969 resultados para reconstruction of the anophthalmic cavity
Resumo:
Diffusion MRI is a well established imaging modality providing a powerful way to probe the structure of the white matter non-invasively. Despite its potential, the intrinsic long scan times of these sequences have hampered their use in clinical practice. For this reason, a large variety of methods have been recently proposed to shorten the acquisition times. Among them, spherical deconvolution approaches have gained a lot of interest for their ability to reliably recover the intra-voxel fiber configuration with a relatively small number of data samples. To overcome the intrinsic instabilities of deconvolution, these methods use regularization schemes generally based on the assumption that the fiber orientation distribution (FOD) to be recovered in each voxel is sparse. The well known Constrained Spherical Deconvolution (CSD) approach resorts to Tikhonov regularization, based on an ℓ(2)-norm prior, which promotes a weak version of sparsity. Also, in the last few years compressed sensing has been advocated to further accelerate the acquisitions and ℓ(1)-norm minimization is generally employed as a means to promote sparsity in the recovered FODs. In this paper, we provide evidence that the use of an ℓ(1)-norm prior to regularize this class of problems is somewhat inconsistent with the fact that the fiber compartments all sum up to unity. To overcome this ℓ(1) inconsistency while simultaneously exploiting sparsity more optimally than through an ℓ(2) prior, we reformulate the reconstruction problem as a constrained formulation between a data term and a sparsity prior consisting in an explicit bound on the ℓ(0)norm of the FOD, i.e. on the number of fibers. The method has been tested both on synthetic and real data. Experimental results show that the proposed ℓ(0) formulation significantly reduces modeling errors compared to the state-of-the-art ℓ(2) and ℓ(1) regularization approaches.
Resumo:
Introduction: Extraskeletal myxoid chondrosarcoma (EMC) is a rare soft tissue tumour with a high risk for local recurrence and metastases. While this entity is resistant to radio- or chemo-therapy, wide resection remains the treatment of choice. Case report: A 60 year old man presented to our service with a large mass in his right thigh, slowly evolving over the past 7 years. His main complaint was the volume of his thigh. Imaging showed a 23x13x14 cm tumour in the quadriceps, eroding the cortical bone and with potential contamination of the knee joint. The risk of a pathological fracture was estimated considerable. A CT-guided core-needle biopsy revealed a FNCLCC grade 2 EMC. A thoraco-abdominal CT scan showed multiple pulmonary metastases. Due to the palliative situation with a very slow disease progression, a wide extraarticular resection of the distal femur and reconstruction with a megaprosthesis were performed. Extensive skin necrosis necessitated three revision procedures for débridement and confection of a pediculated lateral gastrocnemius muscle flap. No complementary treatment was possible for the pulmonary metastases. At 18 months follow-up, he walked without crutches, was able to do his activities of daily living. He was painfree and highly satisfied with the result. During the follow-up, slow progression of the pulmonary metastases was noted, which remained asymptomatic. Conclusion: Extraskeletal myxoid chondrosarcoma is a rare soft tissue tumour, and wide excision remains the treatment of choice. Whenever possible, limb salvage should be proposed to preserve function and quality of life.
Resumo:
Rhinoxenus bulbovaginatus n. sp. is described from the nose of Salminus maxillosus (Characidae) collected in the basin of the rio Paraná, near the city of Porto Rico, state of Paraná, Brazil. The new species can be differentiated from the other three species in the genus by the morphology of the copulatory complex, vagina, and ventral anchor. The sister group relationship of the known species of Rhinoxenus was determined using techniques of Phylogenetic Systematics (Cladism). The resulting cladogram (C.I.=100%) indicates that the new species is most closely related to R. piranhus Kritsky, Boeger and Thatcher, 1988. The other two species of the genus, R. arietinus Kritsky, Boeger and Thatcher, 1988 and R. nyttus Kritsky, Boeger and Thatcher, 1988, both parasites of Anostomidae fishes, have a paraphyletic position in the cladogram, suggesting that the origin of at least one of them can not be associated to cospeciation.
