958 resultados para reliability measurement
Resumo:
The Test of Mouse Proficiency (TOMP) was developed to assist occupational therapists and education professionals assess computer mouse competency skills in children from preschool to upper primary (elementary) school age. The preliminary reliability and validity of TOMP are reported in this paper. Methods used to examine the internal consistency, test-retest reliability, and criterion- and construct-related validity of the test are elaborated. In the continuing process of test refinement, these preliminary studies support to varying degrees the reliability and validity of TOMP. Recommendations for further validation of the assessment are discussed along with indications for potential clinical application.
Resumo:
For products sold with warranty, the warranty servicing cost can be reduced by improving product reliability through a development process. However, this increases the unit manufacturing cost. Optimal development must achieve a trade-off between these two costs. The outcome of the development process is uncertain and needs to be taken into account in the determination of the optimal development effort. The paper develops a model where this uncertainty is taken into account. (C) 2003 Elsevier Ltd. All rights reserved.
Resumo:
This article presents Monte Carlo techniques for estimating network reliability. For highly reliable networks, techniques based on graph evolution models provide very good performance. However, they are known to have significant simulation cost. An existing hybrid scheme (based on partitioning the time space) is available to speed up the simulations; however, there are difficulties with optimizing the important parameter associated with this scheme. To overcome these difficulties, a new hybrid scheme (based on partitioning the edge set) is proposed in this article. The proposed scheme shows orders of magnitude improvement of performance over the existing techniques in certain classes of network. It also provides reliability bounds with little overhead.
Resumo:
This paper reports a study that explored a new construct: climate of fear. We hypothesised that climate of fear would vary across work sites within organisations, but not across organisations. This is in contrast a to measures of organisational culture, which were expected to vary both within and across organisations. To test our hypotheses, we developed a new 13-item measure of perceived fear in organisations and tested it in 20 sites across two organisations (N = 209). Culture variables measured were innovative leadership culture, and communication culture. Results were that climate of fear did vary across sites in both organisations, while differences across organisations were not significant, as we anticipated. Organisational culture, however, varied between the organisations, and within one of the organisations. The climate of fear scale exhibited acceptable psychometric properties.
Resumo:
To investigate the ability of ultrasonography to estimate musactivity, we measured architectural parameters (pennation angles, fascicle lengths, and muscle thickness) of several human muscles (tibialis anterior, biceps brachii, brachialis, transversus abdominis, obliquus internus abdominis, and obliquus externus abdominis) during isometric contractions of from 0 to 100% maximal voluntary contraction (MVC). Concurrently, electromyographic (EMG) activity was measured with surface (tibialis anterior only) or fine-wire electrodes. Most architectural parameters changed markedly with contractions up to 30% MVC but changed little at higher levels of contraction. Thus, ultrasound imaging can be used to detect low levels of muscle activity but cannot discriminate between moderate and strong contractions. Ultrasound measures could reliably detect changes in EMG of as little as 4% MVC (biceps muscle thickness), 5% MVC (brachialis muscle thickness), or 9% MVC (tibialis anterior pennation angle). They were generally less sensitive to changes in abdominal muscle activity, but it was possible to reliably detect contractions of 12% MVC in transversus abdominis (muscle length) and 22% MVC in obliquus internus (muscle thickness). Obliquus externus abdominis thickness did not change consistently with muscle contraction, so ultrasound measures of thickness cannot be used to detect activity of this muscle. Ultrasound imaging can thus provide a non-invasive method of detecting isometric muscle contractions of certain individual muscles.
Resumo:
Purpose: This study measured reliability between stroke patients' and significant others' scores on items on the Reintegration to Normal Living (RNL) Index and whether there were any scoring biases. Method The 11-item RNL Index was administered to 57 pairs of patients and significants six months after stroke rehabilitation. The index was scored using a 10-point visual analogue scale. Patient and significant other demographic information and data on patients' clinical, functional and cognitive status were collected. Reliability was measured using the intra-class correlation coefficient (ICC) and percent agreement. Results: Overall poor reliability was found for the RNL Index total score (ICC=.36, 95% CI. 07 to .59) and the daily functioning subscale (ICC=.24, 95% CI -.003 to .46) and moderate reliability was found for the perception of self subscale (ICC=.55, 95 % CI .28 to .73). There was a moderate bias for patients to rate themselves as achieving better reintegration than was indicated by significant others, although no demographic or clinical factors were associated with this bias. Exact match agreement was best for the subjective items and worse for items reflecting mobility around the community and participation in a work activity. Conclusions: Caution is needed when interpreting patient information reported by significant others on the RNL Index. The use of a shorter scale to rate the RNL Index requires investigation.
