918 resultados para low temperature plasma


Relevância:

90.00% 90.00%

Publicador:

Resumo:

Oxidation of amorphous silicon (a-Si) nanoparticles grown by plasma-enhanced chemical vapor deposition were investigated. Their hydrogen content has a great influence on the oxidation rate at low temperature. When the mass gain is recorded during a heating ramp in dry air, an oxidation process at low temperature is identified with an onset around 250°C. This temperature onset is similar to that of hydrogen desorption. It is shown that the oxygen uptake during this process almost equals the number of hydrogen atoms present in the nanoparticles. To explain this correlation, we propose that oxidation at low temperature is triggered by the process of hydrogen desorption

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The jaboticaba tree (Myrciaria spp.) is originated from the center-south of Brazil and presents different types. It's a medium size tree, with tendency to form a crown with great number of branches. A characteristic considered as limitant for the commercial crop is the great juvenility, advicing producing good rootstocks of seedlings and graft wanted varieties, and other vegetative processes. With the purpose of evaluating the effect of temperature on germination of three clones of jaboticaba tree, was carried out a laboratorial research. It was observed influence of the temperature on germination. The highest percentage of germination was obtained at low temperature (15ºC and 20ºC). When it was used the temperature of 35ºC, two clones had only 8% of germination, while the other one was verified 35%. These values show the possibility of the ocurrence of variability among the clones of jaboticaba tree.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Distinct molecular mechanisms integrate changes in ambient temperature into the genetic pathways that govern flowering time in Arabidopsis thaliana. Temperature-dependent eviction of the histone variant H2A.Z from nucleosomes has been suggested to facilitate the expression of FT by PIF4 at elevated ambient temperatures. Here we show that, in addition to PIF4, PIF3 and PIF5, but not PIF1 and PIF6, can promote flowering when expressed specifically in phloem companion cells (PCC), where they can induce FT and its close paralog, TSF. However, despite their strong potential to promote flowering, genetic analyses suggest that the PIF genes seem to have only a minor role in adjusting flowering in response to photoperiod or high ambient temperature. In addition, loss of PIF function only partially suppressed the early flowering phenotype and FT expression of the arp6 mutant, which is defective in H2A.Z deposition. In contrast, the chemical inhibition of gibberellic acid (GA) biosynthesis resulted in a strong attenuation of early flowering and FT expression in arp6. Furthermore, GA was able to induce flowering at low temperature (15°C) independently of FT, TSF, and the PIF genes, probably directly at the shoot apical meristem. Together, our results suggest that the timing of the floral transition in response to ambient temperature is more complex than previously thought and that GA signaling might play a crucial role in this process.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Current industrial atomic layer deposition (ALD) processes are almost wholly confined to glass or silicon substrates. For many industrial applications, deposition on polymer substrates will be necessary. Current deposition processes are also typically carried out at temperatures which are too high for polymers. If deposition temperatures in ALD can be reduced to the level applicable for polymers, it will open new interesting areas and applications for polymeric materials. The properties of polymers can be improved for example by coatings with functional and protective properties. Although the ALD has shown its capability to operate at low temperatures suitable for polymer substrates, there are other issues related to process efficiency and characteristics of different polymers where new knowledge will assist in developing industrially conceivable ALD processes. Lower deposition temperature in ALD generally means longer process times to facilitate the self limiting film growth mode characteristic to ALD. To improve process efficiency more reactive precursors are introduced into the process. For example in ALD oxide processes these can be more reactive oxidizers, such as ozone and oxygen radicals, to substitute the more conventionally used water. Although replacing water in the low temperature ALD with ozone or plasma