Resumo:
PURPOSE: To determine whether syngeneic retinal cells injected in the vitreous cavity of the rat are able to initiate a proliferative process and whether the ocular inflammation induced in rats by lipopolysaccharide (LPS) promotes this proliferative vitreoretinopathy (PVR). METHODS: Primary cultured differentiated retinal Müller glial (RMG) and retinal pigmented epithelial (RPE) cells isolated from 8 to 12 postnatal Lewis rats were injected into the vitreous cavity of 8- to 10-week-old Lewis rats (10(5) cells/eye in 2 microlieter sterile saline), with or without the systemic injection of 150 microgram LPS to cause endotoxin-induced uveitis (EIU). Control groups received an intravitreal injection of 2 microliter saline. At 5, 15, and 28 days after cell injections, PVR was clinically quantified, and immunohistochemistry for OX42, ED1, vimentin (VIM), glial fibrillary acidic protein (GFAP), and cytokeratin was performed. RESULTS: The injection of RMG cells, alone or in combination with RPE cells, induced the preretinal proliferation of a GFAP-positive tissue, that was enhanced by the systemic injection of LPS. Indeed, when EIU was induced at the time of RMG cell injection into the vitreous cavity, the proliferation led to retinal folds and localized tractional detachments. In contrast, PVR enhanced the infiltration of inflammatory cells in the anterior segment of the eye. CONCLUSIONS: In the rat, syngeneic retinal cells of glial origin induce PVR that is enhanced by the coinduction of EIU. In return, vitreoretinal glial proliferation enhanced the intensity and duration of EIU.
Resumo:
Molecular and stable carbon isotope compositions of source-specific hydrocarbons have been used to reconstruct palaeoenvironmental conditions during deposition of the Middle Hettangian to Upper Sinemurian sediments on the northern epicontinental Tethys margin, Frick Swiss Jura. Increasing algal, cyanobacterial and phytoplanktonic (i.e., dinoflagellate) contributions associated with the C-13-enrichment of cyanobacteria derivatives (i.e., hopanes and monomethylalkanes) suggest enhanced primary productivity upsection. This is related to the C-13-enrichment of dissolved CO2 in the upper layers and the progressive increase of depth and oxygenation of the water column. In the Middle Hettangian shallow-water environments (lagoon), the occurrence of green sulfur bacteria (Chlorobiaceae) derivatives indicates that the lower part of the water column was strictly anoxic and rich in H2S. Since these bacteria require very low light intensity to grow, these euxinic conditions may be extended up to the photic zone, allowing for anaerobic photosynthesis. Light penetration depth is most likely reduced by high productivity and/or turbidity in the photic zone. In these sediments, C-13-depleted hopanoids (-39.5 parts per thousand) are most likely associated with phototrophic purple sulfur bacteria utilizing isotopically light organic carbon at the base of the aerobic zone. These purple sulfur bacteria may have consumed the H2S used by Chlorobiaceae in the deeper layers and thus, sustained the algae and cyanobacteria productivity in the upper layers. The C-13-depleted carbonate (-13.3 parts per thousand) may be partially related to the anaerobic oxidation of the organic matter during bacterial sulfate-reduction. (c) 2006 Elsevier Ltd. All rights reserved.
Resumo:
Posterior chest wall defects are frequently encountered after excision of tumors as a result of trauma or in the setting of wound dehiscence after spine surgery. Various pedicled fasciocutaneous and musculocutaneous flaps have been described for the coverage of these wounds. The advent of perforator flaps has allowed the preservation of muscle function but their bulk is limited. Musculocutaneous flaps remain widely employed. The trapezius and the latissimus dorsi (LD) flaps have been used extensively for upper and middle posterior chest wounds, respectively. Their bulk allows for obliteration of the dead space in deep wounds. The average width of the LD skin paddle is limited to 10-12 cm if closure of the donor site is expected without skin grafting. In 2001 a modification of the skin paddle design was introduced in order to allow large flaps to be raised without requiring grafts or flaps for donor site closure. This V-Y pattern allows coverage of large anterior chest defects after mastectomy. We have modified this flap to allow its use for posterior chest wall defects. We describe the flap design, its indications, and its limitations with three clinical cases. Level of Evidence V This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors at www.springer.com/00266 .
