989 resultados para dubbelexamen, double degree, tuplatutkinto, motivation, universitetsstuderande
Resumo:
Adhesive bonding as a joining or repair method has a wide application in many industries. Repairs with bonded patches are often carried out to re-establish the stiffness at critical regions or spots of corrosion and/or fatigue cracks. Single and double-strap repairs (SS and DS, respectively) are a viable option for repairing. For the SS repairs, a patch is adhesively-bonded on one of the structure faces. SS repairs are easy to execute, but the load eccentricity leads to peel peak stresses at the overlap edges. DS repairs involve the use of two patches, one on each face of the structure. These are more efficient than SS repairs, due to the doubling of the bonding area and suppression of the transverse deflection of the adherends. Shear stresses also become more uniform as a result of smaller differential straining. The experimental and Finite Element (FE) study presented here for strength prediction and design optimization of bonded repairs includes SS and DS solutions with different values of overlap length (LO). The examined values of LO include 10, 20 and 30 mm. The failure strengths of the SS and DS repairs were compared with FE results by using the Abaqus® FE software. A Cohesive Zone Model (CZM) with a triangular shape in pure tensile and shear modes, including the mixed-mode possibility for crack growth, was used to simulate fracture of the adhesive layer. A good agreement was found between the experiments and the FE simulations on the failure modes, elastic stiffness and strength of the repairs, showing the effectiveness and applicability of the proposed FE technique in predicting strength of bonded repairs. Furthermore, some optimization principles were proposed to repair structures with adhesively-bonded patches that will allow repair designers to effectively design bonded repairs.
Resumo:
This work reports on an experimental and finite element method (FEM) parametric study of adhesively-bonded single and double-strap repairs on carbon-epoxy structures under buckling unrestrained compression. The influence of the overlap length and patch thickness was evaluated. This loading gains a particular significance from the additional characteristic mechanisms of structures under compression, such as fibres microbuckling, for buckling restrained structures, or global buckling of the assembly, if no transverse restriction exists. The FEM analysis is based on the use of cohesive elements including mixed-mode criteria to simulate a cohesive fracture of the adhesive layer. Trapezoidal laws in pure modes I and II were used to account for the ductility of most structural adhesives. These laws were estimated for the adhesive used from double cantilever beam (DCB) and end-notched flexure (ENF) tests, respectively, using an inverse technique. The pure mode III cohesive law was equalled to the pure mode II one. Compression failure in the laminates was predicted using a stress-based criterion. The accurate FEM predictions open a good prospect for the reduction of the extensive experimentation in the design of carbon-epoxy repairs. Design principles were also established for these repairs under buckling.
Resumo:
In this work, an experimental study was performed on the influence of plug filling, loading rate and temperature on the tensile strength of single-strap (SS) and double-strap (DS) repairs on aluminium structures. The experimental programme includes repairs with different values of overlap length (LO=10, 20 and 30 mm), and with and without plug filling. The influence of the testing speed on the repairs strength is also addressed (considering 0.5, 5 and 25 mm/min). Accounting for the temperature effects, tests were carried out at room temperature, 50ºC and 80ºC. This will permit a comparative evaluation of the adhesive tested below and above the Glass Transition Temperature (Tg), established by the manufacturer at 67ºC. The global tendencies of the test results concerning the plug filling and overlap length analyses are interpreted from the fracture modes and typical stress distributions for bonded repairs. According to the results obtained from this work, design guidelines for repairing aluminium structures were recommended.
Resumo:
Between 2000/01 and 2006/07, the approval rate of a Thermodynamics course in a Mechanical Engineer graduation was 25%. However, a careful analysis of the results showed that 41% of the students chosen not to attend or dropped out, missing the final examination. Thus, a continuous assessment methodology was developed, whose purpose was to reduce drop out, motivating students to attend this course, believing that what was observed was due, not to the incapacity to pass, but to the anticipation of the inevitability of failure by the students. If, on one hand, motivation is defined as a broad construct pertaining to the conditions and processes that account for the arousal, direction, magnitude, and maintenance of effort, on the other hand, assessment is one of the most powerful tools to change the will that students have to learn, motivating them to learn in a quicker and permanent way. Some of the practices that were implemented, included: promoting learning goal orientation rather than performance goal orientation; cultivating intrinsic interest in the subject and put less emphasis on grades but make grading criteria explicit; emphasizing teaching approaches that encourage collaboration among students and cater for a range of teaching styles; explaining the reasons for, and the implications of, tests; providing feedback to students about their performance in a form that is non-egoinvolving and non-judgemental and helping students to interpret it; broadening the range of information used in assessing the attainment of individual students. The continuous assessment methodology developed was applied in 2007/08 and 2008/09, having found an increase in the approval from 25% to 55% (30%), accompanied by a decrease of the drop out from 41% to 23,5% (17,5%). Flunking with a numerical grade lowered from 34,4% to 22,0% (12,4%). The perception by the students of the continuous assessment relevance was evaluated with a questionnaire. 70% of the students that failed the course respond that, nevertheless, didn’t repent having done the continuous assessment.
