958 resultados para wear-resistant steel


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thrust ball bearings lubricated with several different types of grease, including three biodegradable low-toxicity greases, were tested in a modified four-ball machine in order to evaluate the bearing friction torque. At the end of each test, grease samples were obtained and analysed through ferrography, allowing the quantification and evaluation of the bearing wear. In order to compare the grease performance in terms of friction and wear, a correlation between the grease characteristics (base oil, bleed oil, thickener structure, and rheological parameters) and the experimental results was established.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertation presented to obtain a Ph.D. degree in Biology, speciality in Microbiology, by Universidade Nova de Lisboa, Faculdade de Ciências e Tecnologia

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present study aims to characterize ultrafine particles emitted during gas metal arc welding of mild steel and stainless steel, using different shielding gas mixtures, and to evaluate the effect of metal transfer modes, controlled by both processing parameters and shielding gas composition, on the quantity and morphology of the ultrafine particles. It was found that the amount of emitted ultrafine particles (measured by particle number and alveolar deposited surface area) are clearly dependent from the main welding parameters, namely the current intensity and the heat input of the Welding process. The emission of airborne ultrafine particles increases with the current intensity as fume formation rate does. When comparing the shielding gas mixtures, higher emissions were observed for more oxidizing mixtures, that is, with higher CO2 content, which means that these mixtures originate higher concentrations of ultrafine particles (as measured by number of particles. by cubic centimeter of air) and higher values of alveolar deposited surface area of particles, thus resulting in a more hazardous condition regarding welders exposure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Low-loss power transmission gears operate at lower temperature than conventional ones because their teeth geometry is optimized to reduce friction. The main objective of this work is to compare the operating stabilization temperature and efficiency of low-loss austempered ductile iron (ADI) and carburized steel gears. Three different low-loss tooth geometries were adopted (types 311, 411 and 611, all produced using standard 20° pressure angle tools) and corresponding steel and ADI gears were tested in a FZG machine. The results obtained showed that low-loss geometries had a significant influence on power loss, gears 611 generating lower power loss than gears 311. At low speeds (500 and 1000 rpm) and high torque ADI gears generated lower power loss than steel gears. However, at high speed and high torque (high input power and high stabilization temperature) steel gears had better efficiency.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present study is focused on the characterization of ultrafine particles emitted in welding of steel using mixtures of Ar+CO2, and intends to analyze which are the main process parameters which may have influence on the emission itself. It was found that the amount of emitted ultrafine particles (measured by particle number and alveolar deposited surface area) are clearly dependent from the distance to the welding front and also from the main welding parameters, namely the current intensity and heat input in the welding process. The emission of airborne ultrafine particles seem to increase with the current intensity as fume formation rate does. When comparing the tested gas mixtures, higher emissions are observed for more oxidant mixtures, that is, mixtures with higher CO2 content, which result in higher arc stability. The later mixtures originate higher concentrations of ultrafine particles (as measured by number of particles by cm3 of air) and higher values of alveolar deposited surface area of particles, thus resulting in a more hazardous condition regarding worker's exposure. © 2014 Sociedade Portuguesa de Materiais (SPM). Published by Elsevier España, S.L. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Co-deposition of nickel and cobalt was carried out on austenitic stainless steel (AISI 304) substrates by imposing a square waveform current in the cathodic region. The innovative procedure applied in this work allows creating a stable, fully developed, and open porous three-dimensional (3D) dendritic structure, which can be used as electrode for redox supercapacitors. This study investigates in detail the influence of the applied current density on the morphology, mass, and chemical composition of the deposited Ni-Co films and the resulting 3D porous network dendritic structure. The morphology and the physicochemical composition were studied by scanning electron microscopy (SEM), energy dispersive X-ray spectroscopy (EDS) and X-ray diffraction (W). The electrochemical behavior of the materials was evaluated by cyclic voltammetry (CV). The results highlight the mechanism involved in the coelectrodeposition process and how the lower limit current density tailors the film composition and morphology, as well as its electrochemical activity.