968 resultados para sensory-neural hearing loss
Resumo:
Nonsyndromic autosomal recessive deafness accounts for 80% of hereditary deafness. To date, 52 loci responsible for autosomal recessive deafness have been mapped and 24 genes identified. Here, we report a large inbred Brazilian pedigree with 26 subjects affected by prelingual deafness. Given the extensive consanguinity found in this pedigree, the most probable pattern of inheritance is autosomal recessive. However, our linkage and mutational analysis revealed, instead of an expected homozygous mutation in a single gene, two different mutant alleles and a possible third undetected mutant allele in the MYO15A gene (DFNB3 locus), as well as evidence for other causes for deafness in the same pedigree. Among the 26 affected subjects, 15 were homozygous for the novel c.10573delA mutation in the MYO15A gene, 5 were compound heterozygous for the mutation c.10573delA and the novel deletion c.9957_9960delTGAC and one inherited only a single c.10573delA mutant allele, while the other one could not be identified. Given the extensive consanguinity of the pedigree, there might be at least one more deafness locus segregating to explain the condition in some of the subjects whose deafness is not clearly associated with MYO15A mutations, although overlooked environmental causes could not be ruled out. Our findings illustrate a high level of etiological heterogeneity for deafness in the family and highlight some of the pitfalls of genetic analysis of large genes in extended pedigrees, when homozygosity for a single mutant allele is expected.
Resumo:
The OTOF gene encoding otoferlin is associated with auditory neuropathy (AN), a type of non-syndromic deafness. We investigated the contribution of OTOF mutations to AN and to non-syndromic recessive deafness in Brazil. A test for the Q829X mutation was carried out on a sample of 342 unrelated individuals with non-syndromic hearing loss, but none presented this mutation. We selected 48 cases suggestive of autosomal recessive inheritance, plus four familial and seven isolated cases of AN, for genotyping of five microsatellite markers linked to the OTOF gene. The haplotype analysis showed compatibility with linkage in 11 families (including the four families with AN). Samples of the 11 probands from these families and from seven isolated cases of AN were selected for an exon-by-exon screening for mutations in the OTOF gene. Ten different pathogenic variants were detected, among which six are novel. Among the 52 pedigrees with autosomal recessive inheritance (including four familial cases of AN), mutations were identified in 4 (7.7%). Among the 11 probands with AN, seven had at least one pathogenic mutation in the OTOF gene. Mutations in the OTOF gene are frequent causes of AN in Brazil and our results confirm that they are spread worldwide. Journal of Human Genetics (2009) 54, 382-385; doi: 10.1038/jhg.2009.45; published online 22 May 2009
Resumo:
Among lampyrids, intraspecific sexual communication is facilitated by spectral correspondence between visual sensitivity and bioluminescence emission from the single lantern in the tail. Could a similar strategy be utilized by the elaterids (click beetles), which have one ventral abdominal and two dorsal prothoracic lanterns? Spectral sensitivity [S(lambda)] and bioluminescence were investigated in four Brazilian click beetle species Fulgeochlizus bruchii, Pyrearinus termitilluminans, Pyrophorus punctatissimus and P. divergens, representing three genera. In addition, in situ microspectrophotometric absorption spectra were obtained for visual and screening pigments in P. punctatissimus and P. divergens species. In all species, the electroretinographic S(lambda) functions showed broad peaks in the green with a shoulder in the near-ultraviolet, suggesting the presence of short- and long-wavelength receptors in the compound eyes. The long-wavelength receptor in Pyrophorus species is mediated by a P540 rhodopsin in conjunction with a species-specific screening pigment. A correspondence was found between green to yellow bioluminescence emissions and its broad S(lambda) maximum in each of the four species. It is hypothesized that in elaterids, bioluminescence of the abdominal lantern is an optical signal for intraspecifc sexual communication, while the signals from the prothoracic lanterns serve to warn predators and may also provide illumination in flight.