generated oxygen radicals will enable the process times to be shortened, they may have unwanted effects both on the film growth and structure, and in some cases can form detrimental process conditions for the polymer substrate. Plasma assistance is a very promising approach to improve the process efficiency. The actual design and placement of the plasma source will have an effect on film growth characteristics and film structure that may retard the process efficiency development. Due to the fact that the lifetime of the radicals is limited, it requires the placement of the plasma source near to the film growth region. Conversely this subjects the substrate to exposure byother plasma species and electromagnetic radiation which sets requirements for plasma conditions optimization. In this thesis ALD has been used to modify, activate and functionalize the polymer surfaces for further improvement of polymer performance subject to application. The issues in ALD on polymers, both in thermal and plasma-assisted ALD will be further discussed.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

It is known already from 1970´s that laser beam is suitable for processing paper materials. In this thesis, term paper materials mean all wood-fibre based materials, like dried pulp, copy paper, newspaper, cardboard, corrugated board, tissue paper etc. Accordingly, laser processing in this thesis means all laser treatments resulting material removal, like cutting, partial cutting, marking, creasing, perforation etc. that can be used to process paper materials. Laser technology provides many advantages for processing of paper materials: non-contact method, freedom of processing geometry, reliable technology for non-stop production etc. Especially packaging industry is very promising area for laser processing applications. However, there are only few industrial laser processing applications worldwide even in beginning of 2010´s. One reason for small-scale use of lasers in paper material manufacturing is that there is a shortage of published research and scientific articles. Another problem, restraining the use of laser for processing of paper materials, is colouration of paper material i.e. the yellowish and/or greyish colour of cut edge appearing during cutting or after cutting. These are the main reasons for selecting the topic of this thesis to concern characterization of interaction of laser beam and paper materials. This study was carried out in Laboratory of Laser Processing at Lappeenranta University of Technology (Finland). Laser equipment used in this study was TRUMPF TLF 2700 carbon dioxide laser that produces a beam with wavelength of 10.6 μm with power range of 190-2500 W (laser power on work piece). Study of laser beam and paper material interaction was carried out by treating dried kraft pulp (grammage of 67 g m-2) with different laser power levels, focal plane postion settings and interaction times. Interaction between laser beam and dried kraft pulp was detected with different monitoring devices, i.e. spectrometer, pyrometer and active illumination imaging system. This way it was possible to create an input and output parameter diagram and to study the effects of input and output parameters in this thesis. When interaction phenomena are understood also process development can be carried out and even new innovations developed. Fulfilling the lack of information on interaction phenomena can assist in the way of lasers for wider use of technology in paper making and converting industry. It was concluded in this thesis that interaction of laser beam and paper material has two mechanisms that are dependent on focal plane position range. Assumed interaction mechanism B appears in range of average focal plane position of 3.4 mm and 2.4 mm and assumed interaction mechanism A in range of average focal plane position of 0.4 mm and -0.6 mm both in used experimental set up. Focal plane position 1.4 mm represents midzone of these two mechanisms. Holes during laser beam and paper material interaction are formed gradually: first small hole is formed to interaction area in the centre of laser beam cross-section and after that, as function of interaction time, hole expands, until interaction between laser beam and dried kraft pulp is ended. By the image analysis it can be seen that in beginning of laser beam and dried kraft pulp material interaction small holes off very good quality are formed. It is obvious that black colour and heat affected zone appear as function of interaction time. This reveals that there still are different interaction phases within interaction