868 resultados para uncapacitated facility location


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have isolated and sequenced a cDNA encoding the human beta 2-adrenergic receptor. The deduced amino acid sequence (413 residues) is that of a protein containing seven clusters of hydrophobic amino acids suggestive of membrane-spanning domains. While the protein is 87% identical overall with the previously cloned hamster beta 2-adrenergic receptor, the most highly conserved regions are the putative transmembrane helices (95% identical) and cytoplasmic loops (93% identical), suggesting that these regions of the molecule harbor important functional domains. Several of the transmembrane helices also share lesser degrees of identity with comparable regions of select members of the opsin family of visual pigments. We have localized the gene for the beta 2-adrenergic receptor to q31-q32 on chromosome 5. This is the same position recently determined for the gene encoding the receptor for platelet-derived growth factor and is adjacent to that for the FMS protooncogene, which encodes the receptor for the macrophage colony-stimulating factor.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Gemstone Team Peace in Prisons

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Duke University Medical Center Library and Archives is located in the heart of the Duke Medicine campus, surrounded by Duke Hospital, ambulatory clinics, and numerous research facilities. Its location is considered prime real estate, given its adjacency to patient care, research, and educational activities. In 2005, the Duke University Library Space Planning Committee had recommended creating a learning center in the library that would support a variety of educational activities. However, the health system needed to convert the library's top floor into office space to make way for expansion of the hospital and cancer center. The library had only five months to plan the storage and consolidation of its journal and book collections, while working with the facilities design office and architect on the replacement of key user spaces on the top floor. Library staff worked together to develop plans for storing, weeding, and consolidating the collections and provided input into renovation plans for users spaces on its mezzanine level. The library lost 15,238 square feet (29%) of its net assignable square footage and a total of 16,897 (30%) gross square feet. This included 50% of the total space allotted to collections and over 15% of user spaces. The top-floor space now houses offices for Duke Medicine oncology faculty and staff. By storing a large portion of its collection off-site, the library was able to remove more stacks on the remaining stack level and convert them to user spaces, a long-term goal for the library. Additional space on the mezzanine level had to be converted to replace lost study and conference room spaces. While this project did not match the recommended space plans for the library, it underscored the need for the library to think creatively about the future of its facility and to work toward a more cohesive master plan.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Gemstone Team FLIP (File Lending in Proximity)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A nested heuristic approach that uses route length approximation is proposed to solve the location-routing problem. A new estimation formula for route length approximation is also developed. The heuristic is evaluated empirically against the sequential method and a recently developed nested method for location routing problems. This testing is carried out on a set of problems of 400 customers and around 15 to 25 depots with good results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The concept of 'nested methods' is adopted to solve the location-routeing problem. Unlike the sequential and iterative approaches, in this method we treat the routeing element as a sub-problem within the larger problem of location. Efficient techniques that take into account the above concept and which use a neighbourhood structure inspired from computational geometry are presented. A simple version of tabu search is also embedded into our methods to improve the solutions further. Computational testing is carried out on five sets of problems of 400 customers with five levels of depot fixed costs, and the results obtained are encouraging.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper the many to many location routing problem is introduced, and its relationship to various problems in distribution management is emphasised. Useful mathematical formulations which can be easily extended to cater for other related problems are produced. Techniques for tackling this complex distribution problem are also outlined.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

When designing a new passenger ship or modifying an existing design, how do we ensure that the proposed design and crew emergency procedures are safe from an evacuation point of view? In the wake of major maritime disasters such as the Herald of Free Enterprise and the Estonia and in light of the growth in the numbers of high density, high-speed ferries and large capacity cruise ships, issues concerned with the evacuation of passengers and crew at sea are receiving renewed interest. In the maritime industry, ship evacuation models offer the promise to quickly and efficiently bring evacuation considerations into the design phase, while the ship is "on the drawing board". maritimeEXODUS-winner of the BCS, CITIS and RINA awards - is such a model. Features such as the ability to realistically simulate human response to fire, the capability to model human performance in heeled orientations, a virtual reality environment that produces realistic visualisations of the modelled scenarios and with an integrated abandonment model, make maritimeEXODUS a truly unique tool for assessing the evacuation capabilities of all types of vessels under a variety of conditions. This paper describes the maritimeEXODUS model, the SHEBA facility from which data concerning passenger/crew performance in conditions of heel is derived and an example application demonstrating the models use in performing an evacuation analysis for a large passenger ship partially based on the requirements of MSC circular 1033.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents data relating to occupant pre-evacuation times from a university and a hospital outpatient facility. Although the two structures are entirely different they do employ relatively similar procedures: members of staff sweeping areas of the structure to encourage individuals to evacuate. However, the manner in which the dependent population reacts to these procedures is quite different. In the hospital case the patients only evacuated once a member of the nursing staff had instructed them to do so while in the university evacuation the students were less dependent upon the actions of the staff with over 50% of them evacuating with no prior prompting. Although this data may be useful in a variety of areas, it was collected primarily for use within evacuation models.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper we study the two-machine flow shop and open shop problems to minimize the makespan with a single interstage transporter that may carry any number of jobs between the machines at a time. For each of these problems we present a best possible approximation algorithm within a class of schedules with at most two shipments. As a by-product of this research, for the problem of minimizing the makespan on parallel identical machines we analyze the ratio of the makespan for a non-preemptive schedule over the makespan of a preemptive schedule.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An investigation into predicting failure of pneumatic conveyor pipe bends due to hard solid particle impact erosion has been carried out on an industrial scale test rig. The bend puncture point locations may vary with many factors. However, bend orientation was suspected of being a main factor due to the biased particle distribution pattern of a high concentration flow. In this paper, puncture point locations have been studied with different pipe bend orientations and geometry (a solids loading ratio of 10 being used for the high concentration flow). Test results confirmed that the puncture point location is indeed most significantly influenced by the bend orientation (especially for a high concentration flow) due to the biased particle distribution and biased particle flux distribution.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We explore the potential application of cognitive interrogator network (CIN) in remote monitoring of mobile subjects in domestic environments, where the ultra-wideband radio frequency identification (UWB-RFID) technique is considered for accurate source localization. We first present the CIN architecture in which the central base station (BS) continuously and intelligently customizes the illumination modes of the distributed transceivers in response to the systempsilas changing knowledge of the channel conditions and subject movements. Subsequently, the analytical results of the locating probability and time-of-arrival (TOA) estimation uncertainty for a large-scale CIN with randomly distributed interrogators are derived based upon the implemented cognitive intelligences. Finally, numerical examples are used to demonstrate the key effects of the proposed cognitions on the system performance