385 resultados para neuromyelitis optica
Resumo:
1D and 2D patterning of uncharged micro- and nanoparticles via dielectrophoretic forces on photovoltaic z-cut Fe:LiNbO3 have been investigated for the first time. The technique has been successfully applied with dielectric micro-particles of CaCO3 (diameter d = 1-3 μm) and metal nanoparticles of Al (d = 70 nm). At difference with previous experiments in x- and y-cut, the obtained patterns locally reproduce the light distribution with high fidelity. A simple model is provided to analyse the trapping process. The results show the remarkably good capabilities of this geometry for high quality 2D light-induced dielectrophoretic patterning overcoming the important limitations presented by previous configurations.
Resumo:
En el estudio de la propagación transversal de una radiación luminosa a través de un capilar con cristal líquido nemático, y cuyas moléculas se encuentran orientadas homeotrópicamente con respecto a las paredes internas de dicho capilar es necesario conocer de forma exacta la distribución espacial del director de cada una de las moléculas contenidas en el mismo. Esta distribución ha sido obtenida de forma empírica por Scudieri interpretando los resultados mediante la suposición de "lente delgada". Experimentalmente, mediante técnicas interferométricas, se obtienen dos grupos de franjas correspondiendo uno al índice de refraccción ordinario y siendo el otro función del ordinario y del extraordinario. El análisis de estas franjas es de una gran importancia a la hora de aplicar estructuras como la presente en Optica Integrada, ya que de ellas se puede inferir cuál es la respuesta de las moléculas de cristal líquido frente a campos externos, conocidos los valores del índice de refracción.
Resumo:
Estos apuntes de Procesado Cuántico de la Información, escritos por Francisco José Rodríguez Fortuño, están basados en las clases y el material aportado por el Prof. Miguel Angel Muriel Fernández.
Resumo:
The aim of this work is to provide an analytical method based on experimental measurements in order to obtain the prismatic film deformation for different curvatures of Hollow Cylindrical Prismatic Light Guides (CPLG). To conform cylindrical guides is necessary bend the film to guide the light, changes induced by curving the film give rise to deformation shifts. Light losses affected by deformation has been experimentally evaluated and numerically analyzed. The effect of deformation in prism angle is specially increased for CPLG of curvatures higher than 20 m-1. An experimental method for accurate transmittance measurements related to bending is presented.
Resumo:
In this contribution the line flow method is applied to an optimized secondary optics in a photovoltaic concentration system where the primary optics is already defined and characterized. This method is a particular application of photic field theory. This method uses the parameterization of a given primary optics, including actual tolerances of the manufacturing process. The design of the secondary optics is constrained by the selection of primary optics and maximizes the concentration at a previously specified collection area. The geometry of the secondary element is calculated by using a virtual source, which sends light in a first concentration step. This allows us to calculate the line flow for this specific case. This concept allows designing more compact and efficient secondary optics of photovoltaic systems.
Resumo:
A new method for fitting a series of Zernike polynomials to point clouds defined over connected domains of arbitrary shape defined within the unit circle is presented in this work. The method is based on the application of machine learning fitting techniques by constructing an extended training set in order to ensure the smooth variation of local curvature over the whole domain. Therefore this technique is best suited for fitting points corresponding to ophthalmic lenses surfaces, particularly progressive power ones, in non-regular domains. We have tested our method by fitting numerical and real surfaces reaching an accuracy of 1 micron in elevation and 0.1 D in local curvature in agreement with the customary tolerances in the ophthalmic manufacturing industry.
Resumo:
Fresnel lenses and other faceted or micro-optic devices are increasingly used in multiple applications like solar light concentrators and illumination devices, just to name some representative. However, it seems to be a certain lack of adequate techniques for the assessment of the performance of final fabricated devices. As applications are more exigent this characterization is a must. We provide a technique to characterize the performance of Fresnel lenses, as light collection devices. The basis for the method is a configuration where a camera images the Fresnel lens aperture. The entrance pupil of the camera is situated at the focal spot or the conjugate of a simulated solar source. In this manner, detailed maps of the performance of different Fresnel lenses are obtained for different acceptance angles.
Resumo:
Principal component analysis phase shifting (PCA) is a useful tool for fringe pattern demodulation in phase shifting interferometry. The PCA has no restrictions on background intensity or fringe modulation, and it is a self-calibrating phase sampling algorithm (PSA). Moreover, the technique is well suited for analyzing arbitrary sets of phase-shifted interferograms due to its low computational cost. In this work, we have adapted the standard phase shifting algorithm based on the PCA to the particular case of photoelastic fringe patterns. Compared with conventional PSAs used in photoelasticity, the PCA method does not need calibrated phase steps and, given that it can deal with an arbitrary number of images, it presents good noise rejection properties, even for complicated cases such as low order isochromatic photoelastic patterns. © 2016 Optical Society of America.
Resumo:
One of the main technical difficulties in the fabrication of optical antennas working as light detectors is the proper design and manufacture of auxiliary elements as load lines and signal extraction structures. These elements need to be quite small to reach the location of the antennas and should have a minimal effect on the response of the device. Unfortunately this is not an easy task and signal extraction lines resonate along with the antenna producing a complex signal that usually masks the one given by the antenna. In order to decouple the resonance from the transduction we present in this contribution a parametric analysis of the response of a bolometric stripe that is surrounded by resonant dipoles with different geometries and orientations. We have checked that these elements should provide a signal proportional to the polarization state of the incoming light.