Resumo:
Measurement of Health-Related Quality of Life (HRQoL) of the elderly requires instruments with demonstrated sensitivity, reliability, and validity, particularly with the increasing proportion of older people entering the health care system. This article reports the psychometric properties of the 12-item Assessment of Quality of Life (AQoL) instrument in chronically ill community-dwelling elderly people with an 18-month follow-up. Comparator instruments included the SF-36 and the OARS. Construct validity of the AQoL was strong when examined via factor analysis and convergent and divergent validity against other scales. Receiver Operator Characteristic (ROC) curve analyses and relative efficiency estimates indicated the AQoL is sensitive, responsive, and had the strongest predicative validity for nursing home entry. It was also sensitive to economic prediction over the follow-up. Given these robust psychometric properties and the brevity of the scale, AQoL appears to be a suitable instrument for epidemiologic studies where HRQoL and utility data are required from elderly populations. (C) 2003 Elsevier Science Inc. All rights reserved.
Resumo:
Background. The purpose of this study was to examine the reliability of stage of change (SOC) measures for moderate-intensity and vigorous physical activity in two separate samples of young adults. Staging measures have focused on vigorous exercise, but current public health guidelines emphasize moderate-intensity activity. Method. For college students in the USA (n = 105) and in Australia (n = 123), SOC was assessed separately on two occasions for moderate-intensity activity and for vigorous activity. Test-retest repeatability was determined, using Cohen's kappa coefficient. Results. In both samples, the reliability scores for the moderate-intensity physical activity staging measure were lower than the scores for the vigorous exercise staging measure. Weighted kappa values for the moderate-intensity staging measure were in the fair to good range for both studies (0.50 and 0.45); for the vigorous staging measure kappa values were excellent and fair to good (0.76 and 0.72). Conclusions. There is a need to standardize and improve methods for staging moderate-intensity activity, given that such measures are used in public health interventions targeting HEPA (health-enhancing physical activity). (C) 2003 American Health Foundation and Elsevier Science (USA). All rights reserved.
Resumo:
A variabilidade natural dos solos torna complexo o conhecimento de suas propriedades na elaboração de projetos geotécnicos, sendo a determinação da resistência ao cisalhamento não drenada um parâmetro importante nas análises de estabilidade de solos moles. Os ensaios de laboratório de cone e palheta, não convencionais, os ensaios de campo de palheta e piezocone e os ensaios de compressão simples e triaxial não adensado e não drenado foram utilizados para mensurar a resistência não drenada de uma camada de argila marinha mole localizada na planície costeira central brasileira. Os ensaios de laboratório foram realizados em amostras indeformadas coletadas com amostradores de pistão estacionário em vertical próxima à realização dos ensaios de campo. O sítio foi investigado preliminarmente por sondagens de simples reconhecimento, sendo apresentado o perfil estratigráfico por meio de modelagem computacional. Foram também realizados ensaios para caracterização física (análise granulométrica, teor de umidade, limites de liquidez e plasticidade, densidade real dos grãos) e mineralógica (difração de raios X), e ensaios de adensamento para obtenção do histórico de tensões e classificação de qualidade das amostras indeformadas. Os valores de resistência não drenada obtidos pelos ensaios de laboratório foram comparados ao perfil contínuo de resistência determinado empiricamente pelo ensaio de piezocone, com fator de cone Nkt calibrado pelo ensaio de palheta de campo, apresentando boa concordância, com a variabilidade natural do solo influenciando de forma preponderante a qualidade das amostras na variação entre os resultados. Os valores de resistência obtidos pelos ensaios de laboratório de cone e palheta foram comparados entre si, apresentando boa compatibilidade. Ambos, quando comparados ao ensaio de palheta de campo, não apresentaram boa concordância. Os resultados de resistência obtidos pelos ensaios de compressão simples e triaxial apresentaram boa compatibilidade com os resultados do ensaio de laboratório de cone, o que não ocorreu com os resultados do ensaio de laboratório de palheta. Na comparação entre a resistência normalizada pela tensão de sobreadensamento obtida pelos diversos métodos e algumas correlações empíricas da literatura internacional, foi observado para as amostras de solo com índice de plasticidade superior a 60% boa concordância com as correlações de Mesri (1975) e Jamiolkowski et al (1985). Os ensaios não convencionais apresentaram boa confiabilidade, que aliado a simplicidade e agilidade de execução, justificam a difusão destes na prática da investigação geotécnica brasileira como método alternativo para complementar e dar suporte às estimativas de resistência não drenada de solos moles.
Resumo:
Wireless medical systems are comprised of four stages, namely the medical device, the data transport, the data collection and the data evaluation stages. Whereas the performance of the first stage is highly regulated, the others are not. This paper concentrates on the data transport stage and argues that it is necessary to establish standardized tests to be used by medical device manufacturers to provide comparable results concerning the communication performance of the wireless networks used to transport medical data. Besides, it suggests test parameters and procedures to be used to produce comparable communication performance results.