964 resultados para spore dosimetry


Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE To study the factors associated with choice of therapy and prognosis in octogenarians with severe symptomatic aortic stenosis (AS). STUDY DESIGN Prospective, observational, multicenter registry. Centralized follow-up included survival status and, if possible, mode of death and Katz index. SETTING Transnational registry in Spain. SUBJECTS We included 928 patients aged ≥80 years with severe symptomatic AS. INTERVENTIONS Aortic-valve replacement (AVR), transcatheter aortic-valve implantation (TAVI) or conservative therapy. MAIN OUTCOME MEASURES All-cause death. RESULTS Mean age was 84.2 ± 3.5 years, and only 49.0% were independent (Katz index A). The most frequent planned management was conservative therapy in 423 (46%) patients, followed by TAVI in 261 (28%) and AVR in 244 (26%). The main reason against recommending AVR in 684 patients was high surgical risk [322 (47.1%)], other medical motives [193 (28.2%)], patient refusal [134 (19.6%)] and family refusal in the case of incompetent patients [35 (5.1%)]. The mean time from treatment decision to AVR was 4.8 ± 4.6 months and to TAVI 2.1 ± 3.2 months, P < 0.001. During follow-up (11.2-38.9 months), 357 patients (38.5%) died. Survival rates at 6, 12, 18 and 24 months were 81.8%, 72.6%, 64.1% and 57.3%, respectively. Planned intervention, adjusted for multiple propensity score, was associated with lower mortality when compared with planned conservative treatment: TAVI Hazard ratio (HR) 0.68 (95% confidence interval [CI] 0.49-0.93; P = 0.016) and AVR HR 0.56 (95% CI 0.39-0.8; P = 0.002). CONCLUSION Octogenarians with symptomatic severe AS are frequently managed conservatively. Planned conservative management is associated with a poor prognosis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

AbstractArbuscular Mycorrhizal Fungi (AMF) form obligate symbioses with the majority of land plants. These fungi influence the diversity and productivity of plants. AMF are unusual organisms, harbouring genetically different nuclei in a common cytoplasm (known as heterokaryosis). Genetic variability has been shown between AMF individuals coming from the same population. Recent findings showed that genetic exchange between genetically different AMF individuals was possible. Additionnaly, segregation was shown to occur at spore formation in AMF. These two processes were shown to increase genetic variability between AMF individuals.Because of the difficulty to study these organisms, almost nothing is known about the effect of intra-specific genetic variability in AMF on the plant transcriptome. The aim of this thesis was to bring insights into the effect of intra-specific genetic variability in AMF on plant gene transcription. We demonstrated that genetic exchange could influence expression of some symbiosis specific plant genes and the timing of the colonization of the fungi in plant roots. We also showed that segregation could have a large impact on plant gene transcription. Taken together, these results demonstrated that AMF intra-specific variability could profoundly affect the life of plants by altering various molecular pathways. Moreover, results obtained on rice open a field of research on AMF genetics in impromvment of growth in agricultural plants and should be taken into account for future experiments.RésuméLes champignons endomycorhiziens arbusculaires (CEA) forment une symbiose obligatoire avec la majorité des plantes sur terre. Ces champignons peuvent influencer la diversité et la productivité des plantes avec lesquelles ils forment la symbiose. Les CEA sont des organismes particuliers de part le fait qu'ils possèdent des noyaux génétiquement différents (appelés hétérocaryosis) dans un cytoplasme commun. Il a été montré qu'il existait de la variabilité génétique intra-specific chez les CEA. De plus, des études recentes ont montré que l'échange génétique chez les CEA était possible entre des individus génétiquement différents tout comme la ségrégation qui a aussi été démontrée au moment de la formation des nouvelles spores chez les CEA. Ces deux processus ont été montrés comme pouvant créer aussi de la variabilité génétique intra-specific.Du fait de la difficulté de travailler avec les CEA et à cause de la nouveauté de ces recherches, très peu de choses sont connues sur l'effet de l'échange génétique et de la ségrégation chez les CEA sur les plantes, et particulièrement au niveau moléculaire. Le but de cette thèse a été d'apporter la lumière sur les effets de la viariabilité génétique intra-specific chez les CEA, sur la transcription des gènes chez la plante. Nous avons pu montrer que l'échange génétique pouvait avoir des effets sur l'expression de gènes spécifiques à cette symbiose mais aussi pouvait influencer le timing de colonisation des racines de plantes par les CEA. Nous avons aussi montré que la ségrégation pouvait grandement influencer le transcriptome complet de la plante, et pas seulement les voies métaboliques spécifiques à la symbiose comme cela avait été montré auparavant.L'ensemble de ces résultats démontre l'importance de la variation intra-specific chez les CEA sur les plantes et leur implication sur leur cycle de vie en changeant l'expression de voies métaboliques. De plus, ces résultats obtenus sur le riz ouvrent un champ de recherches sur les plantes destinées à l'agriculture et devraient être pris en compte pour des expériences futures.