973 resultados para fluorescein angiography
Resumo:
Coronary angiography can be a high-risk condition for the incidence of contrast-induced nephropathy (CIN) in elderly patients. Reduced glutathione, under a variety of mechanisms, may prevent CIN in this procedure. We prospectively examined whether hydration with reduced glutathione is superior to hydration alone for prevention of CIN in an elderly Han Chinese population. A total of 505 patients (271 males and 234 females) aged 75 years or older who underwent non-emergency coronary angiography or an intervention were randomly divided into two groups. The treatment group received hydration with reduced glutathione (n=262) and the control group received hydration alone (n=243). Serum creatinine and blood urea nitrogen levels were measured prior to coronary angiography and 48 h after this procedure. The primary endpoint was occurrence of CIN, which was defined as 25% or 44.2 µmol/L above baseline serum creatinine levels 48 h after the procedure. The overall incidence of CIN was 6.49% in the treatment group and 7.41% in the control group, with no significant difference between the groups (P=0.68). In subgroup analysis by percutaneous coronary intervention, no significant differences were found between the two groups. In summary, reduced glutathione added to optimal hydration does not further decrease the risk of CIN in elderly patients undergoing coronary angiography or an intervention.
Resumo:
Overcoming the natural defensive barrier functions of the eye remains one of the greatest challenges of ocular drug delivery. Cornea is a chemical and mechanical barrier preventing the passage of any foreign bodies including drugs into the eye, but the factors limiting penetration of permeants and nanoparticulate drug delivery systems through the cornea are still not fully understood. In this study, we investigate these barrier properties of the cornea using thiolated and PEGylated (750 and 5000 Da) nanoparticles, sodium fluorescein, and two linear polymers (dextran and polyethylene glycol). Experiments used intact bovine cornea in addition to bovine cornea de-epithelialized or tissues pretreated with cyclodextrin. It was shown that corneal epithelium is the major barrier for permeation; pretreatment of the cornea with β-cyclodextrin provides higher permeation of low molecular weight compounds, such as sodium fluorescein, but does not enhance penetration of nanoparticles and larger molecules. Studying penetration of thiolated and PEGylated (750 and 5000 Da) nanoparticles into the de-epithelialized ocular tissue revealed that interactions between corneal surface and thiol groups of nanoparticles were more significant determinants of penetration than particle size (for the sizes used here). PEGylation with polyethylene glycol of a higher molecular weight (5000 Da) allows penetration of nanoparticles into the stroma, which proceeds gradually, after an initial 1 h lag phase.
Resumo:
Molecular methods that permit the simultaneous detection and quantification of a large number of microbial species are currently employed in the evaluation of complex ecosystems. The checkerboard DNA-DNA hybridization technique enables the simultaneous identification of distinct bacterial. species in a large number of dental samples. The original technique employed digoxigenin-labeled whole genomic DNA probes which were detected by chemiluminescence. In this study, we present an alternative protocol for labeling and detecting whole genomic DNA probes in the Checkerboard DNA-DNA hybridization method. Whole genomic DNA was extracted from five bacterial species and labeled with fluorescein. The fluorescein labeled whole genomic DNA probes were hybridized against whole genomic DNA or subgingival plaque samples in a checkerboard hybridization format, followed by chemiluminescent detection. Our results reveal that fluorescein is a viable and adequate alternative labeling reagent to be employed in the checkerboard DNA-DNA hybridization technique. (c) 2007 Elsevier GmbH. All rights reserved.
Resumo:
A combined and sequential Monte Carlo-quantum mechanics methodology is used to describe the electronic absorption spectrum of the fluorescein dianion in water. Different sets of 100 statistically relevant configurations composed of the solute and several solvent molecules are sampled from the Monte Carlo simulation for a posteriori quantum mechanical calculations of the spectra. In the largest case the configurations are composed of fluorescein and 90 explicit water molecules embedded in the electrostatic field of all remaining water molecules within a distance of 11.3 angstrom. These configurations include 305 atoms and 842 valence electrons, justifying the use of a semi-empirical approach. The electronic spectrum is then calculated using the INDO/CIS method. The solvatochromic shift of fluorescein in water, compared with in isolation, is calculated using the discrete and explicit solvent models. The use of electrostatically embedded explicit water molecules, in INDO/CIS calculations, gives a good description of the spectral shift of the fluorescein dianion in aqueous environment. The results are verified to converge both statistically and with respect to the number of explicit solvent molecules used.