Resumo:
RATIONALE AND OBJECTIVES: Dose reduction may compromise patients because of a decrease of image quality. Therefore, the amount of dose savings in new dose-reduction techniques needs to be thoroughly assessed. To avoid repeated studies in one patient, chest computed tomography (CT) scans with different dose levels were performed in corpses comparing model-based iterative reconstruction (MBIR) as a tool to enhance image quality with current standard full-dose imaging. MATERIALS AND METHODS: Twenty-five human cadavers were scanned (CT HD750) after contrast medium injection at different, decreasing dose levels D0-D5 and respectively reconstructed with MBIR. The data at full-dose level, D0, have been additionally reconstructed with standard adaptive statistical iterative reconstruction (ASIR), which represented the full-dose baseline reference (FDBR). Two radiologists independently compared image quality (IQ) in 3-mm multiplanar reformations for soft-tissue evaluation of D0-D5 to FDBR (-2, diagnostically inferior; -1, inferior; 0, equal; +1, superior; and +2, diagnostically superior). For statistical analysis, the intraclass correlation coefficient (ICC) and the Wilcoxon test were used. RESULTS: Mean CT dose index values (mGy) were as follows: D0/FDBR = 10.1 ± 1.7, D1 = 6.2 ± 2.8, D2 = 5.7 ± 2.7, D3 = 3.5 ± 1.9, D4 = 1.8 ± 1.0, and D5 = 0.9 ± 0.5. Mean IQ ratings were as follows: D0 = +1.8 ± 0.2, D1 = +1.5 ± 0.3, D2 = +1.1 ± 0.3, D3 = +0.7 ± 0.5, D4 = +0.1 ± 0.5, and D5 = -1.2 ± 0.5. All values demonstrated a significant difference to baseline (P < .05), except mean IQ for D4 (P = .61). ICC was 0.91. CONCLUSIONS: Compared to ASIR, MBIR allowed for a significant dose reduction of 82% without impairment of IQ. This resulted in a calculated mean effective dose below 1 mSv.
Resumo:
A differentiated reconstruction of palaeolimnologic, -environmental, and -climatic conditions is presented for the Middle Miocene long-term freshwater lake (14.3 to 13.5 Ma) of the Steinheim basin, on the basis of a combined C, 0, and Sr isotope study of sympatric skeletal fossils of aquatic and terrestrial organisms from the lake sediments. The oxygen isotope composition for lake water of the Steinheim basin (delta O-18(H2O) = +2.0 +/- 0.4 parts per thousand VSMOW, n = 6) was reconstructed from measurements of delta O-18(PO4) of aquatic turtle bones. The drinking water calculated from the enamel of large mammals (proboscideans, rhinocerotids, equids, cervids, suids) has delta O-18(H2O) values (delta(OH2O)-O-18 = -5.9 +/- 1.7 parts per thousand VSMOW, n = 31) typical for Middle Miocene meteoric water of the area. This delta O-18(H2O) value corresponds to a mean annual air temperature (MAT) of 18.8 +/- 3.8 degrees C, calculated using a modem-day delta(OH2O)-O-18-MAT relation. Hence, large mammals did not use the lake water as principal drinking water. In contrast, small mammals, especially the then abundant pika Prolagus oeningensis drank from O-18-enriched water sources (delta O-18(H2O) = +2.7 +/- 2.3 parts per thousand VSMOW, n = 7), such as the lake water. Differences in Sr and 0 isotopic compositions between large and small mammal teeth indicate different home ranges and drinking behaviour and support migration of some large mammals between the Swabian Alb plateau and the nearby Molasse basin, while small mammals ingested their food and water locally. Changes in the lake level, water chemistry, and temperature were inferred using isotopic compositions of ostracod and gastropod shells from a composite lake sediment profile. Calcitic ostracod valves (Ilyocypris binocularis; delta O-18 = +1.7 +/- 1.2 parts per thousand VPDB, delta C-18 = -0.5 +/- 0.9 parts per thousand, VPDB, n = 68) and aragonitic, gastropod shells (Gyraulus spp.; delta O-18 = +2.0 +/- 13 parts per thousand VPDB, delta C-13 = -1.1 +/- 1.3 parts per thousand VPDB, n = 89) have delta O-18 and delta C-13 values similar to or even higher than those of marine, carbonates. delta C-13 values:of the biogenic carbonates parallel lake level fluctuations while delta O-18 values scatter around +2 +/- 2 parts per thousand and reflect the short term variability of meteoric water inflow vs. longer term evaporation. Sr-87/Sr-86 ratios of aragonitic Gyraulus spp. gastropod shells parallel the lake level fluctuations, reflecting variable inputs of groundwater and surface waters. Using a water delta O-18(H2O) value of +2.0 parts per thousand VSMOW, water temperatures calculated from skeletal tissue delta O-18 values of ostracods are 16.7 +/- 5.0 degrees C, gastropods 20.6 +/- 5.6 degrees C, otoliths 21.8 +/- 1.4 degrees C, and fish teeth 17.0 +/- 2.7 degrees C. The calculated MAT (similar to 19 degrees C), lake water temperatures (similar to 17 to 22 degrees C) and the O-18-enriched water compositions are indicative of warm-temperate climatic conditions, possibly with a high humidity during this period. Vegetation in the area surrounding the basin was largely of the C-3-type, as indicated by carbon isotopic compositions of tooth enamel from large mammals (delta C-13 = -11.1 +/- 1.1 parts per thousand VPDB, n = 40). (c) 2006 Elsevier B.V. All rights reserved.