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: Since 1982, the Radiation Oncology Group of the EORTC (EORTC ROG) has pursued an extensive Quality Assurance (QA) program involving all centres actively participating in its clinical research. The first step is the evaluation of the structure and of the human, technical and organisational resources of the centres, to assess their ability to comply with the current requirements for high-tech radiotherapy (RT). MATERIALS AND METHODS: A facility questionnaire (FQ) was developed in 1989 and adapted over the years to match the evolution of RT techniques. We report on the contents of the current FQ that was completed online by 98 active EORTC ROG member institutions from 19 countries, between December 2005 and October 2007. RESULTS: Similar to the data collected previously, large variations in equipment, staffing and workload between centres remain. Currently only 15 centres still use a Cobalt unit. All centres perform 3D Conformal RT, 79% of them can perform IMRT and 54% are able to deliver stereotactic RT. An external reference dosimetry audit (ERDA) was performed in 88% of the centres for photons and in 73% for electrons, but it was recent (<2 years) in only 74% and 60%, respectively. CONCLUSION: The use of the FQ helps maintain the minimum quality requirements within the EORTC ROG network: recommendations are made on the basis of the analysis of its results. The present analysis shows that modern RT techniques are widely implemented in the clinic but also that ERDA should be performed more frequently. Repeated assessment using the FQ is warranted to document the future evolution of the EORTC ROG institutions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND In this study, we evaluated the ability of gene expression profiles to predict chemotherapy response and survival in triple-negative breast cancer (TNBC). METHODS Gene expression and clinical-pathological data were evaluated in five independent cohorts, including three randomised clinical trials for a total of 1055 patients with TNBC, basal-like disease (BLBC) or both. Previously defined intrinsic molecular subtype and a proliferation signature were determined and tested. Each signature was tested using multivariable logistic regression models (for pCR (pathological complete response)) and Cox models (for survival). Within TNBC, interactions between each signature and the basal-like subtype (vs other subtypes) for predicting either pCR or survival were investigated. RESULTS Within TNBC, all intrinsic subtypes were identified but BLBC predominated (55-81%). Significant associations between genomic signatures and response and survival after chemotherapy were only identified within BLBC and not within TNBC as a whole. In particular, high expression of a previously identified proliferation signature, or low expression of the luminal A signature, was found independently associated with pCR and improved survival following chemotherapy across different cohorts. Significant interaction tests were only obtained between each signature and the BLBC subtype for prediction of chemotherapy response or survival. CONCLUSIONS The proliferation signature predicts response and improved survival after chemotherapy, but only within BLBC. This highlights the clinical implications of TNBC heterogeneity, and suggests that future clinical trials focused on this phenotypic subtype should consider stratifying patients as having BLBC or not.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this document is to provide general information about mIBG scintigraphy in cancer patients. The guidelines describe the mIBG scintigraphy protocol currently used in clinical routine, but do not include all existing procedures for neuroendocrine tumours. The guidelines should therefore not be taken as exclusive of other nuclear medicine modalities that can be used to obtain comparable results. It is important to remember that the resources and facilities available for patient care may vary from one country to another and from one medical institution to another. The present guidelines have been prepared for nuclear medicine physicians and intend to offer assistance in optimizing the diagnostic information that can currently be obtained from mIBG scintigraphy. The corresponding guidelines of the Society of Nuclear Medicine (SNM) and the Dosimetry, Therapy and Paediatric Committee of the EANM have been taken into consideration, and partially integrated into this text. The same has been done with the most relevant literature on this topic, and the final result has been discussed within a group of distinguished experts.