Resumo:
The increase in aquaculture global fish production has been associated with an increase in infectious diseases affecting aquacultured species.. The aim of this study was to identify ulcers in pacu (Piaractus mesopotamicus) with sodium fluorescein before it was possible to observe them visually. Twenty one fish with no apparent skin lesions were divided into three groups. Group 1 were injected with saline 0.65% (Group 1), Group 2 with 6 x 10(8) CFU of Aeromonas hydrophila and group 3 with 6 x 10(8) CFU of Streptococcus agalactiae into the peritoneal cavity. All animals showed a positive reaction to fluorescein. A. hydrophila infected fish presented with large round marks with irregular borders, the characteristic ulcers caused by this agent. However, the other groups only displayed markings associated with handling caused by the netting procedures. We concluded that sodium fluorescein may be useful for an early and fast evaluation of cutaneous infection of A. hydrophila in pacu.
Resumo:
Background-It remains uncertain whether acetylcysteine prevents contrast-induced acute kidney injury. Methods and Results-We randomly assigned 2308 patients undergoing an intravascular angiographic procedure with at least 1 risk factor for contrast-induced acute kidney injury (age >70 years, renal failure, diabetes mellitus, heart failure, or hypotension) to acetylcysteine 1200 mg or placebo. The study drugs were administered orally twice daily for 2 doses before and 2 doses after the procedure. The allocation was concealed (central Web-based randomization). All analysis followed the intention-to-treat principle. The incidence of contrast-induced acute kidney injury (primary end point) was 12.7% in the acetylcysteine group and 12.7% in the control group (relative risk, 1.00; 95% confidence interval, 0.81 to 1.25; P = 0.97). A combined end point of mortality or need for dialysis at 30 days was also similar in both groups (2.2% and 2.3%, respectively; hazard ratio, 0.97; 95% confidence interval, 0.56 to 1.69; P = 0.92). Consistent effects were observed in all subgroups analyzed, including those with renal impairment. Conclusions-In this large randomized trial, we found that acetylcysteine does not reduce the risk of contrast-induced acute kidney injury or other clinically relevant outcomes in at-risk patients undergoing coronary and peripheral vascular angiography.
Resumo:
BACKGROUND: Because of their similar visual appearance, differentiation of left ventricular thrombotic material and myocardial wall can be difficult in contrast-enhanced coronary computed tomography (CT) angiography. OBJECTIVE: We identified typical thrombi attenuation of left ventricular thrombi with the use of CT measurement. METHODS: Over a time period of 6 years; we retrospectively identified 31 patients who showed a left ventricular thrombus in CT angiography datasets. Patients underwent routine contrast cardiac CT to investigate coronary artery disease. CT attenuation of each thrombus was assessed in the 4-chamber view. CT densities were also determined in the ascending aorta, left ventricle, and myocardial wall both in the mid-septal and mid-lateral segments. The mean CT attenuation of thrombi and the difference between attenuation in thrombi, left ventricular cavity, and myocardial wall were determined. The ratio of attenuation values in thrombus versus aorta and myocardium versus aorta were also determined. RESULTS: Mean (+/- SD) CT attenuation of all left ventricular thrombi in 31 patients was 43.2 +/- 15.3 HU (range, 25-80 HU). Mean CT densities of septal and lateral myocardial wall were 102.9 +/- 23.1 HU (range, 63-155 HU) and 99.3 +/- 28.7 HU (range, 72-191 HU), respectively, and were thus significantly higher than the CT attenuation of thrombi (P < 0.001). A threshold of 65 HU yielded a sensitivity, specificity, and positive and negative predictive values of 94%, 97%, 94%, and 97%, respectively, to differentiate thrombus from the myocardial wall. The mean ratio between CT attenuation of thrombus and CT attenuation within the ascending aorta was 0.11 +/- 0.05 (range, 0.04-0.23), which was significantly lower compared with the mean ratio between CT attenuation of the myocardial wall and the CT attenuation within the ascending aorta. CONCLUSION: CT attenuation within left ventricular thrombi was significantly lower than myocardial attenuation in CT angiography datasets. Assessment of CT attenuation may contribute to the differentiation of thrombi. (C) 2012 Society of Cardiovascular Computed Tomography. All rights reserved.
