894 resultados para exploitation of the testing


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The development of a new product or a new process, if adopted by the market, may generate a number of economic processes including secondary innovations to promote the exploitation of the new discovery. Such technological advances may also promote new industrial ventures which may exist over many decades, enhancing economic development. The history of the adoption of the cyanide process for the extraction of gold from its ores exemplifies such developments. One outcome was the formation of an international cyanide cartel.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This case study represents four years of audiological observations, testing and aural habilitation of a female child with a partial agenesis of the corpus callosum (ACC). The ACC was diagnosed by MRI scans to eliminate neurological causes for developmental delay at six months of age. This child was also born with a cleft palate and was diagnosed with Robinow Syndrome at 3 years and 3 months of age. The audiological results showed an improvement in hearing thresholds over the four-year period. The child’s opthamologist also reported an improvement in visual skills over time. The most interesting aspect of the child’s hearing was the discrepancy between the monaural and the binaural results. That is, when assessed binaurally she often presented with a mild to moderate mixed loss and when assessed monaurally she showed a moderate to severe mixed loss for the right ear and a severe mixed loss for the left ear. This discrepancy between binaural and monaural results was evident for both aided and unaided tests. Parental reports of the child’s hearing were consistent with the binaural clinical results. This case indicates the need for audiologists to: (a) carefully monitor the hearing of children with ACC, (b) obtain monaural and binaural hearing and aided thresholds results, and (c) compare these children’s functional abilities to the objective test results obtained. This case does question whether hearing aids are appropriate for children with ACC. If hearing aids are deemed to be appropriate, then hearing aids with compression characteristics should be considered.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This case study presents four and a half years of audiological observations, testing and aural habilitation of a female child with a partial agenesis of the corpus callosum (ACC). The ACC was diagnosed by MRI scan performed at 6 months of age to eliminate neurological causes for the developmental delay. This child was also born with a cleft palate and was diagnosed with Robinow Syndrome at 3 years and 3 months of age. The audiological results showed an improvement in hearing thresholds over the 4-year period. The child’s ophthalmologist also reported an improvement in visual skills over time. The most interesting aspect of the child’s hearing was the discrepancy between the monaural and the binaural results. That is, when assessed binaurally she often presented with a mild to moderate mixed loss and, when assessed monaurally, she showed a moderate to severe mixed loss for the right ear and a severe mixed loss for the left ear. Over time, the discrepancy between the monaural and binaural results changed. When assessed binaurally, the loss decreased to normal low frequency hearing sloping to a mild high frequency loss. When assessed monaurally, the most recent results showed a mild loss for the right ear and a moderate loss for the left ear. This discrepancy between binaural and monaural results was evident for both aided and unaided tests. For the most recent thresholds, the binaural results were consistent with the right monaural thresholds for the first time over the four and a half years. Parental reports of the child’s hearing were consistent with the binaural clinical results. This case indicates the need for audiologists to (1) carefully monitor the hearing of children with ACC, (2) obtain monaural and binaural hearing and aided thresholds results, and (3) compare these children’s functional abilities with the objective test results obtained. This case does question whether hearing aids are appropriate for children with ACC. If hearing aids are deemed to be appropriate, then hearing aids with compression characteristics should be considered.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To develop a reliable, valid, and responsive self-administered questionnaire to probe pain, stiffness and physical disability in patients with osteoarthritis (OA) of the hand. Design: In order to assess the dimensionality of the symptomatology of hand OA, a self-administered questionnaire was developed to probe various aspects of pain (10 items), stiffness (two items), and physical function (83 items). The question inventory was generated from eight existing health status measures and an interactive process involving four rheumatologists, two physiotherapists, and an orthopaedic surgeon. Results: Face-to-face interviews were conducted with 50 OA hand patients; 39 females and 11 males with mean age 62.8 years and mean disease duration 9.4 years. Items retained were those which fulfilled specified selection criteria: prevalence greater than or equal to60% and mean importance score approximating or exceeding 2.0 Item exclusion criteria included low prevalence, gender-based, ambiguous, duplicates or similarities, alternatives, composite items, and items that were too restrictive. This process resulted in five pain, one stiffness and nine function items which have been proposed for incorporation in the AUSCAN Index. Conclusions: Using a traditional development strategy, we have constructed a