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We present the long-term results of 18 chemotherapy relapsed indolent (N = 12) or transformed (N = 6) NHL patients of a phase II anti-CD20 (131)I-tositumomab (Bexxar) therapy study. The biphasic therapy included two injections of 450 mg unlabelled antibody combined with (131)I-tositumomab once as dosimetric and once as therapeutic activity delivering 75 or 65 cGy whole-body radiation dose to patients with normal or reduced platelet counts, respectively. Two patients were not treated due to disease progression during dosimetry. The overall response rate was 81% in the 16 patients treated, including 50% CR/CRu and 31% PR. Median progression free survival of the 16 patients was 22.5 months. Median overall survival has not been reached after a median observation of 48 months. Median PFS of complete responders (CR/CRu) has not been reached and will be greater than 51 months. Short-term side effects were mainly haematological and transient. Among the relevant long-term side effects, one patient previously treated with CHOP chemotherapy died from secondary myelodysplasia. Four patients developed HAMA. In conclusion, (131)I-tositumomab RIT demonstrated durable responses especially in those patients who achieved a complete response. Six of eight CR/CRu are ongoing after 46-70 months.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In vivo dosimetry is a way to verify the radiation dose delivered to the patient in measuring the dose generally during the first fraction of the treatment. It is the only dose delivery control based on a measurement performed during the treatment. In today's radiotherapy practice, the dose delivered to the patient is planned using 3D dose calculation algorithms and volumetric images representing the patient. Due to the high accuracy and precision necessary in radiation treatments, national and international organisations like ICRU and AAPM recommend the use of in vivo dosimetry. It is also mandatory in some countries like France. Various in vivo dosimetry methods have been developed during the past years. These methods are point-, line-, plane- or 3D dose controls. A 3D in vivo dosimetry provides the most information about the dose delivered to the patient, with respect to ID and 2D methods. However, to our knowledge, it is generally not routinely applied to patient treatments yet. The aim of this PhD thesis was to determine whether it is possible to reconstruct the 3D delivered dose using transmitted beam measurements in the context of narrow beams. An iterative dose reconstruction method has been described and implemented. The iterative algorithm includes a simple 3D dose calculation algorithm based on the convolution/superposition principle. The methodology was applied to narrow beams produced by a conventional 6 MV linac. The transmitted dose was measured using an array of ion chambers, as to simulate the linear nature of a tomotherapy detector. We showed that the iterative algorithm converges quickly and reconstructs the dose within a good agreement (at least 3% / 3 mm locally), which is inside the 5% recommended by the ICRU. Moreover it was demonstrated on phantom measurements that the proposed method allows us detecting some set-up errors and interfraction geometry modifications. We also have discussed the limitations of the 3D dose reconstruction for dose delivery error detection. Afterwards, stability tests of the tomotherapy MVCT built-in onboard detector was performed in order to evaluate if such a detector is suitable for 3D in-vivo dosimetry. The detector showed stability on short and long terms comparable to other imaging devices as the EPIDs, also used for in vivo dosimetry. Subsequently, a methodology for the dose reconstruction using the tomotherapy MVCT detector is proposed in the context of static irradiations. This manuscript is composed of two articles and a script providing further information related to this work. In the latter, the first chapter introduces the state-of-the-art of in vivo dosimetry and adaptive radiotherapy, and explains why we are interested in performing 3D dose reconstructions. In chapter 2 a dose calculation algorithm implemented for this work is reviewed with a detailed description of the physical parameters needed for calculating 3D absorbed dose distributions. The tomotherapy MVCT detector used for transit measurements and its characteristics are described in chapter 3. Chapter 4 contains a first article entitled '3D dose reconstruction for narrow beams using ion chamber array measurements', which describes the dose reconstruction method and presents tests of the methodology on phantoms irradiated with 6 MV narrow photon beams. Chapter 5 contains a second article 'Stability of the Helical TomoTherapy HiArt II detector for treatment beam irradiations. A dose reconstruction process specific to the use of