Resumo:
Objetivos: avaliar a prevalência de alterações auditivas em recém-nascidos de muito baixo peso na Unidade de Tratamento Intensivo Neonatal do Hospital de Clínicas de Porto Alegre e estudar as variáveis que possam estar relacionadas com as alterações da acui-dade auditiva. Métodos: foi realizado um estudo transversal que incluiu todos os recém-nascidos de muito baixo peso admitidos na Unidade de Tratamento Intensivo Neonatal do Hospital de Clínicas de Porto Alegre no período de 1o de setembro de 2001 a 31 de janeiro de 2002. To-dos os pacientes foram submetidos ao exame de otoemissão acústica evocada por produto de distorção no momento da alta hospitalar. O exame foi repetido em 30 dias quando havia alte-ração no primeiro exame. Quando o paciente apresentava o exame de otoemissão acústica al-terada em duas ocasiões, era realizado o potencial auditivo evocado cerebral, considerado al-terado a partir de 35 dB NA. Resultados: foram estudados 96 recém-nascidos. Seis tiveram tanto o exame de otoemissão acústica quanto o potencial auditivo evocado cerebral alterados. A média da idade gestacional foi de 31,5 ± 2,6 semanas, o peso de nascimento variou de 640 a 1.500 g e 57,3% dos pacientes eram do sexo feminino. A idade gestacional e o índice de Apgar no 5o minuto foram inferiores no grupo otoemissão acústica e potencial auditivo evocado cerebral alterados em relação aos demais grupos, atingindo significância limítrofe. Conclusões: a prevalência de perda auditiva nos recém-nascidos de muito baixo peso da Unidade de Tratamento Intensivo Neonatal do Hospital de Clínicas de Porto Alegre foi de 6,3%, tendo sido observadas associações de significância limítrofe com idade gestacional e índice de Apgar no 5o minuto.
Resumo:
Introdução: O zumbido é definido como uma sensação auditiva ilusória sem a presença de um som externo. Acomete homens e mulheres, mais comumente entre 40 e 70 anos de idade, às vezes podendo ocorrer em crianças. Análises de dados epidemiológicos indicam que a exposição ao ruído é uma das causas mais comuns de zumbido. Objetivos: Os objetivos gerais deste estudo foram verificar a prevalência do zumbido em trabalhadores expostos ao ruído ocupacional e avaliar a freqüência e a intensidade do zumbido. Os objetivos específicos foram avaliar a gravidade do zumbido; analisar a presença do zumbido por sexo, cor, idade e tempo de trabalho com exposição ao ruído e analisar a relação do zumbido com as freqüências mais acometidas na audiometria e com a presença e grau da perda auditiva, independente do nexo da perda. Materiais e Métodos: Trata-se de um estudo transversal para o qual foram selecionados 362 prontuários de trabalhadores expostos a ruído ocupacional ≥80dB(NA)/8h diárias. Estes trabalhadores haviam sido submetidos a meatoscopia, anamnese clínica e ocupacional, audiometria de via aérea, avaliação de freqüência e intensidade do zumbido e à escala de avaliação da gravidade do zumbido. Conclusão: A prevalência do zumbido foi de 9,9%. Nas análises de regressão conclui-se que trabalhadores com presença de perda auditiva em pelo menos um dos ouvidos têm 2,396 vezes mais chances de ter zumbido quando comparados com os que não tem perda auditiva. Os trabalhadores com faixa etária acima ou igual a 30 anos tem 5,353 vezes mais chances de ter perda auditiva em pelo menos um dos ouvidos quando comparados com os de faixa etária menor que 30 anos. Com relação ao tempo de trabalho em contato com o ruído, a analise estatística revela que trabalhadores com diferença de 1 ano no tempo de trabalho em contato com ruído tem um risco 5,3 % (OR=1,053) maior de apresentar perda auditiva.