Resumo:
Semi-quantitative stenosis assessment by coronary CT angiography only modestly predicts stress-induced myocardial perfusion abnormalities. The performance of quantitative CT angiography (QCTA) for identifying patients with myocardial perfusion defects remains unclear. CorE-64 is a multicenter, international study to assess the accuracy of 64-slice QCTA for detecting a parts per thousand yen50% coronary arterial stenoses by quantitative coronary angiography (QCA). Patients referred for cardiac catheterization with suspected or known coronary artery disease were enrolled. Area under the receiver-operating-characteristic curve (AUC) was used to evaluate the diagnostic accuracy of the most severe coronary artery stenosis in a subset of 63 patients assessed by QCTA and QCA for detecting myocardial perfusion abnormalities on exercise or pharmacologic stress SPECT. Diagnostic accuracy of QCTA for identifying patients with myocardial perfusion abnormalities by SPECT revealed an AUC of 0.71, compared to 0.72 by QCA (P = .75). AUC did not improve after excluding studies with fixed myocardial perfusion abnormalities and total coronary arterial occlusions. Optimal stenosis threshold for QCTA was 43% yielding a sensitivity of 0.81 and specificity of 0.50, respectively, compared to 0.75 and 0.69 by QCA at a threshold of 59%. Sensitivity and specificity of QCTA to identify patients with both obstructive lesions and myocardial perfusion defects were 0.94 and 0.77, respectively. Coronary artery stenosis assessment by QCTA or QCA only modestly predicts the presence and the absence of myocardial perfusion abnormalities by SPECT. Confounding variables affecting the relationship between coronary anatomy and myocardial perfusion likely account for some of the observed discrepancies between coronary angiography and SPECT results.
Resumo:
Objectives: Cocaine is a commonly used illicit drug that leads to the most emergency department (ED) visits. Chest pain is the most common presentation, reported in 40% of patients. Our aim was to evaluate the incidence of previous myocardial infarction among young cocaine users (18-40 years) with cocaine-associated chest pain by the assessment of myocardial fibrosis by cardiovascular MRI. Second, we also intended to evaluate the coronary tree by CT angiography (CTA). Methods: 24 cocaine users (22 males) who frequently complained about cocaine-associated chest pain underwent CTA and cardiovascular MRI. Mean age of patients was 29.7 years and most of them (79%) had frequently used inhalatory cocaine. Results: The calcium score turned out to be positive in only one patient (Agatston=54). Among the coronary segments evaluated, only one patient had calcified plaques at the anterior descending coronary artery (proximal and medium segments). Assessment of regional ventricular function by the evaluation of 17 segments was normal in all patients. None of the patients showed myocardial delayed enhancement, indicative of myocardial fibrosis. CTA therefore confirmed the low cardiovascular risk of these patients, since most of them (96%) had no atherosclerosis detected by this examination. Only one patient (4%) had coronary atherosclerosis detected, without significant coronary stenosis. Conclusion: Cardiovascular MR did not detect the presence of delayed enhancement indicative of myocardial fibrosis among young cocaine users with low cardiovascular risk who had complained of cocaine-associated chest pain.
Resumo:
Objectives: Previous evidence supports a direct relationship between the calcium burden (volume) on post-contrast CT with the percent internal carotid artery (ICA) stenosis at the carotid bifurcation. We sought to further investigate this relationship by comparing non-enhanced CT (NECT) and digital subtraction angiography (DSA). Methods: 50 patients (aged 41-82 years) were retrospectively identified who had undergone cervical NECT and DSA. A 64-multidetector array CT (MDCT) scanner was utilised and the images reviewed using preset window widths/levels (30/300) optimised to calcium, with the volumes measured via three-dimensional reconstructive software. Stenosis measurements were performed on DSA and luminal diameter stenoses >40% were considered "significant". Volume thresholds of 0.01, 0.03, 0.06, 0.09 and 0.12 cm(3) were utilised and Pearson's correlation coefficient (r) was calculated to correlate the calcium volume with percent stenosis. Results: Of 100 carotid bifurcations, 88 were available and of these 7 were significantly stenotic. The NECT calcium volume moderately correlated with percent stenosis on DSA r=0.53 (p<0.01). A moderate-strong correlation was found between the square root of calcium volume on NECT with percent stenosis on DSA (r=0.60, p<0.01). Via a receiver operating characteristic curve, 0.06 cm(3) was determined to be the best threshold (sensitivity 100%, specificity 90.1%, negative predictive value 100% and positive predictive value 46.7%) for detecting significant stenoses. Conclusion: This preliminary investigation confirms a correlation between carotid bifurcation calcium volume and percent ICA stenosis and is promising for the optimal threshold for stenosis detection. Future studies could utilise calcium volumes to create a "score" that could predict high grade stenosis.