mechanisms A and B. These interaction phases appear as function of time and also as function of peak intensity of laser beam. Limit peak intensity is the value that divides interaction mechanism A and B from one-phase interaction into dual-phase interaction. So all peak intensity values under limit peak intensity belong to MAOM (interaction mechanism A one-phase mode) or to MBOM (interaction mechanism B onephase mode) and values over that belong to MADM (interaction mechanism A dual-phase mode) or to MBDM (interaction mechanism B dual-phase mode). Decomposition process of cellulose is evolution of hydrocarbons when temperature is between 380- 500°C. This means that long cellulose molecule is split into smaller volatile hydrocarbons in this temperature range. As temperature increases, decomposition process of cellulose molecule changes. In range of 700-900°C, cellulose molecule is mainly decomposed into H2 gas; this is why this range is called evolution of hydrogen. Interaction in this range starts (as in range of MAOM and MBOM), when a small good quality hole is formed. This is due to “direct evaporation” of pulp via decomposition process of evolution of hydrogen. And this can be seen can be seen in spectrometer as high intensity peak of yellow light (in range of 588-589 nm) which refers to temperature of ~1750ºC. Pyrometer does not detect this high intensity peak since it is not able to detect physical phase change from solid kraft pulp to gaseous compounds. As interaction time between laser beam and dried kraft pulp continues, hypothesis is that three auto ignition processes occurs. Auto ignition of substance is the lowest temperature in which it will spontaneously ignite in a normal atmosphere without an external source of ignition, such as a flame or spark. Three auto ignition processes appears in range of MADM and MBDM, namely: 1. temperature of auto ignition of hydrogen atom (H2) is 500ºC, 2. temperature of auto ignition of carbon monoxide molecule (CO) is 609ºC and 3. temperature of auto ignition of carbon atom (C) is 700ºC. These three auto ignition processes leads to formation of plasma plume which has strong emission of radiation in range of visible light. Formation of this plasma plume can be seen as increase of intensity in wavelength range of ~475-652 nm. Pyrometer shows maximum temperature just after this ignition. This plasma plume is assumed to scatter laser beam so that it interacts with larger area of dried kraft pulp than what is actual area of beam cross-section. This assumed scattering reduces also peak intensity. So result shows that assumably scattered light with low peak intensity is interacting with large area of hole edges and due to low peak intensity this interaction happens in low temperature. So interaction between laser beam and dried kraft pulp turns from evolution of hydrogen to evolution of hydrocarbons. This leads to black colour of hole edges.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Introduction: Patients with chronic kidney disease present selenium (Se) plasma deficiency which is an essential trace element with important biological functions and, the best known biological role is attributed to its presence in the antioxidant enzyme, glutathione peroxidase (GPx). The Se content of foods depends on soil and some authors have suggested that Amazon soil (North Brazilian region) has high Se concentrations when compared to other regions of Brazil. Objective: The objective of this work was to compare the Se status in hemodialysis (HD) patients from North and Southeast of Brazil. Methods: Thirty-eight patients from Southeast region (22 men and 16 women, 15% diabetic, 53.5 ± 26.4 yrs) were compared to 40 patients from North region (28 men and 12 women, 22.5% diabetic, 63.5 ± 11.9 yrs). Se in plasma was determined through atomic absorption spectrophotometry with hydride generation. Results: The plasma Se levels in patients from Southeast region were significantly lower (17.5 ± 11.9 μg/L) when compared to patients from the North (37.1 ± 15.8 μg/L) (p < 0.001). However, both patient groups presented low Se plasma levels when compared to recommended values (60- 120 μg/L). There was no correlation between plasma Se levels and analyzed parameters. Conclusion: We concluded that patients from North (Amazon) region present higher plasma Se levels when compared to the patients from Southeast of Brazil. However, independently of the region, HD patients presented Se deficiency.