self-administered multi-dimensional outcome measure for assessing hand OA. The next stage includes reliability, validity and responsiveness testing of the 15-item questionnaire. (C) 2002 OsteoArthritis Research Society Intenational. Published by Elsevier Science Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The tests that are currently available for the measurement of overexpression of the human epidermal growth factor-2 (HER2) in breast cancer have shown considerable problems in accuracy and interlaboratory reproducibility. Although these problems are partly alleviated by the use of validated, standardised 'kits', there may be considerable cost involved in their use. Prior to testing it may therefore be an advantage to be able to predict from basic pathology data whether a cancer is likely to overexpress HER2. In this study, we have correlated pathology features of cancers with the frequency of HER2 overexpression assessed by immunohistochemistry (IHC) using HercepTest (Dako). In addition, fluorescence in situ hybridisation (FISH) has been used to re-test the equivocal cancers and interobserver variation in assessing HER2 overexpression has been examined by a slide circulation scheme. Of the 1536 cancers, 1144 (74.5%) did not overexpress HER2. Unequivocal overexpression (3+ by IHC) was seen in 186 cancers (12%) and an equivocal result (2+ by IHC) was seen in 206 cancers (13%). Of the 156 IHC 3+ cancers for which complete data was available, 149 (95.5%) were ductal NST and 152 (97%) were histological grade 2 or 3. Only 1 of 124 infiltrating lobular carcinomas (0.8%) showed HER2 overexpression. None of the 49 'special types' of carcinoma showed HER2 overexpression. Re-testing by FISH of a proportion of the IHC 2+ cancers showed that only 25 (23%) of those assessable exhibited HER2 gene amplification, but 46 of the 47 IHC 3+ cancers (98%) were confirmed as showing gene amplification. Circulating slides for the assessment of HER2 score showed a moderate level of agreement between pathologists (kappa 0.4). As a result of this study we would advocate consideration of a triage approach to HER-2 testing. Infiltrating lobular and special types of carcinoma may not need to be routinely tested at presentation nor may grade 1 NST carcinomas in which only 1.4% have been shown to overexpress HER2. Testing of these carcinomas may be performed when HER2 status is required to assist in therapeutic or other clinical/prognostic decision-making. The highest yield of HER2 overexpressing carcinomas is seen in the grade 3 NST subgroup in which 24% are positive by IHC. (C) 2003 Elsevier Science Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: The aim of the present study was to investigate the between-days reliability of electromyographic (EMG) measurement of 6 bilateral trunk muscles and also the torque output in 3 planes during isometric right and left axial rotation at different exertion levels. Methods: Ten healthy subjects performed isometric right and left axial rotation at 100, 70, 50 and 30% maximum voluntary contractions in two testing sessions at least 7 days apart. EMG amplitude and frequency analyses of the recorded surface EMG signals were performed for rectus abdominis, external oblique, internal oblique, latissimus dorsi, iliocostalis lumborum and multifidus bilaterally. The primary torque in the transverse plane and the coupling torques in sagittal and coronal planes were measured. Results: For both EMG amplitude and frequency values, good (intraclass correlation coefficient, ICC = 0.75-0.89) to excellent (ICC greater than or equal to 0.90) reliability was found in the 6 trunk muscles at different exertion levels during axial rotation. The reliability of both maximal isometric axial rotation torque and coupling torques in sagittal and coronal planes were found to be excellent (ICC greater than or equal to 0.93). Conclusions: Good to excellent reliability of EMG measures of trunk muscles and torque measurements during isometric axial rotation was demonstrated. This provides further confidence of using EMG and triaxial torque assessment as outcome measures in rehabilitation and in the evaluation of the human performance in the work place. (C) 2003 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE: Analyze the infectivity and storage resistance of cysts of the ME-49 strain of Toxoplasma gondii in artificially infected bovine milk and homemade fresh cheese. METHODS: Pasteurized bovine milk was infected with 10 cysts/ml of the ME-49 strain of T.gondii and inoculated in different groups of mice, immediately or after storage at 4ºC for 5, 10 and 20 days. Homemade fresh cheese was prepared with artificially infected milk, and also tested in groups of mice, using the same storage process. Infection was identified by the presence of cysts in the brain or serological testing in challenged mice after 5 weeks, confirmed by Western Blot and histology. RESULTS: The infectivity of cysts of the ME-49 strain of T.gondii was maintained in the milk even after storage for 20 days at refrigerator temperatures. Cysts were also able to survive the production process of homemade fresh cheese and storage for a period of 10 days in the same conditions. CONCLUSIONS: These data demonstrated that milk and dairy products could be an important source of T.gondii in human contamination, reinforcing the importance of milk pasteurization before any processing or ingestion.