995 resultados para immediate dental implant loading
Resumo:
Recent studies in animals have shown pronounced resorption of the buccal bone plate after immediate implantation. The use of flapless surgical procedures prior to the installation of immediate implants, as well as the use of synthetic bone graft in the gaps represent viable alternatives to minimize buccal bone resorption and to favor osseointegration. The aim of this study was to evaluate the healing of the buccal bone plate following immediate implantation using the flapless approach, and to compare this process with sites in which a synthetic bone graft was or was not inserted into the gap between the implant and the buccal bone plate. Lower bicuspids from 8 dogs were bilaterally extracted without the use of flaps, and 4 implants were installed in the alveoli in each side of the mandible and were positioned 2.0 mm from the buccal bone plate (gap). Four groups were devised: 2.0-mm subcrestal implants (3.3 x 8 mm) using bone grafts (SCTG), 2.0-mm subcrestal implants without bone grafts (SCCG), equicrestal implants (3.3 x 10 mm) with bone grafts (EGG), and equicrestal implants without bone grafts (ECCG). One week following the surgical procedures, metallic prostheses were installed, and within 12 weeks the dogs were sacrificed. The blocks containing the individual implants were turned sideways, and radiographic imaging was obtained to analyze the remodeling of the buccal bone plate. In the analysis of the resulting distance between the implant shoulder and the bone crest, statistically significant differences were found in the SCTG when compared to the ECTG (P = .02) and ECCG (P = .03). For mean value comparison of the resulting linear distance between the implant surface and the buccal plate, no statistically significant difference was found among all groups (P > .05). The same result was observed in the parameter for presence or absence of tissue formation between the implant surface and buccal plate. Equicrestally placed implants, in this methodology, presented little or no loss of the buccal bone. The subcrestally positioned implants presented loss of buccal bone, even though synthetic bone graft was used. The buccal bone, however, was always coronal to the implant shoulder.
Resumo:
Background: Accelerating bone healing around dental implants can reduce the long-term period between the insertion of implants and functional rehabilitation. Objective: This in vivo study evaluated the effect of a constant electromagnetic field (CEF) on bone healing around dental implants in dogs. Materials and methods: Eight dental implants were placed immediately after extraction of the first premolar and molar teeth on the mandible of two male dogs and divided into experimental (CEF) and control groups. A CEF at magnetic intensity of 0.8 mT with a pulse width of 25 mu s and frequency of 1.5 MHz was applied on the implants for 20 min per day for 2 weeks. Result and conclusion: After qualitative histological analysis, a small quantity of newly formed bone was observed in the gap between the implant surface and alveolar bone in both groups.
Resumo:
Objective: To evaluate healing time before loading, areas compression and tension and location of insertion on mini-implant stability. Design: Six minipigs were used. Each animal received 3 mini-implants in each quadrant: 1 mini-implant was used as an unloaded control (G1, n = 24); the other 2 were loaded with 150 g-force at three time intervals (G2: immediate loading, G3: after 15 days and G4: after 30 days), with 16 mini-implant in each experimental group. After 120 days, tissue blocks of the areas of interest were harvested. Clinical analysis (exact Fisher test) determined the survival rate. Histological analysis (Kontron KS 300TM, Zeiss) quantified the fractional bone-toimplant contact (%BIC) and bone area (%BA) at each healing time point, areas of interest, and insertion site (ANOVA and t tests for dependent and independent samples). Results: The mini-implant survival rates were G1: 71%, G2: 50%, G3: 75% and G4: 63%, with no statistical differences between them. The groups presented similar %BIC and %BA. There were no differences between the compression and tension sides or maxillary and mandibular insertion sites. Conclusions: These results suggest that low-intensity immediate or early orthodontic loading does not affect mini-implant stability, because similar histomorphometric results were observed for all the groups, with partial osseointegration of the mini-implants present.