the tomotherapy MVCT detector is presented in chapter 6. A discussion and perspectives of the PhD thesis are presented in chapter 7, followed by a conclusion in chapter 8. The tomotherapy treatment device is described in appendix 1 and an overview of 3D conformai- and intensity modulated radiotherapy is presented in appendix 2. - La dosimétrie in vivo est une technique utilisée pour vérifier la dose délivrée au patient en faisant une mesure, généralement pendant la première séance du traitement. Il s'agit de la seule technique de contrôle de la dose délivrée basée sur une mesure réalisée durant l'irradiation du patient. La dose au patient est calculée au moyen d'algorithmes 3D utilisant des images volumétriques du patient. En raison de la haute précision nécessaire lors des traitements de radiothérapie, des organismes nationaux et internationaux tels que l'ICRU et l'AAPM recommandent l'utilisation de la dosimétrie in vivo, qui est devenue obligatoire dans certains pays dont la France. Diverses méthodes de dosimétrie in vivo existent. Elles peuvent être classées en dosimétrie ponctuelle, planaire ou tridimensionnelle. La dosimétrie 3D est celle qui fournit le plus d'information sur la dose délivrée. Cependant, à notre connaissance, elle n'est généralement pas appliquée dans la routine clinique. Le but de cette recherche était de déterminer s'il est possible de reconstruire la dose 3D délivrée en se basant sur des mesures de la dose transmise, dans le contexte des faisceaux étroits. Une méthode itérative de reconstruction de la dose a été décrite et implémentée. L'algorithme itératif contient un algorithme simple basé sur le principe de convolution/superposition pour le calcul de la dose. La dose transmise a été mesurée à l'aide d'une série de chambres à ionisations alignées afin de simuler la nature linéaire du détecteur de la tomothérapie. Nous avons montré que l'algorithme itératif converge rapidement et qu'il permet de reconstruire la dose délivrée avec une bonne précision (au moins 3 % localement / 3 mm). De plus, nous avons démontré que cette méthode permet de détecter certaines erreurs de positionnement du patient, ainsi que des modifications géométriques qui peuvent subvenir entre les séances de traitement. Nous avons discuté les limites de cette méthode pour la détection de certaines erreurs d'irradiation. Par la suite, des tests de stabilité du détecteur MVCT intégré à la tomothérapie ont été effectués, dans le but de déterminer si ce dernier peut être utilisé pour la dosimétrie in vivo. Ce détecteur a démontré une stabilité à court et à long terme comparable à d'autres détecteurs tels que les EPIDs également utilisés pour l'imagerie et la dosimétrie in vivo. Pour finir, une adaptation de la méthode de reconstruction de la dose a été proposée afin de pouvoir l'implémenter sur une installation de tomothérapie. Ce manuscrit est composé de deux articles et d'un script contenant des informations supplémentaires sur ce travail. Dans ce dernier, le premier chapitre introduit l'état de l'art de la dosimétrie in vivo et de la radiothérapie adaptative, et explique pourquoi nous nous intéressons à la reconstruction 3D de la dose délivrée. Dans le chapitre 2, l'algorithme 3D de calcul de dose implémenté pour ce travail est décrit, ainsi que les paramètres physiques principaux nécessaires pour le calcul de dose. Les caractéristiques du détecteur MVCT de la tomothérapie utilisé pour les mesures de transit sont décrites dans le chapitre 3. Le chapitre 4 contient un premier article intitulé '3D dose reconstruction for narrow beams using ion chamber array measurements', qui décrit la méthode de reconstruction et présente des tests de la méthodologie sur des fantômes irradiés avec des faisceaux étroits. Le chapitre 5 contient un second article intitulé 'Stability of the Helical TomoTherapy HiArt II detector for treatment beam irradiations'. Un procédé de reconstruction de la dose spécifique pour l'utilisation du détecteur MVCT de la tomothérapie est présenté au chapitre 6. Une discussion et les perspectives de la thèse de doctorat sont présentées au chapitre 7, suivies par une conclusion au chapitre 8. Le concept de la tomothérapie est exposé dans l'annexe 1. Pour finir, la radiothérapie «informationnelle 3D et la radiothérapie par modulation d'intensité sont présentées dans l'annexe 2.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A questionnaire was developed by the members of WG12 of EURADOS in order to establish an overview of the current status of eye lens radiation dose monitoring in hospitals. The questionnaire was sent to medical physicists and radiation protection officers in hospitals across Europe. Specific topics were addressed in the questionnaire such as: knowledge of the proposed eye lens dose limit; monitoring and dosimetry issues; training and radiation protection measures. The results of the survey highlighted that the new eye lens dose limit can be exceeded in interventional radiology procedures and that eye lens protection is crucial. Personnel should be properly trained in how to use protective equipment in order to keep eye lens doses as low as reasonably achievable. Finally, the results also highlighted the need to improve the design of eye dosemeters in order to ensure satisfactory use by workers.