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The rapid growth in genetics and molecular biology combined with the development of techniques for genetically engineering small animals has led to increased interest in in vivo small animal imaging. Small animal imaging has been applied frequently to the imaging of small animals (mice and rats), which are ubiquitous in modeling human diseases and testing treatments. The use of PET in small animals allows the use of subjects as their own control, reducing the interanimal variability. This allows performing longitudinal studies on the same animal and improves the accuracy of biological models. However, small animal PET still suffers from several limitations. The amounts of radiotracers needed, limited scanner sensitivity, image resolution and image quantification issues, all could clearly benefit from additional research. Because nuclear medicine imaging deals with radioactive decay, the emission of radiation energy through photons and particles alongside with the detection of these quanta and particles in different materials make Monte Carlo method an important simulation tool in both nuclear medicine research and clinical practice. In order to optimize the quantitative use of PET in clinical practice, data- and image-processing methods are also a field of intense interest and development. The evaluation of such methods often relies on the use of simulated data and images since these offer control of the ground truth. Monte Carlo simulations are widely used for PET simulation since they take into account all the random processes involved in PET imaging, from the emission of the positron to the detection of the photons by the detectors. Simulation techniques have become an importance and indispensable complement to a wide range of problems that could not be addressed by experimental or analytical approaches.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Dissertação de Mestrado, Estudos Integrados dos Oceanos, 25 de Julho 2013, Universidade dos Açores.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Following work on tantalum and chromium implanted flat M50 steel substrates, this work reports on the electrochemical behaviour of M50 steel implanted with tantalum and chromium and the effect of the angle of incidence. Proposed optimum doses for resistance to chloride attack were based on the interpretation of results obtained during long-term and accelerated electrochemical testing. After dose optimization from the corrosion viewpoint, substrates were implanted at different angles of incidence (15°, 30°, 45°, 60°, 75°, 90°) and their susceptibility to localized corrosion assessed using open-circuit measurements, step by step polarization and cyclic voltammetry at several scan rates (5–50 mV s-1). Results showed, for tantalum implanted samples, an ennoblement of the pitting potential of approximately 0.5 V for an angle of incidence of 90°. A retained dose of 5 × 1016 atoms cm-2 was found by depth profiling with Rutherford backscattering spectrometry. The retained dose decreases rapidly with angle of incidence. The breakdown potential varies roughly linearly with the angle of incidence up to 30° falling fast to reach -0.1 V (vs. a saturated calomel electrode (SCE)) for 15°. Chromium was found to behave differently. Maximum corrosion resistance was found for angles of 45°–60° according to current densities and breakdown potentials. Cr+ depth profiles ((p,γ) resonance broadening method), showed that retained doses up to an angle of 60° did not change much from the implanted dose at 90°, 2 × 1017 Cr atoms cm-2. The retained implantation dose for tantalum and chromium was found to follow a (cos θ)8/3 dependence where θ is the angle between the sample normal and the beam direction.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

GOAL: The manufacturing and distribution of strips of instant thin - layer chromatography with silica gel (ITLC - SG) (reference method) is currently discontinued so there is a need for an alternative method f or the determination of radiochemical purity (RCP) of 99m Tc - tetrofosmin. This study aims to compare five alternative methods proposed by the producer to determine the RCP of 99m Tc - tetrofosmin. METHODS: Nineteen vials of tetrofosmin were radiolabelled with 99m Tc and the percentages of the RCP were determined. Five different methods were compared with the standard RCP testing method (ITLC - SG, 2x20 cm): Whatman 3MM (1x10 cm) with acetone and dichloro - methane (method 1); Whatman 3MM (1x1 0 cm) with ethyl acetate (method 2); aluminum oxide - coated plastic thin - layer chromatography (TLC) plate (1x10 cm) and ethanol (method 3); Whatman 3MM (2x20 cm) with acetone and dichloro - methane (method 4); solid - phase extraction method C18 cartridge (meth od 5). RESULTS: The average values of RCP were 95,30% ± 1,28% (method 1), 93,95 ± 0,61% (method 2), 96,85% ± 0,93% (method 3), 92,94% ± 0,99% (method 4) and 96,25% ± 2,57% (method 5) (n=12 each), and 93,15% ± 1,13% for the standard method (n=19). There we re statistical significant differences in the values obtained for methods 1 (P=0,001), 3 (P=0,000) and 5 (P=0,004), and there were no statistical significant differences in the values obtained for methods 2 (P=0,113) and 4 (P=0,327). CONCLUSION: From the results obtained, methods 2 and 4 showed a higher correlation with the standard method. Unlike method 4, method 2 is less time - consuming than the reference method and can overcome the problems associated with the solvent toxicity. The remaining methods (1, 3 and 5) tended to overestimate RCP value compared to the standard method.