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The effect of constant temperature on the germination rate and percentage of two cotton seed lots was determined using a thermogradient plate. A gradient of 10 ºC to 40 ºC was established across the plate so that temperatures changed 2 ºC for each 5 cm increment in length, resulting in sixteen different temperature treatments. The optimal temperature zone for germination was 28 ºC to 30 ºC. As temperature decreased from the optimal zone, the rate of germination also decreased but germination percentages during the 10-day period were significantly lower only below 20 ºC. As temperature increased above the optimal zone, the rate of germination decreased and the percentage of germination sharply decreased above 32 ºC - 34 ºC. As expected, high quality cotton seed performed better than medium quality seed for a low temperature range (16 ºC to 22 ºC), but the most intriguing results were observed for the high temperatures range (36 ºC to38 ºC). The germination of medium quality cotton seed was consistently higher than for high quality seed, especially at 38 ºC after the second day of evaluation. This response has not been reported in the literature and further research is needed to better understand the germination physiology of cotton seed at high temperatures.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The far infrared reflectance of Sb2Te3 , Sbi.97Vo.o3Te3 and Sbi.94Cr .o6Te3 was measured near normal incidence at different temperatures (between 45K and 300K). The direct current resistivities of the above samples were also measured between the temperatures of 4K and 300K. Also Kramers Kronig (KK) analyses were performed on the reflectance spectra to obtain the optical conductivities. In the doped samples, it was observed that a phonon at 62cm-1 softens to about 55cm-1 on decreasing the temperature from 295K to 45K. Also, it was observed that the plasma frequency of the doped samples is independent of doping. The scattering rate for the vanadium doped sample was seen to be greater than that for the chromium doped sample despite the fact that vanadium impurity density is less than that of chromium. The Drude-Lorentz model fits to the KK optical conductivity show that the samples used in this work are conventional metals. Definitive measurements of the temperature dependence of the scattering rate across the ferromagnetic transition await equipment changes allowing measurements at low temperature using the mercury cadmium telluride (MCT) detector.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

A system comprised of a Bomem interferometer and a LT3-110 Heli-Tran cryostat was set up to measure the reflectance of materials in the mid-infrared spectral region. Several tests were conducted to ensure the consistency and reliability of the system. Silicon and Chromium, two materials with well known optical properties were measured to test the accuracy of the system, and the results were found to be in good agreement with the literature. Reflectance measurements on pure SnTe and several Pb and Mn-doped alloys were carried out. These materials were chosen because they exhibit a strong plasma edge in the mid infrared region. The optical conductivity and several related optical parameters were calculated from the measured reflectance. Very low temperature measurements were carried out in the far-infrared on Sn9SMn2Te, and the results are indicative of a spin glass phase at 0.8 K. Resistivity measurements were made at room temperature. The resistivity values were found, as expected, to decrease with increasing carrier concentration and to increase with increasing manganese concentration.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Although it is widely assumed that temperature affects pollutant toxicity, few studies have actually investigated this relationship. Moreover, such research as has been done has involved constant temperatures; circumstances which are rarely, if ever, actually experienced by north temperate, littoral zone cyprinid species. To investigate the effects of temperature regime on nickel toxicity in goldfish (Carassius auratus L.), 96- and 240-h LCSO values for the heavy metal pollutant, nickel (NiCI2.6H20), were initially determined at 2DoC (22.8 mg/L and 14.7 mg/L in artificially softened water). Constant temperature bioassays at 10°C, 20°C and 30°C were conducted at each of 0, 240-h and 96-h LCSO nickel concentrations for 240 hours. In order to determine the effects of temperature variation during nickel exposure it was imperative that the effects of a single temperature change be investigated before addressing more complex regimes. Single temperature changes of + 10°C or -10°C were imposed at rates of 2°C/h following exposures of between 24 hand 216 h. The effects of a single temperature change on mortality, and duration of toxicant exposure at high and low temperatures were evaluated. The effects of fluctuating temperatures during exposure were investigated through two regimes. The first set of bioassays imposed a sinewave diurnal cycle temperature (20.