Resumo:
OBJECTIVES: To compare the clinical outcomes of standard, cylindrical, screw-shaped to novel tapered, transmucosal (Straumann Dental implants immediately placed into extraction sockets. Material and methods: In this randomized-controlled clinical trial, outcomes were evaluated over a 3-year observation period. This report deals with the need for bone augmentation, healing events, implant stability and patient-centred outcomes up to 3 months only. Nine centres contributed a total of 208 immediate implant placements. All surgical and post-surgical procedures and the evaluation parameters were discussed with representatives of all centres during a calibration meeting. Following careful luxation of the designated tooth, allocation of the devices was randomly performed by a central study registrar. The allocated SLA titanium implant was installed at the bottom or in the palatal wall of the extraction socket until primary stability was reached. If the extraction socket was >or=1 mm larger than the implant, guided bone regeneration was performed simultaneously (Bio Oss and BioGide. The flaps were then sutured. During non-submerged transmucosal healing, everything was done to prevent infection. At surgery, the need for augmentation and the degree of wound closure was verified. Implant stability was assessed clinically and by means of resonance frequency analysis (RFA) at surgery and after 3 months. Wound healing was evaluated after 1, 2, 6 and 12 weeks post-operatively. RESULTS: The demographic data did not show any differences between the patients receiving either standard cylindrical or tapered implants. All implants yielded uneventful healing with 15% wound dehiscences after 1 week. After 2 weeks, 93%, after 6 weeks 96%, and after 12 weeks 100% of the flaps were closed. Ninety percent of both implant designs required bone augmentation. Immediately after implantation, RFA values were 55.8 and 56.7 and at 3 months 59.4 and 61.1 for cylindrical and tapered implants, respectively. Patient-centred outcomes did not differ between the two implant designs. However, a clear preference of the surgeon's perception for the appropriateness of the novel-tapered implant was evident. CONCLUSIONS: This RCT has demonstrated that tapered or standard cylindrical implants yielded clinically equivalent short-term outcomes after immediate implant placement into the extraction socket.
Resumo:
PURPOSE: The aim of this prospective case series study was to evaluate the short-term success rates of titanium screw-type implants with a chemically modified sand-blasted and acid-etched (mod SLA) surface after 3 weeks of healing. MATERIAL AND METHODS: A total of 56 implants were inserted in the posterior mandible of 40 partially edentulous patients exhibiting bone densities of class I to III. After a healing period of 3 weeks, all implants were functionally loaded with a screw-retained crown or fixed dental prosthesis. The patients were recalled at weeks 4, 7, 12, and 26 for monitoring and assessment of clinical and radiological parameters, including implant stability quotient (ISQ) measurements. RESULTS: None of the implants failed to integrate. However, two implants were considered "spinners" at day 21 and left unloaded for an extended period. Therefore, 96.4% of the inserted implants were loaded according to the protocol tested. All 56 implants including the "spinners" showed favorable clinical and radiographic findings at the 6-month follow-up examination. The ISQ values increased steadily throughout the follow-up period. At the time of implant placement, the range of ISQ values exhibited a mean of 74.33, and by week 26, a mean value of 83.82 was recorded. Based on strict criteria, all 56 implants were considered successfully integrated, resulting in a 6-month survival and success rate of 100.0%. CONCLUSION: This prospective study using an early-loading protocol after 3 weeks of healing demonstrated that titanium implants with the modified SLA surface can achieve and maintain successful tissue integration over a period of at least 6 months. The ISQ method seems feasible to monitor implant stability during the initial wound-healing period.
Resumo:
The complete dental rehabilitation of a patient with a failing dentition using fixed implant-supported prostheses requires carefully planned and well-sequenced treatment. This case report presents the treatment steps and sequencing for a patient in whom removable provisional prostheses were not an option. While an immediate loading protocol was used in the mandible, a staged approach featuring strategic extractions and implant placement in several phases was applied in the maxilla. The major advantage of this treatment protocol was that the patient was maintained in fixed prostheses throughout the treatment.
Resumo:
PURPOSE The objectives of this systematic review are (1) to quantitatively estimate the esthetic outcomes of implants placed in postextraction sites, and (2) to evaluate the influence of simultaneous bone augmentation procedures on these outcomes. MATERIALS AND METHODS Electronic and manual searches of the dental literature were performed to collect information on esthetic outcomes based on objective criteria with implants placed after extraction of maxillary anterior and premolar teeth. All levels of evidence were accepted (case series studies required a minimum of 5 cases). RESULTS From 1,686 titles, 114 full-text articles were evaluated and 50 records included for data extraction. The included studies reported on single-tooth implants adjacent to natural teeth, with no studies on multiple missing teeth identified (6 randomized controlled trials, 6 cohort studies, 5 cross-sectional studies, and 33 case series studies). Considerable heterogeneity in study design was found. A meta-analysis of controlled studies was not possible. The available evidence suggests that esthetic outcomes, determined by esthetic indices (predominantly the pink esthetic score) and positional changes of the peri-implant mucosa, may be achieved for single-tooth implants placed after tooth extraction. Immediate (type 1) implant placement, however, is associated with a greater variability in outcomes and a higher frequency of recession of > 1 mm of the midfacial mucosa (eight studies; range 9% to 41% and median 26% of sites, 1 to 3 years after placement) compared to early (type 2 and type 3) implant placement (2 studies; no sites with recession > 1 mm). In two retrospective studies of immediate (type 1) implant placement with bone graft, the facial bone wall was not detectable on cone beam CT in 36% and 57% of sites. These sites had more recession of the midfacial mucosa compared to sites with detectable facial bone. Two studies of early implant placement (types 2 and 3) combined with simultaneous bone augmentation with GBR (contour augmentation) demonstrated a high frequency (above 90%) of facial bone wall visible on CBCT. Recent studies of immediate (type 1) placement imposed specific selection criteria, including thick tissue biotype and an intact facial socket wall, to reduce esthetic risk. There were no specific selection criteria for early (type 2 and type 3) implant placement. CONCLUSIONS Acceptable esthetic outcomes may be achieved with implants placed after extraction of teeth in the maxillary anterior and premolar areas of the dentition. Recession of the midfacial mucosa is a risk with immediate (type 1) placement. Further research is needed to investigate the most suitable biomaterials to reconstruct the facial bone and the relationship between long-term mucosal stability and presence/absence of the facial bone, the thickness of the facial bone, and the position of the facial bone crest.