Resumo:
BACKGROUND: Iterative reconstruction (IR) techniques reduce image noise in multidetector computed tomography (MDCT) imaging. They can therefore be used to reduce radiation dose while maintaining diagnostic image quality nearly constant. However, CT manufacturers offer several strength levels of IR to choose from. PURPOSE: To determine the optimal strength level of IR in low-dose MDCT of the cervical spine. MATERIAL AND METHODS: Thirty consecutive patients investigated by low-dose cervical spine MDCT were prospectively studied. Raw data were reconstructed using filtered back-projection and sinogram-affirmed IR (SAFIRE, strength levels 1 to 5) techniques. Image noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were measured at C3-C4 and C6-C7 levels. Two radiologists independently and blindly evaluated various anatomical structures (both dense and soft tissues) using a 4-point scale. They also rated the overall diagnostic image quality using a 10-point scale. RESULTS: As IR strength levels increased, image noise decreased linearly, while SNR and CNR both increased linearly at C3-C4 and C6-C7 levels (P < 0.001). For the intervertebral discs, the content of neural foramina and dural sac, and for the ligaments, subjective image quality scores increased linearly with increasing IR strength level (P ≤ 0.03). Conversely, for the soft tissues and trabecular bone, the scores decreased linearly with increasing IR strength level (P < 0.001). Finally, the overall diagnostic image quality scores increased linearly with increasing IR strength level (P < 0.001). CONCLUSION: The optimal strength level of IR in low-dose cervical spine MDCT depends on the anatomical structure to be analyzed. For the intervertebral discs and the content of neural foramina, high strength levels of IR are recommended.
Resumo:
Au cours des deux dernières décennies, la technique d'imagerie arthro-scanner a bénéficié de nombreux progrès technologiques et représente aujourd'hui une excellente alternative à l'imagerie par résonance magnétique (IRM) et / ou arthro-IRM dans l'évaluation des pathologies de la hanche. Cependant, elle reste limitée par l'exposition aux rayonnements ionisants importante. Les techniques de reconstruction itérative (IR) ont récemment été mis en oeuvre avec succès en imagerie ; la littérature montre que l'utilisation ces dernières contribue à réduire la dose d'environ 40 à 55%, comparativement aux protocoles courants utilisant la rétroprojection filtrée (FBP), en scanner de rachis. A notre connaissance, l'utilisation de techniques IR en arthro-scanner de hanche n'a pas été évaluée jusqu'à présent. Le but de notre étude était d'évaluer l'impact de la technique ASIR (GE Healthcare) sur la qualité de l'image objective et subjective en arthro-scanner de hanche, et d'évaluer son potentiel en terme de réduction de dose. Pour cela, trente sept patients examinés par arthro-scanner de hanche ont été randomisés en trois groupes : dose standard (CTDIvol = 38,4 mGy) et deux groupes de dose réduite (CTDIvol = 24,6 ou 15,4 mGy). Les images ont été reconstruites en rétroprojection filtrée (FBP) puis en appliquant différents pourcentages croissants d'ASIR (30, 50, 70 et 90%). Le bruit et le rapport contraste sur bruit (CNR) ont été mesurés. Deux radiologues spécialisés en imagerie musculo-squelettique ont évalué de manière indépendante la qualité de l'image au niveau de plusieurs structures anatomiques en utilisant une échelle de quatre grades. Ils ont également évalué les lésions labrales et du cartilage articulaire. Les résultats révèlent que le bruit augmente (p = 0,0009) et le CNR diminue (p = 0,001) de manière significative lorsque la dose diminue. A l'inverse, le bruit diminue (p = 0,0001) et le contraste sur bruit augmente (p < 0,003) de manière significative lorsque le pourcentage d'ASIR augmente ; on trouve également une augmentation significative des scores de la qualité de l'image pour le labrum, le cartilage, l'os sous-chondral, la qualité de l'image globale (au delà de ASIR 50%), ainsi que le bruit (p < 0,04), et une réduction significative pour l'os trabuculaire et les muscles (p < 0,03). Indépendamment du niveau de dose, il n'y a pas de différence significative pour la détection et la caractérisation des lésions labrales (n=24, p = 1) et des lésions cartilagineuses (n=40, p > 0,89) en fonction du pourcentage d'ASIR. Notre travail a permis de montrer que l'utilisation de plus de 50% d'ASIR permet de reduire de manière significative la dose d'irradiation reçue par le patient lors d'un arthro-scanner de hanche tout en maintenant une qualité d'image diagnostique comparable par rapport à un protocole de dose standard utilisant la rétroprojection filtrée.