±.1DOC) throughout the 10 day exposure to 240-h LeSO Ni. The second set of investigations approximated cyprinid movement through the littoral zone by imposing directionally random temperature changes (±2°C at 2-h intervals), between extremes of 10° and 30°C, at 240-h LC50 Ni. Body size (i.e., total length, fork length, and weight) and exposure time were recorded for all fish mortalities. Cumulative mortality curves under constant temperature regimes indicated significantly higher mortality as temperature and nickel concentration were increased. At 1DOC no significant differences in mortality curves were evident in relation to low and high nickel test concentrations (Le., 16 mg/L and 20 mg/L). However at 20°C and 30°C significantly higher mortality was experienced in animals exposed to 20 mg/L Ni. Mortality at constant 10°C was significantly lower than at 30°C with 16 mg/L and was significantly loWer than each of 2DoC and 39°C tanks at 20 mg/L Ni exposure. A single temperature shift from 20°C to 1DoC resulted in a significant decrease in mortality rate and conversely, a single temperature shift from 20°C to 30°C resulted in a significant increase in mortality rate. Rates of mortality recorded during these single temperature shift assays were significantly different from mortality rates obtained under constant temperature assay conditions. Increased Ni exposure duration at higher temperatures resulted in highest mortality. Diurnally cycling temperature bioassays produced cumulative mortality curves approximating constant 20°C curves, with increased mortality evident after peaks in the temperature cycle. Randomly fluctuating temperature regime mortality curves also resembled constant 20°C tanks with mortalities after high temperature exposures (25°C - 30°C). Some test animals survived in all assays with the exception of the 30°C assays, with highest survival associated with low temperature and low Ni concentration. Post-exposure mortality occurred most frequently in individuals which had experienced high Ni concentrations and high temperatures during assays. Additional temperature stress imposed 2 - 12 weeks post exposure resulted in a single death out of 116 individuals suggesting that survivors are capable of surviving subsequent temperature stresses. These investigations suggest that temperature significantly and markedly affects acute nickel toxicity under both constant and fluctuating temperature regimes and plays a role in post exposure mortality and subsequent stress response.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Two groups of rainbow trout were acclimated to 20 , 100 , and 18 o C. Plasma sodium, potassium, and chloride levels were determined for both. One group was employed in the estimation of branchial and renal (Na+-K+)-stimulated, (HC0 3-)-stimulated, and CMg++)-dependent ATPase activities, while the other was used in the measurement of carbonic anhydrase activity in the blood, gill and kidney. Assays were conducted using two incubation temperature schemes. One provided for incubation of all preparations at a common temperature of 2S oC, a value equivalent to the upper incipient lethal level for this species. In the other procedure the preparations were incubated at the appropriate acclimation temperature of the sampled fish. Trout were able to maintain plasma sodium and chloride levels essentially constant over the temperature range employed. The different incubation temperature protocols produced different levels of activity, and, in some cases, contrary trends with respect to acclimation temperature. This information was discussed in relation to previous work on gill and kidney. The standing-gradient flow hypothesis was discussed with reference to the structure of the chloride cell, known thermallyinduced changes in ion uptake, and the enzyme activities obtained in this study. Modifications of the model of gill lon uptake suggested by Maetz (1971) were proposed; high and low temperature models resulting. In short, ion transport at the gill at low temperatures appears to involve sodium and chloride 2 uptake by heteroionic exchange mechanisms working in association w.lth ca.rbonlc anhydrase. G.l ll ( Na + -K + ) -ATPase and erythrocyte carbonic anhydrase seem to provide the supplemental uptake required at higher temperatures. It appears that the kidney is prominent in ion transport at low temperatures while the gill is more important at high temperatures. 