948 resultados para passive safety systems


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The Food and Drug Administration (FDA) is responsible for risk assessment and risk management in the post-market surveillance of the U.S. medical device industry. One of the FDA regulatory mechanisms, the Medical Device Reporting System (MDR) is an adverse event reporting system intended to provide the FDA with advance warning of device problems. It includes voluntary reporting for individuals, and mandatory reporting for device manufacturers. ^ In a study of alleged breast implant safety problems, this research examines the organizational processes by which the FDA gathers data on adverse events and uses adverse event reporting systems to assess and manage risk. The research reviews the literature on problem recognition, risk perception, and organizational learning to understand the influence highly publicized events may have on adverse event reporting. Understanding the influence of an environmental factor, such as publicity, on adverse event reporting can provide insight into the question of whether the FDA's adverse event reporting system operates as an early warning system for medical device problems. ^ The research focuses on two main questions. The first question addresses the relationship between publicity and the voluntary and mandatory reporting of adverse events. The second question examines whether government agencies make use of these adverse event reports. ^ Using quantitative and qualitative methods, a longitudinal study was conducted of the number and content of adverse event reports regarding breast implants filed with the FDA's medical device reporting system during 1985–1991. To assess variation in publicity over time, the print media were analyzed to identify articles related to breast implant failures. ^ The exploratory findings suggest that an increase in media activity is related to an increase in voluntary reporting, especially following periods of intense media coverage of the FDA. However, a similar relationship was not found between media activity and manufacturers' mandatory adverse event reporting. A review of government committee and agency reports on the FDA published during 1976–1996 produced little evidence to suggest that publicity or MDR information contributed to problem recognition, agenda setting, or the formulation of policy recommendations. ^ The research findings suggest that the reporting of breast implant problems to FDA may reflect the perceptions and concerns of the reporting groups, a barometer of the volume and content of media attention. ^

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Patient safety is a major concern in health care systems worldwide. Patients with serious conditions, multimorbidity, and with intense and fragmented health care utilization, like end-stage renal disease (ESRD) patients, are at increased risk for suffering adverse events. In this chapter, the fundamental terms and concepts of patient safety are introduced. Essential epidemiological data relating to the frequency of adverse events and medical errors are provided. The chapter reports important safety threats for ESRD patients and describes examples of key innovations which contribute to patient safety. Recommendations and risk reduction strategies to improve care of ESRD patients are presented. © 2015 S. Karger AG, Basel.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Time-based indoor localization has been investigated for several years but the accuracy of existing solutions is limited by several factors, e.g., imperfect synchronization, signal bandwidth and indoor environment. In this paper, we compare two time-based localization algorithms for narrow-band signals, i.e., multilateration and fingerprinting. First, we develop a new Linear Least Square (LLS) algorithm for Differential Time Difference Of Arrival (DTDOA). Second, fingerprinting is among the most successful approaches used for indoor localization and typically relies on the collection of measurements on signal strength over the area of interest. We propose an alternative by constructing fingerprints of fine-grained time information of the radio signal. We offer comprehensive analytical discussions on the feasibility of the approaches, which are backed up by evaluations in a software defined radio based IEEE 802.15.4 testbed. Our work contributes to research on localization with narrow-band signals. The results show that our proposed DTDOA-based LLS algorithm obviously improves the localization accuracy compared to traditional TDOA-based LLS algorithm but the accuracy is still limited because of the complex indoor environment. Furthermore, we show that time-based fingerprinting is a promising alternative to power-based fingerprinting.