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Monte Carlo simulations were carried out to study the response of a thyroid monitor for measuring intake activities of (125)I and (131)I. The aim of the study was 3-fold: to cross-validate the Monte Carlo simulation programs, to study the response of the detector using different phantoms and to study the effects of anatomical variations. Simulations were performed using the Swiss reference phantom and several voxelised phantoms. Determining the position of the thyroid is crucial for an accurate determination of radiological risks. The detector response using the Swiss reference phantom was in fairly good agreement with the response obtained using adult voxelised phantoms for (131)I, but should be revised for a better calibration for (125)I and for any measurements taken on paediatric patients.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

While it is now well accepted that radiolabeled antibodies can be useful for tumour detection by immunoscintigraphy, the use of larger doses of more aggressive radioisotopes coupled to antibodies for radioimmunotherapy is still in its infancy. At the experimental level, our group has shown that the intravenous injection of large doses of 131I labeled F(ab')2 fragments from monoclonal anti-carcinoembryonic antigen (CEA) antibodies can eradicate well established human colon carcinoma xenografts in nude mice. At the clinical level, in a dosimetry study performed at the Institut Gustave Roussy, the same anti-CEA monoclonal antibodies and fragments, labeled with subtherapeutic doses of 131I, were injected in patients with liver metastases from colorectal carcinomas. Direct measurement of radioactivity in surgically resected liver metastases and normal liver confirmed the specificity of tumour localization of the antibodies, but also showed that the calculated radiation doses which could be delivered by injections of 200 to 300 mCi of 131I labeled antibodies or fragments, remained fairly low, in the range of 1,500 to 3,000 rads. This is obviously insufficient for a single modality treatment. An alternative approach is to inject radiolabeled antibodies intra peritoneally to treat peritoneal carcinomatosis. Several clinical studies using this strategy are presently under evaluation and suggest that positive results can be obtained when the tumour diameters are very small. In systemic radioimmunotherapy, positive results have been obtained in more radiosensitive types of malignancies such as B cell lymphomas by intravenous injection of antibodies directed against B cell differentiation markers or against idiotypic antigens from each lymphoma, and labeled with 131I or 90Y. The major directions of research for improvement of radioimmunotherapy include the design of genetically engineered new forms of humanized antibodies, the synthesis of original chelates for coupling new radioisotopes to antibodies and the development of two step strategies for immunolocalization of radioisotopes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Radioimmunodetection of tumours with monoclonal antibodies is becoming an established procedure. Positron emission tomography (PET) shows better resolution than normal gamma camera single photon emission tomography and can provide more precise quantitative data. Thus, in the present study, these powerful methods have been combined to perform radioimmuno PET (RI-PET). Monoclonal antibodies directed against carcinoembryonic antigen (CEA) an IgG, its F(ab')2 and a mouse-human chimeric IgG derived from it were labelled with 124I, a positron-emitting radionuclide with a convenient physical half-life of four days. Mice, xenografted with a CEA-producing human colon carcinoma, were injected with the 124I-MAb and the tumours were visualized using PET. The concentrations of 124I in tumour and normal tissue were determined by both PET and direct radioactivity counting of the dissected animals, with very good agreement. To allow PET quantification, a procedure was established to account for the presence of radioactivity during the absorption correction measurement (transmission scan). Comparison of PET and tissue counting indicates that this novel combination of radioimmunolocalization and PET (RI-PET) will provide, in addition to more precise diagnosis, more accurate radiation dosimetry for radioimmunotherapy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fungal symbionts commonly occur in plants influencing host growth, physiology, and ecology (Carlile et al., 2001). However, while whole-plant growth responses to biotrophic fungi are readily demonstrated, it has been much more difficult to identify and detect the physiological mechanisms responsible. Previous work on the clonal grass Glyceria striata has revealed that the systemic fungal endophyte Epichloë glyceriae has a positive effect on clonal growth of its host (Pan & Clay, 2002; 2003). The latest study from these authors, in this issue (pp. 467- 475), now suggests that increased carbon movement in hosts infected by E. glyceriae may function as one mechanism by which endophytic fungi could increase plant growth. Given the widespread distribution of both clonal plants and symbiotic fungi, this research will have implications for our understanding of the ecology and evolution of fungus-plant associations in natural communities.