595 resultados para drain
Resumo:
Power back-off performances of a new variant power-combining Class-E amplifier under different amplitude-modulation schemes such as continuous wave (CW), envelope elimination and restoration (EER), envelope tracking (ET) and outphasing are for the first time investigated in this study. Finite DC-feed inductances rather than massive RF chokes as used in the classic single-ended Class-E power amplifier (PA) resulted from the approximate yet effective frequency-domain circuit analysis provide the wherewithal to increase modulation bandwidth up to 80% higher than the classic single-ended Class-E PA. This increased modulation bandwidth is required for the linearity improvement in the EER/ET transmitters. The modified output load network of the power-combining Class-E amplifier adopting three-harmonic terminations technique relaxes the design specifications for the additional filtering block typically required at the output stage of the transmitter chain. Qualitative agreements between simulation and measurement results for all four schemes were achieved where the ET technique was proven superior to the other schemes. When the PA is used within the ET scheme, an increase of average drain efficiency of as high as 40% with respect to the CW excitation was obtained for a multi-carrier input signal with 12 dB peak-to-average power ratio. © 2011 The Institution of Engineering and Technology.
Resumo:
RATIONALE: Characterization of bacterial populations in infectious respiratory diseases will provide improved understanding of the relationship between the lung microbiota, disease pathogenesis and treatment outcomes.
OBJECTIVES: To comprehensively define lung microbiota composition during stable disease and exacerbation in bronchiectasis patients.
METHODS: Sputum was collected from patients when clinically stable and before and after completion of antibiotic treatment of exacerbations. Bacterial abundance and community composition were analyzed using anaerobic culture and 16S rDNA pyrosequencing.
MEASUREMENTS AND MAIN RESULTS: In clinically stable patients, aerobic and anaerobic bacteria were detected in 40/40 (100%) and 33/40 (83%) sputum samples, respectively. The dominant organisms cultured were P. aeruginosa (n=10 patients), H. influenzae (n=12), Prevotella (n=18) and Veillonella (n=13). Pyrosequencing generated over 150,000 sequences, representing 113 distinct microbial taxa; the majority of observed community richness resulted from taxa present in low abundance with similar patterns of phyla distribution in clinically stable patients and patients at the onset of exacerbation. Following treatment of exacerbation, there was no change in total (p=0.925), aerobic (p=0.917) or anaerobic (p=0.683) load and only a limited shift in community composition. Agreement for detection of bacteria by culture and pyrosequencing was good for aerobic bacteria such as P. aeruginosa (kappa=0.84) but poorer for other genera including anaerobes. Lack of agreement was largely due to bacteria been detected by pyrosequencing but not by culture.
CONCLUSIONS: A complex microbiota is present in the lungs of bronchiectasis patients which remains stable through treatment of exacerbations suggesting that changes in microbiota composition do not account for exacerbations.
Resumo:
Experimental assessments of the modified power-combining Class-E amplifier are described. The technique used to combine the output of individual power amplifiers (PAs) into an unbalanced load without the need for bulky transformers permits the use of small RF chokes useful for the deployment in the EER transmitter. The modified output load network of the PA results in excellent 50 dBc and 46 dBc second and third-harmonic suppressions, dispensing the need for additional lossy filtering block. Operating from a 3.2 V dc supply voltage, the PA exhibits 64% drain efficiency at 24 dBm output power. Over a wide bandwidth of 350 MHz, drain efficiency of better than 60% at output power higher than 22 dBm were achieved. © 2010 IEICE Institute of Electronics Informati.
Resumo:
Power back-off performances of the modified power-combining Class-E amplifier under different amplitudemodulation schemes such as envelope elimination and restoration (EER) and envelope tracking (ET) are experimentally assessed in this paper. The modified output load network adopting three-harmonic terminations technique eliminates the need for additional lossy filtering section in the transmitter chain. Small dc-feed inductances rather than massive RF chokes as in the classic Class-E amplifier are used so as to increase the modulation bandwidth and therefore improve the linearity of the EER transmitter. High efficiency over a wide dynamic range using amplitude modulation through drain-voltage control (EER) was achieved and this agrees well with the Class-E theoretical prediction. When the PA was used within the ET scheme, an increase of average drain efficiency of as high as 40% with respect to the CW excitation was obtained for a multi-carrier input signal with 12dB peak-to-average power ratio. © 2011 Institut fur Mikrowellen.
Resumo:
There is a dearth of empirical studies on talent management (TM) in the emerging markets, and in particular a lack of research on TM in the countries of the Central and Eastern European (CEE) region. Our empirical study in 58 organisations in Poland, a major economy in the CEE region, is one of the first studies to examine TM in this context. Our study highlights the particular nature of the TM challenges facing organisations in Poland and shows that there is little evidence to suggest that Polish practice is converging with Western models. Our paper suggests that TM is likely to challenge many traditional management practices and attitudes which continue to dominate Polish culture in the period of transition to a market economy.
Resumo:
This paper presents the design and implementation of a low-voltage-stress Class-EF power amplifier (PA) with extended maximum operating frequency, named as ‘third-harmonic-peaking Class-EF PA’. A novel transmission-line load network is proposed to meet the Class-EF impedance requirements at the fundamental, all even harmonics, and third harmonic components. It also provides an impedance matching to a 50 Ω load. A more effective λ/8 open- and shorted-stub network is deployed at the drain of the transistor replacing the traditional λ/4 transmission line. Implemented using GaN HEMTs, the PA delivered 39.2 dBm output power with 80.5% drain efficiency and 71% PAE at 2.22 GHz.
