0.01 mm in the control group. CONCLUSIONS: The GraftConnector provides a consistent and reproducible coronary artery anastomosis and reduces technical demand and manual dexterity in coronary operations. Long-term results demonstrate that off-pump coronary artery bypass grafting performed with the GraftConnector had the same patency rate and luminal width as those performed with running suture.
Resumo:
To determine whether a 4-a-side handball (HB) game is an appropriate aerobic stimulus to reach and potentially enhance maximal oxygen uptake (V O(2)max), and whether heart rate (HR) is a valid index of V O(2) during a handball game. Nine skilled players (21.0+/-2.9 yr) underwent a graded maximal aerobic test (GT) where V O(2)max and HR-V O(2) relationship were determined. V O(2), HR and blood lactate ([La](b)) were recorded during a 2 x 225 s (interspersed with 30s rest) 4-a-side handball game and were compared to those measured during an 480-s running intermittent exercise (IE). Mean V O(2) tended to be higher in handball compared to IE (93.9+/-8.5 vs. 87.6+/-7.4% O(2)max, p=0.06), whereas HR was similar (92.3+/-4.9 vs. 93.9+/-3.9% of the peak of HR, p=0.10). [La](b) was lower for handball than for IE (8.9+/-3.5 vs. 11.6+/-2.1 mmol l(-1), p=0.04). Time spent over 90% of V O(2)max was higher for handball than for IE (336.1+/-139.6s vs. 216.1+/-124.7s; p=0.03). The HR-V O(2) relationship during GT was high (r(2)=0.96, p<0.001) but estimated V O(2) from HR was lower to that measured (p=0.03) in handball, whereas there was no difference in IE. 4-a-side handball game can be used as a specific alternative to IE for enhancing aerobic fitness in handball players. Nevertheless, the accuracy of HR measures for estimating V O(2) during handball is poor.
Resumo:
We measured body composition and energy expenditure during walking and running on a treadmill in 40 prepubertal children: 23 obese children (9.3 +/- 1.1 years of age; 46 +/- 10 kg (mean +/- SD)) and 17 nonobese matched control children (9.2 +/- 0.6 years of age; 30 +/- 5 kg). Energy expenditure was assessed by indirect calorimetry with a standard open-circuit method. At the same speed of exercise, the energy expenditure was significantly (p < 0.01) greater in obese than in control children, in both boys and girls. Expressed per kilogram of body weight or per kilogram of fat-free mass, the energy expenditure was comparable in the two groups. Obese children had a significantly (p < 0.01) larger pulmonary ventilatory response to exercise than did control children. Heart rate was comparable in boys and girls combined but significantly higher (p < 0.05) in obese subjects, if boys and girls were analyzed separately. These data indicate that walking and running are energetically more expensive for obese children than for children of normal body weight. The knowledge of these energy costs could be useful in devising a physical activity program to be used in the treatment of obese children.
Resumo:
Several studies (on an inclined platform or with special shoes) have reported improved jump performance when the ankle was in a dorsiflexion (DF) position. The present study aims to test whether shoes inducing moderate DF modify vertical jump performance and energy cost. Twenty-one young, healthy female subjects (30 +/- 6 yr, 58 +/- 6 kg, O2max 45 +/- 3 mLxkg-1xmin-1, mean +/- SD) participated in the study. Jump performance was tested with subjects either wearing 4 degrees DF or standard (S) shoes. The jump tests (performed on a force platform) consisted of squat jump (SJ), countermovement jump (CMJ), and continuous jumps (CJ) during 15 seconds. Measured parameters were jump height, speed at take off, and maximal and average power. Oxygen uptake was measured on a treadmill while subjects ran at 95% of the anaerobic threshold during a 7-minute steady-state period. As compared with S shoes, DF shoes significantly improved the height of SJ (31 +/- 4 cm vs. 34 +/- 4 cm, p = 0.0001), CMJ (32 +/- 4 cm vs. 34 +/- 4 cm, p = 0.0004), and CJ (17.5 +/- 4.2 cm vs. 22.0 +/- 6.0 cm, p = 0.0001). Speed at take off was also significantly higher. Mean power significantly increased in SJ and CJ but not in CMJ. Oxygen uptake was not different between conditions (p = 0.40). Dorsiflexion shoes induce a significant increase in jump performance. These results are in accordance with the concept that a DF of the ankle may induce an increase of the length and strength of the triceps surae (higher torque). However, wearing DF shoes did not require more energy during running. Dorsiflexion shoes could be used to increase jump performance in several sports such as volleyball in which jump height is essential.