Resumo:
In vivo dosimetry is a way to verify the radiation dose delivered to the patient in measuring the dose generally during the first fraction of the treatment. It is the only dose delivery control based on a measurement performed during the treatment. In today's radiotherapy practice, the dose delivered to the patient is planned using 3D dose calculation algorithms and volumetric images representing the patient. Due to the high accuracy and precision necessary in radiation treatments, national and international organisations like ICRU and AAPM recommend the use of in vivo dosimetry. It is also mandatory in some countries like France. Various in vivo dosimetry methods have been developed during the past years. These methods are point-, line-, plane- or 3D dose controls. A 3D in vivo dosimetry provides the most information about the dose delivered to the patient, with respect to ID and 2D methods. However, to our knowledge, it is generally not routinely applied to patient treatments yet. The aim of this PhD thesis was to determine whether it is possible to reconstruct the 3D delivered dose using transmitted beam measurements in the context of narrow beams. An iterative dose reconstruction method has been described and implemented. The iterative algorithm includes a simple 3D dose calculation algorithm based on the convolution/superposition principle. The methodology was applied to narrow beams produced by a conventional 6 MV linac. The transmitted dose was measured using an array of ion chambers, as to simulate the linear nature of a tomotherapy detector. We showed that the iterative algorithm converges quickly and reconstructs the dose within a good agreement (at least 3% / 3 mm locally), which is inside the 5% recommended by the ICRU. Moreover it was demonstrated on phantom measurements that the proposed method allows us detecting some set-up errors and interfraction geometry modifications. We also have discussed the limitations of the 3D dose reconstruction for dose delivery error detection. Afterwards, stability tests of the tomotherapy MVCT built-in onboard detector was performed in order to evaluate if such a detector is suitable for 3D in-vivo dosimetry. The detector showed stability on short and long terms comparable to other imaging devices as the EPIDs, also used for in vivo dosimetry. Subsequently, a methodology for the dose reconstruction using the tomotherapy MVCT detector is proposed in the context of static irradiations. This manuscript is composed of two articles and a script providing further information related to this work. In the latter, the first chapter introduces the state-of-the-art of in vivo dosimetry and adaptive radiotherapy, and explains why we are interested in performing 3D dose reconstructions. In chapter 2 a dose calculation algorithm implemented for this work is reviewed with a detailed description of the physical parameters needed for calculating 3D absorbed dose distributions. The tomotherapy MVCT detector used for transit measurements and its characteristics are described in chapter 3. Chapter 4 contains a first article entitled '3D dose reconstruction for narrow beams using ion chamber array measurements', which describes the dose reconstruction method and presents tests of the methodology on phantoms irradiated with 6 MV narrow photon beams. Chapter 5 contains a second article 'Stability of the Helical TomoTherapy HiArt II detector for treatment beam irradiations. A dose reconstruction process specific to the use of the tomotherapy MVCT detector is presented in chapter 6. A discussion and perspectives of the PhD thesis are presented in chapter 7, followed by a conclusion