961 resultados para high vaccine dose


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: The most recent Varian® micro multileaf collimator(MLC), the High Definition (HD120) MLC, was modeled using the BEAMNRCMonte Carlo code. This model was incorporated into a Varian medical linear accelerator, for a 6 MV beam, in static and dynamic mode. The model was validated by comparing simulated profiles with measurements. Methods: The Varian® Trilogy® (2300C/D) accelerator model was accurately implemented using the state-of-the-art Monte Carlo simulation program BEAMNRC and validated against off-axis and depth dose profiles measured using ionization chambers, by adjusting the energy and the full width at half maximum (FWHM) of the initial electron beam. The HD120 MLC was modeled by developing a new BEAMNRC component module (CM), designated HDMLC, adapting the available DYNVMLC CM and incorporating the specific characteristics of this new micro MLC. The leaf dimensions were provided by the manufacturer. The geometry was visualized by tracing particles through the CM and recording their position when a leaf boundary is crossed. The leaf material density and abutting air gap between leaves were adjusted in order to obtain a good agreement between the simulated leakage profiles and EBT2 film measurements performed in a solid water phantom. To validate the HDMLC implementation, additional MLC static patterns were also simulated and compared to additional measurements. Furthermore, the ability to simulate dynamic MLC fields was implemented in the HDMLC CM. The simulation results of these fields were compared with EBT2 film measurements performed in a solid water phantom. Results: Overall, the discrepancies, with and without MLC, between the opened field simulations and the measurements using ionization chambers in a water phantom, for the off-axis profiles are below 2% and in depth-dose profiles are below 2% after the maximum dose depth and below 4% in the build-up region. On the conditions of these simulations, this tungsten-based MLC has a density of 18.7 g cm− 3 and an overall leakage of about 1.1 ± 0.03%. The discrepancies between the film measured and simulated closed and blocked fields are below 2% and 8%, respectively. Other measurements were performed for alternated leaf patterns and the agreement is satisfactory (to within 4%). The dynamic mode for this MLC was implemented and the discrepancies between film measurements and simulations are within 4%. Conclusions: The Varian® Trilogy® (2300 C/D) linear accelerator including the HD120 MLC was successfully modeled and simulated using the Monte CarloBEAMNRC code by developing an independent CM, the HDMLC CM, either in static and dynamic modes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study evaluates the dosimetric impact caused by an air cavity located at 2 mm depth from the top surface in a PMMA phantom irradiated by electron beams produced by a Siemens Primus linear accelerator. A systematic evaluation of the effect related to the cavity area and thickness as well as to the electron beam energy was performed by using Monte Carlo simulations (EGSnrc code), Pencil Beam algorithm and Gafchromic EBT2 films. A home-PMMA phantom with the same geometry as the simulated one was specifically constructed for the measurements. Our results indicate that the presence of the cavity causes an increase (up to 70%) of the dose maximum value as well as a shift forward of the position of the depthedose curve, compared to the homogeneous one. Pronounced dose discontinuities in the regions close to the lateral cavity edges are observed. The shape and magnitude of these discontinuities change with the dimension of the cavity. It is also found that the cavity effect is more pronounced (6%) for the 12 MeV electron beam and the presence of cavities with large thickness and small area introduces more significant variations (up to 70%) on the depthedose curves. Overall, the Gafchromic EBT2 film measurements were found in agreement within 3% with Monte Carlo calculations and predict well the fine details of the dosimetric change near the cavity interface. The Pencil Beam calculations underestimate the dose up to 40% compared to Monte Carlo simulations; in particular for the largest cavity thickness (2.8 cm).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Mestrado em Radiações Aplicadas às Tecnologias da Saúde - Ramo de especialização: Imagem Digital com Radiação X

