955 resultados para time measurement


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Despite the increased use of intracranial neuromonitoring during experimental subarachnoid hemorrhage (SAH), coordinates for probe placement in rabbits are lacking. This study evaluates the safety and reliability of using outer skull landmarks to identify locations for placement of cerebral blood flow (CBF) and intraparenchymal intracranial pressure (ICP) probes. Experimental SAH was performed in 17 rabbits using an extracranial-intracranial shunt model. ICP probes were placed in the frontal lobe and compared to measurements recorded from the olfactory bulb. CBF probes were placed in various locations in the frontal cortex anterior to the coronary suture. Insertion depth, relation to the ventricular system, and ideal placement location were determined by post-mortem examination. ICP recordings at the time of SAH from the frontal lobe did not differ significantly from those obtained from the right olfactory bulb. Ideal coordinates for intraparenchymal CBF probes in the left and right frontal lobe were found to be located 4.6±0.9 and 4.5±1.2 anterior to the bregma, 4.7±0.7mm and 4.7±0.5mm parasagittal, and at depths of 4±0.5mm and 3.9±0.5mm, respectively. The results demonstrate that the presented coordinates based on skull landmarks allow reliable placement of intraparenchymal ICP and CBF probes in rabbit brains without the use of a stereotactic frame.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Energy transfer between the interacting waves in a distributed Brillouin sensor can result in a distorted measurement of the local Brillouin gain spectrum, leading to systematic errors. It is demonstrated that this depletion effect can be precisely modelled. This has been validated by experimental tests in an excellent quantitative agreement. Strict guidelines can be enunciated from the model to make the impact of depletion negligible, for any type and any length of fiber. (C) 2013 Optical Society of America

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Telomere length measurement has been proposed as a promising tool to estimate the age of individuals in natural populations. We used real-time quantitative PCR (qPCR) to measure relative telomere length in four tissues (brain, kidney, liver and muscle) of European hake (Merluccius merluccius) in different groups based upon body length an otolith age estimate. We observed a high level of inter-individual differences in the measurements of relative telomere length in hakes of similar age and body length groups. The results of qPCR analysis showed a great variability in all measures and a lack of repeatability and reproducibility with significant statistical differences in the results of the different assays. The paper discusses the technical reasons for the variability in qPCR obtained in this work and by other authors.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: Computer-based feedback systems for assessing the quality of cardiopulmonary resuscitation (CPR) are widely used these days. Recordings usually involve compression and ventilation dependent variables. Thorax compression depth, sufficient decompression and correct hand position are displayed but interpreted independently of one another. We aimed to generate a parameter, which represents all the combined relevant parameters of compression to provide a rapid assessment of the quality of chest compression-the effective compression ratio (ECR). METHODS: The following parameters were used to determine the ECR: compression depth, correct hand position, correct decompression and the proportion of time used for chest compressions compared to the total time spent on CPR. Based on the ERC guidelines, we calculated that guideline compliant CPR (30:2) has a minimum ECR of 0.79. To calculate the ECR, we expanded the previously described software solution. In order to demonstrate the usefulness of the new ECR-parameter, we first performed a PubMed search for studies that included correct compression and no-flow time, after which we calculated the new parameter, the ECR. RESULTS: The PubMed search revealed 9 trials. Calculated ECR values ranged between 0.03 (for basic life support [BLS] study, two helpers, no feedback) and 0.67 (BLS with feedback from the 6th minute). CONCLUSION: ECR enables rapid, meaningful assessment of CPR and simplifies the comparability of studies as well as the individual performance of trainees. The structure of the software solution allows it to be easily adapted to any manikin, CPR feedback devices and different resuscitation guidelines (e.g. ILCOR, ERC).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Brain functions, such as learning, orchestrating locomotion, memory recall, and processing information, all require glucose as a source of energy. During these functions, the glucose concentration decreases as the glucose is being consumed by brain cells. By measuring this drop in concentration, it is possible to determine which parts of the brain are used during specific functions and consequently, how much energy the brain requires to complete the function. One way to measure in vivo brain glucose levels is with a microdialysis probe. The drawback of this analytical procedure, as with many steadystate fluid flow systems, is that the probe fluid will not reach equilibrium with the brain fluid. Therefore, brain concentration is inferred by taking samples at multiple inlet glucose concentrations and finding a point of convergence. The goal of this thesis is to create a three-dimensional, time-dependent, finite element representation of the brainprobe system in COMSOL 4.2 that describes the diffusion and convection of glucose. Once validated