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study seeks to perform a survey of patterns of practice among the different physicians involved in the bone metastases management, with special focus on external beam radiotherapy (EBRT).A questionnaire about bone metastases based on clinical cases and supplemented with general questions, including medical therapies, EBRT and metabolic radiotherapy strategies, surgery, and supportive care approaches, was sent to 4,706 French-speaking physicians in Belgium, France, Luxemburg, and Switzerland.Overall, 644 questionnaires were analyzed. Twenty-eight percent concerned the radiotherapy approach and were judged adequate to respond to the part dedicated to EBRT. Sixty-nine percent of physicians used a total dose irradiation of 30 Gy delivered in ten fractions. A large majority (75%) used two opposed fields prescribed at mid-depth (30%), or with non-equally weighted fields (45%). Seventy percent irradiated also above and below the concerned vertebra. A dosimetry planning treatment was done in 85% and high-energy megavoltage photons were used in 42%. Moreover, 54% physicians used short course radiotherapy in routine.Radiotherapy remains the mainstay of treatment of bone metastases, but there is substantial heterogeneity in clinical practice. Guidelines and treatment protocols are required to improve the treatment quality.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: The EORTC 22043-30041 trial investigates the role of the addition of androgen suppression to post-operative radiotherapy in patients who have undergone radical prostatectomy. As part of the quality assurance of radiotherapy (QART) a Dummy Run (DR) procedure was performed. MATERIALS AND METHOD: The protocol included detailed and published delineation guidelines. Participating institutions digitally submitted radiotherapy treatment volumes and a treatment plan for a standard clinical case. Submissions were centrally reviewed using the VODCA software platform. RESULTS: Thirty-eight submissions from thirty-one institutions were reviewed. Six were accepted without comments. Twenty-three were accepted with comments on one or more items: target volume delineation (22), OAR delineation (23), planning and dosimetry (3) or treatment verification (1). Nine submissions were rejected requiring resubmission, seven for target volume delineation reasons alone. Intervention to highlight the importance of delineation guidelines was made prior to the entry of the first patient in the trial. After this, a lower percentage of resubmissions was required. CONCLUSIONS: The EORTC 22043-30041 Dummy Run highlights the need for timely and effective QART in clinical trials. The variation in target volume and OAR definition demonstrates that clinical guidelines and radiotherapy protocols are not a substitute for QART procedures. Early intervention in response to the Dummy Run improved protocol understanding.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Mutation of the Schizosaccharomyces pombe cdc7 gene prevents formation of the division septum and cytokinesis. We have cloned the cdc7 gene and show that it encodes a protein kinase which is essential for cell division. In the absence of cdc7 function, spore germination, DNA synthesis and mitosis are unaffected, but cells are unable to initiate formation of the division septum. Overexpression of p120cdc7 causes cell cycle arrest; cells complete mitosis and then undergo multiple rounds of septum formation without cell cleavage. This phenotype, which is similar to that resulting from inactivation of cdc16 protein, requires the kinase activity of p120cdc7. Mutations inactivating the early septation gene, cdc11, suppress the formation of multiple septa and allow cells to proliferate normally. If formation of the division septum is prevented by inactivation of either cdc14 or cdc15, p120cdc7 overproduction does not interfere with other events in the mitotic cell cycle. Septation is not induced by overexpression of p120cdc7 in G2 arrested cells, indicating that it does not bypass the normal dependency of septation upon initiation of mitosis. These findings indicate that the p120cdc7 protein kinase plays a key role in initiation of septum formation and cytokinesis in fission yeast and suggest that p120cdc7 interacts with the cdc11 protein in the control of septation.