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE To analyze the costs of vaccination regimens for introducing inactivated polio vaccine in routine immunization in Brazil.METHODS A cost analysis was conducted for vaccines in five vaccination regimens, including inactivated polio vaccine, compared with the oral polio vaccine-only regimen. The costs of the vaccines were estimated for routine use and for the “National Immunization Days”, during when the oral polio vaccine is administered to children aged less than five years, independent of their vaccine status, and the strategic stock of inactivated polio vaccine. The presented estimated costs are of 2011.RESULTS The annual costs of the oral vaccine-only program (routine and two National Immunization Days) were estimated at US$19,873,170. The incremental costs of inclusion of the inactivated vaccine depended on the number of vaccine doses, presentation of the vaccine (bottles with single dose or ten doses), and number of “National Immunization Days” carried out. The cost of the regimen adopted with two doses of inactivated vaccine followed by three doses of oral vaccine and one “National Immunization Day” was estimated at US$29,653,539. The concomitant replacement of the DTPw/Hib and HepB vaccines with the pentavalent vaccine enabled the introduction of the inactivated polio without increasing the number of injections or number of visits needed to complete the vaccination.CONCLUSIONS The introduction of the inactivated vaccine increased the annual costs of the polio vaccines by 49.2% compared with the oral vaccine-only regimen. This increase represented 1.13% of the expenditure of the National Immunization Program on the purchase of vaccines in 2011.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Patients scheduled for a magnetic resonance imaging (MRI) scan sometimes require screening for ferromagnetic Intra Orbital Foreign Bodies (IOFBs). To assess this, they are required to fill out a screening protocol questionnaire before their scan. If it is established that a patient is at high risk, radiographic imaging is necessary. This review examines literature to evaluate which imaging modality should be used to screen for IOFBs, considering that the eye is highly sensitive to ionising radiation and any dose should be minimised. Method: Several websites and books were searched for information, these were as follows: PubMed, Science Direct, Web of Knowledge and Google Scholar. The terms searched related to IOFB, Ionising radiation, Magnetic Resonance Imaging Safety, Image Quality, Effective Dose, Orbits and X-ray. Thirty five articles were found, several were rejected due to age or irrelevance; twenty eight were eventually accepted. Results: There are several imaging techniques that can be used. Some articles investigated the use of ultrasound for investigation of ferromagnetic IOFBs of the eye and others discussed using Computed Tomography (CT) and X-ray. Some gaps in the literature were identified, mainly that there are no articles which discuss the lowest effective dose while having adequate image quality for orbital imaging. Conclusion: X-ray is the best method to identify IOFBs. The only problem is that there is no research which highlights exposure factors that maintain sufficient image quality for viewing IOFBs and keep the effective dose to the eye As Low As Reasonably Achievable (ALARA).

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: To determine whether using different combinations of kVp and mAs with additional filtration can reduce the effective dose to a paediatric phantom whilst maintaining diagnostic image quality. Methods: 27 images of a paediatric AP pelvis phantom were acquired with different kVp, mAs and additional copper filtration. Images were displayed on quality controlled monitors with dimmed lighting. Ten diagnostic radiographers (5 students and 5 experienced radiographers) had eye tests to assess visual acuity before rating the images. Each image was rated for visual image quality against a reference image using 2 alternative forced choice software using a 5-point Likert scale. Physical measures (SNR and CNR) were also taken to assess image quality. Results: Of the 27 images rated, 13 of them were of acceptable image quality and had a dose lower than the image with standard acquisition parameters. Two were produced without filtration, 6 with 0.1mm and 5 with 0.2mm copper filtration. Statistical analysis found that the inter-rater and intra-rater reliability was high. Discussion: It is possible to obtain an image of acceptable image quality with a dose that is lower than published guidelines. There are some areas of the study that could be improved. These include using a wider range of kVp and mAs to give an exact set of parameters to use. Conclusion: Additional filtration has been identified as amajor tool for reducing effective dose whilst maintaining acceptable image quality in a 5 year old phantom.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The present study evaluates the humoral and cellular immune responses in 35 volunteers submited to short antirabies vaccination schedules with the Fuenzalida & Palacios vaccine based on the administration of doses on non consecutive days. The volunteers were divided into two groups. The first group received a total number of five doses given on days 0, 4, 7, 20 and 35. The other group received four doses, the first one being a double dose given on day 0 and than three other single doses on days 7, 20 and 35. The evaluation of humoral immune response was carried out by serum neutralization (SN) and indirect immunofluorescense (IIF) tests, while the cellular immune response was evaluated by lymphoblastic transformation assay (LTA) and skin test (ST). According to our results these reduced schedules elicited early and effective humoral and cellulafimmune responses to rabies antigen suggesting that new reduced schedules should be extensively studied in order to give the proper bases to the proposition of changes in the current long-term schedule.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study reports preliminary results of virus neutralizing antibody (VNA) titers obtained on different days in the course of human anti-rabies immunization with the 2-1-1 schedule (one dose is given in the right arm and one dose in the left arm at day 0, and one dose is apllied on days 7 and 21), recommended by WHO for post-exposure treatment with cell culture vaccines. A variant schedule (double dose on day zero and another on day 14) was also tested, both employing suckling mouse brain vaccine. A complete seroconversion rate was obtained after only 3 vaccine doses, and almost all patients (11 of 12) presented titers higher than 1.0 IU/ml. Both neutralizing response and seroconversion rates were lower in the group receiving only 3 doses, regardless of the sample collecting day. Although our results are lower than those found with cell culture vaccines, the geometry mean of VNA is fully satisfactory, overcoming the lower limit recommended by WHO of 0.5 IU/ml. The 2-1-1 schedule could be an alternative one for pre exposure immunization, shorter than the classical 3+1 regimen (one dose on days 0, 2, 4 and 30) with only three visits to the doctor, instead of four.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