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this work, we provide a passive location monitoring system for IEEE 802.15.4 signal emitters. The system adopts software defined radio techniques to passively overhear IEEE 802.15.4 packets and to extract power information from baseband signals. In our system, we provide a new model based on the nonlinear regression for ranging. After obtaining distance information, a Weighted Centroid (WC) algorithm is adopted to locate users. In WC, each weight is inversely proportional to the nth power of propagation distance, and the degree n is obtained from some initial measurements. We evaluate our system in a 16m-18m area with complex indoor propagation conditions. We are able to achieve a median error of 2:1m with only 4 anchor nodes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In Germany's compensatory mixed electoral system, alternative electoral routes lead into parliament. We study the relationship between candidates' electoral situations across both tiers and policy representation, fully accounting for candidate, party and district preferences in a multi-actor constellation and the exact electoral incentives for candidates to represent either the party or the district. The results (2009 Bundestag election data) yield evidence of an interactive effect of closeness of the district race and list safety on candidates' positioning between their party and constituency.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE Precise temperature measurements in the magnetic field are indispensable for MR safety studies and for temperature calibration during MR-guided thermotherapy. In this work, the interference of two commonly used fiber-optical temperature measurement systems with the static magnetic field B0 was determined. METHODS Two fiber-optical temperature measurement systems, a GaAs-semiconductor and a phosphorescent phosphor ceramic, were compared for temperature measurements in B0 . The probes and a glass thermometer for reference were placed in an MR-compatible tube phantom within a water bath. Temperature measurements were carried out at three different MR systems covering static magnetic fields up to B0  = 9.4T, and water temperatures were changed between 25°C and 65°C. RESULTS The GaAs-probe significantly underestimated absolute temperatures by an amount related to the square of B0 . A maximum difference of ΔT = -4.6°C was seen at 9.4T. No systematic temperature difference was found with the phosphor ceramic probe. For both systems, the measurements were not dependent on the orientation of the sensor to B0 . CONCLUSION Temperature measurements with the phosphor ceramic probe are immune to magnetic fields up to 9.4T, whereas the GaAs-probes either require a recalibration inside the MR system or a correction based on the square of B0 . Magn Reson Med, 2014. © 2014 Wiley Periodicals, Inc.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Indoor localization systems become more interesting for researchers because of the attractiveness of business cases in various application fields. A WiFi-based passive localization system can provide user location information to third-party providers of positioning services. However, indoor localization techniques are prone to multipath and Non-Line Of Sight (NLOS) propagation, which lead to significant performance degradation. To overcome these problems, we provide a passive localization system for WiFi targets with several improved algorithms for localization. Through Software Defined Radio (SDR) techniques, we extract Channel Impulse Response (CIR) information at the physical layer. CIR is later adopted to mitigate the multipath fading problem. We propose to use a Nonlinear Regression (NLR) method to relate the filtered power information to propagation distances, which significantly improves the ranging accuracy compared to the commonly used log-distance path loss model. To mitigate the influence of ranging errors, a new trilateration algorithm is designed as well by combining Weighted Centroid and Constrained Weighted Least Square (WC-CWLS) algorithms. Experiment results show that our algorithm is robust against ranging errors and outperforms the linear least square algorithm and weighted centroid algorithm.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Engineered nanomaterials have unique and novel properties enabling wide-ranging new applications in nearly all fields of research. As these new properties have raised concerns about potential adverse effects for the environment and human health, extensive efforts are underway to define reliable, cost- and time-effective, as well as mechanistic-based testing strategies to replace the current method of animal testing, which is still the most prevalent model used for the risk assessment of chemicals. Current approaches for nanomaterials follow this line. The aim of this review is to explore and qualify the relevance of new in vitro and ex vivo models in (nano)material safety assessment, a crucial prerequisite for translation into applications.