Resumo:
Background: Performing a coronary angiography in patients with heart failure of unknown etiology is often justified by the diagnostic assessment of ischemic heart disease. However, the clinical benefit of this strategy is not known. Objective: To evaluate the prevalence of ischemic heart disease by angiographic criteria in patients with heart failure and reduced ejection fraction of unknown etiology, as well as its impact on therapy decisions. Methods: Consecutive outpatients with heart failure and systolic dysfunction, who had an indication for coronary angiography to clarify the etiology of heart disease were assessed from 1 January 2009 to December 31, 2010. Patients diagnosed with coronary artery disease, positive serology for Chagas disease, congenital heart disease, valve disease or patients undergoing cardiac transplantation were excluded from the analysis. The sample was divided into two groups according to the indication for catheterization. Group-1: Symptomatic due to angina or heart failure. Group-2: Presence of >= 2 risk factors for coronary artery disease Results: One hundred and seven patients were included in the analysis, with 51 (47.7%) patients in Group 1 and 56 (52.3%) in Group 2. The prevalence of ischemic heart disease was 9.3% (10 patients), and all belonged to Group 1 (p = 0.0001). During follow-up, only 4 (3.7%) were referred for CABG; 3 (2.8%) patients had procedure-related complications. Conclusion: In our study, coronary angiography in patients with heart failure and systolic dysfunction of unknown etiology, although supported by current guidelines, did not show benefits when performed only due to the presence of risk factors for coronary artery disease. (Arq Bras Cardiol 2012;98(5):437-441)
Resumo:
There are no studies investigating the effect of the contrast infusion on the sensitivity and specificity of the main Doppler criteria of renal artery stenosis (RAS). Our aim was to evaluate the accuracy of these Doppler criteria prior to and following the intravenous administration of perfluorocarbon exposed sonicated albumin (PESDA) in patients suspected of having RAS. Thirty consecutive hypertensive patients (13 males, mean age of 57 ± 10 years) suspected of having RAS by clinical clues, were submitted to ultrasonography (US) of renal arteries before and after enhancement using continuous infusion of PESDA. All patients underwent angiography, and haemodynamically significant RAS was considered when ≥50%. At angiography, it was detected RAS ≥50% in 18 patients, 5 with bilateral stenosis. After contrast, the examination time was slightly reduced by approximately 20%. In non-enhanced US the sensitivity was better when based on resistance index (82.9%) while the specificity was better when based on renal aortic ratio (89.2%). The predictive positive value was stable for all indexes (74.0%–88.0%) while negative predictive value was low (44%–51%). The specificity and positive predictive value based on renal aortic ratio increased after PESDA injection respectively, from 89 to 97.3% and from 88 to 95%. In hypertensives suspected to have RAS the sensitivity and specificity of Duplex US is dependent of the criterion evaluated. Enhancement with continuous infusion of PESDA improves only the specificity based on renal aortic ratio but do not modify the sensitivity of any index.
Resumo:
Lo scopo di questa tesi è lo studio degli aspetti procedurali e dosimetrici in angiografie periferiche che utilizzano la CO2 come mezzo di contrasto. La tecnica angiografica consiste nell’imaging radiologico di vasi sanguigni tramite l’iniezione di un mezzo di contrasto, e il suo uso è in costante incremento a causa dell’aumento di pazienti con malattie vascolari. I mezzi di contrasto iodati sono i più comunemente utilizzati e permettono di ottenere immagini di ottima qualità, ma presentano il limite di una elevata nefrotossicità. La CO2 è considerata un’interessante alternativa al mezzo iodato, per la sua acclarata biocompatibilità, soprattutto per pazienti con elevati fattori di rischio (diabete e/o insufficienza renale). Il suo utilizzo presenta comunque alcuni aspetti problematici, dovuti allo stato gassoso e al basso contrasto intrinseco rispetto alla soluzione iodata. Per quest’ultimo motivo si ritiene generalmente che l’utilizzo della CO2 comporti un aumento di dose rispetto ai mezzi di contrasto tradizionali. Il nostro studio, effettuato su diversi apparati radiologici, ha dimostrato che i parametri di emissione radiologica sono gli stessi per i protocolli di angiografia tradizionale, con iodio, e quelli che utilizzano CO2. Questa evidenza suggerisce che i protocolli CO2 operino solo sul trattamento delle immagini ottenute e non sulla modalità di acquisizione, e dal punto di vista dosimetrico l’angiografia con CO2 è riconducibile all’angiografia tradizionale. L’unico fattore che potrebbe portare a un effettivo incremento di dose al paziente è un allungamento dei tempi di scopia e di procedura, che andrebbe verificato con una campagna di misure in ambito clinico. Sulla base della stessa evidenza, si ritiene che la visualizzazione della CO2 possa essere ulteriormente migliorata attraverso l’ottimizzazione dei parametri di emissione radiologica (kVp, frame rate e durata degli impulsi) attualmente predisposti per l’uso di mezzi di contrasto iodati.