Resumo:
OBJECTIVES: The purpose of this in vitro study was to evaluate misfit alterations at the implant/abutment interface of external and internal connection implant systems when subjected to cyclic loading. MATERIAL AND METHODS: Standard metal crowns were fabricated for 5 groups (n=10) of implant/abutment assemblies: Group 1, external hexagon implant and UCLA cast-on premachined abutment; Group 2, internal hexagon implant and premachined abutment; Group 3, internal octagon implant and prefabricated abutment; Group 4, external hexagon implant and UCLA cast-on premachined abutment; and Group 5, external hexagon implant and Ceraone abutment. For groups 1, 2, 3 and 5, the crowns were cemented on the abutments and in group 4 crowns were screwed directly on the implant. The specimens were subjected to 500,000 cycles at 19.1 Hz of frequency and non-axial load of 133 N in a MTS 810 machine. The vertical misfit (μm) at the implant/abutment interface was evaluated before (B) and after (A) application of the cyclic loading. Data were analyzed statistically by using two-away ANOVA and Tukey's post-hoc test (p<0.05). RESULTS: Before loading values showed no difference among groups 2 (4.33±3.13), 3 (4.79±3.43) and 5 (3.86±4.60); between groups 1 (12.88±6.43) and 4 (9.67±3.08), and among groups 2, 3 and 4. However, groups 1 and 4 were significantly different from groups 2, 3 and 5. After loading values of groups 1 (17.28±8.77) and 4 (17.78±10.99) were significantly different from those of groups 2 (4.83±4.50), 3 (8.07±4.31) and 5 (3.81±4.84). There was a significant increase in misfit values of groups 1, 3 and 4 after cyclic loading, but not for groups 2 and 5. CONCLUSIONS: The cyclic loading and type of implant/abutment connection may develop a role on the vertical misfit at the implant/abutment interface.
Resumo:
Background: The effects of etonogestrel (ETG)-releasing contraceptive implant during the immediate postpartum period on maternal safety are unknown. Study design: Forty healthy women exclusively breastfeeding were randomized to receive either ETG-releasing implant 24-48 h after delivery (n=20) or depot medroxyprogesterone acetate (DMPA group; n=20) at the sixth week postpartum. We measured blood pressure, maternal and neonatal weight, body mass index (BMI; kg/m(2)), waist circumference (WC), complete blood count, C-reactive protein, interleukin-6, tumor necrosis factor (TNF-alpha), lipid profile, fasting serum glucose and maintenance of exclusive lactation up to the 12th week postpartum. Results: Decreases in mean maternal weight, BMI (kg/m(2)) and WC were significantly greater in the ETG-releasing implant group than in the MPA group during the first 6 weeks postpartum (-4.64 +/- 2.71 kg vs. -2.6 +/- 2.45 kg mean +/- SD, p=.017; -1.77 +/- 1.06 kg/m(2) vs. -0.97 +/- 0.95 kg/m(2), p=.026; -15.3 +/- 6.72 cm vs. -9.05 +/- 5.84 cm, p=.003, respectively). In addition, total cholesterol and HDL, were lower in DMPA users, and TNF-alpha and leukocytes were higher in DMPA users compared to in the implant group, between 6 and 12 weeks after delivery. The newborns of implant users showed a trend towards gaining more weight, as compared with the infants of the DMPA mothers during the first 6 weeks of life (implant group: +1460.50 +/- 621.34 g vs. DMPA group: +1035.0 +/- 562.43 g, p=.05). The remaining variables, including the duration of exclusive breastfeeding, were similar between the groups. Conclusion: The insertion of ETG-releasing contraceptive implant during the immediate postpartum period was not associated with deleterious maternal clinical effects or with significant maternal metabolic alterations or decreased infant weight gain. (C) 2009 Elsevier Inc. All rights reserved.