3 Linear regression analyses involving weight, plasma ion levels, and enzyme activities indicated several trends, the most significant being the interrelationship observed between plasma sodium and chloride. This, and other data obtained in the study was considered in light of the theory that a link exists between plasma sodium and chloride regulatory mechanisms.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This thesis reports on the optical properties of the dilute magnetic semiconductors, Sb1.97 V 0.03 Te3 and Sb1.94Cr0.06Te3, along with the parent compound Sb2Te3' These materials develop a ferromagnetic state at low temperature with Curie temperatures of 22 K and 16 K respectively. All three samples were oriented such that the electric field vector of the light was perpendicular to the c-axis. The reflectance profile of these samples in the mid-infrared (500 to 3000 cm-1) shows a pronounced plasma edge which retracts with decreasing temperature. The far-infrared region of these samples exhibits a phonon at ~ 60 cm-1 which softens as temperature decreases. Kramers-Kronig analysis and a Drude-Lorentz model were employed to determine the optical constants of the bulk samples. The real part of the optical conductivity is shown to consist of intraband contributions at frequencies below the energy gap (~0.26 eV) and interband contributions at frequencies above the energy gap. The temperature dependence of the scattering rate show that a mix of phonon and impurity scattering are present, while the signature of traditional spin disorder (magnetic) scattering was difficult to confirm.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

La réalisation de dispositifs à des dimensions sous-micrométriques et nanométriques demande une maîtrise parfaite des procédés de fabrication, notamment ceux de gravure. La réalisation des ces dispositifs est complexe et les exigences en termes de qualité et de géométrie des profils de gravure imposent de choisir les conditions opératoires les mieux adaptées. Les simulations de l'évolution spatio-temporelle des profils de gravure que nous proposons dans cette thèse s'inscrivent parfaitement dans ce contexte. Le simulateur que nous avons réalisé offre la possibilité de mieux comprendre les processus qui entrent en jeu lors de la gravure par plasma de profils dans divers matériaux. Il permet de tester l'influence des paramètres du plasma sur la forme du profil et donc de déterminer les conditions opératoires optimales. La mise au point de ce simulateur s'appuie sur les concepts fondamentaux qui gouvernent la gravure par plasma. À partir de l'état des lieux des différentes approches numériques pouvant être utilisées, nous avons élaboré un algorithme stable et adaptable permettant de mettre en évidence l'importance de certains paramètres clés pour la réalisation de profils de gravure par un plasma à haute densité et à basse pression. Les capacités de cet algorithme ont été testées en étudiant d'une part la pulvérisation de Si dans un plasma d'argon et d'autre part, la gravure chimique assistée par les ions de SiO2/Si dans un plasma de chlore. Grâce aux comparaisons entre profils simulés et expérimentaux, nous avons montré l'importance du choix de certains paramètres, comme la nature du gaz utilisé et la pression du plasma, la forme initiale du masque, la sélectivité masque/matériau, le rapport de flux neutre/ion, etc. Nous avons aussi lié ces paramètres à la formation de défauts dans les profils, par exemple celle de facettes sur le masque, de parois concaves, et de micro-tranchées. Enfin, nous avons montré que le phénomène de redépôt des atomes pulvérisés entre en compétition avec la charge électrique de surface pour expliquer la formation de profils en V dans le Pt pulvérisé par un plasma d'argon.