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O aço inoxidável é um material de alta durabilidade e resistência, utilizado nos mais diversos setores comerciais. O conhecimento das suas características e propriedades é essencial para uma escolha mais seletiva e vantajosa. Pretende‐se com este trabalho, estudar as propriedades mecânicas, a resistência ao desgaste e o comportamento, em ambientes mais agressivos de três tipos de aços inoxidáveis duplex, produzidos pela OUTOKUMPU e comercialmente conhecidos pelas designações LDX 2101, SAF 2507 e o SAF 2205. Para tal efeito foram realizados ensaios de Dureza Vickers, antes e após dobragem; ensaios de tracção em duas diferentes situações: seguindo a norma NP EN 10002‐ 1:2006 e após a realização de alguns ciclos de carga e descarga; ensaio de Impacto à temperatura ambiente e após arrefecimento criogénico; ensaio de resistência à corrosão. Também foi feito o estudo de resistência ao desgaste com base na técnica de micro‐abrasão por esfera rotativa e o estudo metalográfico. Foi também objetivo deste trabalho, relacionar o uso dos referidos aços duplex e as consequências que esse uso tem para o meio ambiente, bem como o seu comportamento quando exposto a condições extremas. Para tal, foram colocadas amostras dos referidos aços, em dois tipos de solos com condições de humidade e acidez diferentes analisando o seu estado após imersão em solo com condições controladas durante 272 dias.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nanocrystalline diamond (NCD) coatings offer an excellent alternative for tribological applications, preserving most of the intrinsic mechanical properties of polycrystalline CVD diamond and adding to it an extreme surface smoothness. Silicon nitride (Si3N4) ceramics are reported to guarantee high adhesion levels to CVD microcrystalline diamond coatings, but the NCD adhesion to Si3N4 is not yet well established. Micro-abrasion tests are appropriate for evaluating the abrasive wear resistance of a given surface, but they also provide information on thin film/substrate interfacial resistance, i.e., film adhesion. In this study, a comparison is made between the behaviour of NCD films deposited by hot-filament chemical vapour deposition (HFCVD) and microwave plasma assisted chemical vapour deposition (MPCVD) techniques. Silicon nitride (Si3N4) ceramic discs were selected as substrates. The NCD depositions by HFCVD and MPCVD were carried out using H2–CH4 and H2–CH4–N2 gas mixtures, respectively. An adequate set of growth parameters was chosen for each CVD technique, resulting in NCD films having a final thickness of 5 m. A micro-abrasion tribometer was used, with 3 m diamond grit as the abrasive slurry element. Experiments were carried out at a constant rotational speed (80 r.p.m.) and by varying the applied load in the range of 0.25–0.75 N. The wear rate for MPCVD NCD (3.7±0.8 × 10−5 m3N−1m−1) is compatible with those reported for microcrystalline CVD diamond. The HFCVD films displayed poorer adhesion to the Si3N4 ceramic substrates than the MPCVD ones. However, the HFCVD films show better wear resistance as a result of their higher crystallinity according to the UV Raman data, despite evidencing premature adhesion failure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ball rotating micro-abrasion tribometers are commonly used to carry out wear tests on thin hard coatings. In these tests, different kinds of abrasives were used, as alumina (Al2O3), silicon carbide (SiC) or diamond. In each kind of abrasive, several particle sizes can be used. Some studies were developed in order to evaluate the influence of the abrasive particle shape in the micro-abrasion process. Nevertheless, the particle size was not well correlated with the material removed amount and wear mechanisms. In this work, slurry of SiC abrasive in distilled water was used, with three different particles size. Initial surface topography was accessed by atomic force microscopy (AFM). Coating hardness measurements were performed with a micro-hardness tester. In order to evaluate the wear behaviour, a TiAlSiN thin hard film was used. The micro-abrasion tests were carried out with some different durations. The abrasive effect of the SiC particles was observed by scanning electron microscopy (SEM) both in the films (hard material) as in the substrate (soft material), after coating perforation. Wear grooves and removed material rate were compared and discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The injection process of glass fibres reinforced plastics promotes the moulds surface degradation by erosion. In order to improve its wear resistance, several kinds of PVD thin hard coatings were used. It is well-known that nanostructures present a better compromise between hardness and toughness. Indeed, when the coating is constituted by a large number of ultra-thin different layers, cracks and interface troubles tend to decrease. However, it is not clear that these nanostructures present a better wear behaviour in erosion processes. In order to study its wear behaviour, a sputtered PVD nanostructured TiAlCrSiN coating was used. The substrate and film surfaces topography were analyzed by profilometry and atomic force microscopy techniques. Film adhesion to the substrate was evaluated by scratch tests. The surface hardness was measured with a Vickers micro-hardness tester. The wear resistance was evaluated by micro-abrasion with a rotating ball tribometer tests. Slurry of SiC particles in distilled water was used in order to provoke the surface abrasion. Different duration tests were performed in order to analyze the wear evolution. After these tests, the wear mechanisms developed were analyzed by scanning electron microscopy. Wear craters were measured and the wear rate was calculated and discussed. With the same purpose, coated inserts were mounted in an injection mould working with a 30% glass fibres reinforced polypropylene. After 45 000 cycles no relevant wear was registered.