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND National safety alert systems publish relevant information to improve patient safety in hospitals. However, the information has to be transformed into local action to have an effect on patient safety. We studied three research questions: How do Swiss healthcare quality and risk managers (qm/rm(1)) see their own role in learning from safety alerts issued by the Swiss national voluntary reporting and analysis system? What are their attitudes towards and evaluations of the alerts, and which types of improvement actions were fostered by the safety alerts? METHODS A survey was developed and applied to Swiss healthcare risk and quality managers, with a response rate of 39 % (n=116). Descriptive statistics are presented. RESULTS The qm/rm disseminate and communicate with a broad variety of professional groups about the alerts. While most respondents felt that they should know the alerts and their contents, only a part of them felt responsible for driving organizational change based on the recommendations. However, most respondents used safety alerts to back up their own patient safety goals. The alerts were evaluated positively on various dimensions such as usefulness and were considered as standards of good practice by the majority of the respondents. A range of organizational responses was applied, with disseminating information being the most common. An active role is related to using safety alerts for backing up own patient safety goals. CONCLUSIONS To support an active role of qm/rm in their hospital's learning from safety alerts, appropriate organizational structures should be developed. Furthermore, they could be given special information or training to act as an information hub on the issues discussed in the alerts.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Indoor positioning has attracted considerable attention for decades due to the increasing demands for location based services. In the past years, although numerous methods have been proposed for indoor positioning, it is still challenging to find a convincing solution that combines high positioning accuracy and ease of deployment. Radio-based indoor positioning has emerged as a dominant method due to its ubiquitousness, especially for WiFi. RSSI (Received Signal Strength Indicator) has been investigated in the area of indoor positioning for decades. However, it is prone to multipath propagation and hence fingerprinting has become the most commonly used method for indoor positioning using RSSI. The drawback of fingerprinting is that it requires intensive labour efforts to calibrate the radio map prior to experiments, which makes the deployment of the positioning system very time consuming. Using time information as another way for radio-based indoor positioning is challenged by time synchronization among anchor nodes and timestamp accuracy. Besides radio-based positioning methods, intensive research has been conducted to make use of inertial sensors for indoor tracking due to the fast developments of smartphones. However, these methods are normally prone to accumulative errors and might not be available for some applications, such as passive positioning. This thesis focuses on network-based indoor positioning and tracking systems, mainly for passive positioning, which does not require the participation of targets in the positioning process. To achieve high positioning accuracy, we work on some information of radio signals from physical-layer processing, such as timestamps and channel information. The contributions in this thesis can be divided into two parts: time-based positioning and channel information based positioning. First, for time-based indoor positioning (especially for narrow-band signals), we address challenges for compensating synchronization offsets among anchor nodes, designing timestamps with high resolution, and developing accurate positioning methods. Second, we work on range-based positioning methods with channel information to passively locate and track WiFi targets. Targeting less efforts for deployment, we work on range-based methods, which require much less calibration efforts than fingerprinting. By designing some novel enhanced methods for both ranging and positioning (including trilateration for stationary targets and particle filter for mobile targets), we are able to locate WiFi targets with high accuracy solely relying on radio signals and our proposed enhanced particle filter significantly outperforms the other commonly used range-based positioning algorithms, e.g., a traditional particle filter, extended Kalman filter and trilateration algorithms. In addition to using radio signals for passive positioning, we propose a second enhanced particle filter for active positioning to fuse inertial sensor and channel information to track indoor targets, which achieves higher tracking accuracy than tracking methods solely relying on either radio signals or inertial sensors.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Material Safety Data Sheets (MSDSs) are an integral component of occupational hazard communication systems. These documents are used to disseminate hazard information to workers on chemical substances. The primary purpose of this study was to investigate the comprehensibility of MSDSs by workers at an international level. ^ A total of 117 employees of a multi-national petrochemical company participated; thirty-nine (39) each in the United States, Canada and the United Kingdom. Overall participation rate of those approached to participate was 82%. These countries were selected as they each utilize one of the three major existing hazard communication systems for fixed workplaces. The systems are comprised of the Occupational Safety and Health Administration's Hazard Communication Standard in the United States, the Workplace Hazardous Materials Information System (WHMIS) in Canada, and the compilation of several European Union