Resumo:
The rationalization of work in the Dentistry has been taking the professional to work for ways and systems based in the ergonomics, turning their work efficient and less tiring. Since their academic formation, the dentists surgeons are concerned with the high productivity in clinic and with the final result of the work, neglecting the way as it is executed, which reduce their work capacity and exhibits them to occupational diseases that could be minimized and/or forewarned. This research had as the main objective to investigate the knowledge of the Dentistry academics of Rio Grande do Norte Federal University concerning the Noise-induced Hearing Loss (NIHL), relating them at the noise levels that they are exposed, as well as to the preventive measures taken during the clinical activities. Was observed that 95% of the individuals know that the dentist surgeon is a professional in risk for NIHL. Among the causes of NIHL, the one that obtained the largest frequency citation was the high-speed handpieces, reminded by 92,4% of the academics. Among the students which enumerated protective measures for NIHL, 92% mentioned the use of the ear plugs, although 97% of the researched have told do not use any kind of preventive measure related to the noise. Was also observed that 96% of the academics notice the noise during the clinical attendance, what inconvenience 28,1% of them. Related the noise levels, the high-speed handpieces of the academics presented a medium value of 80,5 dB varying from 72,3 to 88,3 dB. The average of the ambient noise observed at the Integrated Clinic was about 74,8 dB. In spite of the noise levels in this research were observed below the established limits of tolerance by the legislation, they can provoke damages to the Dentistry professionals' health, or that suggests the need of an intervention and use of immediate preventive measures able to generate a healthy atmosphere of work and less risky
Resumo:
Frequentemente, os indivíduos com perda auditiva têm dificuldade de entender a fala no ambiente ruidoso. OBJETIVO: O objetivo deste estudo foi avaliar clinicamente o desempenho dos indivíduos adultos com deficiência auditiva neurossensorial, com relação à percepção da fala, utilizando o aparelho de amplificação sonora individual digital com o algoritmo de redução de ruído denominado Speech Sensitive Processing, ativado e desativado na presença de um ruído. MATERIAL E MÉTODO: Este estudo de casos foi realizado em 32 indivíduos com deficiência auditiva neurossensorial de graus leve, moderado ou leve a moderado. Foi realizada a avaliação por meio de um teste de percepção de fala, onde se pesquisou o reconhecimento de sentenças na presença de um ruído, para obter a relação sinal/ruído, utilizando o aparelho auditivo digital. RESULTADOS: O algoritmo pôde proporcionar benefício para a maioria dos indivíduos deficientes auditivos, na pesquisa da relação sinal/ruído e os resultados apontaram diferença estatisticamente significante na condição em que o algoritmo encontrava-se ativado, comparado quando o algoritmo não se encontrava ativado. CONCLUSÃO: O uso do algoritmo de redução de ruído deve ser pensado como alternativa clínica, pois observamos a eficácia desse sistema na redução do ruído, melhorando a percepção da fala.
Resumo:
Most cochlear implant (CI) users, who suffer from post lingual hearing loss, are able to perceive sounds and comprehend speech after the implant. The prediction of maximal benefit over time, with the use of CI, can be useful for counseling patients about their expectations in using the new device. The measurement of satisfaction should be of primary interest in medical intervention, as the results may be used for intervention feedback. The purpose of this study is to analyze auditory performance of CI over time, as well as to evaluate users‟ satisfaction. Therefore two types of study designs were employed: a) retrospective cohort study with the analysis of medical records from 59 subjects about auditory performance before and after surgery. Results were submitted to the Kaplan -Meier estimator of cumulative probability and compared to prognostic factors of auditory performance using the logrank test. b) A sectional study design was conducted to evaluate the satisfaction of 51 subjects. The instrument consists of two specific questionnaires: Satisfaction with Amplification in Daily Life SADL and International Outcome Inventory Cochlear Implant IOI- CI. Results show statistical significant differences (p<0,001) in auditory performance before and after CI. The majority obtained satisfactory results of CI use during the first six months. Logrank tests does not indicate significant correlation between the analyzed covariates and the time in which adequate speech perception occurs. SADL e IOI-CI questionnaires indicate that most of the CI users are satisfied with their devices. The SADL detected a 27, 5% insatisfaction amongst CI users in relation to services and costs involved with the CI. The results of the IOI show 4% of insatisfaction with the use of CI and the social environment. In conclusion CI is capable to rehabilitate social auditory function in a short period of time and CI users demonstrate satisfaction with auditory, social and psychological gain offered through CI device
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
A síndrome G/BBB é uma condição rara, caracterizada por hipertelorismo, fissura de lábio e palato e hipospádia. Não foram encontrados trabalhos sobre a audição em indivíduos com esta síndrome. OBJETIVO: Investigar a função auditiva em pacientes com síndrome G/BBB quanto à ocorrência ou não de perda auditiva e a condução nervosa auditiva periférica e central. MATERIAL E MÉTODO: Catorze pacientes de 7 a 34 anos, do gênero masculino, com a síndrome G/BBB, foram avaliados por meio de otoscopia, audiometria, timpanometria e potenciais evocados auditivos de tronco encefálico (PEATE). Forma de Estudo: Estudo de série clínico prospectivo. RESULTADOS: Limiares audiométricos normais em 12 (66,7%) pacientes da amostra e alterados em dois (33,3%), sendo um com perda condutiva e um neurossensorial. Quanto ao PEATE, foram encontrados: latências absolutas da onda I normais em todos os pacientes, aumento das latências absolutas da onda III e V em dois e seis pacientes respectivamente; latências interpicos I-III, III-V e I-V aumentadas em quatro, três e oito pacientes, respectivamente. CONCLUSÃO: Perdas auditivas periféricas podem ocorrer na síndrome G/BBB. Há evidências de comprometimento das vias auditivas centrais em nível do tronco encefálico. Estudos com exames de imagem são necessários para maior clareza dos achados clínicos.