Resumo:
The structural integrity of multi-component structures is usually determined by the strength and durability of their unions. Adhesive bonding is often chosen over welding, riveting and bolting, due to the reduction of stress concentrations, reduced weight penalty and easy manufacturing, amongst other issues. In the past decades, the Finite Element Method (FEM) has been used for the simulation and strength prediction of bonded structures, by strength of materials or fracture mechanics-based criteria. Cohesive-zone models (CZMs) have already proved to be an effective tool in modelling damage growth, surpassing a few limitations of the aforementioned techniques. Despite this fact, they still suffer from the restriction of damage growth only at predefined growth paths. The eXtended Finite Element Method (XFEM) is a recent improvement of the FEM, developed to allow the growth of discontinuities within bulk solids along an arbitrary path, by enriching degrees of freedom with special displacement functions, thus overcoming the main restriction of CZMs. These two techniques were tested to simulate adhesively bonded single- and double-lap joints. The comparative evaluation of the two methods showed their capabilities and/or limitations for this specific purpose.
Resumo:
A comparative study concerning the robustness of a novel, Fixed Point Transformations/Singular Value Decomposition (FPT/SVD)-based adaptive controller and the Slotine-Li (S&L) approach is given by numerical simulations using a three degree of freedom paradigm of typical Classical Mechanical systems, the cart + double pendulum. The effects of the imprecision of the available dynamical model, presence of dynamic friction at the axles of the drives, and the existence of external disturbance forces unknown and not modeled by the controller are considered. While the Slotine-Li approach tries to identify the parameters of the formally precise, available analytical model of the controlled system with the implicit assumption that the generalized forces are precisely known, the novel one makes do with a very rough, affine form and a formally more precise approximate model of that system, and uses temporal observations of its desired vs. realized responses. Furthermore, it does not assume the lack of unknown perturbations caused either by internal friction and/or external disturbances. Its another advantage is that it needs the execution of the SVD as a relatively time-consuming operation on a grid of a rough system-model only one time, before the commencement of the control cycle within which it works only with simple computations. The simulation examples exemplify the superiority of the FPT/SVD-based control that otherwise has the deficiency that it can get out of the region of its convergence. Therefore its design and use needs preliminary simulation investigations. However, the simulations also exemplify that its convergence can be guaranteed for various practical purposes.
Resumo:
Introdução: Por mais de uma década assumiu-se que o transverso abdominal/oblíquo interno (TrA/OI) se comportava como um ventre muscular único, pré-ativando-se bilateralmente de forma simultânea para aumentar a stiffness da coluna lombar, conferindo-lhe estabilidade segmentar durante o movimento de um dos membros superiores. À luz dos estudos atuais sabe-se que tal mecanismo não ocorre, uma vez que o TrA/OI apresenta uma ativação por mecanismo de feedforward predominantemente contralateral ao membro superior movido. Apesar de morfologicamente o TrA/OI do lado não-dominante ser mais hipertrofiado do que o do lado dominante, nada se sabe acerca da influência da dominância nos timings ativação do TrA/OI. Objectivos: Confirmar se o TrA/OI tem um timing de ativação assimétrico durante o movimento rápido de flexão do membro superior (MRMS). Pretende-se ainda avaliar se o timing de ativação do TrA/OI é influenciado pela dominância de lateralidade manual. Métodos: Efectuou-se um estudo observacional descritivo, transversal e duplamente cego com 32 atletas de futebol voluntários com membro superior direito dominante, colocando-os apenas num grupo. Procedeu-se à recolha do sinal eletromiográfico de forma a avaliar os timings de ativação do TrA/OI bilateralmente aquando dos movimentos rápidos de flexão de ambos os membros superiores, à vez. Todos os dados foram tratados estatisticamente com o programa SPSS, versão 20.0 para Mac OS, com um grau de significância de 0,05. Resultados: Verificaram-se diferenças nos timings de ativação dos TrA/OI direito e esquerdo durante os MRMS direito e esquerdo (Teste ANOVA medidas