Resumo:
Purpose: To evaluate the qualitative and quantitative differences on dental plaque formation on two different roughness titanium implant surfaces, i.e. machined and titanium plasma sprayed, as well as the amount of plaque removal by regular toothbrushing after 72-hour plaque accumulation. Methods: Eight systemically healthy subjects were recruited from the patient pool of a private dental practice. All patients underwent oral hygiene instruction and full mouth prophylaxis. Subsequently, maxillary casts from all patients were obtained and removable 0.7 mm-thick acetate stents without occlusal contact points were fabricated to support four titanium specimens of 4x2x2 mm divided into two groups (machined and plasma sprayed). Subjects were instructed to wear the stents for 72 hours, full time, removing them only during regular oral hygiene. Subsequently, the appliances were immediately repositioned and then the test side was brushed for 20 seconds. At the end of the 72-hour period, the stents were removed and prepared for microbiological analysis. Results: Both machined and plasma sprayed brushed surfaces presented statistically significant fewer bacteria than non-brushed surfaces. Similarly, regarding surface roughness, machined surfaces presented a total number of bacteria significantly smaller than those presented by plasma sprayed surfaces (P< 0.05). Statistically, the non-brushed machined turned surfaces presented a greater amount of Streptoccocus sp. when compared to the brushed machined surfaces. It was concluded that rough surfaces accumulated more dental plaque than polished surfaces. Both brushed surfaces presented less plaque accumulation, however, implant brushing was more effective on machined surfaces. (Am J Dent 2008;21:318-322).
Resumo:
Clinical feasibility of mandibular implant overdenture retainers submitted to immediate load Introduction: Millions of people around the world do not have access to the benefits of osseointegration. Treatments involving oral rehabilitation with overdentures have been widely used by specialists in the oral medicine field. This is an alternative therapy for retention and stability achievement in total prosthesis with conventional treatment, and two implants are enough to establish a satisfactory overdenture. Objective: The objectives of the study were to evaluate 16 patients of both sexes, with an average age of 47.4 +/- 4 years, using electromyographic analysis of masseter and temporal muscles and analyse the increase of incisive and molar maximal bite force with their existing complete dentures and following mandibular implant overdenture therapy to assess the benefits of this treatment. Materials and methods: For these tests, the Myosystem-BR1 electromyograph and the IDDK Kratos dynamometer were used. Statistical analysis was performed using the repeated measures test (SPSS 17.0). Results: A decrease in electromyographic activity during the rest, lateral and protrusion movements and increase of the maximal incisive and molar bite force after 15 months with a mandibular implant overdenture was observed. Conclusion: All the patients in this study reported a considerable improvement in the masticatory function and prostheses stability following treatment. It is possible to propose that the use of mandibular implants overdenture should become the selected treatment for totally edentulous patients to facilitate oral function and quality of life.
Resumo:
Fiber-reinforced composites (FRCs) are a new group of non-metallic biomaterials showing a growing popularity in many dental and medical applications. As an oral implant material, FRC is biocompatible in bone tissue environment. Soft tissue integration to FRC polymer material is unclear. This series of in vitro studies aimed at evaluating unidirectional E-glass FRC polymer in terms of mechanical, chemical, and biological properties in an attempt to develop a new non-metallic oral implant abutment alternative. Two different types of substrates were investigated: (a) Plain polymer (BisGMA 50%–TEGDMA 50%) and (b) Unidirectional FRC. The mechanical behavior of high fiber-density FRCs was assessed using a three-point bending test. Surface characterization was performed using scanning electron and spinning disk confocal microscopes. The surface wettability/energy was determined using sessile drop method. The blood response, including blood-clotting ability and platelet morphology was evaluated. Human gingival fibroblast cell responses - adhesion kinetics, adhesion strength, and proliferation activity - were studied in cell culture environment using routine test conditions. A novel tissue culture method was developed and used to evaluate porcine gingival tissue graft attachment and growth on the experimental composite implants. The analysis of the mechanical properties showed that there is a direct proportionality in the relationship between E-glass fiber volume fraction and toughness, modulus of elasticity, and load bearing capacity; however, flexural strength did not show significant improvement when high fiber-density FRC is used. FRCs showed moderate hydrophilic properties owing to the presence of exposed glass fibers on the polymer surface. Blood-clotting time was shorter on FRC substrates than on plain polymer. The FRC substrates also showed higher platelet activation state than plain polymer substrates. Fibroblast cell adhesion strength and proliferation rate were highly pronounced on FRCs. A tissue culture study revealed that gingival epithelium and connective tissue established an immediate close contact with both plain polymer and FRC implants. However, FRC seemed to guide epithelial migration outwards from the tissue/implant interface. Due to the anisotropic and hydrophilic nature of FRC, it can be concluded that this material enhances biological events related with soft tissue integration on oral implant surface.