directives addressing classification, labeling of substances and preparations, and MSDSs in Europe. ^ A pretest posttest randomized study design was used, with the posttest being comparable to an open book test. The results of this research indicated that only about two-thirds of the information on the MSDSs was comprehended by the workers with a significant difference identified among study participants based on country comparisons. This data was fairly consistent with the results of previous MSDS comprehensibility studies conducted in the United States. There was no significant difference in the comprehension level among study participants when taking into account the international hazard communication standard that the MSDS complied with. Marginally, age, education level and experience level did not have a significant impact on the comprehension level. ^ Participants did find MSDSs to be satisfactory in providing the information needed to protect them regardless of their views on the readability and formatting of MSDSs. The health-related information was the least comprehended as less than half of it was comprehended on the basis of the responses. The findings from this research suggest that there is much work needed yet to make MSDSs more comprehensible on a global basis, particularly regarding health-related information. ^

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction: The Texas Occupational Safety & Health Surveillance System (TOSHSS) was created to collect, analyze and interpret occupational injury and illness data in order to decrease the impact of occupational injuries within the state of Texas. This process evaluation was performed midway through the 4-year grant to assess the efficiency and effectiveness of the surveillance system’s planning and implementation activities1. ^ Methods: Two evaluation guidelines published by the Centers for Disease Control and Prevention (CDC) were used as the theoretical models for this process evaluation. The Framework for Program Evaluation in Public Health was used to examine the planning and design of TOSHSS using logic models. The Framework for Evaluating Public Health Surveillance Systems was used to examine the implementation of approximately 60 surveillance activities, including uses of the data obtained from the surveillance system. ^ Results/Discussion: TOSHSS planning activities omitted the creation of a scientific advisory committee and specific activities designed to maintain contacts with stakeholders; and proposed activities should be reassessed and aligned with ongoing performance measurement criteria, including the role of collaborators in helping the surveillance system achieve each proposed activity. TOSHSS implementation activities are substantially meeting expectations and received an overall score of 61% for all activities being performed. TOSHSS is considered a surveillance system that is simple, flexible, acceptable, fairly stable, timely, moderately useful, with good data quality and a PVP of 86%. ^ Conclusions: Through the third year of TOSHSS implementation, the surveillance system is has made a considerable contribution to the collection of occupational injury and illness information within the state of Texas. Implementation of the nine recommendations provided under this process evaluation is expected to increase the overall usefulness of the surveillance system and assist TDSHS in reducing occupational fatalities, injuries, and diseases within the state of Texas. ^ 1 Disclaimer: The Texas Occupational Safety and Health Surveillance System is supported by Grant/Cooperative Agreement Number (U60 OH008473-01A1). The content of the current evaluation are solely the responsibility of the authors and do not necessarily represent the official views of the Centers for Disease Control and Prevention, National Institute for Occupational Safety and Health.^

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Increasing attention has been given to the problem of medical errors over the past decade. Included within that focused attention has been a strong interest in reducing the occurrence of healthcare-associated infections (HAIs). Acting concurrently with federal initiatives, the majority of U.S. states have statutorily required reporting and public disclosure of HAI data. Although the occurrence of these state statutory enactments and other state initiatives represent a recognition of the strong concern pertaining to HAIs, vast differences in each state’s HAI reporting and public disclosure requirements creates a varied and unequal response to what has become a national problem.^ The purpose of this research was to explore the variations in state HAI legal requirements and other state mandates. State actions, including statutory enactments, regulations, and other initiatives related to state reporting and public disclosure mechanisms were compared, discussed, and analyzed in an effort to illustrate the impact of the lack of uniformity as a public health concern.