Resumo:
Fractal antennas have been proposed to improve the bandwidth of resonant structures and optical antennas. Their multiband characteristics are of interest in radiofrequency and microwave technologies. In this contribution we link the geometry of the current paths built-in the fractal antenna with the spectral response. We have seen that the actual currents owing through the structure are not limited to the portion of the fractal that should be geometrically linked with the signal. This fact strongly depends on the design of the fractal and how the different scales are arranged within the antenna. Some ideas involving materials that could actively respond to the incoming radiation could be of help to spectrally select the response of the multiband design.
Resumo:
The practical application of optical antennas in detection devices strongly depends on its ability to produce an acceptable signal-to-noise ratio for the given task. It is known that, due to the intrinsic problems arising from its sub-wavelength dimensions, optical antennas produce very small signals. The quality of these signals depends on the involved transduction mechanism. The contribution of different types of noise should be adapted to the transducer and to the signal extraction regime. Once noise is evaluated and measured, the specific detectivity, D*, becomes the parameter of interest when comparing the performance of antenna coupled devices with other detectors. However, this parameter involves some magnitudes that can be defined in several ways for optical antennas. In this contribution we are interested in the evaluation and comparison of D_ values for several bolometric optical antennas working in the infrared and involving two materials. At the same time, some material and geometrical parameters involved in the definition of noise and detectivity will be discussed to analyze the suitability of D_ to properly account for the performance of optical antennas.
Resumo:
Nonclassicality cannot be a single-observable property, since the statistics of any quantum observable is compatible with classical physics. We develop a general procedure to reveal nonclassical behavior of light states from the joint statistics arising in the practical measurement of multiple observables. Beside embracing previous approaches, this protocol can disclose nonclassical features for standard examples of classical-like behavior, such as SU(2) and Glauber coherent states. When combined with other criteria, this would imply that every light state is nonclassical.
Resumo:
PURPOSE: To compare disk halo size in response to a glare source in eyes with an aspheric apodized diffractive multifocal intraocular lens (IOL) or aspheric monofocal IOL. SETTING: Rementeria Ophthalmological Clinic, Madrid, Spain. DESIGN: Prospective randomized masked study. METHOD: Halo radius was measured using a vision monitor (MonCv3) with low-luminance optotypes in eyes that had cataract surgery and bilateral implantion of an Acrysof Restor SN6AD1 multifocal IOL or Acrysof IQ monofocal IOL 6 to 9 months previously. The visual angle subtended by the disk halo radius was calculated in minutes of arc (arcmin). Patient complaints of halo disturbances were recorded. Monocular uncorrected distance visual acutity (UDVA) and corrected distance visual acuity (CDVA) were measured using high-contrast (96%) and low-contrast (10%) logMAR letter charts. RESULTS: The study comprised 39 eyes of 39 subjects (aged 70 to 80 years); 21 eyes had a multifocal IOL and 18 eyes a monofocal IOL. The mean halo radius was 35 arcmin larger in the multifocal IOL group than the monofocal group (P<.05). Greater halo effects were reported in the multifocal IOL group (P<.05). The mean monocular high-contrast UDVA and low-contrast UDVA did not vary significantly between groups, whereas the mean monocular high-contrast CDVA and low-contrast CDVA were significantly worse at 0.12 logMAR and 0.13 logMAR in the multifocal than in the monofocal IOL group, respectively (P <.01). A significant positive correlation was detected by multiple linear regression between the halo radius and low-contrast UDVA in the multifocal IOL group (r = 0.72, P<.001). CONCLUSIONS: The diffractive multifocal IOL gave rise to a larger disk halo size, which was correlated with a worse low-contrast UDVA.
Resumo:
Seebeck nanoantennas, which are based on the thermoelectric effect, have been proposed for electromagnetic energy harvesting and infrared detection. The responsivity and frequency dependence of three types of Seebeck nanoantennas is obtained by electromagnetic simulation for different materials. Results show that the square spiral antenna has the widest bandwidth and the highest induced current of the three analyzed geometries. However, the geometry that presented the highest temperature gradient was the bowtie antenna, which favors the thermoelectric effect in a Seebeck nanoantenna. The results also show that these types of devices can present a voltage responsivity as high as 36 μV/W36 μV/W for titanium–nickel dipoles resonant at far-infrared wavelengths.
Resumo:
Abstract. Speckle is being used as a characterization tool for the analysis of the dynamics of slow-varying phenomena occurring in biological and industrial samples at the surface or near-surface regions. The retrieved data take the form of a sequence of speckle images. These images contain information about the inner dynamics of the biological or physical process taking place in the sample. Principal component analysis (PCA) is able to split the original data set into a collection of classes. These classes are related to processes showing different dynamics. In addition, statistical descriptors of speckle images are used to retrieve information on the characteristics of the sample. These statistical descriptors can be calculated in almost real time and provide a fast monitoring of the sample. On the other hand, PCA requires a longer computation time, but the results contain more information related to spatial–temporal patterns associated to the process under analysis. This contribution merges both descriptions and uses PCA as a preprocessing tool to obtain a collection of filtered images, where statistical descriptors are evaluated on each of them. The method applies to slow-varying biological and industrial processes.