Resumo:
Internal tapered connections were developed to improve biomechanical properties and to reduce mechanical problems found in other implant connection systems. The purpose of this study was to evaluate the effects of mechanical loading and repeated insertion/removal cycles on the torque loss of abutments with internal tapered connections. Sixty-eight conical implants and 68 abutments of two types were used. They were divided into four groups: groups 1 and 3 received solid abutments, and groups 2 and 4 received two-piece abutments. In groups 1 and 2, abutments were simply installed and uninstalled; torque-in and torque-out values were measured. In groups 3 and 4, abutments were installed, mechanically loaded and uninstalled; torque-in and torque-out values were measured. Under mechanical loading, two-piece abutments were frictionally locked into the implant; thus, data of group 4 were catalogued under two subgroups (4a: torque-out value necessary to loosen the fixation screw; 4b: torque-out value necessary to remove the abutment from the implant). Ten insertion/removal cycles were performed for every implant/abutment assembly. Data were analyzed with a mixed linear model (P <= 0.05). Torque loss was higher in groups 4a and 2 (over 30% loss), followed by group 1 (10.5% loss), group 3 (5.4% loss) and group 4b (39% torque gain). All the results were significantly different. As the number of insertion/removal cycles increased, removal torques tended to be lower. It was concluded that mechanical loading increased removal torque of loaded abutments in comparison with unloaded abutments, and removal torque values tended to decrease as the number of insertion/removal cycles increased. To cite this article:Ricciardi Coppede A, de Mattos MdaGC, Rodrigues RCS, Ribeiro RF. Effect of repeated torque/mechanical loading cycles on two different abutment types in implants with internal tapered connections: an in vitro study.Clin. Oral Impl. Res. 20, 2009; 624-632.doi: 10.1111/j.1600-0501.2008.01690.x.
Resumo:
The objective of this study was to verify if differences in the design of internal hex (IH) and internal conical (IC) connection implant systems influence fracture resistance under oblique compressive forces. Twenty implant-abutment assemblies were utilized: 10 with IH connections and 10 with IC connections. Maximum deformation force for IC implants (90.58 +/- 6.72 kgf) was statistically higher than that for IH implants (83.73 +/- 4.94 kgf) (P = .0182). Fracture force for the IH implants was 79.86 +/- 4.77 kgf. None of the IC implants fractured. The friction-locking mechanics and the solid design of the IC abutments provided greater resistance to deformation and fracture under oblique compressive loading when compared to the IH abutments. Int J Prosthodont 2009;22:283-286.
Resumo:
Aim To study osseointegration and bone-level changes at implants installed using either a standard or a reduced diameter bur for implant bed preparation. Material and methods In six Labrador dogs, the first and second premolars were extracted bilaterally. Subsequently, mesial roots of the first molars were endodontically treated and distal roots, including the corresponding part of the crown, were extracted. After 3 months of healing, flaps were elevated and recipient sites were prepared in all experimental sites. The control site was prepared using a standard procedure, while the test site was prepared using a drill with a 0.2 mm reduced diameter than the standard one used in the contra-lateral side. After 4 months of healing, the animals were euthanized and biopsies were obtained for histological processing and evaluation. Results With the exception of one implant that was lost, all implants were integrated in mineralized bone. The alveolar crest underwent resorption at control as well as at test sites (buccal aspect similar to 1 mm). The most coronal contact of bone-to-implant was located between 1.2 and 1.6 mm at the test and between 1.3 and 1.7 mm at the control sites. Bone-to-implant contact percentage was between 49% and 67%. No statistically significant differences were found for any of the outcome variables. Conclusions After 4 months of healing, lateral pressure to the implant bed as reflected by higher insertion torques (36 vs. 15 N cm in the premolar and 19 vs. 7 N cm in the molar regions) did not affect the bone-to-implant contact. To cite this article:Pantani F, Botticelli D, Garcia IR Jr., Salata LA, Borges GJ, Lang NP. Influence of lateral pressure to the implant bed on osseointegration: an experimental study in dogs.Clin. Oral Impl. Res. 21, 2010; 1264-1270.doi: 10.1111/j.1600-0501.2009.01941.x.