Resumo:
To develop and implement a risk assessment process for all unlicenced medicinal products in use within the Belfast City Hospital.
Over half 65% of the unlicenced medicinal products currently in use were rated low or minor risk and therefore required no recording upon supply.
This has greatly improved the way unlicensed medicines are prescribed, procured, supplied and administered within the Belfast City Hospital.
High-Efficiency Harmonic-Peaking Class-EF Power Amplifiers with Enhanced Maximum Operating Frequency
Resumo:
The recently introduced Class-EF power amplifier (PA) has a peak switch voltage lower than that of the Class-E PA. However, the value of the transistor output capacitance at high frequencies is typically larger than the required Class-EF optimum shunt capacitance. Consequently, soft-switching operation that minimizes power dissipation during off-to-on transition cannot be achieved at high frequencies. Two new Class-EF PA variants with transmission-line load networks, namely, third-harmonic-peaking (THP) and fifth-harmonic-peaking (FHP) Class-EF PAs are proposed in this paper. These permit operation at higher frequencies at no expense to other PA figures of merit. Analytical expressions are derived in order to obtain circuit component values, which satisfy the required Class-EF impedances at fundamental frequency, all even harmonics, and the first few odd harmonics as well as simultaneously providing impedance matching to a 50- Ω load. Furthermore, a novel open-circuit and shorted stub arrangement, which has substantial practical benefits, is proposed to replace the normal quarter-wave line connected at the transistor's drain. Using GaN HEMTs, two PA prototypes were built. Measured peak drain efficiency of 91% and output power of 39.5 dBm were obtained at 2.22 GHz for the THP Class-EF PA. The FHP Class-EF PA delivered output power of 41.9 dBm with 85% drain efficiency at 1.52 GHz.
Resumo:
Introduction and Aims: Persistent bacterial infection is a major cause of morbidity and mortality in patients with both Cystic Fibrosis (CF) and non-CF Bronchiectasis (non-CFBX). Numerous studies have shown that CF and non-CFBX airways are colonised by a complex microbiota. However, many bacteria are difficult, if not impossible, to culture by conventional laboratory techniques. Therefore, molecular detection techniques offer a more comprehensive view of bacterial diversity within clinical specimens. The objective of this study was to characterise and compare bacterial diversity and relative abundance in patients with CF and non-CFBX during exacerbation and when clinically stable.
Methods: Sputum samples were collected from CF (n=50 samples) and non-CFBX (n=52 samples) patients at the start and end of treatment for an infective exacerbation and when clinically stable. Pyrosequencing was used to assess the microbial diversity and relative genera (or the closest possibly taxonomic order) abundance within the samples. Each sequence read was defined based on 3% difference.
Results: High-throughput pyrosequencing allowed a sensitive and detailed examination of microbial community composition. Rich microbial communities were apparent within both CF (171 species-level phylotypes per genus) and non-CFBX airways (144 species-level phylotypes per genus). Relative species distribution within those two environments was considerably different; however, relatively few genera formed a core of microorganisms, representing approximately 90% of all sequences, which dominated both environments. Relative abundance based on observed operational taxonomic units demonstrated that the most abundant bacteria in CF were Pseudomonas (28%), Burkholderia (22%), Streptococcus (13%), family Pseudomonadaceae (8%) and Prevotella (6%). In contrast, the most commonly detected operational taxonomic units in non-CFBX were Haemophilus (22%), Streptococcus (14%), other (unassigned taxa) (11%), Pseudomonas (10%), Veillonella (7%) and Prevotella (6%).
Conclusions: These results suggest that distinctive microbial communities are associated with infection and/or colonisation in patients with both CF and non-CFBX. Although relatively high species richness was observed within the two environments, each was dominated by different core taxa. This suggests that differences in the lung environment of these two diseases may affect adaptability of the relevant bacterial taxa.
Resumo:
‘A free Ireland would drain the bogs, would harness the rivers, would plant the wastes, would nationalise the railways and the waterways, would improve agriculture, would protect fisheries, would foster industries, would promote commerce, and beautify the cities …’ (Padraig Pearse, ‘From a Hermitage’, 1913)
Somewhat unusually in his often romantic writings Padraig Pearse – poet, pedagogue and revolutionary – chose to describe the future of an independent Ireland in terms of infrastructure and technological processes. Terence Brown’s locating of this excerpt at the beginning his seminal work Ireland: A Social and Cultural History 1922-2002 highlights the simultaneous and interlinking construction of both a new physical and cultural landscape for an independent modern nation. Lacking any significant industrial complex, the construction of new infrastructures in Ireland was seen throughout the 20th century as a key element in the building of the new State, just as the adoption of an international style modernism in architecture was perceived as a way to escape the colonial past. For Paul N. Edwards modernity and infrastructure are intimately connected.
‘infrastructures simultaneously shape and are shaped – in other words, co-construct – the condition of modernity. By linking macro, meso, and micro scales of time, space and social organisation, they form the stable foundation of modern social worlds’ (2003: 186).
Simultaneously omnipresent and invisible – infra means beneath – Edwards also points out that infrastructure tends only to become apparent when it is either new or broken. Interpreting the meso scale as being that of the building, this session calls for papers that critically and analytically investigate aspects of the architectures of infrastructure in 20th-century Ireland. Like the territory they explore these papers may range across scales to oscillate between a concern for the artefact and its physical landscape, and the larger, often hidden systems and networks that co-define this architecture.