with experimental results, this model can then be used to test parameters that experiments cannot access. When simulations were run using published values for physical constants (i.e. diffusivities, density and viscosity), the resulting glucose model concentrations were within the error of the experimental data. This verifies that the model is an accurate representation of the physical system. In addition to accurately describing the experimental brain-probe system, the model I created is able to show the validity of zero-net-flux for a given experiment. A useful discovery is that the slope of the zero-net-flux line is dependent on perfusate flow rate and diffusion coefficients, but it is independent of brain glucose concentrations. The model was simplified with the realization that the perfusate is at thermal equilibrium with the brain throughout the active region of the probe. This allowed for the assumption that all model parameters are temperature independent. The time to steady-state for the probe is approximately one minute. However, the signal degrades in the exit tubing due to Taylor dispersion, on the order of two minutes for two meters of tubing. Given an analytical instrument requiring a five μL aliquot, the smallest brain process measurable for this system is 13 minutes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Research on the physiological adaptation process has found that stress is associated with the rate of cortisol secretion, the main hormone that reflects stress. However, considerable variation among subjects has been reported. Using a sample of older adults (N=46), we tested the hypothesis that cortisol reactivity is composed of (1) a situation-related component representing hypothalamic influence on cortisol secretion observed on three different occasions, and (2) a stable component representing a general trait responsible for cortisol responses observed from occasion to occasion. LISREL VIII was used to test this hypothesis. Results indicated that a homogeneous reliability model was not supported by the data. A congeneric measurement model represented a better fit to the data. Results suggest that subjects have consistent patterns of response during separate experimental occasions. However, results do not suggest a consistent pattern of response over time. The main implication of these results is that salivary cortisol measures are sensitive to experimental stress situations. As such, this noninvasive method may be useful in examining adaptive responses to stress.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Knowledge of the time interval from death (post-mortem interval, PMI) has an enormous legal, criminological and psychological impact. Aiming to find an objective method for the determination of PMIs in forensic medicine, 1H-MR spectroscopy (1H-MRS) was used in a sheep head model to follow changes in brain metabolite concentrations after death. Following the characterization of newly observed metabolites (Ith et al., Magn. Reson. Med. 2002; 5: 915-920), the full set of acquired spectra was analyzed statistically to provide a quantitative estimation of PMIs with their respective confidence limits. In a first step, analytical mathematical functions are proposed to describe the time courses of 10 metabolites in the decomposing brain up to 3 weeks post-mortem. Subsequently, the inverted functions are used to predict PMIs based on the measured metabolite concentrations. Individual PMIs calculated from five different metabolites are then pooled, being weighted by their inverse variances. The predicted PMIs from all individual examinations in the sheep model are compared with known true times. In addition, four human cases with forensically estimated PMIs are compared with predictions based on single in situ MRS measurements. Interpretation of the individual sheep examinations gave a good correlation up to 250 h post-mortem, demonstrating that the predicted PMIs are consistent with the data used to generate the model. Comparison of the estimated PMIs with the forensically determined PMIs in the four human cases shows an adequate correlation. Current PMI estimations based on forensic methods typically suffer from uncertainties in the order of days to weeks without mathematically defined confidence information. In turn, a single 1H-MRS measurement of brain tissue in situ results in PMIs with defined and favorable confidence intervals in the range of hours, thus offering a quantitative and objective method for the determination of PMIs.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Heart rate variability (HRV) and cardiorespiratory coordination, i.e. the temporal interplay between oscillations of heartbeat and respiration, reflect information related to the cardiovascular and autonomic nervous system. The purpose of this study was to investigate the relationship between spectral measures of HRV and measures of cardiorespiratory coordination. In 127 subjects from a normal population a 24 h Holter ECG was recorded. Average heart rate (HR) and the following HRV parameters were calculated: very low (VLF), low (LF) and high frequency (HF) oscillations and LF/HF. Cardiorespiratory coordination was quantified using average respiratory rate (RespR), the ratio of heart rate and respiratory rate (HRR), the phase coordination ratio (PCR) and the extent of cardiorespiratory coordination (PP). Pearson's correlation coefficient r was used to quantify the relationship between each pair of the variables across all subjects. HR and HRR correlated strongest during daytime (r = 0.89). LF/HF and PP showed a negative correlation to a reasonable degree (r = -0.69). During nighttime sleep these correlations decreased whereas the correlation between HRR and RespR (r = -0.47) as well as between HRR and PCR (r = 0.73) increased substantially. In conclusion, HRR and PCR deliver considerably different information compared to HRV measures whereas PP is partially linked reciprocally to LF/HF.