From March 1991 to April 1992, serum samples for IgM detection were collected from 112 clinical measles cases reported to the Health Department of Niterói, State of Rio de Janeiro. The positivity exceeded 90% for specimens collected from the 5th to the 29th day after the onset of the disease. After day 30 a decline in IgM detection was observed, although positivity has been detected up to 90 days after the onset of the symptoms. Forty-four patients (48.9%) with an IgM response had a history of prior measles vaccination. In 5 of the 22 measles-IgM negative cases the infection was due to other agents (rubella: 4 cases, dengue: 1 case). These results show that sensitivity of the test employed for confirming suspected measles cases is high, even in vaccinated patients.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A clinical trial pilot study, double-blinded, randomized, and controlled with a placebo to assess the effectiveness of oral doxycycline (200 mg, single dose) in preventing leptospirosis after high exposure to potentially contamined water was performed in São Paulo, SP, Brazil. Confirmed cases were defined as those with leptospira IgM antibody and symptoms; asymptomatic cases were those presenting with IgM antibodies but no symptoms; and suspected cases were individuals with symptoms but no IgM antibody. Forty subjects were given doxycycline and 42 were given placebo. In the drug-treated group there were 2 confirmed cases, 11 asymptomatic cases, and 6 suspected cases. In the placebo group there were 5 confirmed, 6 symptomatic, and 5 suspected cases. Even though we found a protective association of doxycycline for confirmed leptospirosis cases (RR = 2.3) and seroconversion only (RR = 2.0), the association was not statistically significant because of the small number of individuals enrolled in this pilot study. We observed that the 22% of the volunteers already had IgM antibodies to leptospirosis at the first sampling. Finally, the attack rate to confirmed, asymptomatic, and suspected cases of Leptospirosis was 8.5%, 22%, and 13%, respectively, in this population.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Dissertation presented to obtain the PhD degree in Biology/Molecular Biology by Universidade Nova de Lisboa, Instituto de Tecnologia Química e Biológica

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Response to treatment with antimonial drugs varies considerably depending on the parasite strain involved, immune status of the patient and clinical form of the disease. Therapeutic regimens with this first line drug have been frequently modified both, in dose and duration of therapy. A regimen of 20 mg/kg/day of pentavalent antimony (Sb5+) during four weeks without an upper limit on the daily dose is currently recommended for mucosal disease ("espundia"). Side-effects with this dose are more marked in elderly patients, more commonly affected by this form of leishmaniasis. According to our experience, leishmaniasis in Rio de Janeiro responds well to antimony and, in cutaneous disease, high cure rates are obtained with 5 mg/kg/day of Sb5+ during 30 to 45-days. In this study a high rate of cure (91.4%) employing this dose was achieved in 36 patients with mild disease in this same geographic region. Side-effects were reduced and no antimony refractoriness was noted with subsequent use of larger dose in patients that failed to respond to initial schedule.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The clinical significance of isolated anti-HBc is still a challenge. To elucidate the real importance of this finding in our blood donors, an investigation algorithm was tested. One hundred and twelve isolated anti-HBc seropositive blood donors underwent clinical evaluation and retesting of HBV markers. Those who presented repeatedly reactive isolated anti-HBc, received a single dose of hepatitis B recombinant vaccine to verify anti-HBs early response. A HBV-DNA determination by PCR was done for those who did not test positive to anti-HBs after vaccine. The level of anti-HBc was recorded as a ratio of the sample-to-cut-off values (S:C ratio) in 57 candidates at donation. Comparing true and false-positive anti-HBc results, the different S:C ratios of them were statistically significant and when less than 2, implying in a false-positive result probability over 80%. A high percent of false-positive results (16.07%) was verified after anti-HBc retesting. HBV immunity was characterized in 49.11%, either by anti-HBs detection in retesting (15.18%), or after a single dose HBV vaccination (33.93%). HBV-DNA was negative in all tested donors. In conclusion, this algorithm was useful to clarify the meaning of isolated anti-HBc in most of our blood donors.