Resumo:
Police officers are exposed to impact noise coming from firearms, which may cause irreversible injuries to the hearing system.Aim: To evaluate the noise exposure in shooting stands during gunfire exercises, to analyze the acoustic impact of the noise produced by the firearms and to associate it with tonal audiometry results.Study design: Cross-sectional.Materials and methods: To measure noise intensity we used a digital sound level meter, and the acoustic analysis was carried out by means of the oscillations and cochlear response curves provided by the Praat software. 30 police officers were selected (27 males and 3 females).Results: The peak level measured was 113.1 dB(C) from a .40 pistol and 116.8 dB(C) for a .38 revolver. The values obtained for oscillation and Praat was 17.9 +/- 0.3 Barks, corresponding to the rate of 4,120 and 4,580 Hz. Audiometry indicated greater hearing loss at 4,000Hz in 86.7% of the cases.Conclusion: With the acoustic analysis it was possible to show cause and effect between the main areas of energy excitation of the cochlea (Praat cochlear response curve) and the frequencies of low hearing acuity.
Resumo:
Leprosy affects the larynx, damaging its mucosa and sensory nerves and loss of sensation may result in aspiration of food and secretions. The laryngeal lesion may be insidious. Post-mortem studies showed bronchopneumonia that could have originated from aspiration. In patients with laryngeal symptoms, dysphagia or aspiration pneumonia loss of laryngeal sensation should be looked for.
Resumo:
Objectives: We performed a prospective clinical study of the cochleovestibular symptoms and the risk cofactors and characteristics of hearing loss in patients with type 1 diabetes.Methods: Group I consisted of 40 patients with type I diabetes, and group 2 consisted of 20 control subjects without diabetes. All participants answered a questionnaire, and their medical records were reviewed. They also were submitted to otorhinolaryngological examinations and to auditory tests (pure tone audiometry and acoustic immitance and auditory brain stem response [ABR] tests).Results: Dyslipidemia, hypertension, retinopathy, and diabetic neuropathy were not frequent in the patients of group 1, but incipient nephropathy was present in 47.5% of them. The most frequent cochleovestibular symptoms were tinnitus and hearing loss. Sensorineural hearing loss was found in 4 patients of group I and was predominantly bilateral, symmetric, and affecting the high frequencies, coexisting with normal vocal discrimination. These patients had a longer time from diabetes diagnosis and had poor glycemia control. A delay of ABR interpeak latency I-III was observed in 11.25% of the group I ears. All patients of group 2 presented normal audiograms and ABR tests.Conclusions: In group 1, the most frequent cochleovestibular symptoms were tinnitus and hearing loss. The sensorineural hearing loss was mild, symmetric, and predominantly high-frequency. A delay of ABR interpeak latencies was detected in the patients of group I who had normal audiometric thresholds.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
OBJETIVOS: identificar a prevalência de hipoacusia em crianças indígenas Kaiowá e Guarani. MÉTODOS: estudo transversal, com uma amostra de 126 crianças indígenas de zero a 59 meses da Terra Indígena de Caarapó, em Mato Grosso do Sul, Brasil. As crianças foram submetidas ao exame das emissões otoacústicas evocadas transitórias, que serviu como triagem auditiva. O reteste foi realizado nas crianças que apresentaram resultado alterado na triagem auditiva. Os casos que, no reteste, permaneceram alterados foram encaminhados para o exame da imitanciometria. RESULTADOS: na triagem auditiva, foram identificadas 25 (23,6%) crianças com resultado alterado; dessas, 17 apresentaram resultado normal no reteste e 6 permaneceram com resultado alterado, sendo encaminhadas para imitanciometria. A prevalência de hipoacusia identificada ao final do estudo foi de 5,6%, sendo 3 (2,8%) do tipo condutiva e 3 (2,8%) do tipo neurossensorial. Estas últimas foram encaminhadas à avaliação otorrinolaringológica complementar para confirmação diagnóstica. As alterações auditivas identificadas neste estudo não apresentaram diferenças significantes quanto ao sexo e grupo etário. CONCLUSÕES: a prevalência de alteração auditiva encontrada nesta população alerta para a necessidade de implantação de programas de saúde auditiva e sua articulação com outras ações desenvolvidas na atenção à saúde infantil dos Kaiowá e Guarani.