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVE To evaluate the cross-cultural validity of the Demand-Control Questionnaire, comparing the original Swedish questionnaire with the Brazilian version. METHODS We compared data from 362 Swedish and 399 Brazilian health workers. Confirmatory and exploratory factor analyses were performed to test structural validity, using the robust weighted least squares mean and variance-adjusted (WLSMV) estimator. Construct validity, using hypotheses testing, was evaluated through the inspection of the mean score distribution of the scale dimensions according to sociodemographic and social support at work variables. RESULTS The confirmatory and exploratory factor analyses supported the instrument in three dimensions (for Swedish and Brazilians): psychological demands, skill discretion and decision authority. The best-fit model was achieved by including an error correlation between work fast and work intensely (psychological demands) and removing the item repetitive work (skill discretion). Hypotheses testing showed that workers with university degree had higher scores on skill discretion and decision authority and those with high levels of Social Support at Work had lower scores on psychological demands and higher scores on decision authority. CONCLUSIONS The results supported the equivalent dimensional structures across the two culturally different work contexts. Skill discretion and decision authority formed two distinct dimensions and the item repetitive work should be removed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The performance of the Weather Research and Forecast (WRF) model in wind simulation was evaluated under different numerical and physical options for an area of Portugal, located in complex terrain and characterized by its significant wind energy resource. The grid nudging and integration time of the simulations were the tested numerical options. Since the goal is to simulate the near-surface wind, the physical parameterization schemes regarding the boundary layer were the ones under evaluation. Also, the influences of the local terrain complexity and simulation domain resolution on the model results were also studied. Data from three wind measuring stations located within the chosen area were compared with the model results, in terms of Root Mean Square Error, Standard Deviation Error and Bias. Wind speed histograms, occurrences and energy wind roses were also used for model evaluation. Globally, the model accurately reproduced the local wind regime, despite a significant underestimation of the wind speed. The wind direction is reasonably simulated by the model especially in wind regimes where there is a clear dominant sector, but in the presence of low wind speeds the characterization of the wind direction (observed and simulated) is very subjective and led to higher deviations between simulations and observations. Within the tested options, results show that the use of grid nudging in simulations that should not exceed an integration time of 2 days is the best numerical configuration, and the parameterization set composed by the physical schemes MM5–Yonsei University–Noah are the most suitable for this site. Results were poorer in sites with higher terrain complexity, mainly due to limitations of the terrain data supplied to the model. The increase of the simulation domain resolution alone is not enough to significantly improve the model performance. Results suggest that error minimization in the wind simulation can be achieved by testing and choosing a suitable numerical and physical configuration for the region of interest together with the use of high resolution terrain data, if available.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Aspergillus fumigatus (Af) and Pseudomonas aeruginosa (Pa) are leading fungal and bacterial pathogens, respectively, in many clinical situations. Relevant to this, their interface and co-existence has been studied. In some experiments in vitro, Pa products have been defined that are inhibitory to Af. In some clinical situations, both can be biofilm producers, and biofilm could alter their physiology and affect their interaction. That may be most relevant to airways in cystic fibrosis (CF), where both are often prominent residents. We have studied clinical Pa isolates from several sources for their effects on Af, including testing involving their biofilms. We show that the described inhibition of Af is related to the source and phenotype of the Pa isolate. Pa cells inhibited the growth and formation of Af biofilm from conidia, with CF isolates more inhibitory than non-CF isolates, and non-mucoid CF isolates most inhibitory. Inhibition did not require live Pa contact, as culture filtrates were also inhibitory, and again non-mucoid>mucoid CF>non-CF. Preformed Af biofilm was more resistant to Pa, and inhibition that occurred could be reproduced with filtrates. Inhibition of Af biofilm appears also dependent on bacterial growth conditions; filtrates from Pa grown as biofilm were more inhibitory than from Pa grown planktonically. The differences in Pa shown from these different sources are consistent with the extensive evolutionary Pa changes that have been described in association with chronic residence in CF airways, and may reflect adaptive changes to life in a polymicrobial environment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper proposes an online mechanism that can evaluate the sensitivity of single event upsets (SEUs) of field programmable gate arrays (FPGAs). The online detection mechanism cyclically reads and compares the values form the external and internal configuration memories, taking into account the mask information. This remote detection method also signals any mismatch as a result of a SEU that affects both used and not-used FPGA parts, which maximizes the monitored area. By utilizing an external, Web-accessible controller that is connected to the test infrastructure, the possibility of running the same operation in a remote manner is enabled. Moreover, the need for a local memory to store the mask values is also eliminated.