^ The HAI statutes, administrative requirements, and other mandates of each state and two U.S. territories were reviewed to answer the following seven research questions: How far has the state progressed in its HAI initiative? If the state has a HAI reporting requirement, is it mandatory or voluntary? What healthcare entities are subject to the reporting requirements? What data collection system is utilized? What measures are required to be reported? What is the public disclosure mechanism? How is the underlying reported information protected from public disclosure or other legal release?^ Secondary publicly available data, including state statutes, administrative rules, and other initiatives, were utilized to examine the current HAI-related legislative and administrative activity of the study subjects. The information was reviewed and analyzed to determine variations in HAI reporting and public disclosure laws. Particular attention was given to the seven key research questions.^ The research revealed that considerable progress has been achieved in state HAI initiatives since 2004. Despite this progress, however, when reviewing the state laws and HAI programs comparatively, considerable variations were found to exist with regards to the type of reporting requirements, healthcare facilities subject to the reporting laws, data collection systems utilized, reportable measures, public disclosure requirements, and confidentiality and privilege provisions. The wide variations in state statutes, administrative rules, and other agency directives create a fragmented and inconsistent approach to addressing the nationwide occurrence of HAIs in the U.S. healthcare system. ^

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Feline immunodeficiency virus (FIV)-based gene transfer systems are being seriously considered for human gene therapy as an alternative to vectors based on primate lentiviruses, a genetically complex group of retroviruses capable of infecting non-dividing cells. The greater phylogenetic distance between the feline and primate lentiviruses is thought to reduce chances of the generation of recombinant viruses. However, safety of FIV-based vector systems has not been tested experimentally. Since primate lentiviruses such as human and simian immunodeficiency viruses (HIV/SIV) can cross-package each other's genomes, we tested this trait with respect to FIV. Unexpectedly, both feline and primate lentiviruses were reciprocally able to both cross-package and propagate each other's RNA genomes. This was largely due to the recognition of viral packaging signals by the heterologous proteins. However, a simple retrovirus such as Mason-Pfizer monkey virus (MPMV) was unable to package FIV RNA. Interestingly, FIV could package MPMV RNA, but not propagate it for further steps of replication. These findings suggest that upon co-infection of the same host, cross-packaging may allow distinct retroviruses to generate chimeric variants with unknown pathogenic potential. ^ In order to understand the packaging determinants in FIV, we conducted a detailed mutational analysis of the region thought to contain FIV packaging signal. We show that the first 90–120 nt of the 5′ untranslated region (UTR) and the first 90 nt of gag were simultaneously required for efficient FIV RNA packaging. These results suggest that the primary FIV packaging signal is multipartite and discontinuous, composed of two core elements separated by 150 nt of the 5 ′UTR. ^ The above studies are being used towards the development of safer FIV-based self-inactivating (SIN) vectors. These vectors are being designed to eliminate the ability of FIV transfer vector RNAs to be mobilized by primate lentiviral proteins that may be present in the target cells. Preliminary test of the first generation of these vectors has revealed that they are incapable of being propagated by feline proteins. The inability of FIV transfer vectors to express packageable vector RNA after integration should greatly increase the safety of FIV vectors for human gene therapy. ^

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Globalization as progress of economic development has increased population socioeconomical vulnerability when unequal wealth distribution within economic development process constitutes the main rule, with widening the gap between rich and poors by environmental pricing. Econological vulnerability is therefore increasing too, as dangerous substance and techniques should produce polluted effluents and industrial or climatic risk increasing (Woloszyn, Quenault, Faburel, 2012). To illustrate and model this process, we propose to introduce an analogical induction-model to describe both vulnerability situations and associated resilience procedures. At this aim, we first develop a well-known late 80?s model of socio-economic crack-up, known as 'Silent Weapons for Quiet Wars', which presents economics as a social extension of natural energy systems. This last, also named 'E-model', is constituted by three passive components, potential energy, kinetic energy, and energy dissipation, thus allowing economical data to be treated as a thermodynamical system. To extend this model to social and ecological sustainability pillars, we propose to built an extended E(Economic)-S(Social)-O(Organic) model, based on the three previous components, as an open model considering feedbacks as evolution sources. An applicative illustration of this model will then be described, through this summer's american severe drought event analysis