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: Nitric oxide (NO), one of the most powerful endogenous vasodilators, is thought to play a major role in the development of delayed vasospasm in patients with subarachnoid hemorrhage (SAH). However, the role of the production of cerebral NO in patients with SAH is not known. In other SAH studies, NO metabolites such as nitrite and nitrate have been demonstrated to be decreased in cerebrospinal fluid and in plasma. METHODS: In this study, a microdialysis probe was used, along with a multiparameter sensor, to measure NO metabolites, brain tissue oxygen tension, brain tissue carbon dioxide tension, and pH in the cortex of patients with severe SAH who were at risk for developing secondary brain damage and vasospasm. NO metabolites, glucose, and lactate were analyzed in the dialysates to determine the time course of NO metabolite changes and to test the interrelationship between the analytes and clinical variables. RESULTS: Brain tissue oxygen tension was strongly correlated to dialysate nitrate and nitrite (r2 = 0.326; P < 0.001); however, no correlation was noted between brain tissue oxygen tension and NO metabolites in cerebrospinal fluid (r2 = 0.018; P = 0.734). No significant correlation between NO production, brain tissue carbon dioxide tension, and dialysate glucose and lactate was observed. CONCLUSION: Cerebral ischemia and compromised substrate delivery are often responsible for high morbidity rates and poor outcomes after SAH. The relationship between brain tissue oxygen and cerebral NO metabolites that we demonstrate suggests that substrate delivery and NO are linked in the pathophysiology of vasospasm after SAH.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Satellite measurement validations, climate models, atmospheric radiative transfer models and cloud models, all depend on accurate measurements of cloud particle size distributions, number densities, spatial distributions, and other parameters relevant to cloud microphysical processes. And many airborne instruments designed to measure size distributions and concentrations of cloud particles have large uncertainties in measuring number densities and size distributions of small ice crystals. HOLODEC (Holographic Detector for Clouds) is a new instrument that does not have many of these uncertainties and makes possible measurements that other probes have never made. The advantages of HOLODEC are inherent to the holographic method. In this dissertation, I describe HOLODEC, its in-situ measurements of cloud particles, and the results of its test flights. I present a hologram reconstruction algorithm that has a sample spacing that does not vary with reconstruction distance. This reconstruction algorithm accurately reconstructs the field to all distances inside a typical holographic measurement volume as proven by comparison with analytical solutions to the Huygens-Fresnel diffraction integral. It is fast to compute, and has diffraction limited resolution. Further, described herein is an algorithm that can find the position along the optical axis of small particles as well as large complex-shaped particles. I explain an implementation of these algorithms that is an efficient, robust, automated program that allows us to process holograms on a computer cluster in a reasonable time. I show size distributions and number densities of cloud particles, and show that they are within the uncertainty of independent measurements made with another measurement method. The feasibility of another cloud particle instrument that has advantages over new standard instruments is proven. These advantages include a unique ability to detect shattered particles using three-dimensional positions, and a sample volume size that does not vary with particle size or airspeed. It also is able to yield two-dimensional particle profiles using the same measurements.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fish behaviourists are increasingly turning to non-invasive measurement of steroid hormones in holding water, as opposed to blood plasma. When some of us met at a workshop in Faro, Portugal, in September, 2007, we realised that there were still many issues concerning the application of this procedure that needed resolution, including: Why do we measure release rates rather than just concentrations of steroids in the water? How does one interpret steroid release rates when dealing with fish of different sizes? What are the merits of measuring conjugated as well as free steroids in water? In the ‘static’ sampling procedure, where fish are placed in a separate container for a short period of time, does this affect steroid release—and, if so, how can it be minimised? After exposing a fish to a behavioural stimulus, when is the optimal time to sample? What is the minimum amount of validation when applying the procedure to a new species? The purpose of this review is to attempt to answer these questions and, in doing so, to emphasize that application of the non-invasive procedure requires more planning and validation than conventional plasma sampling. However, we consider that the rewards justify the extra effort.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Mercury has been known since ancient times. In fact, one mine, the "Almaden" in Spain, has been worked continuously since Roman times. It has been used during all this time for the recovery of free gold from gold concentrates, and from black sand and galena in concentrates from placer work.