Resumo:
CONTEXT: Fatigue-induced alterations in foot mechanics may lead to structural overload and injury. OBJECTIVES: To investigate how a high-intensity running exercise to exhaustion modifies ankle plantar-flexor and dorsiflexor strength and fatigability, as well as plantar-pressure distribution in adolescent runners. DESIGN: Controlled laboratory study. SETTING: Academy research laboratory. PATIENTS OR OTHER PARTICIPANTS: Eleven male adolescent distance runners (age = 16.9 ± 2.0 years, height = 170.6 ± 10.9 cm, mass = 54.6 ± 8.6 kg) were tested. INTERVENTION(S): All participants performed an exhausting run on a treadmill. An isokinetic plantar-flexor and dorsiflexor maximal-strength test and a fatigue test were performed before and after the exhausting run. Plantar-pressure distribution was assessed at the beginning and end of the exhausting run. MAIN OUTCOME MEASURE(S): We recorded plantar-flexor and dorsiflexor peak torques and calculated the fatigue index. Plantar-pressure measurements were recorded 1 minute after the start of the run and before exhaustion. Plantar variables (ie, mean area, contact time, mean pressure, relative load) were determined for 9 selected regions. RESULTS: Isokinetic peak torques were similar before and after the run in both muscle groups, whereas the fatigue index increased in plantar flexion (28.1%; P = .01) but not in dorsiflexion. For the whole foot, mean pressure decreased from 1 minute to the end (-3.4%; P = .003); however, mean area (9.5%; P = .005) and relative load (7.2%; P = .009) increased under the medial midfoot, and contact time increased under the central forefoot (8.3%; P = .01) and the lesser toes (8.9%; P = .008). CONCLUSIONS: Fatigue resistance in the plantar flexors declined after a high-intensity running bout performed by adolescent male distance runners. This phenomenon was associated with increased loading under the medial arch in the fatigued state but without any excessive pronation.
Resumo:
PURPOSE: To explore whether triaxial accelerometric measurements can be utilized to accurately assess speed and incline of running in free-living conditions. METHODS: Body accelerations during running were recorded at the lower back and at the heel by a portable data logger in 20 human subjects, 10 men, and 10 women. After parameterizing body accelerations, two neural networks were designed to recognize each running pattern and calculate speed and incline. Each subject ran 18 times on outdoor roads at various speeds and inclines; 12 runs were used to calibrate the neural networks whereas the 6 other runs were used to validate the model. RESULTS: A small difference between the estimated and the actual values was observed: the square root of the mean square error (RMSE) was 0.12 m x s(-1) for speed and 0.014 radiant (rad) (or 1.4% in absolute value) for incline. Multiple regression analysis allowed accurate prediction of speed (RMSE = 0.14 m x s(-1)) but not of incline (RMSE = 0.026 rad or 2.6% slope). CONCLUSION: Triaxial accelerometric measurements allows an accurate estimation of speed of running and incline of terrain (the latter with more uncertainty). This will permit the validation of the energetic results generated on the treadmill as applied to more physiological unconstrained running conditions.
Resumo:
The maximal aerobic capacity while running and cycling was measured in 22 prepubertal children (mean age +/- SD 9.5 +/- 0.8 years): 14 obese (47.3 +/- 10 kg) and 8 non-obese (31.1 +/- 6.1 kg). Oxygen consumption (VO2) and carbon dioxide production were measured by an open circuit method. Steady state VO2 was determined at different levels of exercise up to the maximal power on the cycloergometer (92 W in obese and 77 W in non-obese subjects) and up to the maximal running speed on the treadmill at a 2% slope (8.3 km/h in obese and 9.0 km/h in lean children). Expressed in absolute values, the VO2max in obese children was significantly higher than in controls (1.55 +/- 0.29 l/min versus 1.23 +/- 0.22 l/min, p < 0.05) for the treadmill test and comparable in the two groups (1.4 +/- 0.2 l/min versus 1.16 +/- 0.2 l/min, ns) for the cycloergometer test. When VO2max was expressed per kg fat free mass, the difference between the two groups disappeared for both tests. These data suggest that obese children had no limitation of maximal aerobic power. Therefore, the magnitude of the workload prescribed when a physical activity program is intended for the therapy of childhood obesity, it should be designed to increase caloric output rather than to improve cardiorespiratory fitness.