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Le recours au plasma pour stériliser des dispositifs médicaux (DM) est un domaine de recherche ne datant véritablement que de la fin des années 1990. Les plasmas permettent, dans les conditions adéquates, de réaliser la stérilisation à basse température (≤ 65°C), tel qu’exigé par la présence de polymères dans les DM et ce contrairement aux procédés par chaleur, et aussi de façon non toxique, contrairement aux procédés chimiques comme, par exemple, l’oxyde d’éthylène (OEt). Les laboratoires du Groupe de physique des plasmas à l’Université de Montréal travaillent à l’élaboration d’un stérilisateur consistant plus particulièrement à employer les effluents d’une décharge N2-%O2 basse pression (2-8 Torrs) en flux, formant ce que l’on appelle une post-décharge en flux. Ce sont les atomes N et O de cette décharge qui viendront, dans les conditions appropriées, entrer en collisions dans la chambre de stérilisation pour y créer des molécules excitées NO*, engendrant ainsi l’émission d’une quantité appréciable de photons UV. Ceux-ci constituent, dans le cas présent, l’agent biocide qui va s’attaquer directement au bagage génétique du micro-organisme (bactéries, virus) que l’on souhaite inactiver. L’utilisation d’une lointaine post-décharge évite du même coup la présence des agents érosifs de la décharge, comme les ions et les métastables. L’un des problèmes de cette méthode de stérilisation est la réduction du nombre de molécules NO* créées par suite de la perte des atomes N et O, qui sont des radicaux connus pour interagir avec les surfaces, sur les parois des matériaux des DM que l’on souhaite stériliser. L’objectif principal de notre travail est de déterminer l’influence d’une telle perte en surface, dite aussi réassociation en surface, par l’introduction de matériaux comme le Téflon, l’acier inoxydable, l’aluminium et le cuivre sur le taux d’inactivation des spores bactériennes. Nous nous attendons à ce que la réassociation en surface de ces atomes occasionne ainsi une diminution de l’intensité UV et subséquemment, une réduction du taux d’inactivation. Par spectroscopie optique d’émission (SOE), nous avons déterminé les concentrations perdues de N et de O par la présence des matériaux dans le stérilisateur, ainsi que la diminution de l’émission UV en découlant. Nous avons observé que cette diminution des concentrations atomiques est d’autant plus importante que les surfaces sont catalytiques. Au cours de l’étude du phénomène de pertes sur les parois pour un mélange N2-%O2 nous avons constaté l’existence d’une compétition en surface entre les atomes N et O, dans laquelle les atomes d’oxygènes semblent dominer largement. Cela implique qu’au-delà d’un certain %O2 ajouté à la décharge N2, seuls les atomes O se réassocient en surface. Par ailleurs, l’analyse des courbes de survie bi-phasiques des micro-organismes a permis d’établir une étroite corrélation, par lien de cause à effet, entre la consommation des atomes N et O en surface et la diminution du taux d’inactivation des spores dans la première phase. En revanche, nous avons constaté que notre principal agent biocide (le rayonnement ultraviolet) est moins efficace dans la deuxième phase et, par conséquent, il n’a pas été possible d’établir un lien entre la diminution des concentrations et le taux d’inactivation de cette phase-là.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Dans cette thèse, nous démontrons des travaux sur la synthèse à faible coût des matériaux de cathode et l'anode pour les piles lithium-ion. Pour les cathodes, nous avons utilisé des précurseurs à faible coût pour préparer LiFePO4 et LiFe0.3Mn0.7PO4 en utilisant une méthode hydrothermale. Tout d'abord, des matériaux composites (LiFePO4/C) ont été synthétisés à partir d'un précurseur de Fe2O3 par une procédé hydrothermique pour faire LiFePO4(OH) dans une première étape suivie d'une calcination rapide pour le revêtement de carbone. Deuxièmement, LiFePO4 avec une bonne cristallinité et une grande pureté a été synthétisé en une seule étape, avec Fe2O3 par voie hydrothermale. Troisièmement, LiFe0.3Mn0.7PO4 a été préparé en utilisant Fe2O3 et MnO comme des précurseurs de bas coûts au sein d'une méthode hydrothermale synthétique. Pour les matériaux d'anode, nous avons nos efforts concentré sur un matériau d'anode à faible coût α-Fe2O3 avec deux types de synthèse hydrothermales, une a base de micro-ondes (MAH) l’autre plus conventionnelles (CH). La nouveauté de cette thèse est que pour la première fois le LiFePO4 a été préparé par une méthode hydrothermale en utilisant un précurseur Fe3+ (Fe2O3). Le Fe2O3 est un précurseur à faible coût et en combinant ses coûts avec les conditions de synthèse à basse température nous avons réalisé une réduction considérable des coûts de production pour le LiFePO4, menant ainsi à une meilleure commercialisation du LiFePO4 comme matériaux de cathode dans les piles lithium-ion. Par cette méthode de préparation, le LiFePO4/C procure une capacité de décharge et une stabilité de cycle accrue par rapport une synthétisation par la méthode à l'état solide pour les mêmes précurseurs Les résultats sont résumés dans deux articles qui ont été récemment soumis dans des revues scientifiques.