repetidas: F=291,087; p<0,001). O timing de ativação do TrA/OI direito – 29,15(13,15)ms – foi superior ao esquerdo – 4,71(17,32)ms – durante MRMS direito (Teste Post Hoc Bonferroni: p<0,001). O timing de ativação do TrA/OI esquerdo – 31,98(12,50)ms – foi superior ao direito – 12,20(17,40)ms – durante MRMS esquerdo (p<0,001). O timing de ativação do TrA/IO direito aquando do MRMS direito foi superior ao observado durante MRMS esquerdo (p<0,001). O contrário sucedeu em relação ao timing ativação do TrA/IO esquerdo (p<0,001). O timing de ativação do TrA/IO esquerdo no MRMS direito foi inferior ao do TrA/IO direito aquando do movimento com o membro esquerdo (p<0,001). O TrA/IO direito possuiu um timing de ativação no MRMS direito inferior ao do TrA/IO esquerdo aquando do movimento com o membro esquerdo (p<0,001). Conclusão: Através deste estudo pôde-se concluir que o TrA/OI contralateral ao MRMS apresenta um timing de ativação inferior ao ipsilateral e ainda que durante o MRMS dominante o TrA/OI esquerdo e direito apresentam um timing de ativação inferior ao ocorrido durante o MRMS não-dominante.
Resumo:
IET Control Theory & Applications, Vol. 1, Nº 1
Resumo:
Dissertation submitted in partial fulfilment of the requirements for the Degree of Master of Science in Geospatial Technologies
Resumo:
Relatório de Estágio apresentado à Escola Superior de Educação de Lisboa para obtenção de grau de mestre em Ensino do 1º e 2º Ciclo do Ensino Básico
Resumo:
A double-blind clinical trial involving 120 patients with chronic schistosomiasis was carried out to compare the tolerability and efficacy of praziquantel and oxamniquine. The patients were randomly allocated into two groups. One was treated with praziquantel, 55 mg/kg of body weight CBWT), and the other one with oxamniquine, 15mg/kg bwt, administered in a single oral dose. The diagnosis and the parasitological follow-up was based on stool examinations by quantitative Kato-Katz method and on rectal biopsies. Side-effects mainly dizziness, sleepness, abdominal distress, headache, nausea and diarrhea were observed in 87% of the cases. Their incidence, intensity and duration were similar for both drugs but abdominal pain was significantly more frequent after praziquantel intake and severe dizziness was more commonly reported after oxamniquine. A significant increase of alanine-aminotransferase and y-glutamyltransferase was found with the latter drug and of total bilirubin with the former one. A total of 48 patients treated with praziquantel and 46 with oxamniquine completed with negative findings the required three post-treatment parasitological controls three slides of each stool sample on the first, third and sixth month. The achieved cure rates were 79.2% and 84.8%, respectively, a difference without statistical significance. The non-cured cases showed a mean reduction in the number of eggs per gram of feces of 93.5% after praziquantel and of 84.1% after oxamniquine. This diference also was not significant. Five patients retreated with praziquantel were cured but only one out of three treated a second time with oxamniquine. These findings show that both drugs despite their different chemical structures, pharmacological properties and mechanisms-of-action induce similar side-effects as well as a comparable therapeutical efficacy, in agreement with the results reported from analogous investigations.
Resumo:
Tese de Doutoramento
Resumo:
In presence of extracts of six flowering plants the Biomphalaria tenagophila was more attracted to four them in the following sequence: Nasturtium pumilum > Polygonum acre > Commelina sp. = Echinochloa crusgalli. The periphyton of these flowering plants attracted in the same way the B. tenagophila but without no preference for either of them. Reporting the results that behavior may be evaluated as a co-evolution between snail and plants.
Resumo:
A double pi'npin heterostructure based on amorphous SiC has a non linear spectral gain which is a function of the signal wavelength that impinges on its front or back surface. An impulse of a configurable length and amplitude is applied to a 390 nm LED which illuminates one of the sensor surfaces, followed by a time period without any illumination after which an input signal with a different wavelength is impinged upon the front surface. Results show that the intensity and duration of the impulse illumination of the surfaces influences the sensor's response with different output for the same input signal. This paper studies this effect and proposes an application as a short term light memory. (C) 2015 Elsevier B.V. All rights reserved.