in chapter 8. The tomotherapy treatment device is described in appendix 1 and an overview of 3D conformai- and intensity modulated radiotherapy is presented in appendix 2. - La dosimétrie in vivo est une technique utilisée pour vérifier la dose délivrée au patient en faisant une mesure, généralement pendant la première séance du traitement. Il s'agit de la seule technique de contrôle de la dose délivrée basée sur une mesure réalisée durant l'irradiation du patient. La dose au patient est calculée au moyen d'algorithmes 3D utilisant des images volumétriques du patient. En raison de la haute précision nécessaire lors des traitements de radiothérapie, des organismes nationaux et internationaux tels que l'ICRU et l'AAPM recommandent l'utilisation de la dosimétrie in vivo, qui est devenue obligatoire dans certains pays dont la France. Diverses méthodes de dosimétrie in vivo existent. Elles peuvent être classées en dosimétrie ponctuelle, planaire ou tridimensionnelle. La dosimétrie 3D est celle qui fournit le plus d'information sur la dose délivrée. Cependant, à notre connaissance, elle n'est généralement pas appliquée dans la routine clinique. Le but de cette recherche était de déterminer s'il est possible de reconstruire la dose 3D délivrée en se basant sur des mesures de la dose transmise, dans le contexte des faisceaux étroits. Une méthode itérative de reconstruction de la dose a été décrite et implémentée. L'algorithme itératif contient un algorithme simple basé sur le principe de convolution/superposition pour le calcul de la dose. La dose transmise a été mesurée à l'aide d'une série de chambres à ionisations alignées afin de simuler la nature linéaire du détecteur de la tomothérapie. Nous avons montré que l'algorithme itératif converge rapidement et qu'il permet de reconstruire la dose délivrée avec une bonne précision (au moins 3 % localement / 3 mm). De plus, nous avons démontré que cette méthode permet de détecter certaines erreurs de positionnement du patient, ainsi que des modifications géométriques qui peuvent subvenir entre les séances de traitement. Nous avons discuté les limites de cette méthode pour la détection de certaines erreurs d'irradiation. Par la suite, des tests de stabilité du détecteur MVCT intégré à la tomothérapie ont été effectués, dans le but de déterminer si ce dernier peut être utilisé pour la dosimétrie in vivo. Ce détecteur a démontré une stabilité à court et à long terme comparable à d'autres détecteurs tels que les EPIDs également utilisés pour l'imagerie et la dosimétrie in vivo. Pour finir, une adaptation de la méthode de reconstruction de la dose a été proposée afin de pouvoir l'implémenter sur une installation de tomothérapie. Ce manuscrit est composé de deux articles et d'un script contenant des informations supplémentaires sur ce travail. Dans ce dernier, le premier chapitre introduit l'état de l'art de la dosimétrie in vivo et de la radiothérapie adaptative, et explique pourquoi nous nous intéressons à la reconstruction 3D de la dose délivrée. Dans le chapitre 2, l'algorithme 3D de calcul de dose implémenté pour ce travail est décrit, ainsi que les paramètres physiques principaux nécessaires pour le calcul de dose. Les caractéristiques du détecteur MVCT de la tomothérapie utilisé pour les mesures de transit sont décrites dans le chapitre 3. Le chapitre 4 contient un premier article intitulé '3D dose reconstruction for narrow beams using ion chamber array measurements', qui décrit la méthode de reconstruction et présente des tests de la méthodologie sur des fantômes irradiés avec des faisceaux étroits. Le chapitre 5 contient un second article intitulé 'Stability of the Helical TomoTherapy HiArt II detector for treatment beam irradiations'. Un procédé de reconstruction de la dose spécifique pour l'utilisation du détecteur MVCT de la tomothérapie est présenté au chapitre 6. Une discussion et les perspectives de la thèse de doctorat sont présentées au chapitre 7, suivies par une conclusion au chapitre 8. Le concept de la tomothérapie est exposé dans l'annexe 1. Pour finir, la radiothérapie «informationnelle 3D et la radiothérapie par modulation d'intensité sont présentées dans l'annexe 2.