Resumo:
Research into the biomechanical manifestation of fatigue during exhaustive runs is increasingly popular but additional understanding of the adaptation of the spring-mass behaviour during the course of strenuous, self-paced exercises continues to be a challenge in order to develop optimized training and injury prevention programs. This study investigated continuous changes in running mechanics and spring-mass behaviour during a 5-km run. 12 competitive triathletes performed a 5-km running time trial (mean performance: ̴17 min 30 s) on a 200 m indoor track. Vertical and anterior-posterior ground reaction forces were measured every 200 m by a 5-m long force platform system, and used to determine spring-mass model characteristics. After a fast start, running velocity progressively decreased (- 11.6%; P<0.001) in the middle part of the race before an end spurt in the final 400-600 m. Stride length (- 7.4%; P<0.001) and frequency (- 4.1%; P=0.001) decreased over the 25 laps, while contact time (+ 8.9%; P<0.001) and total stride duration (+ 4.1%; P<0.001) progressively lengthened. Peak vertical forces (- 2.0%; P<0.01) and leg compression (- 4.3%; P<0.05), but not centre of mass vertical displacement (+ 3.2%; P>0.05), decreased with time. As a result, vertical stiffness decreased (- 6.0%; P<0.001) during the run, whereas leg stiffness changes were not significant (+ 1.3%; P>0.05). Spring-mass behaviour progressively changes during a 5-km time trial towards deteriorated vertical stiffness, which alters impact and force production characteristics.
Resumo:
We analyse the global structure of the phase space of the planar planetary 2/1 mean-motion resonance in cases where the outer planet is more massive than its inner companion. Inside the resonant domain, we show the existence of two families of periodic orbits, one associated to the librational motion of resonant angle (sigma-family) and the other related to the circulatory motion of the difference in longitudes of pericentre (Delta pi-family). The well-known apsidal corotation resonances (ACR) appear as intersections between both families. A complex web of secondary resonances is also detected for low eccentricities, whose strengths and positions are dependent on the individual masses and spatial scale of the system. The construction of dynamical maps for various values of the total angular momentum shows the evolution of the families of stable motion with the eccentricities, identifying possible configurations suitable for exoplanetary systems. For low-moderate eccentricities, several different stable modes exist outside the ACR. For larger eccentricities, however, all stable solutions are associated to oscillations around the stationary solutions. Finally, we present a possible link between these stable families and the process of resonance capture, identifying the most probable routes from the secular region to the resonant domain, and discussing how the final resonant configuration may be affected by the extension of the chaotic layer around the resonance region.
Resumo:
This paper presents the second part in our study of the global structure of the planar phase space of the planetary three-body problem, when both planets lie in the vicinity of a 2/1 mean-motion resonance. While Paper I was devoted to cases where the outer planet is the more massive body, the present work is devoted to the cases where the more massive body is the inner planet. As before, outside the well-known Apsidal Corotation Resonances (ACR), the phase space shows a complex picture marked by the presence of several distinct regimes of resonant and non-resonant motion, crossed by families of periodic orbits and separated by chaotic zones. When the chosen values of the integrals of motion lead to symmetric ACR, the global dynamics are generally similar to the structure presented in Paper I. However, for asymmetric ACR the resonant phase space is strikingly different and shows a galore of distinct dynamical states. This structure is shown with the help of dynamical maps constructed on two different representative planes, one centred on the unstable symmetric ACR and the other on the stable asymmetric equilibrium solution. Although the study described in the work may be applied to any mass ratio, we present a detailed analysis for mass values similar to the Jupiter-Saturn case. Results give a global view of the different dynamical states available to resonant planets with these characteristics. Some of these dynamical paths could have marked the evolution of the giant planets of our Solar system, assuming they suffered a temporary capture in the 2/1 resonance during the latest stages of the formation of our Solar system.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
The dynamics of a pair of satellites similar to Enceladus-Dione is investigated with a two-degrees-of-freedom model written in the domain of the planar general three-body problem. Using surfaces of section and spectral analysis methods, we study the phase space of the system in terms of several parameters, including the most recent data. A detailed study of the main possible regimes of motion is presented, and in particular we show that, besides the two separated resonances, the phase space is replete of secondary resonances.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)