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A radiometric assay system has been used to study oxidation patterns of (1-14C) fatty acids by drug-susceptible and drug-resistant organisms of the genus Mycobacterium. Two strains of M. tuberculosis susceptible to all drugs, H37Rv and Erdman, were used. Drug-resistant organisms included in this investigation were M. tuberculosis H37Rv resistant to 5 ug/ml isoniazid, M. bovis, M. avium, M. intracellular, M. kansasii and M. chelonei. The organisms were inoculated in sterile reaction vials containing liquid 7H9 medium, 10% ADC enrichment and 1.0 uCi of one of the (1-14C) fatty acids (butyric, hexánoic, octanoic, decanoic, lauric, myristic, palmitic, stearic, oleic, linoleic, linolenic). Vials were incubated at 37°C and the 14CO2 envolved was measured daily for 3 days with a Bactec R-301 instrument. Although each individual organism displayed a different pattern of fatty oxidation, these patterns were not distinctive enough for identification of the organism. No combination of fatty acids nor preferential oxidation of long chain or of short chain fatty acids were able to separate susceptible from resistant organisms. Further investigation with a larger number of drug susceptible mycobacteria including assimilation studies and oxidation of other substrates may be required to achieve a distinction between drug-susceptible and drug-resistant mycobacteria.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A radiometric assay system has been used to study oxidation patterns of (U-14C) L-amino acids by drug-susceptible and drug-resistant mycobacteria. Drug-susceptible M. tuberculosis (H37Rv TMC 102 and Erdman) along with the drug-resistant organism M. tuberculosis (H37 Rv TMC 303), M. bovis, M. avium, M. intracellulare, M. kansasii and M. chelonei were used. The organisms were inoculated into a sterile reaction system with liquid 7H9 medium and one of the (U-14C) L-amino acids. Each organism displayed a different pattern of amino acid oxidation, but these patterns were not distinctive enough for identification of the organism. Complex amino acids such as proline, phenylalanine and tyrosine were of no use in identification of mycobacteria, since virtually all organisms failed to oxidize them. There was no combination of substrates able to separate susceptible from resistant organisms.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Antibacterial activity of novel Active Pharmaceutical Ingredient Ionic Liquids (API-ILs) based on ampicillin anion [Amp] have been evaluated. They showed growth inhibition and bactericidal properties on some sensitive bacteria and especially some Gram-negative resistant bacteria when compared to the [Na][Amp] and the initial bromide and chloride salts. For these studies were analysed the minimum inhibitory concentration (MIC) and minimum bactericidal concentration (MBIC) against sensitive Gram-negative bacteria Escherichia coli ATCC 25922 and Klebsiella pneumonia (clinically isolated), as well as sensitive Gram positive S. Aureus ATCC 25923, Staphylococcus epidermidis and Enterococcus faecalis and completed using clinically isolated resistent strains: E. coli TEM CTX M9, E. coli CTX M2 and E. coli AmpC Mox. From the obtained MIC values of studied APIs-ILs and standard [Na][Amp] were derived RDIC values (relative decrease of inhibitory concentration). High RDIC values of [C16Pyr][Amp] especially against two resistant Gram-negative strains E. coli TEM CTX M9 (RDIC>1000) and E. coli CTX M2 (RDIC>100) point clearly to a potential promising role of APIs-ILs as antimicrobial drugs especially against resistant bacterial strains.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The optimal design of cold-formed steel columns is addressed in this paper, with two objectives: maximize the local-global buckling strength and maximize the distortional buckling strength. The design variables of the problem are the angles of orientation of cross-section wall elements the thickness and width of the steel sheet that forms the cross-section are fixed. The elastic local, distortional and global buckling loads are determined using Finite Strip Method (CUFSM) and the strength of cold-formed steel columns (with given length) is calculated using the Direct Strength Method (DSM). The bi-objective optimization problem is solved using the Direct MultiSearch (DMS) method, which does not use any derivatives of the objective functions. Trade-off Pareto optimal fronts are obtained separately for symmetric and anti-symmetric cross-section shapes. The results are analyzed and further discussed, and some interesting conclusions about the individual strengths (local-global and distortional) are found.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We studied the susceptibility to Leishmania (Viannia) panamensis in strains of mice. The C57BL/6 strain was resistant and showed self-controlled lesion at the injected foot pad. The BALB/c and DBA/2J strains were susceptible and showed a foot swelling that started day 20 post-infection and progressed to a tumour-like lesion in later period of observation. The CBA/HJ strain was found to be of intermediary resistance. In contrast to other known cutaneous leishmaniasis in mice, the lesion in L. (V.) panamensis-infected mice was restricted to the inoculation site in the skin. In addition, we studied the development of cellular response and antibodies against Leishmania antigen in BALB/c and C57BL/6 strains. The proliferative response of lymph node cells against L. (V.) panamensis antigen was biphasic in both strains. An initial response was seen on day 20, followed by a refractory period between 40 and 80 days and a second response around fourth month post-infection. The response in the latter period was higher in C57BL/6 strain than in BALB/c strain. BALB/c strain presented much higher anti-Leishmania antibody level than C57BL/6 strain. The model and the correlation of immunological variables and the course of the infection are discussed.